| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.9 LAccepted-AOC RZ H 5 NANDA BLOCK MAHAVIR ENCLAVE PART 1 PAL AM SOUTH WEST DELHI DELHI 110045 | SOUTH WEST DELHI | DELHI | 110045 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹32.3 L+₹3.4 L (11.7%)Rejected-Finance 112 AMBALA ROAD NARAINGARH AMBALA 134203 | NARAINGARH | AMBALA | HARYANA | 134203 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹33.6 L+₹4.6 L (16.0%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹38.1 L+₹9.1 L (31.5%)Rejected-Finance RAMA PARK A 121 BLOCK A UTTAM NAGAR WEST DELHI DELHI 110059 | DELHI | WEST DELHI | DELHI | 110059 | L4 | Rejected-Finance Other than L1 |
| Sl No | Description | Qty | Unit | HANUMAN BUILDERS L4 | M/s. Kansal Construction Co. L3 | SM CONSTRUCTION COMPANY L1 | J S CONSTRUCTION CO L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | Excavating in post holes (or similar holes) each n.exc 0.5 cum getting out returning , filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25cm, watering and removing surplus soil to a distance n.exc 50 m and making good in hard/dense soil complete all as specified and directed | 20 | Each | 400 ₹8,000 | 200 ₹4,000 | 200 ₹4,000 | 90 ₹1,800 Lowest |
| 2.00 | M & L PCC (1:3:6) type C-2 ( using 40mm crushed stone aggregate) as in foundation filling and mass concrete complete all as specified and directed. | 2 | Cum | 4,000 ₹8,000 | 4,200 ₹8,400 | 3,200 ₹6,400 Lowest | 4,200 ₹8,400 |
| 3.00 | S&F steel work in tubular truses, purlins, rafters, struts, vertical members and similar work including special shape washers complete using ERW or induction butt welded tubes conforming to IS-1161-1979, grade St-240, Mild Steel plates complete all as specified and directed by Engr-in-charge. | 5,750 | Kg | 100 ₹5,75,000 | 90 ₹5,17,500 | 95 ₹5,46,250 | 88 ₹5,06,000 Lowest |
| 4.00 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed by Engr-in-charge. | 511 | Sqm | 720 ₹3,67,920 | 600 ₹3,06,600 | 450 ₹2,29,950 Lowest | 590 ₹3,01,490 |
| 5.00 | M&L for preparation of new steel surfaces of any description, not other wise described, over 10 cm width or girth and applying two coats synthetic enamel paint over a coats of red oxide primer complete all as specified and directed by Engr-in-charge. | 50 | Sqm | 100 ₹5,000 | 60 ₹3,000 | 30 ₹1,500 Lowest | 45 ₹2,250 |
| 6.00 | S&F precast machine pressed PCC interlocking paver block of 80 mm thickness, M-40 grade of any shape and size confirming to IS -15658-2006 with grey cement and pigment as approved over 50mm thick sand cushion and 100mm thick, plain cement concrete, type D-2, 1:4:8, (using 40mm graded stone aggregate) as in sub base flooring, surface finished even and rough to receive floor topping complete all as specified and directed by Engineer-in-Charge. | 100 | Sqm | 1,200 ₹1,20,000 | 540 ₹54,000 Lowest | 750 ₹75,000 | 850 ₹85,000 |
| 7.00 | M & L for 75 mm thick cement concrete 1:3:6 type C-2 (using 40 mm graded stone aggregate) as in plinth protection laid to slop of 1:12, finished surface even and fair without using extra cement with and including all necessary form work to divide the area in panels, finishing exposed edges fair or rounding or chamfering where directed and providing 6 mm wide joints through out the thickness of plinth protection duly filled with mastic filling (one part of hot bitumen 85/25 and three part of fine sand by weight) complete all as specified and directed by Engr-In-Charge. | 50 | Sqm | 450 ₹22,500 | 280 ₹14,000 | 150 ₹7,500 Lowest | 350 ₹17,500 |
| 8.00 | M&L for Brick work with subclass B bricks, staright or curved on plan exc 6.00 mtr mean radius, built in 1:4 cement mortar complete all as specified and as directed by Engr-In-Charge. | 20 | Cum | 4,800 ₹96,000 | 4,600 ₹92,000 | 3,200 ₹64,000 Lowest | 4,800 ₹96,000 |
| 9.00 | M&L for rendering in CM (1:6) 10 mm thick on other than fair faces of brick work or concrete surfaces etc including finished even and smooth without using extra cement including taking down cement plaster etc on brick wall or stone walls etc complete all as specified and directed by Engr In Charge | 200 | Sqm | 260 ₹52,000 | 160 ₹32,000 | 150 ₹30,000 Lowest | 190 ₹38,000 |
| 10.00 | M&L for preparation of new/old plastered or unplastered surface and applying two coats of distemper oil emulsion on walls over a coat of primer incl 1 mm thick wall care putty on walls complete all as specified and directed by Engr-In-Charge. | 500 | sqm | 60 ₹30,000 | 40 ₹20,000 | 30 ₹15,000 Lowest | 55 ₹27,500 |
Tender Value
₹43.6 L
EMD Value
₹87,260
Closing Date
15 Jul 2025, 6:00 pmClosed
GE (AF) SUBROTO PARK
GE (AF) Subroto Park, Delhi Cantt Delhi-110010
As described in Bill of quantities
2025_MES_714635_1
GE/SP/TOKEN-70/2024-25
Open Tender
Civil Works
Item Rate
120 days
GE (AF) SUBROTO PARK
As per NIT and tender documents
9 documents required · 9 mandatory
₹500
GE (AF) SUBROTO PARK
₹87,260
Yes
16 Sept 2025
14 Jun 2025
18 Jul 2025
14 Jun 2025
15 Jul 2025
3 Jul 2025
Amount
Excavating in post holes (or similar holes) each n.exc 0.5 cum getting out returning , filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25cm, watering and removing surplus soil to a distance n.exc 50 m and making good in hard/dense soil complete all as specified and directed
M & L PCC (1:3:6) type C-2 ( using 40mm crushed stone aggregate) as in foundation filling and mass concrete complete all as specified and directed.
S&F steel work in tubular truses, purlins, rafters, struts, vertical members and similar work including special shape washers complete using ERW or induction butt welded tubes conforming to IS-1161-1979, grade St-240, Mild Steel plates complete all as specified and directed by Engr-in-charge.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed by Engr-in-charge.
M&L for preparation of new steel surfaces of any description, not other wise described, over 10 cm width or girth and applying two coats synthetic enamel paint over a coats of red oxide primer complete all as specified and directed by Engr-in-charge.
S&F precast machine pressed PCC interlocking paver block of 80 mm thickness, M-40 grade of any shape and size confirming to IS -15658-2006 with grey cement and pigment as approved over 50mm thick sand cushion and 100mm thick, plain cement concrete, type D-2, 1:4:8, (using 40mm graded stone aggregate) as in sub base flooring, surface finished even and rough to receive floor topping complete all as specified and directed by Engineer-in-Charge.
M & L for 75 mm thick cement concrete 1:3:6 type C-2 (using 40 mm graded stone aggregate) as in plinth protection laid to slop of 1:12, finished surface even and fair without using extra cement with and including all necessary form work to divide the area in panels, finishing exposed edges fair or rounding or chamfering where directed and providing 6 mm wide joints through out the thickness of plinth protection duly filled with mastic filling (one part of hot bitumen 85/25 and three part of fine sand by weight) complete all as specified and directed by Engr-In-Charge.
M&L for Brick work with subclass B bricks, staright or curved on plan exc 6.00 mtr mean radius, built in 1:4 cement mortar complete all as specified and as directed by Engr-In-Charge.
M&L for rendering in CM (1:6) 10 mm thick on other than fair faces of brick work or concrete surfaces etc including finished even and smooth without using extra cement including taking down cement plaster etc on brick wall or stone walls etc complete all as specified and directed by Engr In Charge
M&L for preparation of new/old plastered or unplastered surface and applying two coats of distemper oil emulsion on walls over a coat of primer incl 1 mm thick wall care putty on walls complete all as specified and directed by Engr-In-Charge.
S&F Anodised aluminium frame (minimum 50 micron powder coating) for doors, windows, ventilators or in partitions with one or more rebates with or without sash bar including jointing, cleat glazing clips aluminum mongry etc fixing of sheet glass and particle board complete all as specified and directed.
S&F 5.5mm thick plain glass ordinary quality and glazing, surface area exc 0.50 sqm in each pane as in doors etc complete all as specified and directed by Engr-In-Charge.
S&F aluminium powder coated an (minimum thickness of powder coating 50 micron) as in window and ventilator shutters, sliding type three track, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber packing, anodised aluminum snap beading screws etc complete all as specified and as directed by Engr-In-Charge.
S&F powder coated aluminium doors shutters,( thickness of powder coating not less than 50 micron) alumonium section weighing 0.75 kg/m incl necessary joining cleats, glazing clips, rubber neoprene packing , handels 2 Nos in each door , hinges, anodised aluminium snap beading screws etc. complete all as specified and directed by engr-In-Charge.
Taking down cement or cement lime plaster on brick walls incl racking out joints hacking for key scrubbing down with water etc and removing the debries outside the MOD land complete all as specified and as directed by Engr -in - Charge.
M&L as in repair for Brick work with subclass B bricks, staright or curved on plan exc 6.00 mtr mean redius, biult in 1:4 cement mortar complete all as specified and as directed by Engr-In-Charge.
M&L for rendering CM (1:6) 15 mm thick on other than fair faces of brick work or concrete surfaces etc including finished even and smooth without using extra cement up to four storey height bldg complete all as specified and directed by Engr In Charge.
M & L for rendering 5 mm thick on ceiling in cement mortar 1:3 finished fair and even smooth without using extra cement complete all as specified and directed by Engr In Charge.
M&L for preparation of newly plastered or unplastered surface and applying two coats of distemper oil emulsion on walls over a coat of primer incl 1 mm thick wall or ceiling care putty on walls complete all as specified and directed by Engr-In-Charge.
M&L for prepration of old plastered or unplastered surfaces of walls and applying two coat of approved shade of oil emulsion distemper with 3mm thick elastomeric wall care putty on walls, including repairing of pot holes and cracks with putty, take it plaster if required complete all as specified and directed by Engr-in-Charge.
M&L for preparation on old plastered or unplastered surfaces of walls and applying two coat of exterior Apex/weather coat over a coat of primer any tint (colour as approved by GE) over putty including preparation of surface of wall, band/chajja/balcony up to four storey height building complete all as specified and dircted by Engineer in charge.
Taking out of APP modified water proofing membrane including mud puska complete on roof surface and surface properly cleaned by wire brush complete all as specified and as directed by Engineer-in-Charge.
M&L 15 mm thick screed bed or bedding layer of cement mortar 1:4 with liquid water proofing compound (use as per manufacturer instructions complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of plastered/concrete surfaces of roof and applying the under mentioned course of roof treatement complete all as specified and directed by Engineer-in-Charge.:- (a) Surface shall be throughly wire brushed, cleaned, washed, dried up properly and apply evenly a bituminuous primer coat conforming to IS @0.4 ltr /Sqm over concrete / plastered roof surface. (b) Applying evenly a tack coat of bitumen 85/25 grade @1.20 kg/ sqm. (c) Laying of 3mm thick APP membrane sheet (min weight 3 Kg/Sqm) consisting of a core of 160 gms/Sqm polyster non woven fabric mat protected on both sides with a high quality polymeric asphaltic mix again protected with thermo fusible HMHDPE FILM on dried primed surface by torch application method. APP membrane will normally be laid in length at right angle to the direction of slope. The over lap shall be minimum 100mm on longitudinal direction and 150mm on the transverse direction including cuttings, grooves etc. (d) Membrane bonded completely to the substrate & the over laps are then scaled/fused by flame. Note:- Roof treatement shall be done by the approved authorized applicators and guarantee of treatement shall be minimum 10 years complete all as specified and directed by Engr In Charge.
M&L for PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) mixed with water proofing compound as per manufacturer instructions laid 40 mm avg thickness as in padding over roof slabs for providing proper slope to the concrete padding, surface finished even and smooth without using extra cement complete all as specified and directed by Engr In Charge.
M&L for preparation of plastered/concrete surfaces of roof and applying two coats of water proofing paint with aluminium finish complete all as specified and directed by Engineer-in-Charge. .
M & L for removal and refixing water storage of tank of any capacity including all items like pipe, fitting, valve or other misc items which is required to refixing for serviciable of water supply complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches n.exc 1.5 m deep and 1.5 m wide for foundation etc not exc 10 sqm on plan and getting out in any type of soil complete all as specified and directed.
M&L for plain cement concrete 1:4:8 type D-2 mm (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete complete all as specified and directed
Returning, filling in including spreading levelling watering and well ramming in layers n. exc 25cm thick complete all as specified and directed
Removing surplus excavated materials to a distance not exc 50m and depositing where directed at a level not exc 1.5 above the starting point complete all as specified and directed
M&L for Brick work with sub class 'B' (best quality) old size brick straight of covered on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed
M&L for RCC M-25 (using 20 mm graded stone aggregate) as in foundation, including rafts, footings, foundation, beams, plinth beams, bases for columns, etc; basement slabs, under reamed piles and mass concrete complete all as specified and directed.
M&L for RCC M-25 (using 20 mm graded stone aggregate) as in slab, shelves etc complete all as specified and directed.
M&Lfor RCC M-25 (using 20mm graded stone aggregate) as in beams, cantilevers, lintels, over 1.5 m span complete all as specified and directed
M&L for RCC M-25 (using 20mm graded stone aggregate) as in columns, pillars, piers, posts and struts complete all as specified and directed.
M & L for RCC M-25 (using 20mm graded stone aggregate) as in chajjas and like complete all as specified and directed.
M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for flat and rough finished surface of concrete complete all as specified and directed
M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) for flat and rough finished surface of concrete complete all as specified and directed.
M& L for Formwork to sides of pillars, posts, struts, piers, columns and stanchions for flat and rough finished surface of concrete complete all as specified and directed
M & L for formwork to chullah hoods, chajjas, trough and similar items including edges finished rough surfaces of concrete complete all as specified and directed.
M & L for hardcore of broken stone or boulders of gauge n.exc.63mm,deposited,spread and levelled in layers n exc. 15 cm thick, watered and well rammed to a true surface complete all as specified and directed.
M&L for 75 mm thick PCC 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in sub base complete all as specified and directed.
M&L for 40mm thick PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in flooring, finished even and smooth with using extra cement complete all as specified and directed
M & L for rendering 15mm thick on brick wall or concrete surface in cement mortar 1:4 finished fair , even and smooth without using extra cement complete all as specified and directed.
M & L for rendering 5mm thick on ceiling in cement mortar 1:3 finished fair and smooth without using extra cement complete all as specified and directed.
M&L for preparation of newly plastered or unplastered surface and applying two coats of distemper oil emulsion on walls over a coat of primer incl 1 mm thick wall care putty on walls complete all as specified and directed by Engr-In-Charge.
M & L for applying three coat of white wash on newly plastered or unplastered ceiling surfaces including preperation of surfaces, complete all as specified and directed
M&L for preparation on new or previously untreated wall surfaces and applying two coats of cement base paint over a coat of cement primer complete all as specified and directed
S&F Mild steel bars 10mm dia and over, cut to length, bent to shape required including cranking, bending spiraly hooping ends binding with and including mild steel wire (aneealed) nit less than 0.9mm dia or securing with clips quality conforming to TMT bars complete all as specified and directed.
All as per item No 50 here in before but 5mm dia and over upto and including 8mm for stirrups
S & F of steel window with side hung shutters including box type hinges with steel handle, hold fast and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed.
All as per item No 52 here in before but without glazing bars as in fly proof window complete all as specified and as directed.
S & F Galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed
M&L mild steel for Framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors;gate, ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0 complete all as specified and directed
M&L for applying two coats of synthetic enamel paint over a coat of red oxide or zinc chromate primer including preparation of new steel or iron surfaces exc 10 cm width or girth, complete all as specified and directed complete all as specified.
S&F steel ventilators with centre hung shutter including hinges, steel peg stay complete all as specified and directed
S&F steel rolling shutters thickness of lath 1.0mm with out ball bearing , as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer and erected in position , indicated complete all as specified and directed
S&F Safety lever locks mild steel with 4 levers for rolling shutters complete all as specified and directed.
M & L for 75 mm thick cement concrete 1:3:6 type C-2, (using 40 mm graded stone aggregate) as in plinth protection laid to slop of 1:12, finished surface even and fair without using extra cement with and including all necessary form work to divide the area in panels, finishing exposed edges fair or rounding or chamfering where directed and providing 6 mm wide joints through out the thickness of plinth protection duly filled with mastic filling (one part of hot bitumen 85/25 and three part of fine sand by weight) complete all as specified and directed.
Supply only water proofing compound complete all as specified and directed.
M&L Glass dividing strips, 3 mm thick and 38 mm width inserted in postion confirm to design complete all as specified and directed.
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in any type of Soil compleye all as specified and directed
M&L for Chequered cement concrete tiles (rubber moulded with gloshy finishing) with grey cement and pigments 30cm x30cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors with 15mm thick bedding layer of cement sand mortar (1:6) including complete all as specified and directed by Engr In Charge.
M&L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 grade laid over and including 25mm sand cushion complete all as specified and directed
M & L for providing 100 mm thick cement concrete 1:4:8 type D-2 (using 40 mm grade stone aggregate) as in sub floor, sub base of floor finished even and rough complete all as specified and directed.
M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
M&L for preparation of plastered/concrete surfaces of roof and applying the under mentioned course of roof treatement. (a) Surface shall be throughly wire brushed, cleaned, washed, dried up properly and apply evenly a bituminuous primer coat conforming to IS @0.4 ltr /Sqm over concrete / plastered roof surface. (b) Applying evenly a tack coat of bitumen 85/25 grade @1.20 kg/ sqm. (c) Laying of 3mm thick APP membrane sheet (min weight 3 Kg/Sqm) consisting of a core of 160 gms/Sqm polyster non woven fabric mat protected on both sides with a high quality polymeric asphaltic mix again protected with thermo fusible HMHDPE FILM on dried primed surface by torch application method. APP membrane will normally be laid in length at right angle to the direction of slope. The over lap shall be minimum 100mm on longitudinal direction and 150mm on the transverse direction including cuttings, grooves etc. (d) Membrane bonded completely to the substrate & the over laps are then scaled/fused by flame. (e) Including 10mm thick rendering with 1:4 using WPC. (f) PCC 1:2:4 type B0 (using 12.5mm graded aggregate) roof kerbs, benching rounded or chamfered on edge including rounded or chamfered edges with necessary form work etc complete all as specified and directed Note:- This treatement shall be done by the approved authorized applicators and guarantte of treatement shall be for 10 years.
M&L PCC 1:2:4 type B1 (using 20mm graded stone aggregate) mixed with water proofing compound as per manufacturer instructions laid as in padding over roof slabs for providing proper slope to the concrete padding, surface finished even and smooth without using extra cement up to four stories complete all as specified and directed.
S&F for PVC (SWR) pipes 150 mm bore single socketed, in any length with solvent cement joints fixed to walls/laid in floors complete all as specified and directed by Engr In Charge.
S&F 150 mm dia Stack clamps out of 50 mm by 5mm flat iron and 16mm dia round iron stays,enlcuding bolts and nuts and securing ends of stays to wall or roof as per complete all as specified and directed by Engr In Charge.
S&F for PVC SWR bends for 150 mm bore pipe complete all as specified and directed by Engr In Charge.
S&F pre painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile stength of 550 Mpa as in roof covering/clading to wall, fixed with self tapping screws as specification complete all as specified and directed by Engr-in-Charge.
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc and making good disturbed surfaces of walls, floors, etc.complete all as specified and directed by Engineer-in-Charge.
M&L for point wiring for one light point controlled by one SP switch with single core PVC insulated unsheathed 1100 volt grade cable with multi strand copper conductor of size 1.5 Sq mm FRLS (Nominal area) drawn through and including non metallic rigid PVC conduit, medium grade, ISI marked not less than 20mm dia, concealed in wall, ceiling with GI saddles GI screws, rawl plugs (concealed conduit wiring) with all fittings including Tee, Junction boxes and provision of pressed steel terminal modular box powder coated of suitable size for mounting switch sockets and regulators and drawing continuous earth wire of PVC insulated unsheathed 1100 Volts grade cable with stranded copper conductor of size 1.5 Sq mm (Nominal area) complete all as specified and directed
All as per item No. 75 here in before but with one 3 pin 5 amps socket outlet on the same board with other switchs.
All as per item No. 75 here in before but one fan/exhaust fan and wall mounted fan point controlled by one SP switch.
All as per item No. 75 here in before but with one 3 pin socket outlet, 5/6 Amps in independent board with the cable 1.5 sqmm size.
All as per item No. 75 here in before but with 2.5 Sq mm cable for Independent bd one 3 pin 15 Amps socket outlet including single core 2.5 Sq mm wiring with copper conductor cables in PVC casing & caping for continuous earth wire connected to gang box of required size.
Supply and fix Switch Piano, Flush type Single Pole, One Way, 5/6 Amps, 230 Volts complete all as specified and as directed by Eng-in-charge.
S&F switch piano, flush type, 15 amps, single pole, one way suitable for 240V AC Complete all as specified and directed by Engineer-in-Charge.
S&F socket outlet 2 in1, 3 pin 5 Amps flush type suitable for 240V AC Complete all as specified and directed by Engineer-in-Charge.
S&F socket outlet 2 in1, 3 pin 15/16 Amps flush type suitable for 240V AC Complete all as specified and directed by Engineer-in-Charge.
S&F Exhaust fan steel body AC single 300 mm sweep 230 Volt, 1400 RPM with louver including necessary fixing arrangement for proper fixing in wall as per site requirement complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing ceiling roses, surface bakelite 65x50mm ,3 terminals , PVC/Polycarbonate, isolated body complete all as specified and directed at site.
Supply and fixing LED lights fitting 1x 20W 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
M & L for submain wiring with two run of single core 6.0 sqmm PVC insulated but unsheathed FRLS cable of specified size of multistranded copper conductor 1100 volts grade IS:694 marked and one run of 6.0 sqmm PVC insulated but unsheathed FRLS cable for earth continuty conductor drawn through and under suitable size of rigid non metallic PVC conduit , medium grade, ISI marked ( not less than 20 mm dia) complete with all acessories and fittings all laid/fixed concealed in wall/ceiling or surface in wall and surface conduit on ceiling, and also include the specified runs of specified size earth continuity conductor of similar type cable complete all as specified - 2 Runs of 6.0 Sqmm single core and one run of 6.0 sqmm single core cable as earth continuity conductor and 1 run of PVC pipe shall be measured as one unit for payment purpose.
Supply and fixing in replacement MCB distribution board with Bus bar 200A neutral link , earth bar made out of CRCA mild steel sheet surface mounting SPN 8 way 230 volts double door type regal gray horizontal type complete all as specified and as directed by Engineer-in-Charge. Note :- MCB shall be measured and paid seperately.
Supply and fixing 415V 10KA 'C' curve TPN 16 To 32 Amp miniature circuit breaker (MCB) complete with connection testing and commissioning complete all as specified and as directed by Engineer-in-Charge.
S&F MCB SP 5 to 32 Amps 10 KA, 240 volt 'C' Series complete all as specified and directed by engineer-in-charge.
S&F MCB SPN 40 Amps 10 KA, 240 volt 50 HZ 'C' Series complete all as specified and directed by engineer-in-charge.
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete.
M & L for submain wiring with two run of single core 10.0 sqmm PVC insulated but unsheathed FRLS cable of specified size of multistranded copper conductor 1100 volts grade IS:694 marked and one run of 10.0 sqmm PVC insulated but unsheathed FRLS cable for earth continuty conductor drawn through and under suitable size of rigid non metallic PVC conduit , medium grade, ISI marked ( not less than 20 mm dia) complete with all acessories and fittings all laid/fixed concealed in wall/ceiling or surface in wall and surface conduit on ceiling, and also include the specified runs of specified size earth continuity conductor of similar type cable complete all as specified - 2 Runs of 10.0 Sqmm single core and one run of 10.0 sqmm single core cable for earth continuity conductor and one run of PVC coundit shall be measured as one unit for payment purpose.
Supply and fixing in replacement MCB distribution board with Bus bar 200A neutral link , earth bar made out of CRCA mild steel sheet surface mounting SPN 12 way 230 volts double door type regal gray horizontal type complete all as specified and as directed by Engineer-in-Charge. Note :- MCB shall be measured and paid seperately.
Supply and fixing 415V 10KA 'B' curve SP 40 Amp miniature circuit breaker (MCB) complete with connection testing and commissioning complete all as specified and as directed by Engineer-in-Charge.
M&L for flame proof Point wiring one light/fan point controlled by one switch with single core PVC insulated unsheathed 1100 volt grade cable with multi strand copper conductor of size 2.5 Sq mm FRLS (Nominal area) drawn through and including metallic ERW conduit.ISI marked not less than 20mm dia, concealed in wall, ceiling with GI saddles GI screws, rawl plugs (concealed conduit wiring) with all fittings including drawing continuous earth wire of PVC insulated unsheathed 1100 Volts grade cable with stranded copper conductor of size 2.5 Sq mm (Nominal area) including conduit accessories complete all as specified and directed. Note: Cost for cutting, chasing and making good to existing surfaces are deemed to be included in the Quoted Rate.
S & F Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and as directed.
Supply and fix Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P+earth with all accessories complete all as specified and as directed.
S&F Flame proof junction boxes Epoxy finish LM6 (4 way) aluminium alloy housing with accessories complete all as specified and directed.
Supply and fix Flame proof Weather Proof, MCB DB SPN 4 way in Cast Aluminium alloy LM6 construction , as per IS : 2148, 240 V AC 50Hz with MCB SPN as incomer and DP/SP MCBs as out going with tinned copper bus bar, neutral link earth link, complete all as specified and directed .
S&F MCB 20A DP 250 volts,AC P+N+E, ISI Marked 10 KA complete all as specified and directed
S&F MCB 10A Singal Pole on-off , ISI Marked 10 KA complete all as specified and directed
Supply and fixing LED light fitting 2 x 16 watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size etc internally prewired complete all as specified and directed.
Supply and Fixing of Flameproof cum Waterproof LED Bulk Head light fitting of 30W, IP65 protection of Cast Aluminum alloy LM6 material with all accessories and Heat and Impact resistance toughen 'A' clear glass having Anti orrosive epoxy powder coated finish complete with all accessories pre wired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed
Supply and Fix Flame Proof class 1 Zone 1 Weather proof wall mounting Exhaust Fan 12" sweep, 1440 RPM single phase, suitable rated 240 Volts, 50 Cycles with CMR / CPRI hazardous area gas groups IIA/IIB with fabricated construction casing suitable propeller wheel with dynamically balanced blades to avoid frictional spark hazar dous front and rear wire guards - 01No, M-20 cable entry etc suitable for wall / bracket mounting arrangement etc, duly dark grey epoxy powder coated as per shade 632 of IS - 5 including writing MES NO. 2 CM height with synthetic enamelled black paint complete all as directed.
M&L for earthing complete with using copper electrode of size 60cm×60cm ×3.15mm thick burried directly in ground vertically,earth pit not less than 2.25 meter deep below ground level with top edge of the plate at depth not less than 1.5 m below ground level connected to and including 20×3mm copper strip as as earthing lead(upto 7.5m in length from earth plate) , by means of bolts,nuts,check nuts and washeres made out of Gl including protection pipe GI light grade 15mm size and watering pipe 25mm dia GI light grade all as shown on plate No 5 of SSR Part - I,connecting to earthing test point,including necessary earth work in any type of soil, PCC earth chamber made in PCC 1:3:6 Type C1 (using 20mm graded aggregate ),common salt,charcoal, CI funnel,earth pit cover in RCC 1:2:4 type B1 (using20mm graded aggregates), with MS rod 8 mm dia 150mm long reinforcement including necessary from work complete including necessary test on completion all as specified and as directed.
Supply, laying, jointing and testing LT cable XLPE Insulated ,screened, PVC bedded, galvanized steel strips armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminum conductor of size 16 sq mm 2 core with necessary cable glands at end, aluminium lugs fir connector complete all as specified and directed.
Material and labour for sand cushioning with dry river sand in trenches for cushioning of underground cable line including spreading, leveling, well ramming completed all as specified and directed.
M&L for brick, subclass 'B' well burnt, of size 230x115x75 mm laid dry flat in trenches for protection of LT cable, complete all as specified and directed by the Engineer-In-Charge
Supply and laying 80mm bore GI tube light grade as in cable protection pipe including all fittings complete all as specified and directed.
J S CONSTRUCTION CO (BID ID -3351269)
M/s. Kansal Construction Co. (BID ID -3351263)
HANUMAN BUILDERS (BID ID -3351097)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .