| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.1 LAccepted-AOC 712 GORAKHPUR JABALPUR 482001 MP | JABALPUR | MADHYA PRADESH | 482001 | L1 | Accepted-AOC L1 bidder lowest | |
| 2 | L2₹34.6 L+₹1.8 L (5.35%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹36.0 L+₹3.1 L (9.58%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹37.0 L+₹4.2 L (12.6%)Rejected-Finance 1814 NARSING NAGAR RANJHI JABALPUR MP 482005 | JABALPUR | JABALPUR | MADHYA PRADESH | 482005 | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹37.5 L+₹4.7 L (14.2%)Rejected-Finance HDLX 31 JASUJA CITY JABALPUR MP 482003 | JABALPUR | MADHYA PRADESH | 482003 | L5 | Rejected-Finance Other than L1 |
| Sl No | Description | Qty | Unit | RAVI TEJ BUILDERS L1 | TRISHLA CONSTRUCTIONS L4 | ANAMIKA CONSTRUCTION L5 | titiksha india L2 | kiran electrical and hardware centre L3 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down carefully any type of old unserviceable point wiring copper or aluminium conductor (light, fan, socket, bell or power) point complete with fittings such as switches ceiling roses, lamp holders, sockets, fan regulators, call bell, light fittings with PVC conduit surface / concealed or wooden battens including sunken cast iron / pressed steel terminal boxes etc and making good the disturbed surfaces of walls, roof, floors etc to match with the existing surfaces complete all as specified and as directed. | 1,745 | Per Point | 10 ₹17,450 | 5 ₹8,725 | 10 ₹17,450 | 3 ₹5,235 Lowest | 5 ₹8,725 |
| 2.00 | Taking down carefully main switches / distribution boards complete of any size and refixing after repair and MCBs SP /SPN or Cut out of any size all as required and directed at site | 87 | Each | 10 ₹870 | 5 ₹435 | 10 ₹870 | 4 ₹348 Lowest | 5 ₹435 |
| 3.00 | Repair the sub main wiring with detecting the fault and repair the point after replace the u/s wire of 2.5 sqmm copper conductor cable drawing into existing PVC conduit and jointing properly including taping with ISI mark insulation tape all as required and directed at site. | 350 | RM | 25 ₹8,750 Lowest | 43 ₹15,050 | 50 ₹17,500 | 40 ₹14,000 | 40 ₹14,000 |
| 4.00 | Repair the sub main wiring with detecting the fault and repair the point after replace the u/s wire of 4 sqmm copper conductor cable drawing into exxisting PVC conduit and jointing properly including taping with ISI mark insulation tape all as required and directed at site | 300 | RM | 30 ₹9,000 Lowest | 53 ₹15,900 | 60 ₹18,000 | 50 ₹15,000 | 45 ₹13,500 |
| 5.00 | Repair the sub main wiring with detecting the fault and repair the point after replace the u/s wire of 6.0 sqmm copper conductor cable drawing into existing PVC conduit and jointing properly including taping with ISI mark insulation tape all as required and directed at site | 250 | RM | 30 ₹7,500 Lowest | 63 ₹15,750 | 70 ₹17,500 | 60 ₹15,000 | 50 ₹12,500 |
| 6.00 | Repair the sub main wiring with detecting the fault and repair the point after replace the u/s wire of 10.0 sqmm copper conductor cable drawing into existing PVC conduit and jointing properly including taping with ISI mark insulation tape all as required and directed at site | 90 | RM | 35 ₹3,150 Lowest | 73 ₹6,570 | 90 ₹8,100 | 90 ₹8,100 | 60 ₹5,400 |
| 7.00 | Repair to point wiring with taking out the fault removing the u/s / brunt wire and repair with repalacemnt of wire jointing properly with connector and making the point serviceable (replacemnt of wire not more then 1.5 mtrs, junction box cover / connection of point is included in type cost of repair) and making the point serviceable all as required and directed at site | 500 | Each | 120 ₹60,000 | 48 ₹24,000 Lowest | 90 ₹45,000 | 100 ₹50,000 | 120 ₹60,000 |
| 8.00 | M& L for comprehensive maintenance and repair to point wirring with taking out fault in the wiring and repair to the point wring and making the point wiring serviceable including following works
(a) Checking proper working of wiring light or fan point
(b) Checking of socket point/switch /holder point including replacement of unseviceable part
(c) Replacement of unserviceable batten holder/ tube light/lamps/ ballast/bipin holder /fittings
(d) Cleaning of tube light fitting
Note : 1.Contractor has to depute two electricians including one helper with each electrician daily who will report to JE E/M in mes YARD under AGE E/M E/S. 2 Unserviceable parts to be measured & paid seperately under relevant item of Sch A. All Tools & Plants and ladder provided to electrician at site by The contractor. | 100 | Each job | 100 ₹10,000 | 195 ₹19,500 | 50 ₹5,000 Lowest | 50 ₹5,000 Lowest | 60 ₹6,000 |
| 9.00 | Taking down the old unsv sub main wiring of any size all as required and directed at site | 740 | RM | 10 ₹7,400 | 5 ₹3,700 | 5 ₹3,700 | 3 ₹2,220 Lowest | 5 ₹3,700 |
| 10.00 | M&L of Sub main wiring with two single core PVC Insulated cable two run of size 4 Sqmm multi-strand copper conductor FRLSH cable 1100 volts grade drawing in and including PVC conduit, medium grade not less than 20 mm dia with all conduit accessories and one run of 4.0 Sqmm multi-strand copper conductor FRLSH cable as continuous earth wire including making good disturbed surface to match existing complete all as specified and as directed. Note : - Two runs of 4 Sqmm & one run of 4.0 Sqmm cable shall be measured as one unit run. | 400 | RM | 200 ₹80,000 Lowest | 240 ₹96,000 | 200 ₹80,000 Lowest | 230 ₹92,000 | 330 ₹1,32,000 |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
7 Oct 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (West) Jabalpur
Garrison Engineer (West) Jabalpur Supply Marg Post Box No. 54 Jabalpur Cantt-482001 (MP)
DAY TO DAY MAINTENANCE OF E/M SERVICES AND ALLIED WORK OF MD ACCN AGE E/S OF GE (WEST) JABALPUR
2025_MES_729920_1
8944/E8
Open Tender
Civil Works
Item Rate
180 days
GE (West) Jabalpur
As per tender documents
6 documents required · 6 mandatory
₹500
GE (West) Jabalpur
₹94,000
10 Feb 2026
9 Sept 2025
10 Oct 2025
10 Sept 2025
7 Oct 2025
23 Sept 2025
10 Sept 2025 - 18 Sept 2025
Amount
Taking down carefully any type of old unserviceable point wiring copper or aluminium conductor (light, fan, socket, bell or power) point complete with fittings such as switches ceiling roses, lamp holders, sockets, fan regulators, call bell, light fittings with PVC conduit surface / concealed or wooden battens including sunken cast iron / pressed steel terminal boxes etc and making good the disturbed surfaces of walls, roof, floors etc to match with the existing surfaces complete all as specified and as directed.
Taking down carefully main switches / distribution boards complete of any size and refixing after repair and MCBs SP /SPN or Cut out of any size all as required and directed at site
Repair the sub main wiring with detecting the fault and repair the point after replace the u/s wire of 2.5 sqmm copper conductor cable drawing into existing PVC conduit and jointing properly including taping with ISI mark insulation tape all as required and directed at site.
Repair the sub main wiring with detecting the fault and repair the point after replace the u/s wire of 4 sqmm copper conductor cable drawing into exxisting PVC conduit and jointing properly including taping with ISI mark insulation tape all as required and directed at site
Repair the sub main wiring with detecting the fault and repair the point after replace the u/s wire of 6.0 sqmm copper conductor cable drawing into existing PVC conduit and jointing properly including taping with ISI mark insulation tape all as required and directed at site
Repair the sub main wiring with detecting the fault and repair the point after replace the u/s wire of 10.0 sqmm copper conductor cable drawing into existing PVC conduit and jointing properly including taping with ISI mark insulation tape all as required and directed at site
Repair to point wiring with taking out the fault removing the u/s / brunt wire and repair with repalacemnt of wire jointing properly with connector and making the point serviceable (replacemnt of wire not more then 1.5 mtrs, junction box cover / connection of point is included in type cost of repair) and making the point serviceable all as required and directed at site
M& L for comprehensive maintenance and repair to point wirring with taking out fault in the wiring and repair to the point wring and making the point wiring serviceable including following works (a) Checking proper working of wiring light or fan point (b) Checking of socket point/switch /holder point including replacement of unseviceable part (c) Replacement of unserviceable batten holder/ tube light/lamps/ ballast/bipin holder /fittings (d) Cleaning of tube light fitting Note : 1.Contractor has to depute two electricians including one helper with each electrician daily who will report to JE E/M in mes YARD under AGE E/M E/S. 2 Unserviceable parts to be measured & paid seperately under relevant item of Sch A. All Tools & Plants and ladder provided to electrician at site by The contractor.
Taking down the old unsv sub main wiring of any size all as required and directed at site
M&L of Sub main wiring with two single core PVC Insulated cable two run of size 4 Sqmm multi-strand copper conductor FRLSH cable 1100 volts grade drawing in and including PVC conduit, medium grade not less than 20 mm dia with all conduit accessories and one run of 4.0 Sqmm multi-strand copper conductor FRLSH cable as continuous earth wire including making good disturbed surface to match existing complete all as specified and as directed. Note : - Two runs of 4 Sqmm & one run of 4.0 Sqmm cable shall be measured as one unit run.
M&L of Sub main wiring with two single core PVC Insulated cable two run of size 6.0 Sqmm multi-strand copper conductor FRLSH cable 1100 volts grade drawing in and including PVC conduit, medium grade not less than 25 mm dia with all conduit accessories and one run of 6.0 Sqmm multi-strand copper conductor FRLSH cable as continuous earth wire complete all as specified and as directed. Note : - Two runs of 6 Sqmm & one run of 6 Sqmm cable shall be measured as one unit run.
M&L of Sub main wiring with two single core PVC Insulated cable two run of size 10.0 Sqmm multi-strand copper conductor FRLSH cable 1100 volts grade drawing in and including PVC conduit, medium grade not less than 25 mm dia with all conduit accessories and one run of 10.0 Sqmm multi-strand copper conductor FRLSH cable as continuous earth wire complete all as specified and as directed. Note : - Two runs of 10 Sqmm & one run of 10 Sqmm cable shall be measured as one unit run.
Supply & fixing in repair 25 mm dia non mettalic Rigid PVC conduit, ISI Marked conforming to IS : 9537 medium grade Including all fittings like bends, elbow reducer, junction boxes, tee bell mouth fixing accessories such as coupler lock, nuts, saddles pipe hooks etc complete including cutting & chasing required on brick wall not exceeding 10 CM girth for concealed conduit wiring and making good to disturbed surface with cement mortar 1:3 and treated with distemper or colour wash to match with existing surfaces complete all as specified and as directed.
Supply & fixing in repair 20 mm non mettalic Rigid PVC casing caping conduit, ISI Marked Including all fittings like bends, elbow reducer, junction boxes, tee bell mouth fixing accessories such as coupler lock, nuts, saddles pipe hooks etc complete including fixing on wall and making good the disturbed surface with cement mortar 1:3 and treated with distemper or colour wash to match with existing surfaces complete all as specified and as directed.
Material & Labour for point wiring with three layer PVC Insulated 1.5 Sqmm multi-strand copper conductor FRLSH cable 1100 Volts grade drawn into and concealed PVC conduits medium grade not less than 20mm( ISI marked) including all fitting and fixing accessories including 1.25 mm thick sunken pressed steel terminal boxes/Modular metal flush box duly painted with two coats of anti-corrosive paint outside and two coats of aluminium paint inside with and including 3mm thick hylam brand laminated white bakelite sheet cover for mounting switches, sockets, fan regulators fixed with CP screws with cup wahsers and PVC insulated 1.5 Sqmm multi-strand copper conductor cable as earth wire and making good the disturbed surfaces with cement sand mortar 1:3 to match with the existing surfaces complete all as specified & directed by Engineer-in-charge for One light Point controlled by one switch.
All as described in Srl Item No 15 above, but for one Fan Point controlled by one switch.
All as described in Srl Item No 15 above, but for one Bell Point controlled by one switch.
Description same all as per item No. 15 here in above but with 1100 Volts grade copper stranded conductor FRLSH cable of size 2.5 Sqmm main & with 2.5 Sqmm earth multi-strand copper conductor cable as earth wire for 3 pin switch socket outlet 5 Amp on same board complete all as specified and as directed.
All as described in Srl Item No 15 above, but with 1100 Volts grade copper stranded conductor FRLSH cable of size 2.5 Sqmm main & with 2.5 Sqmm earth multi-strand copper conductor cable as earth wire for 3 pin switch socket outlet 5 Amp on independent board complete all as specified and as directed.
All as described in Srl Item No 15 above, but but for one light point controlled by two way switch.
All as described in Srl Item No 15 above, but with 1100 Volts grade copper stranded conductor FRLSH cable of size 2.5 Sqmm main & with 2.5 Sqmm earth multi-strand copper conductor cable as earth wire for 3 pin switch socket outlet 15 Amp on Independent board complete all as specified and as directed.
Material & Labour for point wiring with three layer PVC Insulated 1.5 Sqmm multi-strand copper conductor FRLSH cable 1100 Volts grade drawn into the existing conduits including all fitting and fixing accessories including 1.25 mm thick sunken pressed steel terminal boxes duly painted with two coats of anti-corrosive paint outside and two coats of aluminium paint inside with and including 3mm thick hylam brand laminated white bakelite sheet cover for mounting switches, sockets, fan regulators fixed with CP screws with cup wahsers and PVC insulated 1.5 Sqmm multi-strand copper conductor cable as earth wire and making good the disturbed surfaces with cement sand mortar 1:3 to match with the existing surfaces complete all as specified & directed by Engineer-in-charge for one light Point controlled by one switch.
All as described in Srl Item No 22 above, but for one Fan Point controlled by one switch.
All as described in Srl Item No 22 above, but for one Bell Point controlled by one switch.
Description same all as per item No. 22 here in above but with 1100 Volts grade copper stranded conductor FRLSH cable of size 2.5 Sqmm main & with 2.5 Sqmm earth multi-strand copper conductor cable as earth wire for 3 pin switch socket outlet 5 Amp on same board complete all as specified and as directed.
All as described in Srl Item No 22 above, but with 1100 Volts grade copper stranded conductor FRLSH cable of size 2.5 Sqmm main & with 2.5 Sqmm earth multi-strand copper conductor cable as earth wire for 3 pin switch socket outlet 5 Amp on independent board complete all as specified and as directed.
All as described in Srl Item No 22 above, but but for one light point controlled by two way switch.
All as described in Srl Item No 22 above, but with 1100 Volts grade copper stranded conductor FRLSH cable of size 2.5 Sqmm main & with 2.5 Sqmm earth multi-strand copper conductor cable as earth wire for 3 pin switch socket outlet 15 Amp on Independent board complete all as specified and as directed.
S&F call bell ding dong sound type suitable for AC 230 volt single pole complete all as specified and as directed.
S&F switch bell push flush type suitable for 5 Amp 230 Volt of polycarbonate body complete all as specified and as directed.
S&F switch piano flush type suitable for 5 Amp 230 Volt of polycarbonate body complete all as specified and as directed.
S&F socket outlet 2 in 1, 5 Pin 5 Amp flush type of polycarbonate body complete all as specified and as directed.
S&F Switch socket combination 5 in 1, 5 pin 5/6 Amps flush type universal of polycabonate body complete all as specified and as directed.
S&F Switch/socket combination 16 Amps flush type universal of polycabonate body complete all as specified and as directed.
S&F lamp holder / batten or angle holder Insulated body incl 9w LED bulb with back plate suitable for batten fittings complete all as specified and as directed
S&F Ceiling rose surface type 60x30 mm three terminals of polycarbonate body complete all as specified and as directed.
S&F Ceiling Fan regulator electronic type 280 Watt capacity of polycarbonate body ISI marked complete all as specified and as directed.
S&F in replacement of frame plate for modular switch 1 module including screws and washers etc model/make as per existing in site complete all as specified and as directed.
S&F in replacement of frame plate for modular switch 2 module including screws and washers etc model/make as per existing in site complete all as specified and as directed.
S&F in replacement of frame plate for modular switch 3 module including screws and washers etc model/make as per existing in site complete all as specified and as directed.
S&F in replacement of frame plate for modular switch 4 module including screws and washers etc model/make as per existing in site complete all as specified and as directed.
S&F in replacement of frame plate for modular switch 6 module including screws and washers etc model/make as per existing in site complete all as specified and as directed.
S&F in replacement of frame plate for modular switch 8 module including screws and washers etc model/make as per existing in site complete all as specified and as directed.
S&F in replacement MS Housing box 1/2 module suitable for modular switch as per existing switch box and making good to the disturb surface complete all as specified and as directed.
S&F in replacement MS Housing box 3 module suitable for modular switch as per existing switch box and making good to the disturb surface complete all as specified and as directed.
S&F in replacement MS Housing box 4/5 module suitable for modular switch as per existing switch box and making good to the disturb surface complete all as specified and as directed.
S&F in replacement MS Housing box 6/8 module suitable for modular switch as per existing switch box and making good to the disturb surface complete all as specified and as directed.
S&F in replacement of modular switch 6-10 Amps one module 230 volts AC as per existing model/make complete all as specified and as directed
S&F in replacement of modular switch 16 Amps one module 230 volts AC as per existing model/make complete all as specified and as directed
S&F in replacement of modular socket, 6A -2/3 pin combined 2 module, 230 volts AC as per existing model/make complete all as specified and as directed.
S&F in replacement of modular socket, 6/16A -2/3 pin combined 2 module, 230 volts AC as per existing model/make complete all as specified and as directed .
S&F in replacement modular fan regulator, 2 Module 4 step 180w heavy duty 230 volts as per existing model/make complete all as specified and as directed.
S&F in replacement of 3mm thick hylam sheet of any size including brass screws and washers etc as per required at site complete all as specified and as directed.
S&F in replacement modular bell push switch piano, flush type, 6 Amps complete all as specified and as directed.
Supply & Fixing Smart bright Batten Series, LED luminaire using LED 10 watt mirror with diffuser which ensures uniform distribution and comfort batten series features, latest LED which delivers consistent light output with wide voltage protection range, stable color start, Extruded Aluminium housing, Energy efficient, Flicker free start, In-built driver unit suitable for wall and ceiling mounting using brackets (supplied along with the Luminaire to be tested as per Standard Specification IEC 60598-2-1 / IS: 10322(Parts/Sec-l), to establish conformity of the product(s) to the requirements with the following specifications:- (a) Size :- 2 ft (b) IP rating = IP 20 (c) Power factor= min 0.9 (d) CRI= max 80% (e) Surge Protection = 2.5KV (f) LED Driver should be complete with att standard portections as design of manufacturer (g) Voltage operating range: 140-270V (h) THD = max 20% (j) Lumen Efficacy= min 900 Lumen (k) CCT=6500K
S&F Bulk head endura LED light fitting complete with and including 10 Watt LED and making necessary electric connection with copper conductor of suitable size and accessories & length complete all as specified and as directed with the following specifications:- (a) Size:-205mm x 70mm x 100mm (b) Main Current - 0.045 A (c) Power factor:- ≥0.95 (d) CRI: ≥80 (e) Surge Protection :- 4 KV (f) Voltage operating range: 120-270V (g) THD - ≤ 15% (h) Driver efficiency :- 90% (j) Lumen Efficacy:- 100 lm/w (k) Life (Hrs) :- 35,000 (l) CCT:- 4000/6500K (IP Rating) : IP65
Supply & Fixing Smart bright Batten Series, LED luminaire using LED 22 watt with diffuser which ensures uniform distribution and comfort batten series features, latest LED which delivers consistent light output with wide voltage protection range, stable color start, Extruded Aluminum housing, Energy efficient, Flicker free start, In-built driver unit suitable for wall and ceiling mounting using brackets (supplied along with the Luminaire to be tested as per Standard Specification IEC 60598-2-1 / IS: 10322(Parts/Sec-l), to establish conformity of the product(s) to the requirements with the following specifications:- (a) Size :- 4 ft (b) IP rating = IP 20 (c) Power factor= min 0.9 (d) CRI= max 80% (e) Surge Protection = 2.5KV (f) LED Driver should be complete with att standard portections as design of manufacturer. (g) Voltage operating range: 120-240V, 50 Hz (h) THD = max 20% (j) Lumen Efficacy= min100 Lumen/Watt (k) CCT=4000K
Supply & Fixing Smart bright Batten Series, LED luminaire using LED 22 watt with diffuser which ensures uniform distribution and comfort batten series features, latest LED which delivers consistent light output with wide voltage protection range, stable color start, Extruded Aluminium housing, Energy efficient, Flicker free start, In-built driver unit suitable for wall and ceiling mounting using brackets (supplied along with the Luminaire ti be tested as per Standard Specification IEC 60598-2-1 / IS: 10322(Parts/Sec-l), to establish conformity of the product(s) to the requirements with the following specifications:- (a) Size :- 4 ft (b) IP rating = IP 20 (c) Power factor= min 0.9 (d) CRI= max 80% (e) Surge Protection = 2.5KV (f) LED Driver should be complete with all standard portections as per design of Manufacturer. (g) Voltage operating range: 120-240V (h) THD = max 20% (j) Lumen Efficacy= min100 Lumen/Watt (k) CCT=6500K
S&F LED light fitting square 2'x2' , 30 watt, 3000 lumen, Cool white, 6500K, THD max 10 % ,Voltage operating range: 140-270V, Surge Protection :- 2.5 to 3.5KV, CRI min 80% warm white along with fixture Surface / Recessed /Pendent mounting LED luminaires with diffuser, channel Luminaires ers, connector block, etc . Complete with all accessories internally pre-wired and including round wooden block, connecting up with three core flexible copper conductor cable of suitable size and length complete all as specified and as directed .
S&F LED light fitting square 2'x2', 30 Watt, 3000 lumen, Warm, white 5700K, THD max 10 % ,Voltage operating range: 140-270V, Surge Protection :- 2.5 to 3.5KV, CRI min 80 % warm, white along with fixture Surface / Recessed /Pendent mounting LED luminaires with diffuser, channel Luminaires ers, connector block, etc . complete with all accessories, internally pre-wired and including round wooden block, connecting up with three core flexible copper conductor cable of suitable size and length complete all as specified and as directed .
Supply & fixing, in repair, LED light down lighter by recess or surface mounted 12 Watt, warm white/cool white, circular/Square, 1200 lumen with fixing arrangemnts on ceiling complete all as specified & directed with the following specifications:- (a) Size :- dia 180mm x26 mm thick for circular and 180mmx180mm x6mm for Square (Shape as per Site requirements either square or circular) (b) IP rating = IP 20 (c) Power factor= min 0.9 (d) CRI= max 80% (e) Surge Protection = 2.5KV (f) LED Driver should be complete with all standard portections as per design of Manufacturer. (g) Voltage operating range: 140-270V (h) THD = max 20% (j) Lumen Efficacy= min1200 Lumen (k) CCT=4000/6500 (CCT will be as per site requirement either 4000 or 6500)
Supply & fixing, in repair, LED light down lighter by recess or surface mounted 18 Watt, warm white/cool white, circular/Square, 1200 lumen with fixing arrangemnts on ceiling complete all as specified & directed with the following specification:- (a) Size :- dia 220mm x26 mm thick for circular and 220mmx220mm x6mm for Square (Shape as per Site requirements either square or circular) (b) IP rating = IP 20 (c) Power factor= min 0.9 (d) CRI= max 80% (e) Surge Protection = 2.5KV (f) LED Driver should be complete with att standard portections as design of manufacturer. (g) Voltage operating range: 140-270V (h) THD = max 20% (j) Lumen Efficacy= min1800 Lumen (k) CCT=4000/6500 (CCT will be as per site requirement either 4000 or 6500)
Supply & fix, in replacement, LED Light Luminaire 25 Watt with 2500 or more lumen warm white, surge protection device upto 4KV, IP65 or more, IK07 or more, potted driver suitable for 120 to 270 V, 50 Hz & 100 lm /w light engine driver base pole adapter, powder coated pressure die cast aluminium with heat resistant toughened glass with lens type,GI pipe 40 mm dia medium Grade not less than with 1.2 m.long in any shape with 2 nos of pole fitting clamps made out of MS flat , nuts and bolts and painting with aluminum paint with the following specification:- (a) Weight - 2.8 kg (b) Current :- 0.120 A (c) Power factor:- ≥ 0.95 (d) CRI:- ≥70 (e) Surge Protection :- 4KV (f) LED Driver should be complete with all standard portections as per design of Manufacturer. (g) THD - ≤ 10 % (h) System Lumens -2600lm (j) Life (Hrs) :50,000 (k) CCT:- 6500k
Supply & fix, in replacement, LED Light Luminaire 45 Watt with 4500 or more lumen, warm white, surge protection device upto 4KV, IP65 or more, IK07 or more, potted driver suitable for 180 to 270 V, 50 Hz, light engine driver base pole adapter, powder coated pressure die cast aluminium with heat resistant toughened glass with lens type, GI pipe 40 mm dia medium grade not less than with 1.2 m. long in any shape with 2 nos of pole fitting clamps made out of MS flat , nuts and bolts and painting with two coats of aluminium paint over a coat of primer with the following specification:- (a) Weight- 2.8 kg (b) Current :- ≤ 0.215 (c) Power factor:- ≥ 0.95 (d) CRI:- ≥70 (e) Surge Protection :- 4KV (f) LED Driver should be complete with all standard protections as per design of Manufacturer. (g) THD - ≤ 10 % (h) System Lumens min 4850 lm (j) Life (Hrs) :- 50,000 (k) CCT:- 6500K
S&F in repairs LED Bulb 230V AC 7/9 watt cool day light 4000K heavy duty Base B-22 complere all as specified and as directed.
S&F in repairs LED Bulb 230V AC 10/12 watt cool day light 6500K heavy duty Base B-22 thred type or as required at site complere all as specified and as directed.
S&F in repairs LED Bulb 230V AC 9 watt cool white light 6500K heavy duty thred type, LED BULB MOTION SENSINGB22 or as required at site complere all as specified and as directed.
S&F decorative wall light fitting made up of Polycarbonate ,Cylindrical shape ,with LED lamp 9 Watt complete with fixing arrangements on wall complete all as specified and as directed
Supply, fixing and connecting LED top post lantren, decorative luminaire with diffuser, 240 volts, 50 Hz, 25 watts with mounting arrangement incl taking down of existing fitting complete all as specified and as directed.
Supply, laying or fixing or passing through pipe commissioning and testing of PVC XLPE insulated, armoured heavy duty, electric cable with aluminium conductor, 1100 volts grade, multi -stranded of Size 16 SQMM 4 CORE including suitable size lugs including taking out /dismantling of existing cable and making good serfaces after laying of cable. Note: Earth work if required is included in taking down and No additional payment shall be made in this account to the contractor.
Supply, laying or fixing or passing through pipe commissioning and testing of PVC XLPE insulated, armoured heavy duty, electric cable with aluminium conductor, 1100 volts grade, multi -stranded of SIZE 25SQMM 4 CORE including suitable size lugs including taking out /dismantling of existing cable and making good serfaces after laying of cable. Note: Earth work if required is included in taking down and No additional payment shall be made in this account to the contractor.
S&F in replacement of sheet steel enclouser distribution boards, double door factory made VTPN 4 way 3 phase 415 volts 4 way with 200 amps rating copper bus bar and PVC insulated copper jumpers of suitable size from the MCCB to the out going circuits one incoming MCCB 100 amps and MCB TP 63 A -02 Nos,MCB SP -04 Nos circuits comprising of 3 phase 4 wire of suitable rating complete all as specified and as directed.
Supply, laying & fixing double wall corrugated (DWC) pipes of size 50 mm outer dia and 38 mm inner dia made of high density polythyline (HDPE) with all accessories i.e. all type of joints, Sockets, Elbows, bends and End caps etc. complete all as specified and as directed.
Taking down the old fitting 2x2 feet or 1x1 feet from ceiling safely and refixing the same as per site requirement after minor repair/replacement of suitable driver complete all as required and as directed at site
Supply & Fixing in repair sheet metal enclosure MCB DB double door [Acrylic], single pole and neutral, 240 volts, 8 way with 200 Amp, 10 KA breaking capacity rated bus bar with blanking plate wherever required and IP-43 degree protection complete all as specified and as directed.
Supply & Fixing in repair sheet metal enclosure MCB DB double door [Acrylic], single pole and neutral, 240 volts, 4 way with 200 Amp, 10 KA breaking capacity rated bus bar with blanking plate wherever required and IP-43 degree protection complete all as specified and as directed.
Supply & Fixing in repair sheet metal enclosure MCB DB double door [Acrylic], single pole and neutral, 240 volts, 12 way with 200 Amp, 10 KA breaking capacity rated bus bar with blanking plate wherever required and IP-43 degree protection complete all as specified and as directed.
S&F in replacement sheet metal enclosure MCB DB double door [Acrylic], Triple pole and neutral, 440 volts, 4 way with 200 Amp, 10 KA breaking capacity rated copper bus bar with blanking plate wherever required and IP-43 degree protection complete all as specified and as directed.
S&F in replacement MCB Triple Pole and Neutral 63 Amps,415 V ,10KA breaking capacity complete all as specified and as directed.
S&F in replacement MCB Single Pole and Neutral 240Volt, 40 Amps,10KA breaking capacity complete all as specified and as directed.
S&F in replacement MCB Single Pole and Neutral 240Volt, 63 Amps,10KA breaking capacity complete all as specified and as directed.
S&F in replacement MCB Single Pole 240Volt, upto 40Amps,10KA breaking capacity complete all as specified and as directed..
Supply & Fixing in repair single pole and netural sheet metal enclosure with a two pin and earth plug and socket complete with 01 number single pole MCB 20 Amps complete all as specified and as directed.
Supply only in replacement of ball bearing of 6201/120 for ceiling fan/ exhaust fan of any size and make complete all as specified and as directed.
All as described in Srl Item No 84 above, but for 6202/115
All as described in Srl Item No 84 above, but 6203/117 complete.
All as described in Srl Item No 84 above, but 6204/118 complete.
Supply and fixing in replacement of condenser 2.5 MFD of apporved make for ceiling fan complete all as specified and as directed.
All as described in Srl Item No 88 above, but 4.0 MFD for exhaust fan complete all as specified and as directed.
Supply and fixing in replacement of self lubricating bush of gun metal of same make for ceiling fan/exhaust fan complete all as specified and as directed.
Supply and fixing in replacement of shaft of approved quality for ceiling fan/Exhaust fan any make and type & size complete all as specified and as directed.
S&F in replacement of split pin suitable for ceiling fan/ exhaust fan any make and type & size complete all as specified and as directed.
Supply and fix and connecting heating element (triangular or circular base type) 1.5 KW 230 volts suitable for 25 ltrs capacity geysers in replacement of old unserviceable heating element complete all as specified and as directed.
Supply and fix and connecting heating element ( triangular or circular base type) 2 KW, 230 volts suitable for 50 ltrs capacity geysers in replacement of old unserviceable heating element complete all as specified and as directed.
S&F brass chromium plated flexible pipe connection heavy duty suitable for hot water supply with two Nos brass chromium plated union 450 mm long in replacement of PVC pipe connection complete all as specified and as directed.
S&F three pin top 15 Amp 240 volts complete all as specified and as directed.
Supply and fixing FR PVC insulated, Heavy duty, unsheathed single core flexible copper conductor cables of 1100 Volt grade, conforming IS 694 with latest ammendment and ISI marked in different colour of following sizes.
(a) 1.5 Sq mm
(b) 2.5 Sqmm
(c) 4.0 Sqmm
(d) 6.0 Sqmm
S&F in repairs rubber reel suitable for ceiling fan of any make and size complete all as specified and as directed.
S&F in repairs 15 mm bore GI pipe medium grade with all fitting and fixed complete for ceiling fan as down rod complete all as specified and as directed .
S&F three pin top 15 Amp 240 volts complete all as specified and as directed.
S&F three pin top 5 Amp 240 volts complete all as specified and as directed.
S&F for top for earth plug socket 20 Amps AC 240 Volts complete all as specified and as directed.
Supply and fixing pressed MS/GI steel terminal boxes not less than 1.22 mm thick for mounting switch, socket etc of appx size 100 mm x 100 mm x 50 mm complete all as specified and as directed.
Supply and fixing pressed MS/GI steel terminal boxes not less than 1.22 mm thick for mounting switch, socket etc of appx size 175 mm x 100 mm x 50 mm complete all as specified and as directed.
Supply & fixing of garden light, LED Bollard in IP 65/IK 10 with base plate 9/10 W 240 volts and cylindrical shape with opal acrylic diffuser and including fittting clamps bolts etc and pcc work for base mounting all as specified and directed .
Supply and fixing Hylam brand mica laminated 3 mm thick sheet cover of size 125mmx125mm complete with cutting for suitable size for fixing swiches/socket all as directed at site.
Supply and fixing Hylam brand mica laminated 3 mm thick sheet cover of size 200mmx125mm complete with cutting for suitable size for fixing swiches/socket complete all as specified and as directed at site.
Supply and fixing Hylam brand mica laminated 3 mm thick sheet cover of size 275mm x 225mm complete with cutting for suitable size for fixing swiches/socket complete all as specified and as directed at site.
S&F the LED rechargeble emergency light min 7/9 watt slim ray sutable for 240 volts charging system complete with all respect all as required complete all as specified and as directed at site.
S&F the remote bell Ac 230 volts with switch and battery and fixing on site all as required complete all as specified and as directed at site.
S&F the bed side lamp light fitting with lamps with LED lamps 9/10/12 watt with glass covering complete all as specified and as directed at site
Supply and fixing the copper wire 3 core round with sheathed 2.5 sqmm all as required complete all as specified and as directed at site.
Supply and fixing the copper wire 3 core round with sheathed 1.5 sqmm all as required complete all as specified and as directed at site.
titiksha india (BID ID -3438784)
kiran electrical and hardware centre (BID ID -3444343)
TRISHLA CONSTRUCTIONS (BID ID -3439448)
ANAMIKA CONSTRUCTION (BID ID -3439512)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .