Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.3 CrAccepted-AOC FLAT NO 03 PANCHAVATI BUILDING ADARSH NAGAR CHICALIM GOA 403711 | SOUTH GOA | GOA | 403711 | ₹2.3 Cr | L1 | Accepted-AOC Being lowest and reasonable tender |
| 2 | L2₹2.3 Cr+₹2.7 L (1.20%)Rejected-Finance MHN 284 DRIVER HILL VASCO DA GAMA GOA 403 802 | SOUTH GOA | GOA | 403802 | ₹2.3 Cr+₹2.7 L (1.20%) | L2 | Rejected-Finance Not being the lowest |
| 3 | L3₹2.5 Cr+₹24.0 L (10.6%)Rejected-Finance | ₹2.5 Cr+₹24.0 L (10.6%) | L3 | Rejected-Finance Not being the lowest |
| 4 | L4₹2.9 Cr+₹64.9 L (28.5%)Rejected-Finance | ₹2.9 Cr+₹64.9 L (28.5%) | L4 | Rejected-Finance Not being the lowest |
Tender Value
₹2.1 Cr
EMD Value
₹2.9 L
Closing Date
28 Dec 2021, 6:00 pmClosed
Cheif Engineer (Navy) Mumbai
HQ CE (NAVY) MUMBAI, 26, Assaye Buildings, Colaba, Mumbai-400005
PROVISION OF DEFICIENT SAILORS SINGLE LIVING ACCOMMODATION INCLUDING DINNING HALL AT INS MANDOVI, GOA
2021_MES_465786_2
87898/E8
Open Tender
Civil Works
Lump-sum
540 days
GE (P) Mandovi
As per tender documents
8 documents required · 8 mandatory
₹2,000
GE (P) Mandovi
₹2.9 L
Yes
4 Jan 2022
30 Nov 2021
30 Dec 2021
30 Nov 2021
28 Dec 2021
14 Dec 2021
Amount
SCHEDULE "A" Part - I (BUILDING WORKS) Total of Sch-'A' Part-I B/F from Serial Page No.25
SCHEDULE "A" PART-II (SITE CLEARANCE, AREA DEVELOPMENT, EXCAVATION & EARTHWORK) Total of Sch-'A' Part-II C/o B/F from Serial Page No.26
SCHEDULE "A" PART-III (INTERNAL ELECTRICFICATION) Total of Sch-'A' Part-III B/F from Serial Page No.29
SCHEDULE "A" PART-IV (INTERNAL WATER SUPPLY) Total of Sch-'A' Part-IV B/F from Serial Page No.31
SCHEDULE "A" PART- V (ROAD/PATH/CULVERT) Total of Sch-'A' Part-V B/F from Serial Page No.32
SCHEDULE "A" PART-VI (SEWAGE DISPOSAL) Total of Sch-'A' Part-VI B/F from Serial Page No.34
SCHEDULE "A" PART-VII (AREA DRAINAGE) Total of Sch-'A' Part-VII B/F from Serial Page No.36
SCHEDULE "A" PART-VIII (EXTERNAL ELECTRIFICATION) Total of Sch-'A' Part-VIII B/F from Serial Page No. 38
SCHEDULE "A" PART-IX (EXTERNAL WATER SUPPLY) Total of Sch-'A' Part-IX B/F from Serial Page No. 39
SCHEDULE "A" PART-X ( LIGHTNING PROTECTION ) Total of Sch-'A' Part-X B/F from Serial Page No.40
SCHEDULE "A" PART-XI ( COOLING APPLIANCES & WATER PURIFIER ) Total of Sch-'A' Part-XI B/F from Serial Page No.41
SCHEDULE "A" PART-XII (TELEPHONE CONDUITS) Total of Sch-'A' Part-XII B/F from Serial Page No.42
SCHEDULE "A" PART -XIII (MISCELLANIOUS ITEMS)
SITE CLEARANCE & EARTHWORK
Removal of excavated material (any type) and disposal of excavated material outside Ministry of Defence Land as directed .
INTERNAL ELECTRIC SUPPLY
S & F modular AC Box sheet metal with socket 3 pin, suitable for 20 Amps flush type universal including 20 Amp C series MCB protected. ( for Geyser )
S &F LED tube light fittings decorative ultra slim linear fixture with extruded alluminium heat sink envioromentel friendly Energy efficient ready to use pack, 1x18/20 Watt , 4 feet,surface mounting type extruded PVC, snap on installers and domestic electronic Driver ,connector block ectwith all assoceries intenal prewired & including connecting up with 2 core fiexible copper conductor cable with sutable size & suitable for and mounting clamps PVC squre box 75x75rnm - 2 nos etc. Make -WIPRO /HAVELLS /JAQUAR /PHILLIPS
S &F LED tube light fittings decorative ultra slim linear fixture with extruded alluminium heat sink envioromentel friendly Energy efficient ready to use pack, 1x10 Watt , 2 feet, surface mounting type extruded PVC, snap on installers and domestic electronic Driver ,connector block etc. with all assoceries intenal prewired & including connecting up with 2 core fiexible copper conductor cable with sutable size & suitable for and mounting clamps PVC squre box 75x75rnm - 2 nos etc. Make WIPRO /HAVELLS /JAQUAR /PHILLIPS
S & F LED Security/Street light fittings 25 Watt wall mounting type extruded metal/aluminium body, and electronic LED driver, eeL with all accessories internal prewired & including connecting up with 2 core flexible cppper conductor cable with suitable size etc. Make· WIPRO /HAVELLS /JAQUAR /PHILLIPS
Fabricate supp!y & fix Gl pipe bracket 25mm dia- 0.9m long & 2 set of clamps made out of 30x5mm MS flat & fixed with anchor bolt suitable for 15w Security light fitling
S&F Fresh air Exhaust fan of size 230/250 mm sweep PVC body complete with and louvers connecting up including provision of three core flexible copper wire of size 23/0.0076 from ceiling rose to exhaust fan. Make - Havells/Crompton Greaves/Bajaj
S&F Energy efficient BEE five star rated ceiling fan, 1200 mm sweep and connecting up including provision of three core flexible copper wire of size 23/0076 from ceiling rose to ceiling fan complete in all respect all as specified and directed. Make: Crompton Greaves/ Bajaj/Orient
S & F MCB TPN 415 Volts, 'C' series, breaking capaciiy 10 KA of rating 63Amps
S & F MCB SP 40 Amps 'C' series, breaking capacity 10 KA of rating
S & F MCB SP 6-32 Amps 'C' series, breaking capacity 10 KA of rating
S & F lSI marked RCBO 40 A, 30 rnA, 230 V DP for AC applications, conforming to IS 12640 (Part-2)- 2016, having front face indication for earth leakage fault, sliding bottom clamp, colour coded on/off indication on dolly, biconnect JP 20 protected lower terminals and sliding shutters complete a!! as specified and directed.
Earthing complete with galvanized steel earth plate electrode 600mm x 600 mm x 6mm buried directly in ground vertically to a depth not less then 2.25 meter below normal ground level with top edge of the plate not less then 1.50 meter below normal ground level connected to galvanized earth wire 4.00 mm dia by means of bolts ,nuts ,check nuts and washers complete up to and including test point made out of 40 x 6mm alum flat including earthing pit , charcoal common salt ,Earthing lead 4.00 mm dia up to 7.5m, 20mm dia medium grade Gl watering pipe ,G.I protection pipe 15 mm dia up to 7,5m long,PPC pit in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate ,PCC pit cover including earth work complete all as shown in electrical plate No-5 of SSR-2014 (part- I). (Int Ele - 02 Nos + Ext E- 02, Ext WS - 04)
INTERNAL WATER SUPPLY
S&F two way bib / angle cock 15mm dia of approved finish complete all as specified and as directed Make: Jaquar Model No. CQT-23041 or equivalent model of Crab Tree / Kohler
S&F shower wall mixer 15mm, 2 in one type, of approved finish complete all as specified and as directed Make: Jaquar Model No. CON-273KNUPR or equivalent model in Crabtree / Kohler
S&F health faucet with flexible pipe (ABS body) with 1.0m long PVC tube and wall hook of approved finish complete all as specified and as directed Make: Jaquar Model No. ALD-CHR-583 or equivalent model of Crab Tree / Kohler
S&F 120mm dia overhead shower with wall mounted shower arm complete all as specified and as directed Make: Jaquar Model No. OHS-1789 & SHA-477 or equivalent model in Crabtree / Kohler
HOT WATER SUPPLY S&F Closed Stationary Storage type water heater geyser, 5 star rating, operating on 230 volt AC, inner tank made out of mild steel, outer body made out of PVC, coil wattage 2000 W, of capacity 50 litre , including earth leakage circuit breaker, nut bolt & washer. Make HAVELLS model no-PURO PLUS or equviva!ant of CROMPTON/ RACOLD/ BAJAJ
EXTERNAL ELECTRIFICATION
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HOPE pipe of 150 mm dia suitable for 0.4 mpa workinq pressure
S&F energy saving and environmental friendly long life LED street light 35 W made up of pressure die cast aluminium housing with high power led as lighting source and lens embedded PC cover having IP65 protection and impact resistance of IK07 with 10 KV Built-in surge Protection device. (Make : Bajaj/Crompton Greaves/Philips)
M & L Hot dip galvanised Iron octagonal pole of height 7 mtrs minimum galavnising of 70 microns, top 70 mm , bottom 130 mm and 3 mm sheet thickness in single section without any weld joints with square plate of minimum dimensions 225x225x12 mm foundation bolts, single arm Gl bracket of 900x1000mm for mounting the light fitting at an angle of 120 degree, backelite sheet with one 6 ASP MCB and 16 mm stud type connectors -04 nos inside the pole at the door opening for cable connections,common templates minimum, 01 for each 15 poles all fixed and bolted on and including suitable, PCC pedestal as per manufacturers recommendations and specifications all as directed (for street/security lights) Mast and pole shaft shall be be as per BSEN 10025,1S 5986, ASTM A572. Make of pole- bajaj / Jindal/Crompton/Shubham
Supply, Installation, test and Commissioning CPRI APPROVED factory fabricated, indoor type, LT panel board ,made out of 3.15 mm thick CRCA Sheet with projected Globe roof for rain water protection Dust and Vermin Proof , Double door with both side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System, including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embedded with 50X50X6mm Mild Steel Angle Iron Frame and 750 mm above the Normal Ground Level complete with internal connection with suitable size of cable, cable lugs and cable glands PCC Foundation in Cement Concrete 1:3:6 (20 mm Graded Stone Aggregate) and Testing after Installation including complete all as specified and comprising of the following :–Make of MCCB/MCB -Schneider/LEGRAND/L&T/HAGER ( main Panel board ) INCOMING:- (a) MCCB with thermal based release 4 pole, 80 AMPS, 50 Hz, 415 Volts, 16 KA -1 No (b) Aluminium TPN Busbar 100 Amps - 1 Set OUTGOINGS:- (a)MCB TPN 415 Volts, 'C' series, breaking capacity 10 KA of rating 63Amps - 02 Nos (01- Bldg main DB, 01 Nos -spare) (b) MCB SPN 240 Volts, 'C' series, breaking capacity 10 KA of rating 16 Amps -3 No(street Light , PH & Aviation) (c) Astronomical, Multifunctional digital time swithces cat no 004767 of legrand or equivalent of L & T cat no- T2 DD T7/MDS/GIC - 1 no (d )Power contactor , 2 pole rating not less than 25 A with 230 coil make L&T/SEIMENS - 1 no. (e) L.T energy meter AC, 3 phase, 4wire 3 x 240V, +/5A, 50Hz, CL 0.5s, category 'C' (DLMS protoclol) with minimum RS 232 or above and optical port, fully state CT/PT operated and AMR compatible Tri-vector energy meters for measurement of different Electrical parameters for balanced/ unbalance load. including CT 100x5 amps-3 nos Make: L&T - Qty-1 no
Supply and fix fix aviation obstruction light LED 10 watt as per bajaj Cat No.BGAV 302 LED equivalent to Philips/ Crompton Greaves
Earthing complete with galvanized steel earth plate electrode 600mm x600 mm x 6mm buried directly in ground vertically to a depth not less than 2.25 m below normal ground level with top edge of the plate not less than 1.50 meter below normal ground level connected to galvanized earth 32 x 6mm Gl strip by means of bolts ,nuts ,check nuts and washers complete up to and including test point made out of 40 x 6mm alum flat including earthing pit , charcoal, common salt, Earthing lead 32x6 up to 7.5m, 20mm dia medium grade Gl watering pipe, PPC pit in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate, PCC pit cover including earth work complete all as shown in electrical plate No-5 of SSR- (part-1) NOTE-: Gl earth strip beyond 7.5 meter shall be measured and paid for separately under relevant item of schedule. (LP - 06 No, Ext Elec- 02, Ex WS- 02)
EXTERNAL WATER SUPPLY
Supply install test and commissiong of centrifugal pump set , electric driven complete with all accessories suitable for pumping water 130 LPM discharge at 30 m head coupled with suitable size of electric motor AC 3 phase ,50Hz including supply and fixing the items, such as , necessary connection from starter !o motor terminal using proper size of copper cable including ,connection of suction pipe from pump to foot valve, delivery pipe connected to the raising mains of the over head rservoir by means of suitable joints painting the suction and delivery pipe with super enamel paint over a coat of primer as per standard code of colour including MS base plate complete complete all as specified and directed.Note : Suction and delivery pipes shall be measured and paid under appropriate items (main water supply pump for building)
Note ·Energy Efficient Motors-Motors shall comply with following a. All permanently wired poly phase motors of 0.375kW or more serving the building and expected to operate more than 1500 hours per year and all permanently wired poly phase motors of 50kW or more serving the building and expected to operate more than 500 hours per year shall have a minimum acceptable nominal full load motor efficiency not less than IS 12615 for energy efficient motors b. Motors of horsepower differing from those listed in the table shall have efficiency greater than that of the next listed kW motor 0.64% c. Motor horse power rating shall not exceed 20% of the calculated maximum load being served,d. Motor nameplate shall list the nominal full- load motor efficiencies and the full load power factor. d. Motor users should insist on proper rewinding practices for any rewound motors. If the proper rewinding practice can not be assured, the damaged motor should be replaced with a new, efficient one rather than suffer the significant efficiency penalty associated with typical rewind practices e. Certificates shall be obtained and kept on record indicating the motor efficiency. Whenever a motor is rewound, Appropriate measures shall be taken so that the core characteristics of the motor is not lost due to thermal and mechanical stress during removal of damaged parts after rewinding a new efficiency test shall be performed and a similar record shall be maintained
Supply and fix Foot Valve conforming to IS 4038, 50 mm dia
Cutting the existing DI/Cl pipe of 50 mm dia and reducing to required length in position for inserting new Tees, branches etc. including Tee, collar
Construction of brick masonry valve chamber of size 900x900x900 mm (internal dia) suitable for 150 mm dia sluice valve with necessary earth work excavation plain cement concrete 1:4:8 using 40 mm graded stone aggregate 75 mm thick in cement mortar 1:6, 15 mm thick plastening 1:6 internally including flooring and externally rep to 15 mm below ground level plain cement concrete 1:4:8 type B1 using 20 mm graded stone aggregate in coping MS sheet cover made out of 3 mm thick MS sheet flat iron frame and bracing with locking arrangement applying two coat of synthetic enamel paint including dismantling removing the existing damane chamber completely removal of debris to a distance not exceeding 50 min distance depositing where as directed by Engr In charge
COOLING APPLIANCES & WATER PURIFIER
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 to 250 V with output voltage stabilized at 230 V with accuracy of± 2.5% and of capacity 2.0KVA Make • V-Guard/MicrotechNintec/AE
Supply and fix Revers Osmosis type water purifier stainlesssteel of output capacity 25 lit per Hr and maximum of 100 lit per day as directed by engr in-charge Make·: Aquaguard D25LPH commercial RO water purifier or equivalent of kent /Eureka forbes
Supply and fix Refrigerator Double door electric driven (single phase), 265 liter, smart inverter type compressor, stabilizer free operation, 230 V,.BEE 3 Star rated. Make- LG, Samsung, Bluestar
TELEPHONE & TV CONDUITS
S &F RJ11 telephone socket 1 module complete all as specified. Make - Legrand/Havells/Anchor
TV socket ,co-axial socket 1 module complete all as specified Make - Legrand/Havells/Anchor
PVC Insulated telephone cable 1P for indoor applications confirming to TEC specification G/WIR06/02, UNARMOURED 0.5 mm ATC. Make - Polycab/Havells/Finolex
Supply and lay coaxial cable for TV Cable drawn through conduit Make - Polycab/Havells/Finolex
Super Construction
Manak landmarks
M/s. R.S. LAWANDE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .