Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.4 LAccepted-AOC | L1 | Accepted-AOC Lowest rate quoted | |
| 2 | L2₹45.4 L+₹1.0 L (2.28%)Rejected-Finance VILL P O MANKAR DIST BARDHAMAN PIN 713144 | MANKAR | BARDHAMAN | WEST BENGAL | 713144 | L2 | Rejected-Finance Highest rate quoted |
Tender Value
₹48.8 L
EMD Value
₹97,700
Closing Date
31 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE PANAGARH
GARRISON ENGINEER PANAGARH, MILITARY ENGINEER SERVICES, PO-PANAGARH, DIST-BURDWAN, WEST BENGAL, PIN-713420
All as per BOQ
2022_MES_499684_1
8400-737/E8
Open Tender
Civil Works
Works
180 days
PANAGARH
Class D, Cat a (i)
6 documents required · 6 mandatory
₹500
GE PANAGARH
₹97,700
Yes
8 Mar 2022
5 Jan 2022
3 Feb 2022
5 Jan 2022
31 Jan 2022
18 Jan 2022
60 days
Amount
Excavation in trenches (Soft/loose soil) n exc. 1.5m wide and n exc 1.5 m in depth for foundation etc. and getting out complete all as specified and directed.
Surface excavation n exc 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft and loose soil complete all as specified and directed.
M & L for removing excavated material exc. 250m but not exceeding 500m and depositing where directed complete all as specified and directed.
M & L for Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering as required complete all as specified and directed
M&L for providing plain cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundation and mass concrete complete all as specified and directed.
M & L for 100 mm thick cement concrete type D-2, 1:4:8 (40 mm graded stone aggregate) as in sub base complete all as specified and directed.
M & L for 75 mm thick cement concrete type C-2, 1:3:6 (40 mm graded stone aggregate) as in plinth protection complete all as specified and directed.
M & L for 40 mm thick cement concrete type B-1, 1:2:4 (20 mm graded stone aggregate) as in floors , subfloors complete all as specified and directed.
M&L for RCC M-25 (Design Mix) (using 20mm graded stone aggregate) as in, footings, foundation rafts ,foundation beams, plinth beams , bases of columns etc, complete all as specified and as directed.
M&L for RCC M-25 (Design Mix) (using 20mm graded stone aggregate) as in, Slabs supported on walls, beams and columns in floors, roofs, landings, balconies,canopies, deck slabs and in shelves and the like complete all as specified and as directed.
M&L for RCC 1:2:4 type B-1(using 20mm graded stone aggregate) as in,Columns, pillars, piers, posts and struts etc, complete all as specified and as directed.
M & L RCC M-25 (Design Mix), (using 20mm graded stone aggregate) for beams, cantilivers, beressummers, lintels over 1.5m span complete all as specified and directed
M & L for formwork to sides of concrete , foundations, footings, bases of columns, rafts and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work for fair finished surface complete all as specified and directed.
M & L for formwork to soffits of suspended slabs such as roof slabs, floors slabs, landings and similar work not exceeding 200mm thick (horizontal or sloping) for fair finished surface complete all as specified and directed.
M & L for formwork to sides and soffits of floor or roof beams, beam haunching, girders, bressummers, lintels, cantiliver shelves etc.for fair finished surface complete all as specified and directed.
M & L for formwork to sides of pillars, posts, struts, piers, columns and stanchions etc for fair finished surface complete all as specified and directed.
M & L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete raillings , opening in concrete walls, floors and roofs n exc 20cm wide and sides of RCC/PCC bands in walls, hozontal or sloping and similar work exc 5cm but n exc 10cm etc.for fair finished surface complete all as specified and directed
M&L for mild steel TMT bars 10mm dia and over as in stirrups and spacers, binders, cut to length, bent to shape required, incl cranking, bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
All as per item No 19.00 mentioned here-in-above but 6mm to 8 mm complete all as specified and directed.
M & L for Glazd ceramic coloured tiles 450x350x7 / 350x250x7mm thick in dado, set and jointed in neat cement slurry and pointed in colour cement to match including rendering 10mm thick in cement mortar 1:4 complete all as specified and as directed .
M & L for non skid ceramic coloured tiles of 7 to 8 mm thick (Square/rectangular) area of each tile exc 0.11sqm but nexc 0.18 sqm, in floors etc.set and jointed in neat cement slurry and pointed in white/coloured cement to match with the existing and including cement screeding 15mm thick in cement mortar 1:6 complete all as specified and as directed (Make- Somany/Orient/Johnson).
M&L for sand bed 50 mm thick for laying of interlocking floor finishing complete all as specified and directed
M&L for 75mm thick PCC 1:4:8 type C2 using 20mm graded stone agg as in sub base complete all as specified and directed.
M&L for machine pressed concrete interlcking paver blockany shape and size confirming to IS-15658-2006 of 60mm thickness, M-35 Grade set with grey cement and pigment complete all as specified and directed.
S&F pre-cast concrete blocks for kerb stone with solid block exc 10 cm in width type C-1 , 1:3:6 ( using 20 mm graded stone aggregate) set in CM 1:6 of any shape and size as approved by Garrison Engineer, including necessary excation and earth work including returning filling in the erarth and removal of surplus earth from site if any, kerb stone shall be fixed in true line and level or in curves for edging of road side path including embedding PCC pre cast block in ground to any depths as required and tamping soil around PCC bloacks complete all as specified and directed at site.
S & F cast iron soil, waste and vent pipes( sand cast pipes) 100 mm bore in any length with or without ears, with cement joint laid in trenches or in floors complete all as specified and directed.
S & F cast iron soil, waste and vent pipes( sand cast pipes) 75 mm bore in any length with or without ears, with cement joint laid in trenches or in floors complete all as specified and directed.
S & F bends 100 mm size dimnishing pieces or tapers (larger bore measured) complete all as specified and directed.
S & F bends 75mm size dimnishing pieces or tapers (larger bore measured) complete all as specified and directed.
S & F CI cowels 75 mm bore complete all as specified and directed.
M & L for Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in cement mortar (1:6) complete all as specified and directed
M & L for Brickwork with fly ash bricks, straight or curved on plan to any radius in half bricks thick walls, built in cement mortar (1:4) complete all as specified and directed.
M&L for rendering 15 mm thick in CM (1:4) using water proofing compound on fair faces of brick work or concrete surfaces etc finished even and smooth without using extra cement (water proofing compound to be measured and paid seperately) including necessary scaffolding if required complete all as specified and directed.
M&L for rendering 15 mm thick in CM (1:6) on other than fair faces of brick work or concrete surfaces etc finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 5 mm thick in CM (1:3) on brick or concrete surfaces in ceiling etc finished even and smooth without using extra cement complete all as specified and directed.
Supply only liquid water proofing compound make - pdilite or equivalent complete all as specifed and directed by the Engr-in-Charge.
M & L for applying three coats of white wash on newly plastered surfaces of walls including preparation of surfaces complete all as specified and directed
M & L for applying white wash three coats on newly plastered surfaces of ceiling including preparation of new surfaces for matching with repaired surfaces complete all as specified and directed.
M & L for applying two coat of cement base paint (weather proof) over one coat of primer including prepration of newly platered surface complete all as specified and directed.
S & F of 20mm outer dia CPVC pipes SDR 11 & plain CPVC SDR 11 fittings in trenches complete all as specified and directed
S&F PVC connection 15mm dia of standard pattern 450mm long, with two Nos brass check nuts (adopts) and washers etc complete all as specified and directed
S & F cast iron floor trap including jointing to waste pipe in run lead, dia of outlet 75mm, complete all as specified and directed.
S&F vitreous china squatting pan (Orissa pattern) long pan including provision of lime concrete bedding fixed in repair size 580x440mm white with intergral footrest with 'P' or 'S' trap complete (excluding flushing cistern and flush) complete all as specified.
S & F 15 mm brass chromium plated shower rose 125mm size of any colour for fixing with 15mm pipe complete all as specified and directed.
S&F PVC Low level flushing cistern 10 ltr capacity incl internal fittings,sypons,handle,bend etc complete incl 2 Nos CI brackets, waste pipe and coupling complete all as specified and directed.
S & F 125mm dia grating doom with waste hole of PTMT (Minimum weight 40 gms) fixed in cement mortar (1:3) complete all as specified and directed.
S & F for vitereous china bowl urinal half stall type, complete including providing and fixing plus, bedding urinal against wall in cement mortar 1:2 securing urinal to plus with and including 60mm long brass screws, pointing around urinal back in cement, fixing automatic flushing cistern with brackets, flush pipe, grating and union for discharge pipe complete all as specified and directed.
S&F flush pipe of polyethylene of low or high density of PVC, 32 mm dia, for low level cistern complete all as specified and directed.
S & F 150mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and directed.
S & F extruded aluminum alloy handles fabricated type and anodised of size 150mm, complete all as specified and directed.
S & F Sliding door bolts, aluminum anodised with hasp and stapple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolt and sliding bolts of extruded sections, length of bolt sliding 300mm long complete all as specified and directed.
S & F stainless steel butt hinges medium weight stainless steel and fixed 100mm size complete all as specified and directed.
S&F factory made solid PVC moulded door shutter, 28 to 30 mm thick (Stiles), with 2,4 or 6 raised panel design with 2 mm thick Moulded PVC sheet on the front face and 2 mm plain color PVC sheet on back face supply and fixing in frame at site as per specification and drawing complete all as specified and directed.
S&F solid door frame 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube complete all as specified and directed.
S&F steel ventilators/ window with side hung shutters including box type hinges with steel handles and steel peg stay complete with glazing bars, devotailed or welded complete with one shop coat of zinc crome primer complete all as specified and directed.
M & L for 3mm thick sheet glass ordinary quality and glazing with oil putty in square n exc 0.50 Sqm in each panes complete all as specified and directed.
S&F stainless steel wire cloths 0.36 mm nominal dia of wire and average width of aperature is 1.40 mm and fixed with tinned tacks or galvanised wire staples complete all as specified and directed
S & F Framed work such as grills gratings end of bars shoulders and or riveted, or forged into spikes; framed Guard bars and similar works conforming to Fe-290. Gde-E-165 complete all as specified and directed.
Supplying and laying of Eco drain Hi-tech pipe dranage sewer system pipe bearing 160 mm dia minimum 4mm thick including jointing with couplar ,bend tee as per site requerement complete laid in trenches or floors complete all as specified and directed.
M&L for cement concrete (1:4:8) type D2 using 40mm graded stone aggregates incl packing under and haunching against the sides for 150mm internal dia SGSW pipes after they are laid and tested complete all as specified and directed. (Note: thickness of concrete bed 100mm).
M&L for applying two coats of synthetic enamel paint over a coat of red oxide on steel surfaces of any description complete all as specified and directed.
S & F 15 mm stop/angle valves brass copper alloy, high pressure externally threaded for 15mm bore pipes complete all as specified and directed.
S & F 15 mm bore Pillar Taps cast copper alloy, with capstan heads, chromium plated, (fancy type) screwed down high pressure with or without lettered 'Hot or Cold' with long screwed shanks and fly nuts, screwed for iron pipe and fixed complete all as specified and directed.
S&F vitreous china ware white wash hand basin with flat back size 550 X 400 mm excluding tape waste chain and plug and procelain stopper but including brackets complete all as specified and directed.
S & F bib tap cast copper alloy chromium plated fancy type with crutch or butterfly handle screwed down screwed for iron pipe and fixed to 15mm bore pipe complete all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and getting out soft/loose complete all as specified and directed
Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick spread, levelled and rammed including watering complete all as specified and directed
M & L for Cement concrete (1:3:6) Type C2 using 40 mm graded aggregates as in foundations, filling and mass-concrete complete all as specified and directed.
M & L for Brickwork with flyash bricks, straight or curved on plan exc 6m mean radius, built in CM (1:4) complete all as specified and directed
M & L for PCC (1:2:4) Type B0 using 12.50 mm graded aggregate used as in copings complete all as specified and directed.
M & L for precast RCC (1:2:4) type B1 using 20 mm graded aggregates as in Cover Slabs set in CM 1:6 complete all as specified and directed.
Mild steel TMT bars 6 to 8 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Removing excavated spoil to a distance not exc.50m and depositing where directed at a level not exc. 1.5 m above the starting point complete all as specified and as directed.
S & F Low density polyethylene pipes (LDPE) of 50 mm bore of pressure rating 6 kgf/cm2 laid in trenches as in weep holes complete all as specified and directed
Supply, Laying and Testing of Reinforced concrete pipes class NP2 , laid and jointed complete with collars 150mm bore complete all as specified and as directed.
M&L for PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in bed to drain pipes including forming cradels for 150 mm bore pipes complete all as specified and as directed
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, mounds, mitred/stopped end etc complete all as specified and directed.
Add or deduct for each 25 mm girth or part thereof over or under 30 cm ditto complete all as specified and directed
M & L for sand filling under floors or in foundation including watering and consolidation complete all as specified and directed
M & L for TMT bars 5mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 10mm dia in stirrups, spacers and binders complete all as specified and directed.
M & L for reinforced cement concrete (Design Mix) M-25 (20mm graded stone aggregate) in columns, pillars, piers, etc complete all as specified and directed.
M & L for preparation of new surfaces of roof and applying two coats of Polyurethane (PU) acrylic based water proofing liquid compound over and including one coat of self priming primer @ one litre per 10 Sqm with reinforcing fabric sheet as per manufacturer's instructions to stop leakage/seepage from roof/wall complete all as specified and as directed by the Engr-in-Charge (Notes :- (i). As per description of this item, minimum two coats of Polyurethane (PU) acrylic based water proofing liquid compound over one coat of primer shall be carried out as per manufacturer's instruction. Please note no price adjustment shall be made, if as per manufacturer's instructions more coats of Polyurethane (PU) acrylic based water proofing liquid compound and primer are required for roof treatment. (ii). Quoted Rate shall be deemed to be included for work in building/structure of any height).
M&L for brickwork with old size fly ash bricks straight or curved on plan to any radius built in CM 1:4 complete all as specified and directed
M&L for finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) including preparation of newly plastered surface of concrete complete all as specified and directed.
M&L for broken bricks hard core gauge n.exc 63mm deposited, spread and levelled in layers n.exc 15cm thick, watered and rammed to a true surfaces complete all as specified and directed.
M&L for providing 100 mm thick PCC 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in sub base of flooring complete all as specified and directed.
M & L for 20 mm thick screed bed or bedding layer in cement mortar 1:6 complete all as specified and directed.
M & L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
Removing surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
S & F Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed with 2nd class Hardwood complete all as specified and directed.
S&F Plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats with 1st class Hardwood complete all as specified and directed.
S&F Anodised powder coated aluminium frame for doors,windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
S&F Anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified and directed.
S & F Sheet glass 5.5 mm thick, ordinary quality and glazing with oil putty in square n exc 0.5 sq.m in each pane complete all as specified and directed.
M&L for PCC (1:2:4) type B-0 (using 12.5mm graded stone aggregate) as in bed blocks for hold fast including necesssary formwork complete all as specified and directed.
S & F mild steel flat iron as in hold fast, clamps articles conforming to FE 290 Gde-E-165 complete all as specified and directed.
S&F 200 mm long Aluminium, anodised, barrel tower bolt of extruded section complete all as specified and directed.
S & F 100 mm size butt hinges extruded aluminium alloy with galavanised mild steel hinge pin anodised and fixed type C-21 complete all as specified and directed.
S&F 200 mm long Aluminium, anodised, barrel tower bolt of extruded section complete all as specified and directed.
S&F aluminium handles, cast type, anodised 150mm long complete all as specified and directed.
S & F 300 mm long Aluminium alloy, anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast Aluminium alloy and fixed complete all as specified and directed.
S&F capacity 1000 Ltrs rotational moulded polyethylene water storage tanks (Cylindrical, vertical with closed top with three layered) confirming to relevent IS complete including provision of all inlet outlet overflow and drain pipe fitting complete all as specified and directed by Engineer in Charge
Supply and fixing of high pressure PTMT float valve with epoxy coated alluminium rod and high density polythelene ball screwed for iron pipe 25 mm dia with fly nut complete all as specified and directed.
M&L for 25 mm bore gate valve cast copper alloy screwed down high pressure with clutch handle screwed both ends for Iron pipe complete all as specified and directed.
M&L for 25 mm bore GI Tubing medium grade in Trenches/ Floor/Pillar and connection including fitting like socket /Union/Tee/Reducer Nipple etc complete required will be supplied by Contractor rate for the same is included in the item rate quoted complete all as specified and directed.
E/M PORTION M&L for point wiring for light point/ fan point, one light/fan/exhaust fan point controlled by one, one way switch using 1.5 sqmm nominal cross sectional area multistranded copper conductor ,PVC insulated unsheathed FRLS cables in and including 20 mm dia or higher size PVC concealed conduits and fittings of medium grade, including pressed steel terminal switch boxes, 3 mm thick bakelite sheet top cover (ISI Marked) fitted with chromium plated brass screws & washers and 1.5 sqmm nominal cross sectioanl area multistranded copper conductor FRLS PVC insulated unsheathed earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed.
All as per item N 108.00 mentioned here-in-above but One 3 pin 5 Amps socket out let points on independent board complete all as specified and directed
M&L for wiring for 15 Amps socket out let on independent Boards controlled by one, one way switch using 4.0 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLS cables in and including 20 mm dia or higher size PVC concealed conduits and fittings, including pressed steel terminal switch boxes , 3 mm thick bakelite sheet top cover (ISI Marked) fitted with Chromium plated brass screws & washers and 2.5 sqmm nominal cross sectioanl area multistranded copper conductor , PVC insulated unsheathed FRLS cable earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified.
S&F switch piano flush type, single pole , 6 Amps, one way complete all as specified and directed.
S&F switch socket combination 2 in 1 multipurpose 5 pin , (6 Amps) flush type controlled by one switch complete all as specified and directed
S&F switch socket combination 2 in 1 , 6 pin , (16 Amps ) flush type controlled by one switch complete all as specified and directed.
S&F ceiling rose surface bakelite 65 mm x 50 mm two to three terminal suitable for 230 Volts AC 6 Amps complete all as specified and directed.
S&F 18 W LED light fitting wall mounted batten 4'ft , extruded polycarbonate, enivromental friendly, heat sink provided for efficent heat dissipation and integrated electronic driver for 18 watt,6000K including necessary connection complete all as specified and directed.
S&F security light fittings 25 watts, minimumm lumen output 100 lumen/Watt, made up of pressure dia cast housing with prismatic polycarbornate diffuser and individual LED with secondary optic and IP65 including necessary connection complete and supply and fix 25 mm dia GI braket 90 cm with two Nos clamp nut and bolts complete with all accessories including connected with twin core twisted flexible copper conductor of suitable size complete all as specified and directed. (Make - Bajaj/Crompton/Phillips)
S&F epoxy powder coated sheet metal enclosure for DBs, double door, Single pole and neutral 240 V, 4 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact complete all as specified and directed.
S&F MCB SP, 6 to 32 Amps, 'C' series 10kA, 240 Voltsand to be housed in DBs including necessry connection complete all as specified and directed.
S&F MCB SPN 6-32 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs complete including necessry connection all as specified and directed.
M&L for earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI wire 4 mm dia as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth strip encased in and including 40 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS round bars 6mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SSR Part-I complete all as specified and directed and testing on completion.
S&F Matellic Exhaust ventilation fan of sweep 300mm complete all as specified and directed by Engr-in-Charge.
M&L for point wiring for light point/ fan point, one light/fan/exhaust fan point controlled by one, one way switch using 1.5 sqmm nominal cross sectional area multistranded copper conductor ,PVC insulated unsheathed FRLS cables in and including 20 mm dia or higher size PVC concealed conduits and fittings of medium grade, including pressed steel terminal switch boxes, 3 mm thick bakelite sheet top cover (ISI Marked) fitted with chromium plated brass screws & washers and 1.5 sqmm nominal cross sectioanl area multistranded copper conductor FRLS PVC insulated unsheathed earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed.
All as per item No 122.00 mentioned here-in-above but 3 pin, 5 Amp socket on same board with other switches complete all as specified and directed
S&F socket outlets 2 in 1, 3 pin, 5/6 Amps flush type230/240 V complete all as specified and as directed. ( For Same Board only)
M&L for wiring for socket outlet 3 pin, 15 amps on independent Boards controlled by one, one way switch using 4.0 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLS cables in and including 20 mm dia or higher size PVC concealed conduits and fittings, including pressed steel terminal switch boxes , 3 mm thick bakelite sheet top cover (ISI Marked) fitted with Chromium plated brass screws & washers and 2.5 sqmm nominal cross sectioanl area multistranded copper conductor , PVC insulated unsheathed FRLS cable earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed.
S&F switch socket combination 16 Amps, 6 pin , 2 in 1, flush type controlled by one switch complete all as specified and directed.
S&F switch piano flush type, single pole , 6 Amps, one way complete all as specified and directed.
S&F two single core ,6 sqmm nominal cross sectional area multistranded copper conductor FRLS cable, PVC insulated unsheathed 1100 Volts grade drawing in and including nd including suitable size PVC conduit (ISI marked), concealed, including 6 sqmm nominal cross sectional area multistranded copper conductor FRLS cable, PVC insulated unsheathed 1100 Volts grade earth wire complete all as specified and directed.
S&F ceiling rose surface bakelite 65 mm x 50 mm two to three terminal suitable for 230 Volts AC 6 Amps complete all as specified and directed.
S&F 18 W LED ultra slim light fittings, lighting fixture with extruded polycarbonate complete with all accessories and connection from ceiling rose with twin core twisted flexible copper conductor cable with suitable size and earthing complete all as specified and directed.
S&F security light fittings 25 watts, minimumm lumen output 100 lumen/Watt, made up of pressure dia cast housing with prismatic polycarbornate diffuser and individual LED with secondary optic and IP65 including necessary connection complete suitable for pole dia 25mm complete with all accessories including connected with twin core twisted flexible copper conductor of suitable size complete all as specified and directed. (Make - Bajaj/Crompton/Phillips)
S&F epoxy powder coated sheet metal enclosure for DBs, double door (when MCBs to be used), Single pole and neutral 240 V, 8 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact complete all as specified and directed.
S&F MCB SP, 6 to 32 Amps, 'C' series 10kA, 240 Voltsand to be housed in DBs including necessry connection complete all as specified and directed. (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating).
S&F MCB SPN 32 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs complete including necessry connection all as specified and directed. (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating).
S&F XLPE insulated armoured cable, 16 sqmm 2 core,1100 volts grade heavy duty cable,ISI marked passing through pipe, with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed complete all as specified and directed.
Excavation in trenches not exceeding 1.5m wide and not exc. 1.5m depth and getting out in hard/dense soil complete all as specified and as directed.
Removal of excavated soil to a distance not exc 50 m and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
S&F for dry river sand filling for cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying complete all as specified and as directed. (Note : Punned thickness shall be measured).
M&L for sub class B bricks locally available of size 25 x 12.5 x 7.5 cm laid dry width wise across the line of cable in trenches for protection of UG cable complete all as specified and directed.
M&L for earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI wire 4 mm dia as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth strip encased in and including 40 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS round bars 6mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SSR Part I complete all as specified and directed and testing on completion. Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
Supply, laying / fixing / connecting, testing and commissioning of LT under ground cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cable (heavy duty) with multistranded aluminium conductor,1100 Volts grade in trenches/on wall/poles laid in ducts/inside protection pipe of the following cross sectional area including cable glands,lugs and suitable size of MS saddle clips (where ever cable laid in ceilings / walls without cable duct) all as directed by the Engr-in-Charge for the following ratings Note:- (i) Excavation,sand cushioning,brick will be measured and paid separtely. (a) 10 Sqmm x 2 core
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cables, pipes etc. and getting out including trimming the sides and forming bottom surfaces to required levels in soft/loose soil complete all as specified and directed.
Removing excavated material (soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
M&L for river sand, washed and screened dry for cushioning to under ground cable in trenches below and around under ground cable including spreading and levelling complete as specified and directed . (Note :- Punned thickness 18 cm shall only be considered for payment)
M&L for Supply and lay in trenches fly ash bricks, for cable protection all as specified and directed by the Engr-in-Charge.
S&F Pipes galvanized, 50 mm bore “light grade”, supplied and laid complete including necessary fittings such as tees, bends, elbows, sockets, reducers etc as per site requirement or complete all as specified and directed.
ANIMA ENTERPRISE
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .