| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.4 LAccepted-AOC 131 SHINGANAPUR ROAD KOLKI KOLKI SATARA MAHARASHTRA 415523 | SATARA | MAHARASHTRA | 415523 | L1 | Accepted-AOC L1 | |
| 2 | L₹33.2 LRejected-Finance 1 128 A SECOND FLOOR MOHAMMADPUR NEAR BHIKAJCAMA PLACE NEW DELHI 110066 | NEW DELHI | NEW DELHI | DELHI | 110066 | L | Rejected-Finance Other than L1 | |
| 3 | Rejected-Technical | - | Rejected-Technical Not approved for opening of Cover 2 due to being sister concern firm to M/s Vishal Traders |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
11 Mar 2023, 6:00 pmClosed
CWE NO 2 DELHI CANTT
HQ CWE NO 2 DELHI CANTT-10
SPECIAL REPAIR TO BER GOODS LIFT AT PATIENTS COOK HOUSE AT BASE HOSPITAL DELHI CANTT AND PROVN OF REVERSE OSMOSIS SYSTEM OF CAPACITY 600 LPH FOR SINGLE LIVING ACCN OF JCOs/ORs AT AFTC DELHI CANTT UNDER GE E/M BASE HOSPITAL DELHI CANTT-10
2023_MES_580373_1
CWE/BH-52/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
BASE HOSPITAL DELHI CANTT
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE E/M BASE HOSPITAL DELHI CANTT
₹70,000
Yes
24 Mar 2023
11 Feb 2023
13 Mar 2023
11 Feb 2023
11 Mar 2023
27 Feb 2023
Amount
Excavation in trenches not exceeding 1.5 M wide and not exceeding 1.5 M in depth for foundation etc or for shafts, wells, cess pits, manholes, pier holes etc not exceeding 10 Sqm on plan and not exceeding 1.5 M in depth and getting out in soft/loose soil.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil complete all as specified and as specified.
Removing of excavated materials to a distance not exceeding 50 M and deposing where directed at a level not exceeding 1.5 M above the starting point complete all as specifiedand as directed.
M&L for cement concrete 1:4:8 type D2 using 40 mm graded stone aggregate as in foundations filling, sub base and mass concrete filling, etc complete all as specified and as directed.
Demolition of brick work built in cement mortar including all quoins, pillars etc, complete all as specified and as directed.
M&L for brick work with sub class ‘B’ bricks straight or curved on plan exceeding 6 M mean radius, using old sise bricks built in cement mortar 1:6 complete all as specified and as directed.
Taking down cement plaster on brick or stone walls etc. including raking out of joints, hacking for key, scrubbing down with water etc. of any description complete all as specified and as directed.
M&L for plastering 15 mm thick in cement mortar 1:4 on fair faces of brick or concrete surfaces, finished the surface even and fair with using WPC @ 2% by weight of cement (Note- WPC shall be measured and paid separately)
M&L for 15mm thick cement plaster on other than fair faces of brick work or concrete surfaces in cement mortar 1:6 finished even andfair complete all as specified and directed.
M&L for 10 mm thick cement plaster on Ceiling surfaces in cement mortar 1:3 finished even and fair complete all as specified and directed.
M&L for Reinforced cement concrete as in Beams, cantilevers, bressummers, lintels over 1.5m span in cement concrete (1:1 1/2 :3) using 20 mm graded crushed stone aggregate complete all as specified and directed.
M&L for Reinforced cement concrete as in landing slabs in cement concrete (1:1 1/2 :3) using 20 mm graded crushed stone aggregate incl necessary form work, etc complete all as specified and directed.
M&L for mild steel 10 mm dia tmt bar and over as in reinforcement cut to length, bent in shape required including cranking, bending, spirally hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips etc.
All as per item No 13.00 here-in-before but mild steel tmt bar 6mm to 8 mm dia.
Use & waste Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, Chhajja, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc.
Use & waste Formwork to soffits of suspended slabs such as roof slabs,flat, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) fair finished complete.
M&L for 75 mm thick PCC 1:3:6 type C-1 using 20 mm graded stone aggregate as in plinth protection/Hard Standing, finished the surface even and smooth without using extra cement complete all as specified and directed
M & L for preparation of new plaster surfaces and applying two coat distemper oil emulsion over 3 mm thick wall care putty on walls as levelling course complete all as specified and directed.
M&L for 18 to 20 mm thick of approved shade granite stone (Zed Black) (Superior quality) slab (table rubbed and polished as in floors, jambs, steps, cooking platform, shelves etc and the like, over creed bed incl pointed in white cement (1:2) using marble dust iwth admixture of pigment to match with shade of granite complete all as specified and directed.
M & L for preparation of new plaster surfaces applying two coats of weather proof paint epex altima over 3 mm wall care putty complete all as specified and directed.
M & L for preparation of new ceiling plaster surfaces applying two coat coat of oil bound distemper complete all as specified and directed.
M&L for roof treatment with polymeric membrance (APP based) with non woven polyster mat as reinforcement with following:- (a) M&L for cleaning the new plastered surface and providing & laying a coat of cold applied bitumen 85/25 based primer on entire surface @ 0.30 Ltr/Sqm on dry and clean surface. (b) M&L for providing & laying APP based polymeric membrane of 3 mm thickness of weight not less than 3.0 Kg/Sqm with non woven polyster fibre as reinforcement on primed surface by torch application with 15 cm end over laps & 10 cm side over laps etc as per manufacturers instruction. (c) M&L for finishing of top surface by applying two coats of aluminium paint complete all as specified and directed.
Supply only water proofing compound ISI marked.
Dismantling, Removing and deposit in MES Yard existing electrically operated Dump Waiter Lift(G+1) installed at A Block cook House location of capacity 500 Kgs complete including control panel motors and gear boxes power control and trolly wiring, limit switches, levelling devices, ropes, sheaves, counter weights, with guards, buffers, joists, beams, and call indicators car as a whole including all guide rails landing doors etc including any other accessories all as specified and directed.
Supply and installation testing commissioning of Good lift 1000 Kg 0.50Mtr/Sec two stops, 2 Openings -(Front side opening at Ground Floor & Reverse Side Opening at First Floor),Floor designations G,1,Machine type & Location – Geared machine located on the above of shaft/ at Machine Room,Control Down Collective Control Drive -ACVVVF (11 KW) as per OEM Recommended Power supply -415 volts, 3 phase, 50Hz, AC Hoist way dimensions- 1700mm wide x 1800mm deep Car travel 4200mm Overhead 4500mm Pit depth 1500mm Car dimensions 1050 mm wide x 1600mm deep x 2100mm high Door opening 1000mm wide x 2000mm high Car door Manual Mild Steel collapsible opening door in Black finish Landing door Manual Mild Steel collapsible opening door in Black finish on 2 floors Car design Silver Grace (in Stainless Steel Silver Sky finish) Car flooring 5mm Aluminium Chequered flooring Handrail Round handrail in Stainless steel finish provided on Left & right wall of car Landing operating panel Individual landing operating panel for each elevator , Motor Size :- 7.50 KW, steel wire Rope shall Día 10 mm x 5 Nos (3mm)
Features Included-1. ACVVVF closed loop drive 2. Alarm button in car operating panel with battery back-up 3. Emergency light 4. Full load by-pass 5. Intercom 6. Motor overheat protection 7. Automatic rescue device in case of power failure 8. Red dot matrix scrolling display in car operating panel 9. Red dot matrix scrolling display in landing operating panel on All Floors 10. Fireman control, Note :- (i) Name of manufacturer of lift along with drawing shall be proposed by manufacturer as per design criteria as mentioned above and approved by Accepting Officer. (ii) Quated rate is deemed to be inclusive for testing of each lift by licensed lift inspector of Govt of Delhi once in contract period for the worthiness certificate in respect of safety. A copy of certificate shall be be displayed in all lift cabins as directed.
M&L for Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed.
M&L for GI tubing light grade 80mm bore including all fittings for earthing lead protection and cable protection complete all as specified and directed.
M & L earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit pipe or fixed to poles or any indicated situation for loop earthing etc as required GI strip 25mm x 3mm size complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of
(a) 70 Sqmm 3.5 Core
(b) 50 Sqmm 3.5 Core
(c) 25 Sq mm 4 Core
S & F distribution board (DB), double door type made out of sheet metal enclosure (CRCA sheet) dust and vermin proof MCCB DB, TPN 4 way with 250 Amps rated copper busbar, 415 Volts, earth bar IP 43 protection, flush to wall complete all as specified and directed.
S & F MCCB TPN, 63 Amps capacity , 25 KA, DRX thermal magnectic, 420 Volts, complete all as specified and directed.
Supply, installation, testing and commissioning factory made and tested LT switch gear Panel (Minimum size 1200 x 1500 x 450 mm), outdoor type, platform mounted, totally enclosed, dust and vermin proof, made out of 50 x 50 x 6 mm thick MS angle iron frame, 0.50 Mtr height Legs and CRCA sheet of not less than 3.15 mm thick, as per IS 5039, cubical type, front and rear side openable, provision of air vent and provision of cable alley, with 630 Amps Aluminium rated bus bar for phases and 400 Amps rated bus bar for neutral, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size but not less than 1.5 Sqmm complete. The panel shall be suitable for 415 Volts, 50 Hz, 3 Phase, 4 wire system and bus bars fixed on porcelain or PVC insulators, thimbles, glands of brass. All sheet metal works including frame shall be painted with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of Siemens grey RAL- 7035 shade, including necessary PCC, brick Masonry & plastering work for grouting of panel including disconnecting and removing the existing old unserviceable LT panel complete all as specified and as directed. The panel shall be suitable for accommodating and inclusive of following accessories (As described in Srl item Nos 31.01 here in after) complete all as specified and as directed :-
Cross arms, bracings, supports,clamps and back plates fabricated from structural steel sections including nuts, bolts, washers,welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and as directed.
Supply installation testing and commissioning of Reverse Osmosis system of capacity 600 LPH with pre and post treatment scheme comprising with following specifications complete all as specified and directed pl:- (Make : ION Exchange Ltd.) (i) RAW WATER PUMP: Flow Rate : 1200 Ltrs./Hr Head : 25 – 30 Mtr MOC : CI Make : Kirloskar (ii) MULTIGRADE FILTER MODEL : NGMF-20 Max. flow Rate : 2.0 m3 /hr Inlet/Outlet connection : 50/50 mm Max. working pressure : 3.5 kg/cm2g Width : 450 mm Height : 2000 mm Depth : 800 mm Shipping weight : 310 kg Working Weight : 38 mm (iii) ACTIVATED CARBON FILTER MODEL : NGMA-20 Max. flow Rate : 2.0 m3 /hr Inlet/Outlet connection : 50/50 mm Max. working pressure : 3.5 kg/cm2g Width : 450 mm Height : 2000 mm Depth : 800 mm Shipping weight : 310 kg Working Weight : 38 mm (iv) CHEMICAL DOSING SYSTEM : MODEL CDS-1 (Antiscailent Dosing Pump) Chemical Tank Volume : 100 ltr Max. Frequency Strokes per Min. : 100 M.O.C : HDPE
Pump Discharge Capacity:Flow Rate : l/h 2.88Nos. : OneMOC : PVCSpecification:-• Chemical Tank capacity – 100 ltrs with lid• Electronic diaphragm (made of high quality fabric reinforced EPDM) type metering pump.• Foot valve with strainer on pump suction assembly (v) REVERSE OSMOSIS SYSTEM (MAKE – ION EXCHANGE I LTD.) . . Permeate flow rate LPH : 600 Recovery % : 40 - 50 Membrane type : Hydranautics Membrane dia Inch : 4 No. Of Membrane : 03 High pressure pump Type : Multistage centrifugal Make / Model : Grundfos CRN Series / Equivalent Capacity : 3m3/hr Cartridge filter Micron rating : 10 Housing type : PP Make : Parker / equivalent
(vi) CHEMICAL DOSING SYSTEM : MODEL CDS-1 (PH Correction) : . Pump Discharge Capacity Flow Rate : l/h 2.88 Nos. : One MOC : PVC Specification:- • Chemical Tank capacity – 100 ltrs with lid • Electronic diaphragm (made of high quality fabric reinforced EPDM) type metering pump • Foot valve with strainer on pump suction assembly (vii) PVC interconnecting pipe works within battery limits for 2 Mtr
S & F rotational moulded polyethylene water storage tank of capacity 5000 ltr (cylindrical, vertical, with closed top) hoisted and fixed in position, including complete connection of inlet and outlet pipe, tank nipple, float valve fixing of GI pipe (over flow) etc as per site requirement complete all as specified and directed.
Supply , laying and testing of 25 mm bore GI water tubing, medium grade, with all fittings, with screwed and socketed joints and fixed complete to wall, ceiling or laid in floor etc. and making good the disturbed surface complete all as specified and directed.
Supply and fixing gun metal gate valve of size 25 mm bore dia, painted finish, with forged brass spindle and iron wheel head, screwed both ends complete all as specified and directed.
Supply and fixing pre painted galavaniume Aluminium zinc coating GI based corrugated steel sheet 0.5 mm thick of any colour having tensile strength of 550 Mpa as in roof convering/ cladding to wall, fixed with self tapping screws complete all as specified and directed please.
Supply and fixing steel tubular trusses, purlins, rafter vertical post, MS angles, plain MS plate including cutting/ welding & drilling and similar works includng special shaped washer etc complete using ERW or induction butt welded tubes including cleatd, plate, hold fast and including conforming to IS 1161-1998 Gde, ST-240 complete and two coats of synthetic enamel paint of silver colour on steel/ Iron surface over a coat of red oxide primer including preparation of surface complete all as specified and directed please.
M & L for PCC 1:3:6 type C2 using 40 mm graded stone aggregate as in foundation mass concreate and similar work etc complete all as specified and directed.
M & L for PCC 1:2:4 type B2 using 20 mm graded stone aggregate as in surface , channel drains mass concreate and similar work etc complete all as specified and directed.
M & L for coated hot rolled fiberglass roof sheet of thickness at least 5 mm arround the RO plant fixed with MS angle tanks and a door/ gate made by fiber sheet , door to be fixed by 03 Nos 100 mm long hinges and one sliding door bolt of 300 mm long for locking arrangement complete all as specified and directed please.
S & F distribution board (DB), double door (CRCA sheet) dust and vermin proof SPN 8 way with 200 Amps rated copper busbar, neutral bar, earth bar, IP 43 protection, single pole and neutral 240 Volts, flush to wall complete all as specified and directed.
S & F MCB TPN, C curve, 415 Volts, 40-100 Amps complete all as specified and directed.
M&L for sub main wiring with 4 runs of 10.0 sqmm single core, PVC insulated & unsheathed (FR) cable 1100 Volts grade with multi stranded, copper conductor drawn through concealed conduit including PVC rigid conduit medium grade as per ISS and two run of 6.0 sqmm size PVC insulated copper conductor complete all as specified and directed.(Note. Two run of cable and earth conductor shall be measured as one length).
M/s Dhapola Elevator and Engineering
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .