| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹1.2 LQualified Make: HI TECH WATER TREAT MENT PLANT
Model: HI TECH WATER TREATMENT PLANT 00 VIBHAV NAGAR COLONY NAVIPUR KALAN NAVIPUR KALAN HATHRAS UTTAR PRADESH 204101 | HATHRAS | UTTAR PRADESH | 204101 | Make: HI TECH WATER TREAT MENT PLANT
Model: HI TECH WATER TREATMENT PLANT | L1 | Qualified | |
| 2 | Disqualified Make: BHARTI
Model: BHARTI IRP ARP HP 1 20 SSI 2ND FLOOR INDUSTRIAL AREA G T KARNAL ROAD DELHI DELHI DELHI 110033 | NORTH DELHI | DELHI | 110033 | Make: BHARTI
Model: BHARTI IRP ARP HP 1 | - | Disqualified | |
| 3 | Disqualified Make: HI TECH WATER TREAT MENT PLANT
Model: IRON REMOVER PLANT AQUA FRESH | Make: HI TECH WATER TREAT MENT PLANT
Model: IRON REMOVER PLANT AQUA FRESH | - | Disqualified | |
| 4 | Disqualified Make: Tashi
Model: Tashi handpump IRP 64 OPP POLICE LINE J N ROAD RUIGANJ KAMPTEE NAGPUR MAHARASHTRA 441001 | NAGPUR | MAHARASHTRA | 441001 | Make: Tashi
Model: Tashi handpump IRP | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
6 Sept 2018, 7:00 pmClosed
Equipment for Iron/Arsenic/Fluoride Removal from Ground Water Equipment For Iron/Arsenic/Fluoride Removal From Ground Water ( 1 ) Technical Specifications * As per GeM Catalogue. Specification Specification Name Values Allowed Values TYPE Elements Removable Iron & Arsenic Removal Iron Removal
Iron & Arsenic Removal
Fluoride Removal
Iron & Fluoride Removal Water Source Ground Water from Overhead Tank Ground Water from Hand Pump
Ground Water from Tubewell
Ground Water from Overhead Tank Rated Discharge Capacity - Minimum (Liters/hr) 500 * Working Pressure (Minimum inlet Pressure) 5 * Prefilter Provided with Flushing Valve Yes Yes
No
NA Backwash required to remove the accumulated sludge
if any Yes * 1/7 Pumping required for Backwash Yes * Operation of Backwash Valve Automatic * Frquency of Backwash 500 * PH adjustment required Yes Yes
NA Regeneration of Removal media required No Yes
NA Removal Media Chemical Conform to International Standard NA * Total Weight of Base Media/Filter Media provided 5 * "Life of Base Media Filter Media on the basis of 10 hours of operation Per day at Rated discharge capacity" 1 0
1
2
3
4
5
6 Agreed to STC of the Product Yes * IRON REMOVAL UNIT Iron removal Technology Aeration
Oxidation and Filtration Aeration
Oxidation and Filtration
Catalytic Oxidation and Filtration
Adsorption and Ion Exchange
NA Chemical name of Iron Removal media NA * Maximum Iron Content of Inlet Water (ppm) 15 Any applicable numeric value Maximum Iron Content of Outlet Water @ Iron content of inlet water (ppm) 1 * Material of Iron removal Vessel Stainless Steel Mild Steel
Stainless Steel
UV Resistant FRP
NA Protective Coating for Iron removal Vessel Powder Coated Galvanized
Powder Coated
Polished
NA Number of Iron removal Vessels 1 * Diameter of Iron Removal Vessel 1000 * 2/7 Height of Iron Removal Vessel 1000 * Thickness of Iron Removal Vessel 10 * Total Weight of Iron Removal Media provided 5 * "Life of Iron Removal Media on the basis of 10 hours of operation Per day at Rated discharge capacity" 1 0
6 Cost of Iron Removal Media to treat 1000 Liters of water (Rs) 1 * Field testing kit provided for testing Iron conten No Yes
NA ARSENIC REMOVAL UNIT Arsenic removal Technology Sorption Technique Sorption Technique
Coagulation - Precipitation/Filtration (C/F)
Nano based Adsorption and co - precipitation
NA Chemical name of Arsenic Removal media NA * Maximum Arsenic Content of Inlet Water(ppm) 2 Any applicable numeric value Maximum Arsenic Content of Outlet Water @ Arsenic content of inlet water(ppm) 0.01 * Material of Arsenic removal Vessel UV Resistant FRP Structural Steel
NA Protective Coating for Arsenic removal Vessel Powder Coated Galvanized
NA Number of Arsenic removal Vessels 1 * Diameter of Arsenic Removal Vessel 1000 * Height of Arsenic Removal Vessel 2000 * Thickness of Arsenic 8 * 3/7 Removal Vessel Total Weight of Arsenic Removal Media Provided 5 * Life of Arsenic Removal Media on the basis of 10 hours of operation Per day at Rated discharge capacity 1 0
6 Availability of Toxicity Leaching Characteristic Procedure (TLCP) Certificate for Arsenic Removal media Yes * Cost of Arsenic Removal Media to treat 1000 Liters of water (Rs) 5 * "Field testing kit provided for testing Arsenic (inclusive in the scope of supply)" Yes Yes
NA FLUORIDE REMOVAL UNIT Fluoride removal Technology Chemical dosing Filtration Coagulation - Precipitation/Filtration
Chemical dosing/Filtration
NA Chemical name of Fluoride Removal media NA * Maximum Fluoride Content of Inlet Water(ppm) 4 Any applicable numeric value Maximum Fluoride Content of Outlet Water @ Fluoride content of inlet water(ppm) 1 * Material of Fluoride Removal Vessel UV Resitant FRP Structural Steel
UV Resitant FRP
NA Protective Coating for Fluoride Removal Vessel Powder Coated Galvanized
Electro Plated
NA Number of Fluoride removal Vessels 1 * 4/7 Diameter of Vessel 1000 * Height of Vessel 2000 * Thickness of Fluoride Removal Vessel 6 * Number of Dosing Pumps 1 * Total Weight of Fluoride Removal Media provided 5 * Life of Fluoride Removal Media on the basis of 10 hours of operation Per day at Rated discharge capacity 1 0
6 Chemical (s) required to treat 1000 Liters of water having 7 ppm Fluoride
In case of Chemical dosing
1 * Cost of Fluoride Removal Media Chemical (s)/Chemical (s) to treat 1000 Liters of water (Rs) 1 * In case of Chemical dosing
Period for which Chemical (s) supplied
as per STC (Inclusive in the scope of supply) 1 0
3 Field testing kit provided for testing Fluoride No Yes
NA TRIAL RUN WARRANTY Warranty 1 1
5 Installation & Commissioning Installation and Commissioning inclusive in the scope of supply * Trial Run and Training offered (inclusive in the scope of supply) 5 5
7
10
15
30 Availability of Test Reports from Central Govt/NABL approved/ILAC accredited Lab to prove conformity to the specification false true
false 5/7 If Yes
Test Report to be furnished to the Buyer on demand NA * Test Report No and Date - * Name of the Lab and Address - * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Arun Sharma 190011
O/o the Commandant
13th Bn. SSB Soura Srinagar J&K 1 15
492979
GEM/2018/B/69729
Equipment for Iron / Arsenic / Fluoride Removal from Ground Water
15 days
Jammu And Kashmir; Srinagar
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Equipment for Iron/Arsenic/Fluoride Removal from Ground Water Equipment For Iron/Arsenic/Fluoride Removal From Ground Water ( 1 ) Technical Specifications * As per GeM Catalogue. Specification Specification Name Values Allowed Values TYPE Elements Removable Iron & Arsenic Removal Iron Removal | - | - | - |
| Iron & Arsenic Removal | - | - | - |
| Fluoride Removal | - | - | - |
| Iron & Fluoride Removal Water Source Ground Water from Overhead Tank Ground Water from Hand Pump | - | - | - |
| Ground Water from Tubewell | - | - | - |
| Ground Water from Overhead Tank Rated Discharge Capacity - Minimum (Liters/hr) 500 * Working Pressure (Minimum inlet Pressure) 5 * Prefilter Provided with Flushing Valve Yes Yes | - | - | - |
| No | - | - | - |
| NA Backwash required to remove the accumulated sludge | - | - | - |
| if any Yes * 1/7 Pumping required for Backwash Yes * Operation of Backwash Valve Automatic * Frquency of Backwash 500 * PH adjustment required Yes Yes | - | - | - |
| NA Regeneration of Removal media required No Yes | - | - | - |
| NA Removal Media Chemical Conform to International Standard NA * Total Weight of Base Media/Filter Media provided 5 * "Life of Base Media Filter Media on the basis of 10 hours of operation Per day at Rated discharge capacity" 1 0 | - | - | - |
| 1 | - | - | - |
| 2 | - | - | - |
| 3 | - | - | - |
| 4 | - | - | - |
| 5 | - | - | - |
| 6 Agreed to STC of the Product Yes * IRON REMOVAL UNIT Iron removal Technology Aeration | - | - | - |
| Oxidation and Filtration Aeration | - | - | - |
| Oxidation and Filtration | - | - | - |
| Catalytic Oxidation and Filtration | - | - | - |
| Adsorption and Ion Exchange | - | - | - |
| NA Chemical name of Iron Removal media NA * Maximum Iron Content of Inlet Water (ppm) 15 Any applicable numeric value Maximum Iron Content of Outlet Water @ Iron content of inlet water (ppm) 1 * Material of Iron removal Vessel Stainless Steel Mild Steel | - | - | - |
| Stainless Steel | - | - | - |
| UV Resistant FRP | - | - | - |
| NA Protective Coating for Iron removal Vessel Powder Coated Galvanized | - | - | - |
| Powder Coated | - | - | - |
| Polished | - | - | - |
| NA Number of Iron removal Vessels 1 * Diameter of Iron Removal Vessel 1000 * 2/7 Height of Iron Removal Vessel 1000 * Thickness of Iron Removal Vessel 10 * Total Weight of Iron Removal Media provided 5 * "Life of Iron Removal Media on the basis of 10 hours of operation Per day at Rated discharge capacity" 1 0 | - | - | - |
| 6 Cost of Iron Removal Media to treat 1000 Liters of water (Rs) 1 * Field testing kit provided for testing Iron conten No Yes | - | - | - |
| NA ARSENIC REMOVAL UNIT Arsenic removal Technology Sorption Technique Sorption Technique | - | - | - |
| Coagulation - Precipitation/Filtration (C/F) | - | - | - |
| Nano based Adsorption and co - precipitation | - | - | - |
| NA Chemical name of Arsenic Removal media NA * Maximum Arsenic Content of Inlet Water(ppm) 2 Any applicable numeric value Maximum Arsenic Content of Outlet Water @ Arsenic content of inlet water(ppm) 0.01 * Material of Arsenic removal Vessel UV Resistant FRP Structural Steel | - | - | - |
| NA Protective Coating for Arsenic removal Vessel Powder Coated Galvanized | - | - | - |
| NA Number of Arsenic removal Vessels 1 * Diameter of Arsenic Removal Vessel 1000 * Height of Arsenic Removal Vessel 2000 * Thickness of Arsenic 8 * 3/7 Removal Vessel Total Weight of Arsenic Removal Media Provided 5 * Life of Arsenic Removal Media on the basis of 10 hours of operation Per day at Rated discharge capacity 1 0 | - | - | - |
| 6 Availability of Toxicity Leaching Characteristic Procedure (TLCP) Certificate for Arsenic Removal media Yes * Cost of Arsenic Removal Media to treat 1000 Liters of water (Rs) 5 * "Field testing kit provided for testing Arsenic (inclusive in the scope of supply)" Yes Yes | - | - | - |
| NA FLUORIDE REMOVAL UNIT Fluoride removal Technology Chemical dosing Filtration Coagulation - Precipitation/Filtration | - | - | - |
| Chemical dosing/Filtration | - | - | - |
| NA Chemical name of Fluoride Removal media NA * Maximum Fluoride Content of Inlet Water(ppm) 4 Any applicable numeric value Maximum Fluoride Content of Outlet Water @ Fluoride content of inlet water(ppm) 1 * Material of Fluoride Removal Vessel UV Resitant FRP Structural Steel | - | - | - |
| UV Resitant FRP | - | - | - |
| NA Protective Coating for Fluoride Removal Vessel Powder Coated Galvanized | - | - | - |
| Electro Plated | - | - | - |
| NA Number of Fluoride removal Vessels 1 * 4/7 Diameter of Vessel 1000 * Height of Vessel 2000 * Thickness of Fluoride Removal Vessel 6 * Number of Dosing Pumps 1 * Total Weight of Fluoride Removal Media provided 5 * Life of Fluoride Removal Media on the basis of 10 hours of operation Per day at Rated discharge capacity 1 0 | - | - | - |
| 6 Chemical (s) required to treat 1000 Liters of water having 7 ppm Fluoride | - | - | - |
| In case of Chemical dosing | - | - | - |
| 1 * Cost of Fluoride Removal Media Chemical (s)/Chemical (s) to treat 1000 Liters of water (Rs) 1 * In case of Chemical dosing | - | - | - |
| Period for which Chemical (s) supplied | - | - | - |
| as per STC (Inclusive in the scope of supply) 1 0 | - | - | - |
| 3 Field testing kit provided for testing Fluoride No Yes | - | - | - |
| NA TRIAL RUN WARRANTY Warranty 1 1 | - | - | - |
| 5 Installation & Commissioning Installation and Commissioning inclusive in the scope of supply * Trial Run and Training offered (inclusive in the scope of supply) 5 5 | - | - | - |
| 7 | - | - | - |
| 10 | - | - | - |
| 15 | - | - | - |
| 30 Availability of Test Reports from Central Govt/NABL approved/ILAC accredited Lab to prove conformity to the specification false true | - | - | - |
| false 5/7 If Yes | - | - | - |
| Test Report to be furnished to the Buyer on demand NA * Test Report No and Date - * Name of the Lab and Address - * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Arun Sharma 190011 | - | - | - |
| O/o the Commandant | - | - | - |
| 13th Bn. SSB Soura Srinagar J&K 1 15 | - | - | - |
Exempted
6 Sept 2018
18 Aug 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_492979.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .