| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹34.9 LAccepted-AOC VILL ADAMPUR PO PATORA P S K NAGAR DIST PURNEA PIN 854304 BIHAR | PURNEA | PURNEA | BIHAR | 854304 | ₹34.9 L | 1 | Accepted-AOC Being L1 bidder |
| 2 | 2₹38.3 L+₹3.4 L (9.82%)Rejected-Finance E 140 2010 BKP VILL AMTALLA PO DUMARCHIR DIST PAKUR PIN 814111 JHARKHAND | PAKUR | PAKUR | JHARKHAND | 814111 | ₹38.3 L+₹3.4 L (9.82%) | 2 | Rejected-Finance Not Being L1 bidder |
| 3 | 3₹40.1 L+₹5.2 L (14.8%)Rejected-Finance OPPOSITE J K BANK BAROO NH1 HAIDERY COMPLEX BAROO KARGIL BAROO KARGIL LADAKH 194103 | KARGIL | LADAKH | 194103 | ₹40.1 L+₹5.2 L (14.8%) | 3 | Rejected-Finance Not Being L1 bidder |
| 4 | 4₹41.2 L+₹6.3 L (18.0%)Rejected-Finance | ₹41.2 L+₹6.3 L (18.0%) | 4 | Rejected-Finance Not Being L1 bidder |
| 5 | 5₹41.6 L+₹6.7 L (19.3%)Rejected-Finance 00 HAIDARPUR JAMALPUR ROAD SADAR JAUNPUR UTTAR PRADESH 222001 | JAUNPUR | UTTAR PRADESH | 222001 | ₹41.6 L+₹6.7 L (19.3%) | 5 | Rejected-Finance Not Being L1 bidder |
| Sl No | Description | Qty | Unit | M/S MBS TRADING CO L2 | M/S Ali Trading Co L3 | M/S. MAJUMDER CONSTRUCTION L4 | M/S. R.K. ENTERPRISES L5 | M/s.Alam Enterprises L1 | SAI ENGINEERING L6 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Exavation in trenches, 1.5m wide and n. exc. 1.5m in depth , fo foundation etc.n.exc 10 sqm on plan and n. exc 1.5 m in depth and gatting out in soft / loose soil for laying of cables all as specified and directed by Engr-in-charge. | 450 | Cum | 450 ₹2,02,500 | 465 ₹2,09,250 | 470 ₹2,11,500 | 455 ₹2,04,750 | 380 ₹1,71,000 Lowest | 485 ₹2,18,250 |
| 2.00 | Returnig , filling in, including spreading, leveling , watering and well ramming in layers not exc 25 cm in soft / loose soil complete all as specified and directed by Engr-in-charge. | 330 | Cum | 150 ₹49,500 | 165 ₹54,450 | 170 ₹56,100 | 200 ₹66,000 | 120 ₹39,600 Lowest | 185 ₹61,050 |
| 3.00 | Removing excavated material n. exc 50m and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed by Engr-in-charge. | 120 | Cum | 350 ₹42,000 | 365 ₹43,800 | 370 ₹44,400 | 400 ₹48,000 | 290 ₹34,800 Lowest | 380 ₹45,600 |
| 4.00 | Material and labour for sand cushioning / sand covering for underground cable protection and consolidated and compected with clean dry sand complete all as specified and directed by Engr-in-charge. | 120 | Cum | 2,800 ₹3,36,000 | 2,950 ₹3,54,000 | 3,500 ₹4,20,000 | 3,000 ₹3,60,000 | 2,400 ₹2,88,000 Lowest | 3,550 ₹4,26,000 |
| 5.00 | Supply and lay in trenches brick, common burnt in clay, building brick, sub class 'B' designation 75 for cable protection all as specified and directed by the Engr-in-Charge. | 10 | Per 1000 No.s | 8,000 ₹80,000 | 7,500 ₹75,000 | 7,100 ₹71,000 Lowest | 8,100 ₹81,000 | 7,800 ₹78,000 | 7,200 ₹72,000 |
| 6.00 | Supplying and laying un-reinforced precast concrete cable cover, class HVP, type 1 with peak, size 300mm x 180mm x 40mm all as specified and directed by the Engr-in-Charge. | 2,222 | Each | 125 ₹2,77,750 | 130 ₹2,88,860 | 120 ₹2,66,640 | 150 ₹3,33,300 | 110 ₹2,44,420 Lowest | 130 ₹2,88,860 |
| 7.00 | Supply, laying, jointing and testing of electric cable, heavy duty 11KV (E) grade of size 95 Sqmm 3 core, XLPE insulated, screened with sound compacted aluminium conductor, conductor screening with extruded semi-conducting layers insulation screening with copper tape covers laid up with PVC (ST-2) extruded inner sheathing galvanised steel strip armoured PVC (ST-2) outer sheathed cable conforming to IS-7098(Part-II) amended, laid in trenches/cable duct complete all as specified and as directed. | 400 | RM | 1,800 ₹7,20,000 | 1,900 ₹7,60,000 | 1,980 ₹7,92,000 | 2,000 ₹8,00,000 | 1,650 ₹6,60,000 Lowest | 2,010 ₹8,04,000 |
| 8.00Supply &Laying only in trenches,fix on pole or passing through pipe and testing LT , XLPE insulated (heavy duty) PVC elecric cable with aluminium conductor , 1100 volte grade , cross-sectional area including taking out U/S LT cable and and aluminium cable lugs of suitable size and cable gland of suitable size and ratings for the following sizes:-. | |||||||||
| 8.01 | (a) 400 Sqmm 3.5 core | 60 | RM | 3,950 ₹2,37,000 | 4,050 ₹2,43,000 | 3,500 ₹2,10,000 Lowest | 4,000 ₹2,40,000 | 3,700 ₹2,22,000 | 3,600 ₹2,16,000 |
| 8.02 | (c) 95 sqmm 3.5 core complete | 350 | RM | 1,100 ₹3,85,000 | 1,220 ₹4,27,000 | 1,210 ₹4,23,500 | 1,200 ₹4,20,000 | 1,020 ₹3,57,000 Lowest | 1,220 ₹4,27,000 |
Tender Value
₹35.5 L
EMD Value
₹71,000
Closing Date
13 Jun 2026, 6:00 pmClosed
CWE (AF) Panagarh
HQ CWE AF PANAGARH MILITARY ENGINEER SERVICES AIR FORCE STATION ARJAN SINGH PO AIR FORCE PANAGARH DIST BURDWAN WEST BENGAL PIN 713155
PROVN OF UPGRADATION OF EXTERNAL ELECTRIC SUPPLY AND ALLIED WORKS AT AF STN PURNEA UNDER AGEIAFPURNEA
2026_MES_765516_1
84108/PUR/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Purnea
As per Tender documents
8 documents required · 8 mandatory
₹500
AGE(I)(AF)PURNEA
₹71,000
Yes
20 Jul 2026
19 May 2026
15 Jun 2026
19 May 2026
13 Jun 2026
5 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Exavation in trenches, 1.5m wide and n. exc. 1.5m in depth , fo foundation etc.n.exc 10 sqm on plan and n. exc 1.5 m in depth and gatting out in soft / loose soil for laying of cables all as specified and directed by Engr-in-charge. | 450 | Cum | - | - |
| 2 | Returnig , filling in, including spreading, leveling , watering and well ramming in layers not exc 25 cm in soft / loose soil complete all as specified and directed by Engr-in-charge. | 330 | Cum | - | - |
| 3 | Removing excavated material n. exc 50m and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed by Engr-in-charge. | 120 | Cum | - | - |
| 4 | Material and labour for sand cushioning / sand covering for underground cable protection and consolidated and compected with clean dry sand complete all as specified and directed by Engr-in-charge. | 120 | Cum | - | - |
| 5 | Supply and lay in trenches brick, common burnt in clay, building brick, sub class 'B' designation 75 for cable protection all as specified and directed by the Engr-in-Charge. | 10 | Per 1000 No.s | - | - |
| 6 | Supplying and laying un-reinforced precast concrete cable cover, class HVP, type 1 with peak, size 300mm x 180mm x 40mm all as specified and directed by the Engr-in-Charge. | 2,222 | Each | - | - |
| 7 | Supply, laying, jointing and testing of electric cable, heavy duty 11KV (E) grade of size 95 Sqmm 3 core, XLPE insulated, screened with sound compacted aluminium conductor, conductor screening with extruded semi-conducting layers insulation screening with copper tape covers laid up with PVC (ST-2) extruded inner sheathing galvanised steel strip armoured PVC (ST-2) outer sheathed cable conforming to IS-7098(Part-II) amended, laid in trenches/cable duct complete all as specified and as directed. | 400 | RM | - | - |
| 8Supply &Laying only in trenches,fix on pole or passing through pipe and testing LT , XLPE insulated (heavy duty) PVC elecric cable with aluminium conductor , 1100 volte grade , cross-sectional area including taking out U/S LT cable and and aluminium cable lugs of suitable size and cable gland of suitable size and ratings for the following sizes:-. | |||||
| 8.01 | (a) 400 Sqmm 3.5 core | 60 | RM | - | - |
| 8.02 | (c) 95 sqmm 3.5 core complete | 350 | RM | - | - |
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.49 MB
Tender.pdf
Tender Documents • 2.04 MB
BOQ_857409.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .