Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.1 LAccepted-AOC HOUSE NO 11 VILLAGE POST SAIGAON THE BHALKI DIST BIDAR STATE KARNATAKA 585416 | BIDAR | KARNATAKA | 585416 | L1 | Accepted-AOC LOWEST TENDERER | |
| 2 | L2₹27.7 L+₹1.6 L (6.01%)Rejected-Finance | L2 | Rejected-Finance Greater than L1 | |
| 3 | L3₹28.3 L+₹2.1 L (8.22%)Rejected-Finance 601 A WING SAI PARAMOUNT APARTMENT SHRADDHA VIHAR COLONY INDIRANAGAR NASHIK NASHIK MAHARASHTRA 422009 | NASHIK | MAHARASHTRA | 422009 | L3 | Rejected-Finance Greater than L1 | |
| 4 | L4₹28.4 L+₹2.2 L (8.49%)Rejected-Finance SHOP NO 04 AKBAR ARCADE NEAR INDRAYANI BRIDGE LONAVLA PUNE 410401 | PUNE | MAHARASHTRA | 410401 | L4 | Rejected-Finance Greater than L1 | |
| 5 | L5₹29.1 L+₹3.0 L (11.3%)Rejected-Finance BHAIRAVNATH NAGAR AT KUSGAON POST LONAVLA 410 401 DISTT PUNE | PUNE | MAHARASHTRA | 410401 | L5 | Rejected-Finance Greater than L1 |
Tender Value
₹26.3 L
EMD Value
₹52,600
Closing Date
4 Sept 2024, 6:00 pmClosed
Gaurav Tiwari, IDSE
GE (I) (NAVY), INS SHIVAJI - POST, LONAVLA -410402
ADDN ALTN AND IMPROVEMENTS TO BLDG NO P 467 AT SMQ AND PROVN OF 15 AMPS POWER SOCKET AND ASSOCIATED WIRING FOR UPS SUPPLY TO HEAVY DUTY PRINTERS IN IPS BLDG NO 344 AT INS SHIVAJI LONAVLA
2024_MES_664009_1
GE/LONAVLA/8230/E8
Open Tender
Civil Works
Item Rate
180 days
GE (I) (NAVY) LONAVLA
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GEINDEPNAVYLONAVLA
₹52,600
Yes
14 Dec 2024
5 Jul 2024
7 Sept 2024
5 Jul 2024
4 Sept 2024
20 Jul 2024
15 Jul 2024 - 19 Jul 2024
Amount
Taking down cement or cement lime plaster, any description on brick or stone walls, etc, including raking out joints, hacking for key, scrubbing down with water etc.
M&L for rendering 10 mm thick cement plaster in CM 1:6 on brick work/concrete surfaces finished even and smooth (without using extra lime or cement) complete all as specified and directed by Engineer-in-charge.
M&L for rendering 20mm thick cement plaster in CM 1:4 using water proofing compound on brick/ stone surfaces finished fair and even without using extra cement etc complete all as specified and directed by Engineer-in-charge. Note : Water proofing compound and will be measured and paid separately.
M&L for rendering 5 mm thick cement plaster in CM 1:3 on ceiling or concrete surfaces finished even and smooth (without using extra lime or cement) complete all as specified and directed by Engineer-in-charge.
M&L for preparation of new plastered surface of ceiling and applying three coat of white wash complete all as specified and directed by Engineer-in-charge.
Material and labour for complete removal of existing treatment of old surface area and ,newly platered surface internally wall surfaces and praparing and applying two coat of acrylic distember 1 quality (ready mix) having VOC content less than 50gms/litr ,of approved manfacturer,of required shade and colour complete as per manfacturer's specification over alkali resistance primimg paint primer over 3.00 mm thick white cement based wall care putty smooth finish etc complete all as specified and directed by Engineer-in-charge. Note:necessary saftey precautions , ladder/scaffoliding etc arranged by contractor.
Material and labour for newly platered external surface of wall surfaces and praparing and applying two coat of weather coat paint over alkali resistance primimg paint one coat of primer smooth finish etc of approved make & shade on walls and other places complete all as specified and directed by Engineer-in-charge. Note:necessary saftey precautions , ladder/scaffoliding etc arranged by contractor.
M&L for complete removal of existing treatment of old decorated ceiling surfaces and applying three coat of white wash complete all as specified and directed by Engineer-in-charge.
Dismantling of floor, hearth or wall tiling including cement mortar bedding complete all as specified and directed by Engineer-in-charge.
M&L Non Skid ceramic coloured tiles 7 to 8 mm thick (desined pattren) (square/ rectangular) area of each tile exceeding 0.11Sqm but not exceeding 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed by Engineer-in-charge.
M&L for Screed bed or bedding layer of mortar 15mm thick in CM (1:4) for laying floor tiles complete all as specified and directed by Engineer-in-charge.
M&L Glazed ceramic coloured tiles in vertical surfaces (desined pattern)350 x 250x 7 to 8 mm/ 450 x 350 x 7 to 8 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match
M&L for rendering 10mm thick in CM 1:3 as in backing coat of as in skirting and glazed tiles/ facial tiles in walls complete all as specified and directed by Engineer-in-charge.
Dismantling stone slabs and tiles of any descritpion or thickness in floors apron etc laid bedded in any mortar complete all as specified and directed by Engineer-in-charge.
M&L machine cut granite 16-20 mm thick (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills,cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade complete all as specified and directed by Engineer-in-charge.
S&F machine cut and machine polished, green marble, 16-18mm thick in single piece as in cooking platform bedded, window cill,Jambs, Trade, Riser, landing etc jointed and pointed with neat grey cement slurry and pointed with coloured or white cement with pigment to match over and including backing coat of rendering 10 mm thick in CM 1:4 all as specified and directed.
Taking down steel/aluminium windows/ventilator of any type any size complete with all fittingscomplete all as specified and directed by Engineer-in-charge.
S&F Powder coated aluminium three track, three shutter (equal width) type window miniumum 15 micron anodised with frame made of aluminium sections of size 91.80 x 31.75 x 1.0mm and shutters made out of aluminium sections 39.4 x17.7 x 1.0mm without sash bars including necessary jointing cleats, glazing clips, rubber packing, anodised snap beadings, screws aluminium fittings lockings arragngements etc including 4.00mm thick sheet glass for glazed shutters and stainless steel wire cloth of 0.36mm nominal dia of wire and average width of aperture 1.40mm for wire gauge shutter complete all as specified and directed by Engineer-in-charge.
S&F powder coated aluminium ventilator partly fixed and partly louvered type without sash bar section as per minimum 15 micron anodised including necessary jointing, clip, rubber packing, anodised snap beading crews and 4mm thick pin headed glass etc complete all as specified and directed by Engineer-in-charge.
Dismantiling and removing sunken slab filling of brick bats/cinder/light weight concrete including plastering on sunken floor/sides of floor slab/tiles of toilets in all the floors including all the water and sanitary fixtures and removing all rubbish/debris outside MoD land as per instruction complete all as specified and directed by Engineer-in-charge.
The suken floor RCC slab including sides to the full extent of sunken portion in upper floor shall be prepared and plastered with 15 mm thick cement plaster in CM 1:3 with water proofing compound as per manufacturer's instructions and finished even and smooth without using extra cement. When the plaster is cured and dried up, apply a uniform coat of blown grade bitumen 85/25 @ 1.2 kg/Sqm confirming to IS 702 over a coat of primer @ 0.70 Kg.Sqm over plastered surface complete all as specified and directed by Engineer-in-charge. Note :- Integral water proofing compound shall be measured and paid separately as "Supply only".
Water proofing treatment to Sunken floor slabe complete as specified bellow and as directed. (a) Provide and lay 3mm thick APP modified torch applied prefabricated five layer water proofing membrane weight not less than 3.60 Kg/Sqm. (b) Apply a uniform coat of blown grade bitumen 85/25 @ 1.2 Kg/Sqm confirming to IS 702 of the surface area. complete all as specified and directed by Engineer-in-charge.
M&L for PCC lean concrete 1:5:10 type E2 laid in layers of not more than 100 mm thick tamping etc complete all as specified and directed by Engineer-in-Charge.
M&L for 50mm thick PCC 1:2:4 type B0 12.5mm graded stone aggregates as padding concrete over lean concretecomplete all as specified and directed by Engineer-in-charge.
Completely removing existing water proofing treatment of any descriptions and any type including top layer of plaster / china mosaic wherever occurs over roof and chhajja surfaces and scrubbing the surface with wire brush and cleaning wash down with water to receive new cement plaster / PCC layer and removing the waste material / debris to a distance exc. 1500m but n.exc. 2000m etc complete all as specified and directed by Engineer-in-charge.
M/L for rendering 15mm thick in CM 1:4 on concrete roof and chajja surface to get a uniform level surface for laying of membrane treatment complete all as specified and directed by Engineer-in-charge.
M/L for PCC 1: 2 : 4 type B-1 (using 20mm graded agg) for PCC padding on RCC roof surface finished even and smoother using extra cement all as specified and directed by Engr-in-Charge.
M/L for applying oil based bituminous primer @ 0.10 Kg/Sqm providing and laying 4mm thick. APP modified water proofing membrane weighing not less than 4kg/sqm re-inforced with non woven polyester matt weighing not less than 160 gm/sqm having softening point not less than 140 degree centigrade longitudinal tensile strength not less than 650 N/Sqm, tearing strength of 180N and with thermal insulation with the mineral / graved finish on upper side and laying with torches application and with 10 cm minimum lap in both direction length wise and width wise all as specified and directed by Engr-in-charge.
M&L for making the grooves 25mm wide and 50mm deep to 'V' section in existing walls/columns, roofs cleaning out and tacked the polymeric membrane in to the grooves, inserting chajja of PPGI sheet and sealed solidly with a hot mixture of bitumen and clean dry sand in the ratio of 1:1 by weight etc complete all as specified and directed by Engineer-in-charge.
Demolition of brick work/stone masonry built in cement mortar including all quoins arches, pillars all as directed.
M&L for brickwork with subclass 'B' bricks, straight or curved on plan exc 6m mean radius, built in cm 1:6 including demolition complete all as specified and directed by Engineer-in-charge.
M&L for rendering 15 mm thick cement plaster in CM 1:6 on brick work/concrete surfaces finished even and smooth (without using extra lime or cement) complete all as specified and directed by Engineer-in-charge.
Dismantling of water tanks exc 250& n exc 500 ltr capacity and removing from site complete all as specified and directed by Engineer-in-charge.
Dismantling of water tanks exc 500 & n exc 1000 ltr capacity and removing from site complete all as specified and directed by Engineer-in-charge.
S&F Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) 1000 ltrs capacity triple layered hoisted and fixed in position including 25mm dia float ball brass valve and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed by Engineer-in-charge.
S&F Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) 2000 ltrs capacity triple layered hoisted and fixed in position including 25mm dia float ball brass valve and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed by Engineer-in-charge.
Taking down 15mm dia bore GI steel tubing and connection including cleaning and making good dismantaled surface complete all as specified and directed by Engineer-in-charge.
S&F CPVC pipes, SDR 11, 20mm outer dia conforming to IS-15778 with all fittings such as Tee, bends, elbows, unions sockets and end oieces etc to receive the fittings and fixed with solvent on walls/ceiling or laying in floors complete all as specified and directed by Engineer-in-charge.
Taking down 20mm dia bore GI steel tubing and connection including cleaning and making good dismantaled surface complete all as specified and directed by Engineer-in-charge.
S&F CPVC pipes, SDR 11, 25mm outer dia conforming to IS-15778 with all fittings such as Tee, bends, elbows, unions sockets and end oieces etc to receive the fittings and fixed with solvent on walls/ceiling or laying in floors complete all as specified and directed by Engineer-in-charge.
Cutting chases,pinning in making good to facings of brick wall/concrete surface where required and pointing in cement mortar 1:3 to ends or edges of landings,steps,cills,sunshades,shelves,lintels,etc.,and cutting chasesfor concealed water tubing etc ,and making good ,cutting not exc 10cm girth complete all as specified and directed by Engineer-in-charge.
Dismantling /taking down PVC/Cast iron soil/waste pipes 100mm/75mm bore including all fitting like bends etc.
S & F 25 mm dia gate /sluice valve fixed to pipe complete all as specified and directed by Engineer-in-charge.
S & F 20 mm dia gate /sluice valve fixed to pipe complete all as specified and directed by Engineer-in-charge.
S&F Vitreous china wash down water closet (Padestal pattern) pan white including bolts and flush pipe, pedestal pan and trap including connections to drain (or outgoing pipe) and flushing pipe etc including seat cover closed type complete fixed in repairs complete all as specified and directed by Engineer-in-charge.
S&F Vitreous china white flat back of size 450x300mm wash basins, vitreous china (flat back or angle back type) any size, including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe fixed in repairs complete all as specified and directed by Engineer-in-charge.
S&F 10 litre PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete all as specified and directed by Engineer-in-charge.
S&F in repairs Brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and directed by Engineer-in-charge.
S&F Flush pipe of polyethylene of low or high density or PVC, 32mm dia for low level cistern complete all as specified and directed by Engineer-in-charge.
S&F PVC connection low density polythene pipe 15mm dia, 450mm long, heavy duty with PTMT nuts complete all as specified and directed by Engineer-in-charge.
S&F waste fittings 32mm dia, brass, chromium plated for glazedware sinks, basins, etc, with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified and directed by Engineer-in-charge.
S&F in repairs Bib taps, fancy type, chromium plated with crutch sc-rewed down, screwed for iron pipe or for brass ferrule and fixed 15 mm bore complete all as specified and directed by Engineer-in-charge.
S&F in repairs Pillar taps, fancy type, chromium plated, screwed down, high pressure, with or without lettered ‘Hot' or ‘Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed 15 mm bore complete all as specified and directed by Engineer-in-charge.
S&F in repairs Angle cock/stop cock, cast copper alloy, fancy type chromium plated, screwed down, high pre-ssure, with crutch or but-terfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed by Engineer-in-charge.
S&F in repairs toilet paper holder of stainless steel of size 10.5cm X 9cm fixed to walls with chromium plated (CP) brass screws complete all as specified and directed by Engineer-in-charge.
S&F in repair soap dish Cat No BA -25 of Prayag polymers Pvt Ltd or equivalent complete all as specified and directed by Engineer-in-charge.
S&F in repairs hand shower (Health Faucet), chromium plated with 8mm dia, 1.00m long flexible tube with wall hook all as complete all as specified and directed by Engineer-in-charge.
S&F in repairs acrylic cabinet mirror of size 450mm X600mm fixed with wooden plugs with cromium plated screw and cup washers, complete all as specified and directed by Engineer-in-charge.
S&F 20mm dia towel rail chromium plated 60cm long including bracket fixed with stainless screws complete all as specified and directed by Engineer-in-charge.
S&F in repairs brass chromium plated shower rose with or without swivel joints 75mm size, including fixing to steel pipe or union complete all as specified and directed by Engineer-in-charge.
S&F PVC (SWR) pipes of dia 110mm bore double socketed in any length with rubber ring joints fixed to walls complete all as specified and directed by Engineer-in-charge.
S&F PVC (SWR) pipe of 75mm bore in double socketed in any length with rubber ring joints fixed to walls complete all as specified and directed by Engineer-in-charge.
S&F PVC (SWR) Nahani /Floor trap, 75 mm dia of out let, plain with grating including jointing to waste pipe with solvent and cement concrete type B1 (1:2:4) & including removing old trap complete all as specified and directed by Engineer-in-charge.
S&F PVC (SWR) bends of 75mm bore in radius complete all as specified and directed by Engineer-in-charge.
S&F PVC (SWR) bends of 110mm bore in radiuscomplete all as specified and directed by Engineer-in-charge.
S&F PVC (SWR) branch piece double Y equal or unequal of 75mm bore in radiuscomplete all as specified and directed by Engineer-in-charge.
S&F PVC (SWR) branch piece double Y equal or unequal of 110mm bore in radiuscomplete all as specified and directed by Engineer-in-charge.
S&F Harrison curtain rails, anodised aluminium with fixing brackets, stops, rollers etc fixed in repair incl brakets complete all as specified and directed by Engineer-in-charge.
S&F stainles steel sink with drainage board , 1 mm thick sheet of steel grade AISI 304 for kitchen or laboratory, with plug, waste pipe, washers and wastes including bedding in cement morter to dwarf wall or including fixing CI cantilever bracket, connecting union to pipe etc., overall size 915 x 460 mm with bowl size 410 mm x 330 mm x 160 mm etc complete all as specified and directed by Engineer-in-charge.
S&F in repairs stainless steel kitchen plate rack of size 90cm X120cm X 1mm thick (18 gauge) conforming to the sample duly approved by Engineer-in-charge , complete all as specified and directed by Engineer-in-charge.
Removal of demolished material/ debries from site exc 5km & n.exc 10km as per direction of Engr -in charge complete all as specified and directed by Engineer-in-charge.
M&L for chajja repairs with 1:2:4 concrete for dubbing and 15 mm thick plaster with water proofing compound including dismantling loose plaster/ rcc and scaffolding and necessary formwork etc complete all as specified and directed by Engineer-in-charge.
S&F Roof trusses (framed), sunshade frames, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. confirming to Fe-410-W(Gde-E-250) including taking down complete all as specified and directed by Engineer-in-charge.
S&F framed work such as grills, gratings, etc, with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe 290 Gde E-165 complete all as specified and directed by Engineer-in-charge.
S&F for Pre- Painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/ cladding to wall, fixed with self tapping screws, including taking down complete all as specified and directed by Engineer-in-charge.
M & L for Preparation of old painted steel surfaces of any description having width/girth exceeding 10cm and apply two coat of synthetic enamel paint complete all as specified and directed by Engineer-in-charge.
Preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed by Engineer-in-charge.
Taking down existing doors/windows/ventilators (without taking off shutters and guard bars) of n exe 1.5 sqm complete all as specified and directed by Engineer-in-charge incl stacking the materials properly.
S&F for Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer and screwed with full body threaded star headed SS screws having minimum frame Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made complete all as specified and directed by Engineer-in-charge.
Providing Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 28 mm size comprising of virgin polymer and screwed with full body threaded star headed SS screws having minimum frame Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, complete all as specified and directed by Engineer-in-charge.
Taking down existing doors/windows/ventilators (without taking off shutters and guard bars) of exe 1.5 sqm but not exc 4 sqm etc complete all as specified and as directed incl stacking the materials properly.
S&F factory made Solid PVC Double door frame of size 50mm x 95mm made out of PVC supplying & Fixing in opening as complete all as specified and directed by Engineer-in-charge.
S&F Factory made Moulded door shutter consisting of solid core single leaf flush door of 30 mm thickness,lipped with 15 mm (5mm x 3) thick x30 mm width on the other stiles & bottom rails & 10mm (5mm x 2) thick x 30 mm width on other stiles & bottom rails , The inner panel laminated with 2 mm thick termite proof, water proof and fire resistant molded PVC sheet with 2,4,6 raised panel designs in different plain and / or prelam colours after routing the Moulded design on one side & 2 mm plain and / or prelam PVC sheet on other side using rubber adhesive on flush door & solvent cement adhesive on the PVC Lipping and manufacturer's specification & drawing etc complete all as specified and directed by Engineer-in-charge.
Ditto all as SI Item No 83 above but wire gauzed i.e pannel will be of wire gauze in lieu of single side prelam PVC sheet pannel. The wire gauze shall be wrapped on an addtional square 8 mm MS solid tube and and this tube shall be welded to MS tubes. The wire shall be streched to tighten firmily all as complete all as specified and directed by Engineer-in-charge.
S & F 100 mm size Butt hinges, cast brass, with mild steel hinge pin, bright polished and fixed, typeB-11 Complete all as specifiedand as directed by Engineer-in-Charge.
S&F 100mm long Extruded brass handles, fabricated type polishedComplete all as specifiedand as directed by Engineer-in-Charge.
S&F Brass barrel tower bolts, with cast or sheet barrel and rolled or cast bolts and fixed 200mm long complete all as specified and directed by Engineer-in-charge.
Taking down carefully unserviceable aluminium/copper point wiring (light, fan, socket or power) including unserviceable light fittings, switch board complete, switch sockets, ceiling roses, pendants, regulators, sockets, etc and removing materials from site and making good disturbed surfaces of walls, floors, etc complete all as specified and directed by Engineer-in-charge.
M & L for Point wiring with 1.5 Sqmm (nominal area), FRLS PVC insulated, multistranded, single core unsheathed, copper conductor cables passing through and including providing PVC casing caping with all fittings and accessories of PVC casing caping (like Tee, bend etc.) complete fixed to walls /ceiling etc. with and including 1.5 Sqmm (nominal area) FRLS PVC insulated, unsheathed, stranded, single core, copper cable green in colour as earth continuity wire connecting to common earth point including PVC terminal box fixed with suitable sizes cadmium plated iron screws and washers etc.for mounting switches, sockets, regulators etc complete for one light/fan/bell/buzzer point controlled by one ,one way switches complete all as specified and directed by Engineer-in-charge. One light point or one fan point or bell point controlled by one switch
One 3 pin socket outlet, 5 Amp independent
One 3 pin socket outlet, 5 Amp on the same board with other switches
One bell/buzzer point controlled by one push button on the same board with other switches or independent with cable 1.5 sq mm size.
All as per item No.89 here in before but wiring with cables of size 2.5 sqmm for wiring & cables of size 2.5 sqmm both (FRLS) as continuous earth wire for one 15 Amps, 3 pin Switch/Socket outlet on Independent board complete all as specified and directed by Engineer-in-charge. (Note : cutting chases & making good of disturbed surfaces shall be measured and paid separately).
S & F switch piano, 5 Amp, single pole, flush type one way 230 volts complete all as specified and directed by Engineer-in-charge.
S & F socket out let, 2 in 1, 3 pin, 5 Amps, 240 volts complete all as specified and directed by Engineer-in-charge.
S & F Switch socket combination, 2 in 1, 5 Amps, flush type, 240 volts complete all as specified and directed by Engineer-in-charge.
S & F Switch socket combination, 5 in 1, 5/15 Amps, 240 volts, flush type with fuse & neon incator complete all as specified and directed by Engineer-in-charge.
S & F Ceiling rose, 3 way PVC insulated body complete all as specified and directed by engineer in charge.
Supply and fixing ROD 1x18W (single side supply)for LED TUBE LIGHT T8 tube with polycarbonate bodycomplete all as specified and directed by engineer in charge.
Supply and fixing Batten 1x18W(single side supply)for LED TUBE LIGHT pre -coated CRCA sheet, end caps made up with engineering plastic complete all as specified and directed by engineer in charge..
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by engineer in charge..
S/F switch bell push, flush type 5 Amp.
S&F in repairs bell, electronic type AC, 230 Volts single pole.
M&L lamp holder, PVC/ poly carbonate type with black plate suitable for batten fittings.
Supply and fix new adore LED lamp 9 Watt confirming to Cat No LHLDBWH4L8R009 of Havell's or euivalent in Philips / Bajaj
Supply and fix Inverter Bulb LED lamp 9 Watt confirming to Cat No LHLDEGEDML8009 of Havell's or euivalent in Philips / Bajaj
Labour only for taking down and fixing repairs to Ceiling Fan with Fan regulator/Exhaust Fan, any Make & any Sweep Oiling, Greasing , removing all dust with painting and Rewinding of fan by super ennameled copper insulated wire as per existing gauge, varnishing, heating assembling and testing for serviceable condition complete all as directed by Engineer-in-Charge.
S&F in repairs fan regulator electronic step type complete all as specified and directed by engineer in charge.
Supply and fixing LED street light fitting 45 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
Taking down electric meter of any type and any make single/three phase by dismantling of all electrical connection checked the meter ,and Refixed same Nos of meter on wooden board in metal box of suitable size in same Nos of qtr after repair works completed
S&F in replacemen MCB DB SPN 8 ways double door with 240 Volt, 200 amps rated bus bar with all accessories flush in the wall including matching the existing surface complete all as specified and directed by Engineer-in-charge
S&F in repairs MCB SPN 40 to 63 AMP, 240 Volts 10KA 'C' curve , complete all as specified and directed by Engineer-in-charge.
S&F in repairs MCB SP 6 To 32 AMP, single pole 240 Volts 10KA 'C' curve, complete all as specified and directed by Engineer-in-charge.
Taking down sub main wiring of any size from the ceiling, walls etc and incl making good to disturb surface of wall and match with the existing surface.
M&L for sub main wiring drawing through PVC casing and capping with four runs of single core 6 sq mm and two runs of 6.0 sq mm as earth wire of stranded copper conductor PVC insulated and unsheathed cable of 1100 volts grade all as directed.Note:- Two run of 6 sqmm wire and One run of 6 sqmm wire and One run of PVC casing caping will be measured as one running meter.
M&L for earthling complete with galvanized GI earth plate electrode of size 600x600x6.00 mm, buried directly in ground (earth pit not less than 2.25 mtr below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level connected to galvanized earth lead wire 4.0 mm dia by means of volts, nuts, check nut and galvanized iron or steel including earth work in any type of soil, charcoal salt 15 cm around the earth plate as shown in electrical plate No 3 of SSR part1991,20 mm dia watering pipe medium grade 1.50 mtr long GI protection pipe light grade 15 mm dia from earth pit to main board (NOTE:- maximum length of GI protection pipe with each earth shall not be less than 7.5 mtrs) including necessary pit with cover , including testing on complition.
S&F in repairs switch socket combination 2 in 1, 3 pin 5/15 amp flush type universal.
S&F MCB DB TPN 4 ways double door with 440 Volt, 200 amps rated bus bar with all accessories flush in the wall including matching the existing surface all as specified and directed
Supply and fixing MCB TPN/FP 40 to 100 AMP 415V 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commissioning.
S&F in repairs MCB SPN 5-32 AMP, 240 Volts 10KA 'C' curve , complete all as specified and directed by Engineer-in-charge.
M&L for sub main wiring drawing through PVC casing and capping with Wiring alongwith earth wire size 2x4.0 sq. mm + 4 sq. mm earth wire of FRLS is PVC insulated copper conductor, single core cable in surface/recessed as required .Note:- Two run of 4.0 sqmm wire and One run of 4 sqmm wire and One run of PVC casing caping will be measured as one running meter.
Supply lay and testing cable XLPE insulated screened beded,galvanized steel trip or wire armoured, electric power cables (heavy duty) 1100 Volt grade with stranded aluminium conductor of size 25 sq mm 4 core. Including taking down old unserviceable cable any size by dismantling of all electrical connection etc all as diercted.Note : Cable are laying in undergruond or on wall by saddle as per site requirment.
S&F in replacemen MCB DB SPN 4 ways double door with 240 Volt, 200 amps rated bus bar with all accessories flush in the wall including matching the existing surface all as specified and directed.Make:Havells QVE series or equivlent legerend/standard/indoasian
RK AND SONS CREATION (BID ID -3080974)
SAI SAMARTH ENTERPRISES (BID ID -3072740)
KGN builders (BID ID -3081668)
seema enterprises (BID ID -3081131)
Durga Enterprises (BID ID -3079411)
United Engineers and Contractors (BID ID -3078436)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .