Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.7 LAccepted-AOC FLAT NO 7 MHAMBRE BLDG DR FRANCISCO LUIS GOMES ROAD VASCO DA GAMA GOA 403 802 | SOUTH GOA | GOA | 403802 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹25.8 L+₹85,055 (3.40%)Rejected-Finance SALGAONKAR HOUSE DRIVERS HILL VASCO DA GAMA GOA 403802 | SOUTH GOA | GOA | 403802 | L2 | Rejected-Finance Higher bidder | |
| 3 | L3₹26.3 L+₹1.3 L (5.33%)Rejected-Finance | L3 | Rejected-Finance Higher bidder | |
| 4 | L4₹27.0 L+₹2.0 L (8.16%)Rejected-Finance H NO 767 NEAR OLD POST OFFICE NEW VADDEM VASCO DA GAMA GOA 403 802 | SOUTH GOA | GOA | 403802 | L4 | Rejected-Finance Higher bidder | |
| 5 | L5₹28.4 L+₹3.4 L (13.8%)Rejected-Finance C2 PAIXOMONTIRO APTS BEHIND NSD ALTO DABOLIM VASCO DA GAMA GOA 403 801 | SOUTH GOA | GOA | 403801 | L5 | Rejected-Finance Higher bidder |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
30 Oct 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SH A K SINGH SE CWE NAVY VASCO
CWE NAVY VASCO VASCO DA GAMA GOA 403802
REPAIR AND MAINTENANCE TO DISTRESS CONCRETE AND SUNKEN FLOOR UNDER AGE B R II AREA OF GE GOMANTAK VASCO
2021_MES_477631_1
85487/E8
Open Tender
Civil Works
Item Rate
180 days
CWE NAVY VASCO
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
Yes
GE GOMANTAK VASCO
₹60,000
Yes
15 Dec 2021
24 Sept 2021
3 Nov 2021
24 Sept 2021
30 Oct 2021
16 Oct 2021
60 days
Amount
Dismantling of Plain or corrugated steel sheeting, of any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
S & F pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering cladding to wall fixed with self tapping screws complete all as specified and directed.
S & F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
Dismantling wrought iron of mild steel work of any description not otherwise provided for, complete all as specified and directed.
S&F Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates GDE Fe 410-0 W (Gde E-250) quality A complete all as specified and as directed
S & F Stairs (framed) including stringers, treads, landing, balusters, hand rails etc. in- cludding cleats, brackets, etc. complete all as specified and directed.
M&L for two coats of synthetic enamel paint over a coat of red oxide primer on new steel surfaces including preparation of surfaces exc over 10 cement mortar width or girth complete all as specified and directed.
Taking down cement plaster on brick work or stone walls including racking out joints ,hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for rendering in cement mortar 1:6 10mm thickness on brick/cement/stone surfaces and finishes the surface even and smooth without using extra cement complete all as specified and directed.
M&L for rendering in cement mortar 1:4 (10+5)=15mm thickness on brick/cement/stone surfaces and finishes the surface even and smooth without using extra cement including mixing with liquid WPC on top 5mm thick only complete all as specified and directed. Note :- Water proofing compound shall be paid separately
M&L for rendering in cement mortar 1:4 ,5mm thickness on ceiling concrete surfaces and finishes the surface even and smooth without using extra cement complete all as specified and directed.
Supply only Liquid water proofing compound (as per approved make , 200ml per bag of cement) complete all as specified and directed.
M&L for two coats of acrylic emulsion exterior paint (anti fungal painting as per approved make) over a coat of acrylic emulsion primer on new surfaces including preparation of surface of any description complete all as specified and directed.
M&L for one coat of acrylic emulsion exterior paint (anti fungal painting of approved make) on old surfaces including preparation of surface of any description complete all as specified and directed.
M&L for providing two coats of oil-bound distemper over a coat of alkali-resistant primer on newly plastered wall surfaces including necessary preparation to surfaces complete all as specified and as directed.
M&L for providing two coats of oil-bound distemper over a coat of alkali-resistant primer on new plastered ceiling surfaces including necessary preparation to surfaces complete all as specified and as directed.
M&L for providing one coat of oil-bound distemper on old plastered wall surfaces including necessary preparation to surfaces complete all as specified and as directed.
M&L for providing one coat of oil-bound distemper on old plastered ceiling surfaces including necessary preparation to surfaces complete all as specified and as directed
Dismantling of loose portion of concrete from ceiling and S&F of wire mesh of weight 2.5kg/sqm and apply 25mm average thickness in cement mortar(1:4) mixed with liquid integral WPC (complast 'X' recommended by the manufacturer with guniting machine at a pressure not less than 5kg/sqm finally rendering 10mm thick plaster in cement mortar (1:4) using WPC (Complast 'X' 421 from approved make or equivalent as approved by GE ) in the proportion recommended by the manufacturer complete all as specified and directed.
M&L for two coats of water proofing coating system ( of approved make) , over a coat of primer including preparation of New/ old plastered surfaces all as specified & directed. (The treatment has to be carried out through authorised applicators of the respective companies) complete all as specified and directed.
Removing loose concrete/plaster upto sound stratum of ceiling chajjas, columns and beams and cleaned the surface with water using water jet etc complete all as specified and as directed.
M&L for applying one coat of chemicals as approved to old rusted reinforcement after necessary preparation of surfaces by brush application as per metric 100 complete all as specified and as directed.
M&L for priming the old/new steel reinforcement bars with one coat of Epoxy Zinc primer or equivalent as approved, by brush application complete all as specified and as directed.
M&L for previously prepared steel/concrete surfaces and apply concrete penetrating corrosion inhibitor, after few minutes wipe the concrete/steel surface with moist cloth to remove residual materials from the surface and follow up the application complete all as specified and as directed.
M&L for providing and applying approved bonding agent prior to application of any type of mortar plaster to ensure bond between old concrete and new concrete all as specified and as directed.
M & L for applying one layer of spray SL concrete 20 mm thick comprises composition 1:2:1 plain cement concrete(i.e) one part of cement, two part of course aggregate & one part of 10 mm & down size trap stone aggregate mixed with spray SL 2 to 2.5 % by weight on concrete surfaces complete all as specified and as directed.
M&L for cutting out cracks to 'V'section of 5 to 10 mm as per site requirement in existing roof walls, by using machine cleaning the groove to remove all loose laitance & wash them with water and applying crack filler with the aid of a putty blade compete all as specified and as directed.
S&F TMT (CRS) bars of 10 mm dia and above, cut to length & bent to shape as required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips welding to existing rod etc. complete all as specified and directed.
S&F TMT (CRS) bars of 6mm to 8 mm dia cut to length & bent to shape as required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips welding to existing rod etc complete all as specified and directed.
M&L for providing 10mm thick cement plaster over roof slab (over the area of dismantled roof treatment ) in cement mortar 1:4 mixed with Water proofing compound @ 200 ml per bag of cement finished even and smooth without using extra cement (quoted rate shall exclusive of SBR latex) complete all as specified and directed. Note :- Water proofing compound shall be measured and paid separately.
M&L for removing of APP treatment from roof surface, cleaning of roof tops including removing the existing treatment by brooming down with steel wire brushing scrapping down with steel scrapper and roughening the existing surfaces to receive plaster Supply & Laying water proofing treatment using 4mm thick APP modified membrane consisting five layer membrane with features as specified, weighing not less than 4.5 kg per Sqm laid over a coat of cold applied bituminous primer @ 0.20 Kg per sqm by torching the membrane including sealing the overlap while torching with 100mm on length side and 100mm wide side as per manufacturer instructions including joints and changes in direction the curved with cement mortar 1:3 mixed with Water proofing compound @ 200 ml /bag of cement cured well before laying of membrane all as per manufacturer instructions and to the satisfaction of Engineer -in-charge including two coats of bituminous aluminum paint complete all as specified and directed. Notes:- (i) Irrespective of lap the net covered area shall only be measured for payment. (ii) The quoted rate is deemed to be inclusive of primer APP membrane & SBR Latex
Demolition of damaged masonry (brick/stone/brick masonry wall built in cement mortar as in wall/ manholes etc. complete all as specified and directed.
M&L for precast cement concrete block masonry with solid blocks in cement concrete 1:3:6, type C5 exceeding 10 cm in width and set in cement mortar 1:6 complete all as specified and directed.
M&L for rendering 15 mm thick on brick or concrete surfaces in cement mortar 1:4 finished even and fair without using extra cement complete all as specified and directed.
Dismantling water tanks exc 250 and not exc 500 ltr. capacity and removing to store complete all as specified and directed.
Dismantling water tanks exc 500 and not exc 1000 ltr. capacity and removing to store complete all as specified and directed.
S&F Rotational moulded polyethylene water storage tanks of 500 lit (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and directed.
S&F Rotational moulded polyethylene water storage tanks of 1000 lit (cylindrical vertical with closed top) hoisted and fixed in position all complete all as specified and directed.
Disconnecting 500 Ltrs existing tanks setting aside (or lowering if required) for repairs, cleaning scales and dirt, algae fungus etc and hoisting if required reconnectiong complete all as specified and as directed.
Disconnecting 1000 Ltrs existing tanks setting aside (or lowering if required) for repairs, cleaning scales and dirt, algae fungus etc and hoisting if required reconnectiong complete all as specified and directed.
S&F 25 mm dia. gate valve gun metal. Complete all as specified and directed.
Taking up or down GI tubing of 25 mm dia including cleaning for re-fixing or removal from site. complete all as specified and directed.
Refixing 25 mm dia. old steel tubing and connections in new or old position (Walls, ceiling, floors, etc.) complete all as specified and directed.
Taking up or down GI tubing 20 mm dia including cleaning for re-fixing or removal from site. complete all as specified and directed.
Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors, including all fittings complete all as specified and directed
S&F 20 mm dia. gate valve gun metal. Complete all as specified and directed.
Demolition of cement concrete in ground floor and pavings exc 15 cement mortar thickness above ground level complete all as specified and as directed.
M&L for lean concrete 1:5:10 with 40 mm grade stone aggregate in cement mortar 1:2 as in sunken floor including spreading, leveling and well ramming complete all as specified and as directed.
M &L for loose filling with broken bricks of gauge 40mm to 80mm in sunken floor complete all as specified and as directed.
Dismantling of floor hearth wall tilling including cement mortar bedding (but not backing) removing serviceable to store and rubbish off the premises. complete all as specified and directed.
M&L for screed bed or bedding layer of mortar 15 mm thick in 1:4 cement mortar for laying of floor tiles. complete all as specified and directed.
M&L for coloured non skid ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tiles exc. 0.11 Sqm but not exc 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed with white or coloured cement to match. complete all as specified and directed.
M & L rendering 10 mm thick on fair face of brick work or concrete surface in cement mortar 1:4 on vertical surface for wall tiles. complete all as specified and directed.
S&F Glazed ceramic coloured tiles in vertical surface 250x 375x 7 mm/ 450x350x7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match Coloured tiles complete all as specified and directed.
S&F 32 mm dia low density polyethylene pipes (LDPE) of pressure rating 6 Kg/cement mortar2 laid in floor or wall complete all as specified and directed.
S&F 100/125 mm dia cast iron Nahani trap including grating jointed to waste pipe fixed in cement concrete, type B1 (1:2:4). Complete all as specified and directed.
Dismantling of cast iron drain pipe 100mm dia jointed in cement mortar and taking out of trenches/wall/floor etc incl fitting in foul condition. Complete all as specified and directed.
S&F PVC (SWR) pipes 110 mm single socketed in any length with rubber ring joints fixed to walls in foul condition complete all as specified and directed.
S&F PVC (SWR) pipes 75 mm single socketed in any length with rubber ring joints fixed to walls in foul condition complete all as specified and directed.
S&F 75 mm dia PVC SWR bend with access doors. Complete all as specified and directed.
S&F 110 mm dia PVC SWR bend with access doors. Complete all as specified and directed.
S&F PVC SWR 75 mm junction single (single T) equal or unequal with access doors complete as specified and directed
S&F PVC SWR 110 mm junction single (single T) equal or unequal with access doors complete as specified and directed.
S&F in repair Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern & flush pipe) complete all as specified and directed.
S&F in repair plastic water closet seat cover closed pattern with flat bottom any colour and mild steel plastic hinges. Complete all as specified and directed.
S&F PVC in repair valveless, symphonic action type, flushing cistern, 10 liters, low level, white, with inlet, ball valve, float and handle including brackets and connections to pipes and fixing of chain and pull, or level, if any fixed in repairs. Complete all as specified and directed.
S&F in repair Vitreous China wash basin, white, flat back, size 550x400mm but including brackets and 15mm dia CP fancy type pillar cock. complete all as specified and directed.
S&F in repair PVC connections 15 mm size with PTMT nuts of length 600m fixed in repair. complete all as specified and directed.
S&F in repair WHB mixer, for mixing hot and cold water fancy type cast copper alloy , with capstan heads, chromium plated , screwed down for 15 mm bore pipe,high pressure with long screwed shanks and fly-nuts , screwed for iron pipe ISI Marked of approved make complete all as specified and directed.
S&F in repair CP wall mixer, for mixing hot and cold water fancy type cast copper alloy , with capstan heads, chromium plated , screwed down for 15 mm bore pipe,high pressure with long screwed shanks and fly-nuts , screwed for iron pipe ISI Marked of approved make complete all as specified and directed.
S&F in repair 15mm Chromium plated , fancy type, Stop valves / angle valve screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed in repair complete all as specified and directed.
S&F in repair 15mm Bib taps, long nose fancy type chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule of approved make ,complete all as specified and directed.
S&F in repair brass chromium plated shower rose with shower arms with swivel joints including fixing to steel pipe or union, complete all as specified and directed.
S&F in repairs Vitreous china, white, Squatting pan ,'Orrisa' pattern size 580x440mm with integral footrests water closet) , front or back inlet complete , connection to drain pipe and to flushing pipe , anti simphonage pipe etc complete including making good to floor to match with the existing all as specified complete all as specified and directed.
Demolition of reinforced cement Concrete of any description and in any position complete all as specified and directed.
Demolition of cement concrete in ground floor and pavings n.exc 15 cement mortar thickness below/above ground level complete all as specified and as directed.
M&L for 75 mm thick PCC 1:3:6 type B2 using 40 mm graded stone aggregate complete all as specified and directed.
M&L for 25mm Cement concrete type B-0, 1:2:4 using 12mm graded stone aggregate complete all as specified and directed
Dismantling of ceiling boards of any thickness, including cover fillets complete all as specified and directed.
S&F hangers 6 mm dia G.I (upto 1200 mm lenght ) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I flat 40 X 3 mm size 60 mm long complete all as specified and as directed.
S&F 605x605mm anodised aluminium snap grid frame work for false ceiling using standard anodised aluminium T section of size 45mm x 25mm x 1.5mm thick and 45 x 25 x 1.5mm thick angle section, including necessary 'J' bolts all as specified and as directed.
S&F PVC False ceiling consisting of 600mmx600mm,10mm thick plain colour PVC sheet complete all as specified and as directed.
M&L for Three Coat of White Wash on newly plastered surfaces of wall including preparation of surface complete all as specified and as directed.
Tara Construction
M/S. M M S ENTERPRISES
M/S DUBAL CONSTRUCTION
M/S P S BABU
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .