Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.1 LAccepted-AOC | L1 | Accepted-AOC Awarded being lowest bidder | |
| 2 | L2₹40.8 L+₹4.9 L (13.8%)Rejected-AOC | L2 | Rejected-AOC Other than lowest bidder | |
| 3 | L3₹41.4 L+₹5.6 L (15.5%)Rejected-AOC H NO 1366 3 GALI NO 6 MATA ROAD NEAR HAPPY MODEL SCHOOL RAJIV NAGAR GURGAON 122 001 HARYANA | GURGAON | GURGAON | HARYANA | 122001 | L3 | Rejected-AOC Other than lowest bidder | |
| 4 | L4₹60.6 L+₹24.8 L (69.1%)Rejected-AOC C 223 MIANWALI COLONY GURGAON 122001 HARYANA | GURUGRAM | HARYANA | 122001 | L4 | Rejected-AOC Other than lowest bidder | |
| 5 | Rejected-Technical INDEX NO B 107 HQ CE WC 234 PKT 8 SEC 12 SURYODAYA APARTMENT DWARKA NEW DELHI 110078 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110078 | - | Rejected-Technical Rejected |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
29 May 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (P) AF Gurgaon
GE (P) AF Gurgaon NEAR ATUL KATARIA CHOWK GURGAON 122005
GE(P)AF/GUR-21/2021-22 REPAIR AND MAINTENANCE OF B AND R WORKS IN TECHNICAL AREA AT AF STN GURGAON UNDER GE (P) AF GURGAON
2021_MES_439522_1
GE(P)AF/GUR-21/2021-22
Open Tender
Civil Works
Item Rate
180 days
GE (P) AF Gurgaon
AS SPECIFIED IN NIT
10 documents required · 10 mandatory
₹500
GE (P) AF Gurgaon
₹98,000
Yes
4 Jun 2021
30 Apr 2021
31 May 2021
30 Apr 2021
29 May 2021
15 May 2021
60 days
Amount
Taking down existing bitumen felt roof treatment including cement mortar bedding and cleaning the surface and removal outside the MOD land, complete all as specified and as directed by Engr-in-charge. Note :- 1. Taking down earthing strips incl insulators from roof for treatment and re-fixing of same with existing specification in the same position after laid APP membrance including replacement of broken insulators, PVC rawl plus & screws etc are deemed to be inclusive of rate quoted by the contractor. 2. APP work shall be carried out on RCC PENT roof at 10 -12 mtr height (non accessible roof).
Demolition in cement concrete in any description and any position not other wise specified and provided as in ground floor and paving nexc. 15 cm thickness (below above ground floor) all as directed by Engr-in-Charge.
M&L for PCC (1:2:4) avg 50mm thick type B-0, using 12.50 mm graded mechanically crushed stone aggregates as in padding to roof to maintain the required slope and finished the surface even and smooth without using extra cement, complete all as specified and directed. Note:- PCC work shall be carried out on RCC PENT roof at 10 -12 mtr height (non accessible roof).
M&L for 10mm thick cement plaster on brick work or over roof surface in CM (1:4) mixed with WPC as per manufacturer’s instructions @ 0.50% by weight of cement on concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed. Note : 1. WPC shall be measured and paid separately. 2. Plaster work shall be carried out on RCC PENT roof at 10 -12 mtr height (non accessible roof).
M&L for water proofing treatment of roof consisting as under:- (a) Applying evenly a coat of bituminous primer conforming to IS-3384:1986 @ 0.30 litre/sqm including preparation of roof surfaces (b) Applying evenly a tack coat of industrial bitumen 85/25 @ 1.2 kg/Sqm on plaster surface all as specified. (c) A layer of 3mm thick APP polymeric membrane of weight not less than 3.00 kg/sqm, reinforced with polyester non-woven fabric (weight not less than 160gm/sqm), duly sealed at over laps & joints with end laps of the 10cm and side over laps of 7.5cm by flame (by torch application) all as per manufacturer’s instructions, complete all as specified and directed. Note:- 1. Necessary sacffolding and saftety precaution are deemed to inclusive the quoted rate by the contracotor. 2. APP work shall be carried out on RCC PENT roof at 10 -12 mtr height (non accessible roof).
Supply only water proofing liquid compoundcomplete all as specified and directed by Engr-in-Charge. :Make : DR. FIXIT PIDE PROOF LW, CICO, FOSROC.
M&L Appling one coat Bitumen water proofing aluminium heat resistance paint on the roof as per manufacture instructions complete all as specified and directed by Engr-in-Charge. Make : PLASCON/PLASCON or out of make as specified in list. Note:- Paint work shall be carried out on RCC PENT roof at 10 -12 mtr height (non accessible roof).
Dismantling of brick work built in cement mortar including all qoins, arches, pillars, etc.complete all as specified and as directed by Engr-in-charge.
M&L for Brick work with sub class B bricks straight or curved on plan exc 6 mtr mean radius built in CM 1:6 all as specified and directed by Engr-in-Charge.
All as per srl item No. 9 here in before but except bricks Note:- Serviceable bricks obatined from srl item No. 8 shall be re-used in srl item No 10 after cleaning etc complete all as specified and directed by Engr-in-Charge.
Taking down cement Plaster, any description on Brick Walls or on concrete Surfaces including raking out Joints, hacking for Key, scrubbing down with Water, etc., and removing same from the Site(s), complete all as specified and as directed.
M&L for for rendering 15mm thick in CM 1:6 on brick work or concrete surfaces other than fair face of brick work, finished fair & even w/o using extra cement in patches with water proofing compound(water proofing compound paid sepratelly in item) all as specified and directed by Engr-in-Charge.
M&L preparetion of new plastered surface applying two coat of weather proof exterior grade acrylic emulsion paint in camoflauge pattern as per approved pattern over one coat of approved primer including necessary scaffolding all as specified and directed by Engineer-in-Charge.
S&F PVC SHEET WALL PANELLING of thickness 5 mm consisting of panels of desired sixe stuck on inner frame work of 50mm wide strips of 5 mm thick Prelam PVC Sheet. The panel & strips shall be Manufactured by an ISO-9001-2008 certified Company. The strips should have in their center grove of 6 mm wide and 1 mm depth for sinking the head of the screw used to fix the strips to the wall vertially at an equal interval of 10" between two PVC strips. The PVC strips shall be fixed to the wall using 65 mm long MS Screws through the groove in the strips by using PVC fasterners. The distance between two screw shall bot be more than 200mm. A groove of 2mm may be left at the joint of two panels for aesthetic looks. The exact size of the panel and correspondingly of the grid may vary depending on the size of the wall. Optionally a strps of 5 mm thick PVC sheet of width 75 mm feathered at the edges shall be stuck at the places where two panels are joined, using solvent cement all as specified including dismantling of existing and directed by Engr-in-Charge.
Taking down Chowkhats or frames exc 10 sqm each without taking of shutter from the frame all as specifed and directed by Engr-in-Charge.
S&F polyester powder coated aluminium frame/chowkhat for door shutter of section 101.0x44.4 mm of gauge 16 fixed in brick masonery or conrcrete work by necessary drilling and rawl plug aggangement etc incl S&F polyester powder powder coated aluminium door shutter top rail and middle rail of section 85x44.4 of 16 gauge and bottom rail of section 150x44.4 mm 16 gauge (all section of such type having arrangement for fixing glass/prelaminated board/aluminium composite panel on one or both sides as required) incl aluminium fittings such handle (2 Nos each shutter), tower bolt, locks (mortise type lock) glazing clips, rubber packing, anodised aluminium snap beading screw, hinges type B-21 150mm long (3 Nos each shutter) etc and one door stopper two legged with each leaf (shutter) complete (Glass and prelaminated board/ alumionum sheet to be measured separately under appropriate item of sch A) complete all as specified and directed by Engr-in-Charge (Make of aluminium section shall be hindalco/Jindal or out of make as specified in list).
M&L, for 5 mm thick aluminium sheet, exterior grade fixed between aluminium section with and including snap fitting aluminium clips of polyester powder coated along with rubber gasket, complete all as specified and directed by Engr-in-Charge. Note:- Rubber gasket shall be measured and paid separately.
S&F in repair rubber beading heavy duty good finished fixed around the board/ glass complete all as specified and as directed by Engineer-in-Charge.
M&L for fabrication of aluminium compositre panel of 4mm thick with .5 mm aluminium core/skin as a tap and bottom layer, middle ;ayer 3mm thick of polythincore (LDPE) and finally with PVDF coating 28 to 32 micron and joints filed with silicon sealant and including aluminium frame of section 37.5mm x 25mm x 1.6mm fixed on the wall/ columns as a cladding and on ceiling of steel structure/ RCC celing withscrew complete incl dismantling of old decayed panels all as directed and as per manufacture's instruction, coloured/texture pattern as in repair complete all as specified and as directed by Engineer-in-Charge.
Demolition of RCC as in slab, beam, chajja (other than ground floor) beams staircases,and similar complete all as specified and as directed by Engineer-in-Charge.
M&L for Reinforced cement concrete M-25 nominal mix using 20mm graded aggregate as in chajjas and similar works complete all as specified and as directed by Engineer-in-Charge.
M&L for Formwork to chullah hoods, chajjas, troughs and similar items including edges complete all as specified and as directed by Engr-in-Charge.
M&L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 5 cm but n exc 15 cm wide complete all as specified and as directed by Engr-in-Charge.
M&L for 6 to 8 mm dia TMT bars, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed by Engr-in-Charge.
All as per item No 24 here-in-before but in stirrups/binders complete all as specified and directed by Engr-in-Charge.
S&F mild steel 1.25 mm thick rolling shutter without ball baring but gear operated with bevel gear box and crank handle including top cover anchor rod, hasp and staple including in two partirtation (as reqd ), including high carban steel spring, locking device and etc including taking down old shutter complete all as directed by Engr -in Charge. Note:- 1. Necessary sacffolding and saftety precaution are deemed to inclusive in the quoted rate by the contracotor.
All as per srl item No. 26 here in before but without gear box all as specified and directed by Engr-in-Charge.
M&L for Preparation new steel surface exc 10 cm width/girth one coat red oxide primer and two coat synthetic enamal paint all as specified and directed bi Engineer-in-charge.
Note:- The amount of Rs 74,825/- against Schedule of Credit on Page No 130 shall be deducted from the total amount quoted against Sch 'A' while deriving the Contract Sum for Acceptance
SHAMMI ENTERPRISES
PAWAN KUMAR
M/S ujjwal associates
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .