| 1.00 | Earth work open excavation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the excavated earth with a lead of 10 mts. within the compound in places shown by the departmental officers and clearing and levelling the site, etc., complete complying with standard specification. FOR DRAIN | 51.84 | M3 | 250 ₹12,960 | 226 ₹11,715.84 |
| 2.00 | grade Beam | 15 | M3 | 98 ₹1,470.43 | 97 ₹1,455.43 |
| 3.00 | Supply and filling crusher stone dust in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers. | 28 | M3 | 275 ₹7,700.11 | 270 ₹7,560.11 |
| 4.00 | Cement Concrete 1:4:8 (One Cement, Five sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc. complete complying with standard specification | 31.39 | M3 | 5,000 ₹1.6 L | 4,935 ₹1.5 L |
| 5.00 | Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X 60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed - 10 m 2 (P & D)Data 38 | 22.9 | M2 | 1,345 ₹30,795.12 | 1,335 ₹30,566.16 |
| 6.00 | Garde beam | 414.76 | m2 | 1,005 ₹4.2 L | 1,003 ₹4.2 L |
| 7.00 | Providing and laying in position ,Standardised Concrete Mix M-20 Grade in accordance with IS 456-2000, using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/m3 and maximum water cement ratio of 0.55, including admixture (plasticiser/ super plasticiser) in recommended proportions as per IS:9103 to accelerate , retard setting of concrete, improve workability without impairing strength and durability with about ( 5 Cu.m) 7730 kg of 20mm machine crushed stone jelly and with about (3.3 cu.m) 5156 kg of 10-12mm machine crushed stone jelly and with about (4.79 cu.m) 7670 kg of sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying ,Vibrating with mechanical vibrators , finishing ,curing , etc. and providing fixtures like fan clamps in the RCC floor/roof slabs wherever necessary without claiming extra, etc complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. ( No seperate payment will be made by the Department for the excess usage of materials). | 59.14 | M3 | 8,550 ₹5.1 L | 8,550 ₹5.1 L |
| 8.00 | Suppling and fabricating and placing in position MS (or) R.T.S. bar for reinforcement to all RCC works as per the design given including cost of steel and binding wire also in all floors. | 5,325 | Kg | 95 ₹5.1 L | 93 ₹5.0 L |
| 9.00 | Brick work in CM 1:5 (one cement & Five Crushed Stone Sand (M- Sand) using ground moulded chamber bricks of size 9"X4 3/8"X 2 3/4" standard specification including finishing, curing, etc., complete complying with standard specification - 100cft | 19 | M3 | 7,515 ₹1.4 L | 7,514 ₹1.4 L |
| 10.00 | Supplying and filling the basement with Good Earth filling in layers of not more than 15cm thick well rammed watered and compacted - etc., complete complying with standard specification. | 98 | M3 | 195 ₹19,110 | 190 ₹18,620 |
Tender Value
₹40 L
EMD Value
₹40,000
Closing Date
23 Jan 2026, 3:00 pmClosed
TCMC Zone V
Muthurangan Street
Renovation work Selaiyur Higher Secondary School at ward no 64 in Tambaram City Municipal Corporation
2026_DMA_645654_1
003/2025/E1/Z5
Open Tender
Civil Works
TCMC Zone V
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹40,000
29 May 2026
22 Jan 2026
23 Jan 2026
22 Jan 2026
23 Jan 2026
22 Jan 2026
Earth work open excavation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the excavated earth with a lead of 10 mts. within the compound in places shown by the departmental officers and clearing and levelling the site, etc., complete complying with standard specification. FOR DRAIN
grade Beam
Supply and filling crusher stone dust in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers.
Cement Concrete 1:4:8 (One Cement, Five sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc. complete complying with standard specification
Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X 60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed - 10 m 2 (P & D)Data 38
Garde beam
Providing and laying in position ,Standardised Concrete Mix M-20 Grade in accordance with IS 456-2000, using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/m3 and maximum water cement ratio of 0.55, including admixture (plasticiser/ super plasticiser) in recommended proportions as per IS:9103 to accelerate , retard setting of concrete, improve workability without impairing strength and durability with about ( 5 Cu.m) 7730 kg of 20mm machine crushed stone jelly and with about (3.3 cu.m) 5156 kg of 10-12mm machine crushed stone jelly and with about (4.79 cu.m) 7670 kg of sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying ,Vibrating with mechanical vibrators , finishing ,curing , etc. and providing fixtures like fan clamps in the RCC floor/roof slabs wherever necessary without claiming extra, etc complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. ( No seperate payment will be made by the Department for the excess usage of materials).
Suppling and fabricating and placing in position MS (or) R.T.S. bar for reinforcement to all RCC works as per the design given including cost of steel and binding wire also in all floors.
Brick work in CM 1:5 (one cement & Five Crushed Stone Sand (M- Sand) using ground moulded chamber bricks of size 9"X4 3/8"X 2 3/4" standard specification including finishing, curing, etc., complete complying with standard specification - 100cft
Supplying and filling the basement with Good Earth filling in layers of not more than 15cm thick well rammed watered and compacted - etc., complete complying with standard specification.
Plastering in C.M 1:5-12 mm thick with including cost and conveyance of all materials and including all labour charges etc complete
Supply and fixing of M.S Grills with Doors and Windows with one coat of Red oxide with Primer including all costs such as welding,grinding and fabrication charges, cost and conveyance of all materials to site etc,complete as per standard specification.
Paving the floor with Double charged Vitrified tiles of approved quality and colour of size 600x600x8mm thick of approved make, quality and colour in all floors over a base layer of cement mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 20mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications and as directed by the departmental officer. The colour & quality of tiles should be got approved by Municipal Engineer before use on work
Paving the floor with pre-polished Concrete Anti-Skid step tiles (Required shape and design) of 20mm thick of approved quality and colour laid in Cement Mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg/sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers.
Art painting for class room and entrance arch including cost and conveyance of all materials and labour charges etc complete.
Supplyandfixingof1200mm(48")ACceilingfancompletewithsteppedelectronic300Wregulatorwith1meterdownrod on the existing clamp sd 107
Supply and Fixing of 18W LED tube light including cost and conveyance of all materials and labour charges etc complete.
Supply and Fixing of 50W LED Focus light including cost and conveyance of all materials and labour charges etc complete.
Supply and Fixing of 36W LED Street light including cost and conveyance of all materials and labour charges etc complete.
Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS FRLS copper conductor of 1100 V grade in suitable heavy gauge MS conduit pipe on wall and ceiling with MS accessories with Module GI switch box in flush wall with 6A one way module switch with module front plate with ainting of Suitable colour with continuous earth wire connection of 1.5 sq.mm copper wire for Open MS conduit Light point / fan point (for electronic regulator) (5 points / Coil) Higher End sd 227
Supply and fixing of 5A 3 pin and 2 pin combined flush type wall socket with 5A flush type switch on suitable TW box sd 136
Supply and run of 4 of 4 sq.mm.PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade on 7/20 GI bearer wire for service connection mains SD 67
Providing granolithic floor finish of 25mm thickness with plain cement concrete 1:2:4 (One Cement, Two crushed sand (M-Sand) and Four aggregate) using 10 to 12mm gauge hard broken stone jelly including laying, finishing and the top rubbed smooth with power trawl, thread lining, curing etc. complete complying with standard specification and as directed by the departmental officers. (The rate is inclusive of necessary planking for panelling wherever necessary and as directed by the departmental officers)
Supply and Fixing of Rain Water Gutter including ncluding cost and conveyance of all materials and labour charges etc complete.
Providing & fixing PVC RAIN WATER DOWNFALL PIPE of the following dia with necessary T.W.Clamps Plugs, Shoes,Bemds, other clamps, screws nails etc.,complete complying with standard specification. The rate is inclusive of cost of removable iron gratings of appropriate size. The size of Teak Wood plugs used is 150X25mm in front & 200x75mm in rear (wall side) with a depth of 110mm. The pipe is to be fixed by means of "U" clamps at the centre of pipes to be fixed.110mm dia PVC Pipe [4 Kg/SqCm]
Supplying and Installing Metal False Ceiling using Fire Retardant Galvanized Steel Sheet Plain lay in tile size 600mm x 600mm, 0.5mm thick, powder coated on external surface and shall have flange on all four sides to rest on the exposed grids. The system to give 600mm x 600mm centre to centre ‘T’. The ‘T’ shall be not be dipped GI Tee Section 3600mm long main Tee. 24mm wide and cross Tee panels are formed by running main runner of ‘T’ section of size 30mm x 24mm powder coated at bottom at intervals with powder coating at bottom. Necessary provision of inter locking of ‘T’ section are made at required intervals not exceeding 200mm. The main runners are suspended from the ceiling by means of 4mm dia. GI rods fixed to the ceiling using anchor fasteners of 50mm x 8mm size with nylon inset and hooked to the main rubbers using clips. The last hangers at end of each rubber should not be greater than 600mm from the adjacent wall. The last panel shall be placed at the side wall using edge profile ‘L’ Angle of size 20mm x 20mm and fixed to the side wall the false ceiling should be fixed of same level and should present a neat look
Painting two coats for Exterior surface with approved Exterior Plastic Emulsion paint approved quality and colour over a priming coat, including thorough scrapping, clean removal of dirt, etc complete and including necessary plaster of paris, putty, wherever required etc, complete as per standard specification.
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.31 MB
BOQ_773857.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid