| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.2 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹20.8 L+₹50,929.50 (2.52%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹20.9 L+₹67,580 (3.34%)Rejected-Finance AT ROAD NEAR RENUKA CINEMA P O DIST TINSUKIA ASSAM PIN 786125 | TINSUKIA | TINSUKIA | ASSAM | 786125 | L3 | Rejected-Finance L3 | |
| 4 | L4₹21 L+₹75,020 (3.70%)Rejected-Finance | L4 | Rejected-Finance L4 | |
| 5 | L5₹21.4 L+₹1.1 L (5.64%)Rejected-Finance GANDHI PARK ROAD TINSUKIA ASSAM PIN 786125 | TINSUKIA | ASSAM | 786125 | L5 | Rejected-Finance L5 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
19 Aug 2020, 6:00 pmClosed
GE DINJAN
GE DINJAN, PANITOLA (PO), DIBRUGARH (DIST), ASSAM
PERIODICAL SERVICES INCLUDING TREATMENT TO EXPOSED REINFORCEMENT OF BLDGS AND COMPOUND WALL AT DINJAN MIL STN
2020_MES_360989_1
C/8210/E8
Open Tender
Civil Works
Item Rate
180 days
DINJAN MIL STN
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE DINJAN
₹40,000
Yes
11 Sept 2020
15 Jul 2020
21 Aug 2020
15 Jul 2020
19 Aug 2020
30 Jul 2020
Amount
Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water complete all as specified and as directed.
M&L for rendering 5 mm thick in cement mortor 1:3 on concrete surfaces as in ceilings (sunshed, chajja etc) and finishing surfaces even and smooth without using extra cement complete all as specified and as directed.
M&L for rendering 10 mm thick on fair faces of brick work or concrete surfacesas in walls in cement mortar 1:6 and finished the surfaces even and smooth without using extra cement complete all as specified and as directed.
M&L for rendering 15 mm thick in two layers (i.e. 10 + 5mm) on fair faces of brick work or concrete surfaces as in walls in cement mortar (1:4) mixed with integral water proofing compound by weight of cement as per manufacturer's instructions in top layer and finished the surface even and smooth without using extra cement complete all as specified and as directed. Note : WPC shall be measured and paid separately against respective item.
Supply only integral water proof compound for external plaster complete all as specified and as directed. Make : Dr Fixit of Pedilite or equivalent as approved by GE.
M&L for preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and as directed.
M&L for preparing newly plastered surfaces of walls, etc and applying three coats of white wash complete all as specified and as directed.
M&L for Preparation of newly plastered surfaces of external walls and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and as directed.
M&L for preparing old decorated surfaces of walls and applying one coat of white wash complete all as specified and as directed.
M&L for preparing old decorated surfaces of ceiling and applying one coat of white wash complete all as specified and as directed.
M&L for preparation of old decorated plastered surfaces of walls and applying one coat of colour wash complete all as specified and as directed.
M&L for preparation old decorated plastered or unplastered surfaces of wall cornices etc by brooming down or steel wire brushing, scraping down,the surfaces covered by smoke soot, growth of moulds and moos, efflorescent, having oil and gresase spots and applying one coat of cement base paint (white or tinted) complete all as specified and as directed.
M&L for preparing old decorated surfaces of walls by complete removal of existing treatment and applying two coats of cement base paint over a coat of alkali resistant priming paint complete all as specified and as directed.
M&L for preparing old decorated surfaces of walls and applying one coat of distemper oil emulsion complete all as specified and as directed.
M&L for preparing old decorated surfaces of walls by by rubbing down, stopping of distempered and painted surfaces, washing and applying two coats of distemper-oil-emulsion over a coat of chalk whiting primer complete all as specified and as directed.
M&L for Preparation of old painted wood and wood based surfaces of any description, over 10 cm in width or girth, not otherwise described and applying one coat of synthetic enamel paint complete all as specified and as directed.
M&L for Preparation of old painted steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying one coat of synthetic enamel paint complete all as specified and as directed.
M&L for preparing old plastered surfaces of walls, etc by complete removal of existing treatment and applying two coat of distemper oil emulsion over a coat of primer and providing one coat of wall care putty (min 1.0mm thick) complete all as specified and as directed.
M&L for preparing old plastered surfaces of ceilling, etc by complete removal of existing treatment and applying two coat of distemper oil emulsion over a coat of primer and providing one coat of wall care putty (min 1.0mm thick ) complete all as specified and as directed.
M&L for preparation existing painted surfaces of wall, chajja, facia etc and applying one coat of water based acrylic weather proof exterior emulsion (Apex ultima superior quality) paint as per manufacturer's instruction complete all as specified and as directed.
M&L for preparation old decorated external surfaces of wall, chajja, facia etc by complete removing old paints by hand scrubber without disturbing the plastered surfaces broomed to remove all dust, diret and all loose scales of old paints and other foregin matter and applying two coats of water based acrylic weather proof exterior emulsion (Apex ultima superior quality) paint over a coat of primer as per manufacturer's instruction complete all as specified and as directed.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and as directed.
S&F for 3mm thick, sheet glass, ordinary quality and glazing with oil putty in square not exceeding 0.5 Sqm in each pane complete all as specified and as directed.
S&F for 5mm thick, sheet glass, ordinary quality and glazing with oil putty in square exceeding 0.5 Sqm in each pane complete all as specified and as directed.
Identifying and marking carefully the damaged reinforced concrete by tapping with light hammer and chipping of unsound weak concrete and plaster material from slabs/beams/columns etc. with power/hand driven chisel as directed by the Engr-in-charge upto 25mm average depth including saw cutting of all edges making square shoulders of cavities complete all as specified and as directed. (All loose unsound and cracked concrete retrieved shall be removed to a distance not exceeding 50m and deposited in low laying area as directed by the Engr-in-Charge) Note : Thickness shall be measured excluding plaster thick)
M&L for applying two coats of epoxy based preservative, protecting & bonding coat of zinc rich system (Nitcozinc ® primer of Fosroc and equivalent of SIKA/Dr Fixit Pidilite/krishna Conchem) as approved by the Engineer-in-Charge for old reinforcement any dia complete all as specified and as directed. Note : Epoxy based preservative, protecting and bonding coat of zinc rich system shall be paid for separately.
Supply only epoxy based passivating, protecting and bonding coat of zinc rich system (Nitozinc (R) primer of Fosroc and equivalent of SIKA/Dr Fixit Pidlite/Base) as approved by the Engr-in-Charge. Note : Evaluation of quantity and payment shall be made for total weight of resin and hardner as per manufactured specified proportion).
M&L for TMT bars 8/10mm dia and over cut to length bent to shape and welded to the existing reinforcement as additional bars to location (where original cross section of area of existing bars has reduced by more 20%) welding has to be done with minimum 20cm over lap for new and old reinforcement of any height complete all as specified and as directed.
Supply only approved acrylic polymer SBR latex FOSROC/BASF/DR FIXIT/SIKA for bonding coat complete all as specified and as directed. Note : Rate shall be in terms of solid contents of polymer.
M&L for mixing and applying SBR latex modified cement mortor 25mm thick in cement sand mortar in proportions of 1:3 (1 cement and 2 graded 12.5mm size aggregate) with polymer admixed in proportions as per manufacturer instruction, including trowelling with wooden tools on prepared concrete surfaces of parent material complete all as specified and as directed. Note : Acrylic polymer SBR latex shall be paid for separately.
M/S HAZARIKA CONSTRUCTION
STANDARD ELECTRIC WINDERS
FREEZCON
Bimal Trading Company
M/S AUTOMOTIVE WORLD
Kaushik Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .