Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹61.5 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹69.1 L+₹7.3 L (11.8%)Rejected-AOC | L2 | Rejected-AOC L2 |
Tender Value
₹61.6 L
EMD Value
₹62,000
Closing Date
11 Sept 2024, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE, EDC, BDN
BUDAUN
99/EDCB/2023-24
2024_MVVNL_922160_4
99/EDCB/2023-24
Open Tender
Electrical Works
Item Rate
90 days
BUDAUN
AS PER TENDER DOCUMENT
3 documents required · 3 mandatory
₹3,540
A/c No. 1243002100806171, IFSC Code - PUNB0124300
₹62,000
23 May 2025
6 Sept 2024
12 Sept 2024
6 Sept 2024
11 Sept 2024
6 Sept 2024
6 Sept 2024 - 11 Sept 2024
Amount
The work of safe carriage of the following material from store center Nawada to work site under the jurisdiction of EDD-IV (Ujhani), Budaun Approx. distance upto 0-60 Km. Including safe loading and unloading.
11 KV 3X300 Sqmm XLPE Cable
11 KV 3X300 Sqmm XLPE Cable Box Indoor Jointing Kit
11 KV 3X300 Sqmm XLPE Cable Box Jointing Kit Outdoor
11 KV 3X185 Sqmm XLPE Cable
11 KV 3X185 Sqmm XLPE Cable Box Indoor Jointing Kit
11 KV 3X185 Sqmm XLPE Cable Box Outdoor
11 KV VCB O/G
11 KV VCB I/C
33 KV Fuse Set
33 KV Lightening Arrestor
33 KV VCB O/D
33 KV Control Pannel for Single Transformer
33 KV Control Pannel for Double Transformer
33 KV C.T., 400/200/1-1-1 Amp.
33 KV Line Isolator
PCC Pole Support 8.5 Mtr. Long
ST Pole Support 11 Mtr. Long
11 KV MS T-Off Channel
Top Channel (125x65x2240 mm)
11 KV Disc Insulator Composite 45 KN (T&C Type)
11 KV Pin Insulator Composite
11 KV X-Arm V Type
ACSR Rabbit Conductor
Stay Complete
Earthing Complete
ABC Cable (3x95+1x70+1x16) sqmm
ABC Cable (3x50+1x35+1x16) sqmm
3 Phase Distribution Box
1 Phase Distribution Box
L.T. LEAD LT XLPE Cable 1x400 Sqmm
G.I. Wire 6 SWG
G.I. Wire 10 SWG
Dismentaling of following old & damaged equipment’s as per norms complete in all respect
11 KV VCB O/G
11 KV VCB I/C
33 KV Lightening Arrestor
33 KV VCB O/D
33 KV Control Pannel
33 KV C.T., 400/200/1-1-1 Amp.
33 KV Line Isolator
Erection/Installation of following 11 KV Panel (VCB) in control room and cable joint of the panel to pole including earthing, grouting of Anchor bolt of Panel and making/repairing of pocket for cable to insert in panel from trench and fixing, taping of bus bar with wiring for PT. AC, DC connection including providing of AC & DC Supply.
11 KV VCB O/G
11 KV VCB I/C
Mounting and installation including mechanical/electrical fixing and adjusting of the following equipment on their respective structures including proper adjustment as per RESSPO Norms.
33 KV Fuse Set
33 KV Lightening Arrestor
33 KV VCB O/D
33 KV Control Pannel for Single Transformer
33 KV Control Pannel for Double Transformer
33 KV C.T., 400/200/1-1-1 Amp.
33 KV Line Isolator
Laying of control cable from 33 KV Panel to VCB 2x2.5 Sqmm Aramourd cable under ground in trench making proper complete in all respect as per RESSPO Norms.
Laying of control cable from 33 KV Panel to VCB 4x2.5 Sqmm Aramourd cable under ground in trench making proper complete in all respect as per RESSPO Norms.
Erection of Single PCC pole 8.5 Mtr. Long in H.T/L.T lines including fitting of all accessories as per RESSPO Norms (All necessary clamps, Nut & Bolts etc. shall be provided by the contractor for execution of work as per RESSPO Norms).
Erection of Single ST pole 11 Mtr. Long in H.T/L.T lines including fitting of all accessories as per RESSPO Norms (All necessary clamps, Nut & Bolts etc. shall be provided by the contractor for execution of work as per RESSPO Norms).
Grouting of PCC Pole 8.5 Mtr. Long & ST pole 11 Mtr. Long with 1:4:8 mixture in size (450x450x1500mm.) including cost of cement/C.C. & sand Required as per RESSPO Norms. (All Grouting material shall be provided by the contractor).
Erection/Fixing of stay set with stay wire and clamp as per RESSPO norms including binding. climbing, clamping, tightening and nozzeling etc. complete in all respect including its grouting in ratio 1:4:8 of cement, sand and C.C. and sand etc. as per RESSPO norms. All the grouting material shall be provided by the contractor.
The work of driving the earthing electrode and making connections with GI wire.
Dismentaling of following old & damaged Line as per norms complete in all respect
ACSR Weasel Conductor
ABC Cable
Laying, Stringing, Sagging & Jumpring of Following Conductor complete in all respect as per RESSPO Norms.
ACSR Rabbit Conductor
ABC Cable (3x95+1x70+1x16) sqmm
ABC Cable (3x50+1x35+1x16) sqmm
L.T. LEAD LT XLPE Cable 1x400 Sqmm
Underground Laying of 11 KV 3x300 sq.mm XLPE cable in Single circuit complete in all respect along with road restoration.
Fixing of 11 KV 3x300 Sq.mm XLPE Cable Inoutdoor jointing kits after carefully removing the insulation of the cable duly plumbing and taping of cable providing, fixing and crimpling of proper size good quality lugs and complete work.
Fixing of 11 KV 3x300 Sq.mm XLPE Cable outdoor jointing kits after carefully removing the insulation of the cable duly plumbing and taping of cable providing, fixing and crimpling of proper size good quality lugs and complete work.
Underground Laying of 11 KV 3x185 sq.mm XLPE cable in Single circuit complete in all respect along with road restoration.
Fixing of 11 KV 3x185 Sq.mm XLPE Cable Inoutdoor jointing kits after carefully removing the insulation of the cable duly plumbing and taping of cable providing, fixing and crimpling of proper size good quality lugs and complete work.
Fixing of 11 KV 3x185 Sq.mm XLPE Cable outdoor jointing kits after carefully removing the insulation of the cable duly plumbing and taping of cable providing, fixing and crimpling of proper size good quality lugs and complete work.
Fixing of danger board on each location and G.I. barbed wire including proper clamping as per RESSPO Norms. (Danger Board shall be provided by the contractor as per RESSPO Norms) complete in all respect.
Erraction/Fixing of Tailess Unit (600 A) (Tailess Unit shall be provided by the contractor as per RESSPO Norms). complete in all respect as per
Errection and commissioning of 3 Phase Distribution Box on the LT Poles (All the material required shall be arranged by the contractor for errection and commissioning of distribution boxes except distribution box).
Errection and commissioning of 1 Phase Distribution Box on the LT Poles (All the material required shall be arranged by the contractor for errection and commissioning of distribution boxes except distribution box).
Construction of 250 KVA T/F plinth 1.5x1.5x2 Mtr. for mounting T/F including foundation work (below ground 0.5 M), Brick work, RCC slab of 4” thickness and plastering in 1:6 ratio with 02 Nos channel pieces of 1.5 mtr long of size 100x50x6 mm compete in all respect as per RESSPO Norms.
Cage fencing of 250 KVA Plinth mounted transformer in Town areas to avoid electrical human/cattle accidents by fabrication of cage (1 Inch Sq wiremesh) made of 10 No gauge in suitable size angle iron frame of size 7.5'(L)x5'(W)x8’(H) by strenghtening of wire mesh 20x3 mm M.S. flat haorizentally as well as vertically, Grouting the panel with 1:2:4 cement/coorse send/brick ballast. The Frame should be bolted on angles at the four corners so that frame may be un-bolted/bolted at the time of replacement of the transformer. Provision of 1 gate should be there for maintenance of the transformer. Painting (1 coat of red oxide + 2 coat of Bus green enamel paint). The wire mesh should be earthed with 50x6 mm MS earthing strip with existing earthing of Transformer Body. All men, material and T&P provided by the contractor to complete the fabrication, transportation and installation.
Pipe Earthing of VCB (By boring of 4 inch diameter 20 m deep, 40 mm diameter A Class GI pipe is inserted to a depth of 20 m and a holed pipe of 1.5m length is inserted at the bottom, Tighten one end of the MS strip of size 50x6mm with the nut bolt with the neutral of the converter and weld the other end with the GI pipe inserted in the boring for earthing. Putting a socket on the upper part of the pipe (mouth) so that water can be poured into it to retain moisture. To complete the work contractor will provide all material, manpower, T&P, safe carriage of material to worksite. Above work will be carried out under supervision of concerned JE/SDO/EE).
Construction of Plinth & Foundation Suitable size of VCB compete in all respect as per RESSPO Norms (All material shall be provided by the contractor for construction of plinth & foundation).
Guarding of HT/LT/Telephone Line/Road/River crossing etc. and making net with difference of 1.00 Mtr. Completely including fixing of all channel/angle etc. with proper locking at each support. All type nut & bolt shall be provided by the contractor.
Fixing & Fabrication of CT Structure complete in all respect as per RESSPO Norms.
Fixing & Fabrication of PT Structure complete in all respect as per RESSPO Norms.
Repairing and overhauling of 33 KV VCB
Providing and Fixing of damaged Charging Garai and Non-bearing complete for 33 KV
Complete repairing of Tripping Machanish System and replacement of lever, spring, bush etc for 33 KV VCB
Providing and Fixing of 03 No. eye bolt and contactor 33 KV VCB
Providing and Fixing of handing and pumping relay for 33 KV VCB
Complete repairing of 3 KV VCB Motor and garari complete for 33 KV VCB
Providing and Fixing of damaged triping coil complete for 33 KV VCB
Providing and Fixing of fiber closing rod for 33 KV VCB
Providing of 2.5 mmsq. Pvc Copper wire and repairing of damaged burnt wiring complete of 33 KV VCB
Complete Overhauling, proper connection and providing and fixing of missing nut & bolts and proper functioning of 33 KV VCB
Repairing and overhauling of 33 KV Control Panel
Providing & Fixing of Local remote switch for 33 KV Control Panel
Providing & Fixing of indicator lamp 06 No. of different colour and proper connections
Providing & Fixing of 63 Amp. Kit-kat with tubular fuse 08 Nos. Complete and proper connection
Complete repairing proper connection and providing of missing nut & bolts for proper functioning of 33 KV Control Panel
Providing and laying of 4x2.5 mmsq. Control cable from 33 KV VCB to 33 KV control panel under ground in trench making proper
The following Decentralized material shall be provided by the contractor for execution of work as per RESPO Norms (the material shall be purchased from approved vendor of Discom).
Holding Clamps for S/s with Bolt & Nuts
Holding Clamps for Guarding Angle
Holding Clamps for LT T-OFF
11 KV F Clamp with Nut & Bolt
X-Arm Holding Clamp with Nut & Bolt
PG Clamp
Stone Pad
Danger Board
Barbed Wire
Distribution Box Clamps
Piercing Connector
LT Shackle Insulator
N&B for Shackle Insulator
LT Clamps with N&B for Shackle Insulator
Al. Lugs for 400 KV Sqmm Cable
Stay Insulator
11 KV Guarding Angle
Fuse Wire 23 SWG
Fuse Wire 27 SWG
LT Tailess Unit (600A)
Control Cable from 33 KV Panel to VCB 2x2.5 Sqmm Aramourd
Control Cable from 33 KV Panel to VCB 4x2.5 Sqmm Aramourd
Structure For CT
Structure For PT
Safe back carriage of Following item (if any) from work site to Store Center, Nawada, Budaun approx distance upto 0-60 Km including loading & unloading.
Material Jarjar Weasal Conductor
Material ABC Scrap
Material GI Scrap
33 KV VCB O/D Damage
Old Damaged CT/PT
33 KV Control Panel Damage
11 KV VCB O/D Damage
33 KV Line Isolator Scrap
M/S SUPER ENGINEERING TRADERS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .