Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L2₹44.6 L+₹2.0 L (4.45%)Accepted-AOC FLAT NO 93 POCKET 03 SECTOR 11 DWARKA NEW DELHI 110 075 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110075 | L2 | Accepted-AOC AOC | |
| 2 | L1₹44.9 LRejected-AOC | L1 | Rejected-AOC Rejected being L2 |
Tender Value
₹49.5 L
EMD Value
₹99,000
Closing Date
17 Jun 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (P) AF Gurgaon
GE (P) AF Gurgaon NEAR ATUL KATARIA CHOWK GURGAON
GE(P)AF/GUR-29/2021-22 PROVISION OF CERTAIN SANCTIONED WORKS AT 13 BRD, 27 ED, 31 MCU AT AF STN PALAM UNDER GE( P) AF GURGAON
2021_MES_444039_1
GE(P)AF/GUR-29/2021-22
Open Tender
Civil Works
Item Rate
272 days
GE (P) AF Gurgaon
AS SPECIFIED IN NIT
10 documents required · 10 mandatory
₹500
Yes
GE (P) AF Gurgaon
₹99,000
Yes
29 Jun 2021
19 May 2021
19 Jun 2021
19 May 2021
17 Jun 2021
3 Jun 2021
60 days
Amount
Schedule-A
Surface excavation in soft/loose soil not exc 30cm deep and getting out, avg 15cm depth complete all as specified and directed by Engr-in-Charge.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out in soft/Loose Soil, complete all as specified and directed by Engr-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 250 mm in soft/loose soil, complete all as specified and directed by Engr-in-Charge.
Removing excavated material n exc. 50 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed by Engr-in-Charge.
M&L Cement concrete in foundations, filling and mass-concrete Type D2 1:4:8 (40mm graded aggregate) all as specified and directed by Engr-in-Charge.
M&L for Reinforced cement concrete design mix M-25 as in slabs supports on walls, beams and columns and similar works all as specifie and directed by Engr-in-Charge.
M&L for Reinforced cement concrete design mix M-25 as in beams, cantilevers bressummers lintel over 1.5m span and similar works all as specifie and directed by Engr-in-Charge.
M&L for Reinforced cement concrete design mix M-25 as in chajjas and similar works all as specified and directed by Engr-in-Charge.
M&L for PCC 1:2:4 type B1 using 20 mm graded stone aggregate as in as in copping cill ,rounded or chamffered on edges including necessary form work complete all as specified and as directed by Engr-in-charge.
M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200m thick flat (Horizontal or sloping) all as specified and directed by Engr-in-Charge.
M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams in flat etc. and directed by Engr-in-Charge.
M&L for Formwork to chullah hoods, chajjas, troughs and similar items including edges all as specified and directed by Engr-in-Charge.
M&L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide all as specified and directed by Engr-in-Charge.
M&L for 10mm dia and over TMT bars, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified and directed by Engr-in-Charge.
M&L for 6 to 8 mm TMT bars cut to length bent to shape required incl cranking, bending, spirally for hooping for columns, hooking ends and binding with and incl mild steel wire (annealed) not less than 0.9 mm dia or securing with clips all as specified and directed by Engr-in-Charge.
All as per item No 15 hereinbefore but 5 m dia & over upto and incl 10 mm dia in stirrups spacers and binders.
M&L for Brickwork with subclass `B' bricks, straight or curved on plan exc 6m mean radius, built in Cement Mortar 1:6, complete all as specified and directed by Engr-in-Charge.
M&L for Brickwork with subclass `B' bricks, straight or curved on plan to any radush I half brick thick walls built in Cement Mortar 1:4, complete all as specified and directed by Engr-in-Charge
M&L for rendering 15 mm thick rendering in CM 1:6 on other than fare faces of brick work or concrete surfaces to be finised even and smooth (without using extra cement) all as specified and directed by Engr-in-Charge. ( waterproofing compound paid and measured separetly)
M&L for rendering 5 mm thick in CM 1:3 as in ceiling to be finised even and smooth (without using extra cement) all as specified and directed by Engr-in-Charge.
M& L for Preparation surfaces of walls and cornices spoiled by smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots by scraping and washing with water and applying two coat of cement base paint complete all as specified and directed by Engineer-in-Charge.
M&L for Providing, precast cement concrete in window or door cills, lintels, bressummers, steps, quoin blocks (for use with masonry), string courses, copings, kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, anchorage blocks, bonders (for stone walling), corbels, brackets, etc.(of any section indicated), with plain fair faces, including chamfers weatherings, throating etc. and setting in mortar complete with joints to match set in CM 1:4 type B1 1:2:4 (20mm gragded aggregate) all as specified and directed by Engr-in-charge.
M&L for preparation of new plastered ceiling surfaces and treated with three coats of white wash complete all as specified and as directed by Engr-in-Charge.
M&L for Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded plain colour PVC `C' channel heaving a PVC sheet strip of 20mm width suck inside with solvent cement for stiles and wood grain printed PVC Sheet used 5mm thick x 15mm wide PVC sheet beading used inside stiles and rails and decorative PVC beaading of 10mm x 10mm used instead of exposed portion of PVC sheet beading for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; supplying & fixing in the frame at site as per specification & drawing.
M&L for Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S Square tube, supplying & fixing in opening as per specification & drawing all as specified and directed by Engr-in-Charge.
S&F aluminium anodized grill DG 208 design as per approved pattern including aluminium beads etc complete all as specified and directed by Engr-in-Charge.
M&L for Figured glass, pin head type and glazing with oil putty in squares in exc 0.5 sq.m in each pane all as specified and directed by Engr-in-Charge.
S&F polyester powder coated aluminium frame/chowkhat for window/ ventilator of section 63.5x38.1 mm of 16 guage fixed in brick masonery or conrcrete work by necessary drilling and rawl plug aggangement etc incl polyster powder coated of any colour podwer coated aluminium window & ventilator shutters side hung type without sash bars aluminium with section 44.4x44.4mm of 16 guage including necessary jointing cleats, glazing clips, rubbers packing powder coated anodised aluminium snap beading, screw, powder coated aluminium anodised fittings such as peg stays 150mm long (1Nos), Hinges type B-21 100mm long (2Nos) suitable handle 1 Nos complete all as specified and directed by Engineer-in-Charge. (Glass and wire mess/ DG grill to be measured separately under appropriate item of sch A)
S&F polyester powder coated aluminium frame/chowkhat for door shutter of section 101.0x44.4 mm of gauge 16 fixed in brick masonery or conrcrete work by necessary drilling and rawl plug aggangement etc incl polyester powder powder coated aluminium door shutter top rain and middle rail of section 85x44.4 of 16 gauge and bottom rail of section 150x44.4 mm 16 gauge (all section of such type having arrangement for fixing glass/prelaminated board on one or both sides as required) incl aluminium powder coated fittings such handle (2 Nos each shutter), tower bolt, locks (mortise type lock) glazing clips, rubber packing, anodised aluminium snap beading screw, hinges type B-21 150mm long (3 Nos each shutter) etc and one door stopper two legged with each leaf (shutter) complete (Glass and prelaminated board/ DG grill to be measured separately under appropriate item of sch A) complete all as specified and directed by Engr-in-Charge (Make of aluminium section shall be hindalco/Jindal and equvalent)
S&F ISI marked hydraulically regulated door closer die cast body type complete suitable for door shutter width upto 1.50 mtr and weight between 61 to 80 kg complete all as specified and as directed by Engineer-in-Charge.
M&L, for 12 mm thick pre-laminated particle board, exterior grade, pre-laminated on both side with decorative choice laminations fixed between aluminium section with and including snap fitting aluminium clips of polyester powder coated along with the glass with rubber gasket, complete all as specified and directed by Engr-in-Charge. Make. Anchor/Kitply/Novapan
M&L 75 mm thick in PCC 1:3:6 type C-2 using 40mm graded aggregate as in Plinth protection including 6x10mm grove in every 3Mtr including bitumen mastic filling complete all as specified and directed by Engr-in-Charge.
M&L for providing 100 mm thick cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate as in sub base of floor complete all as specified and directed by Engr-in-Charge.
M&L for hardcore of guage exc 63mm boulders but n exc 100 mm depostie, spread and levelled in layers n exc 15cm thick, watered and rolled/ rammed to a true surface all as specified and directed by Engr-in-Charge.
M&L for non skid ceramic coloured tile 7 to 8mm thick (square/rectangular area of each tiles exceeding 0.11 Square but not exceeding 0.18 Sqm in floor over and including 10mm thick screed bed in cement motar 1:4 over 25mm thick PCC 1:2:4 type B-0 bedding, set and jointed in neat cement slurry and pointed in coloured cement to match the tile complete all as specified and as directed by Engr-in-charge.
M&L for glazed ceramic coloured tiles 300x200x7-8mm or 450x300x7-8 mm thick size as in walls set and jointed in neat cement slurry over and including 10mm thick in cement mortar (1:3) and pointed in coloured cement to match for work on vertical surface such as skirting / dado etc complete all as specified and as directed by Engr-in-charge.
M & L for Granite (of any type) work 16-18mm thick (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platform, verticle surfaces and any position in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite incl screed bed 15 mm th in CM 1:6 incl chamfering and rounding of edges where required all as specified and directed by Engr-in-Charge.
Supply only liquid water proofing compound mix cement concrete/cement plaster as per manufacture instruction all as directed by Engr-in-Charge. Make Dr fixit, M/S cico, Fosroc
S&F Precast Cement concrete manhole/drain cover of size 900mm x 600mm x 70mm thick srounded with steel strip 70x3mm Reinforced as per manufacturer's design in Munufactured proccess laid over existing drain complete all as specified and as directed by Engr-in-Charge. Make of SFRC Manhole/drain cover and frame : (a) M/s PS Concrete. (b) M/s KK Manhole.(c) Or equivalent as approved by GE. (ii) Contractor shall provide PV alongwith manufacturer test certificate of SFRC cover.
M&L for cement concrete 1:3:6 (20mm Graded crushed stone aggregate) Bed for drain pipes of bore 150mm including packing under and haunching against the sides of pipes after they are laid in foul condition and testing, complete all as specified and as directed.
S&F of Reinforced cement concrete drain Pipes 150 mm dia NP-2 , laid in trenches in foul condition, Jointed with collars in cement mortar 1:2 and tested, complete all as specified and as directed.
M&L for Soakage wells excavation in any type of soil, size of 1.8M dia x 3.0 M effective depth, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M-25 concrete including intercepting chamber and screen chamber made of brick masonary in CM, RCC cover slab in M25/SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats complete as per shown on drawing No CE(AF)/NGP/2004/TD/43 as directed by Engr-in-Charge.
S&F vitreous china wash basin hand white flat backsize 550x400 including cutting for and pinning in ends of brackets including fixing of 32 mm low dencity polylethyne pipes (LDPE)of pressure rating 6kg/cm2,cupling ,PVC connection with 15 mm dia PTMTcheknuts ,brackets all complete all as specified and as directed by Engineer-in-Charge.
S&F vitreous china coloured half stall urinal brass chromium plated brackets , fitting and waste coupling, CP bottle trap , urinal spreder , PVC connection etccomplete all as specified and as directed by Engineer-in-Charge.
S&F china wash, wash down water closet pan (pedestal pattern), including 10 ltr flushing cistern valveless, syphonia action type high level with inlete ball valve float and flush pipe etc all as spectified and directed by Engr-in-Charge.
S&F vitreous China squatting pan 'orrisa' pattern white colour of size 580x440mm with integral foot rests including provision of lime concrete including P traps complete all as specified and as directed by Engineer-in-Charge.
S&F 10ltr capacity PVC valveless syphonic action type flushing systern low level white with inlet ball valve ,float & handle including brackets complete all as specified and as directed by Engineer-in-Charge.
S&F health faucet (brass) with hook & 1.5mtr tube all as specified and directed by Engr-in-Charge. Make : jainko/ shakti/prayag
S&F PTMT waste pipe 31/32 mm bore 80 cm long complete all as specified and as directed by Engineer-in-Charge.
S&F for 75 mm dia cast iron spun soil, waste and vent pipes , in any length with or without ears, with cement joints, laid in trenches or in floors as in repair complete all as specified and directed.
S&F for 75 mm bore Bends (any radius) with oval access door diminishing pieces or tapers (larger bore measured) complete all as specified and as directed.
S&F for 110mm dia PVC ( SWR) pipes, single socketed, in any length with rubber ring, joints, laid in trenches or in floors fixing and repair etc all specifid and directed.
S&F for PVC (SWR) bends of 110mm radius with rubber ring, joints, laid in trenches or in floors fixing and repair etc all sped and directed.
S&F PVC(SWR) 110 mm dia of bore 'P' trap all as specified and directed by Engr-in-Charge.
S&F PVC(SWR) 75 mm dia of bore vent cowl all as specified and directed by Engr-in-Charge.
M&L for salt glazed stone ware gully traps square or rounded mouthed type ‘P’ of size 150x150mm embedded in PCC 1:3:6 type C-1 with and necessary brick work, plastering etc complete and connecting to pipe all as directed by Engineer-in-charge.
S&F Galvanised Steel Water Tubing 15 mm Bore (dia), ‘Medium Grade’ with all ISI marked Fittings, fixed on Walls, Ceiling or laid in Floors or any other Situ-ation, complete all as specified and directed by Engineer-in-Charge.
S&F repairs 15mm dia bib tap, chromium plated brass, fancy type with crutch or butterfly handle, screwed down complete all as specified and directed by Engineer-in-Charge (Make Seiko, Parko, Mark)
S&F repairs 15mm bore pillar cock cast copper alloy, chromium plated fancy type screwed down complete all as specified and directed by Engineer-in-Charge. (Make:- Seiko, Parko, Mark)
M&L for 60mm thick rubber moulded Machine pressed pre casted pressed cement concrete inter locking paver blocks glazed coloured up to 6mm on the top in any shape and size, strength not less than M-35 incl 25mm thick sand cushioning completed all as specified and as directed by Engr-in-Charge.
S&F repair 15mm dia stop cock cast copper alloy chromium plated brass,fancy type, high pressure with crutch or butterfly handle screwed down complete all as specified and directed by Engineer-in-Charge (Make:- Seiko, Parko, Mark)
S&F PVC connection 15mm size with PTMT Nuts of length 600 mm complete all as specified and directed by Engineer-in-Charge.
S&F Rotational moulded Polyethylene (HDPE) Water Storage Tank 1000 LITRE Capacity (Cylindrical Vertical with Closed Top), white in Colour, Three Layered Construction, hoisted and fixed in Position all specified in MES Schedule Part-I, including tank nipple, union and Lowering of unserviceable Water Storage Tank with 20mm float Valve any description complete all as specified and directed by Engineer in charge.
S&F CP towel rail 20mm dia 60cm long complete all as specified and directed by Engineer-in-Charge. Make : Seiko/Parko
S&F Looking mirror with PVC frame of size 50cm x 40cm with 3mm thick narrow board on back side. complete all as specified and directed by Engineer-in-Charge Make : Modi Guard/Atul/Swastik/Saint Gobain
S&F PVC grating 125x125mm square PTMT of minimum weight 150gms complete all as specified and directed by Engr-in-Charge.
Excavation in post holes n exc 0.5 cum each, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, ramming and removing surplus soil to a distance n exc 50 m and making good surface for soft/loose soil, completed all as specified as directed.
M&L for PCC 1:3:6 type C-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete etc., all as specified.
S &F for 0.50mm thick Pre-painted galvalume Aluminium zinc coated GI based coloured corrugated steel sheet having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping GI screws with rubber washer all as specified and as directed.
M&L for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St.-240, complete all as specified.
M&L for two coats synthetic enamals paint over a coat of red oxide/zinc chrome primer including preparation of new steel surface exc 10 cm in width or girth complete, all as specified as directed.
S&F for mild steel plate girder or single stanchions built up of one beam or channel section with flange plates, Structural Tube with caps/bases, splices angles brackets and cleats and other connections grade Fe-410-W (Gde-E-250) Quality -A complete all as specified and as directed.
S&F for MS FI including straightening, cutting, making holes and fixed in position with nut bolt and washer complete as in wind tie, all as specified and as directed of Grade Fe-290, (Gde-E-165), complete all as specified as directed.
S&F for rolled Steel sections as in main and cross beam, hip and jack rafter, purlins where connected rails etc with cleats or other connecting plates Grade Fe-410-W(Gde-E-250) quality-A, complete all as specified and as directed.
S&F for mild steel bolts exc 12mm n exc 20mm neck dia meter purpose made, with hexagonal or square head one end screwed the other or screwed both eands each screwed to be fitted with washers and one hexoganal or square not exc 30cm long, complete all as specified and as directed.
S&F for mild steel screw bolts diameter of neck 11mm to 15mm (machine made) with hexagonal or square heads at one end and screwed the other to be fitted with washers and one hexagonal or square nut n exc 5cm long, complete all as specified and as directed.
S &F 0.50mm thick Pre-painted galvalume aluminium zinc coated GI based coloured plain steel sheet as in ridge/vally gutter having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping GI screws with rubber washer all as specified and as directed.
S &F for 2.0mm thick glass reinforced fibre sheet as in roof/cladding fixed with self tapping GI screw with rubber washer complete all as specified and as directed.
M&L for GI frame work for seamless false ceiling comprising of GI perimeter chennel 0.55mm thick with two unequal flanges of 20 and 30 mm web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.90 mm thick having two equal flanges of 15mm each and web of 45mm seuspended from sofits at approx 900 mm centre to centre with and including ceiling section (not exc 1.2m length) of 0.55 thickness having kurld web of 50mm and flange of 26mm ech with lips of 10.5 mm fixed to the intermediate chennel with connecting clip across the intermediate chennel at 457 mm centre to centre, completed all as specified.
M&L for providing and fixing Gypsum Reinforced Gypsum Board (GRB) 12mm thick in ceiling fixed with screw as per manufacturer's instructions, complete all as specified and as directed by Engr-in-charge.
Taking down door/ window frame with shutter of area exc 1.5 butn exc 4.00 sqm and removing from site complete all as specified and as directed by Engr-in-charge.
Taking down door/window with shutter of area n exc 1.5 sqm each and removing from site complete all as specified and as directed by Engr-in-charge.
S&F aluminium colour powder coated door frame and shutter single or double leaf with partly glazed/pre laminated board exterior quality party glazed panels fabricated including aluminium powder coated beading, rubber and packing material and shall be drilling in existing wall and thrust bolt suitable size complete comprising the following:- (a) Aluminium colour powder coated door frame setion 101.60x44.45x1.93mm. (b) Aluminium colour powder coated vertical section in shutter 85x44.45x2.00 mm (c) Aluminium colour powder coated top rail & style shutter section 95.25x44.45x2.00mm (d) Aluminium colour powder coated handle 02 nos in each shutter 200mm long. (e) Aluminium colour a powder coated tower bolt 01 Nos in each shutter 150mm lonng (f) Aluminium colour powder coated middle lock rail/bottom rail section 150x44.45x2.00mm cat No 20002. Make Jindal (g) Six lever mortice lock brass Make : Godraj/Classic on in each door. (h) 12mm thick particular board (pre laminated both face) exterior grade ISI Marked (j) Tinted glass/plain glass 5mm thick Make: Sant gobain/modiguard. (k) Floor spring, Make Sandu. Note: if ground requirement for full glass or full panel contractor should provide as per direction of Engr-in-Charge.
S&F aluminium colour powder coated (shade or tint as directed by GE) window/ventiletor frame section 100x44x2mm fixed with thrust bolt in walls by drilling (any number of leaf) comprising the following :- (a) Aluminium coloer powder coated (shade or tint as directed by GE) Two shutter each size 44x44x2mm top/bottom/side style. (b) Aluminium colour powder coated butt hinges 4 Nos in each window 100mm sizes as per specified. (c) Aluminium colour powder coated tower bolt 4 Nos in each window 100mm long as per specified. (d) Aluminium colour powder coated handle 02 No in each window 100mm long as per specified. (e) Tinted glass 4mm thick with rubber beading, Make - Saint gobain /modiguard in all two shutter. complete all as specified and as directed.
Taking down cement plaster of any description on brick walls or on Concrete surfaces including racking out joints, hacking for key, scrubbing down with Water, etc and removing same from the site(s), complete all as specified and as directed (4th floor and scaffolding).
M&L Rendering 15mm thick in Cement Mortar 1:4 on Fair Faces of Brick Work or Concrete Surfaces, Plastered Surfaces finishing Fair and Even, complete upto 4th floor and scafolding complete all as specified and as directed.
M&L for preparing new plasted wall surface and applying two coat of oil emulsion over a coat of primer including 1 to 2 mm thick birla putty punning complete all as specified and as directed by Engineer-in- charge.
Taking down Plain/Corrugated sheet of any description including removing to store as directed.
Demolition of brick work masonry, built in cement mortar including all quoins, arches, pillars etc and removing rubbish from the premises complete all as specified and directed by Engineer-in-Charge.
M&L for Washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4 (1 cement: 4 coarse sand) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 cement: 1/2 coarse sand: 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings complete all as specified (Payment for providing grooves shall be made separately)
M&L for forming groove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete as specified and directed by Engineer-in-charge.
Dismentling of cement concrete (unreinforced) concrete in ground floors and pavings n exc 15cm thickness (below or above ground level) complete as specified and directed by Engineer-in-charge.
Pre construction Anti termite treatment for filling under floor/Plinth Protection by using CHLROPYRIPHOS 20% EC emulsion @5.00Ltr/Sqm complete as specified and directed by Engineer-in-charge.
Pre construction Anti termite treatment along the outer periphery of building by using CHLROPYRIPHOS 20% EC emulsion @2.25 0Ltr/Rm complete as specified and directed by Engineer-in-charge.
M&L Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing laid over 15mm thick screed bedding layer in CM 1:4 for laying in floor etc complete all as specified and as directed by the Engr-in-charge
M&L Machine cut kota stone 15-20mm thick as in skirting over 10mm thick rendering in CM 1:4 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing and finishing with mirror polishing complete all as specified and as directed by the Engr-in-charge.
Dismantling of wall and ceiling boards (Fibre, pulp, insulation, wooden etc.) or insulation board / slabs any thickness incl cover fillets complete all as specified and as directed by the Engr-in-charge.
S&F in repair mild steel works Fe-410 or 310 as in framed works such as door frame/ grills/ guard bar by using MS Tubes, Angles, Bars, Flats etc with ends of bars shoulders and or riveted or forged into spiked complete all as specified and as directed by the Engr-in-charge.
Removal of debris/malwa/ excavated surplus earth to a distance exc 10 Km but n exc 15.00 Km out side MD land and depositing at destination complete all as specified and as directed by the Engr-in-charge.
M&L for sub main wiring 2 run of size 6 sqmm PVC insulated electric power cable (heavy duty) 1100 volts grade with stranded copper conductor with, 4 sqmm PVC insulated copper conductor earth wire in concealed PVC conduit (2 run of 6 sqmm cable and one run of 4 sqmm wire and one run of PVC conduit will be measured as one unit) all as specified and directed.
Taking down of old unserviceable copper / aluminium point wiring (light, fan, socket or power) complete including fitting & fixture such as switches, ceiling roses, pendants, regulators, sockets,g etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions seperately) and making good disturbed surfaces of walls, floors etc complete.
M&L wiring sub main wiring concealed along with earth wire with the following size of HRFR PVC insulated and unsheathed multistranded copper conductor single core cable in concealed through 25 mm rigid not metallic PVC conduit heavy duty with 2 x 4 sqmm + 1 x 2.5 sqmm earth wire complete all as specified and directed by Engineer-in-charge. including cutting chesses pinning in making good to facing and pointing in cement morter 1:3 to the ends or cutting chesses for conceled point wiring and making good distrubed surface complete cutting not exceeding 4 cm girth and 4 cm width. Note:- Two run of cable and one length of PVC conduit with earth conductor shall be measured as a one length complete all as specified and as directed by Engr-in-Charge.
Material and labour for point wiring concealed in and including rigid non metallic PVC conduit, medium grade, ISI marked, 20 mm dia, with 1.5 sq mm FRHR PVC insulated & unsheathed, multi stranded copper conductor cable, single core, 1100 volts grade, including flush metal terminal boxes and factory fabricated (same make of modular type switches and sockets etc.) modular metal box, cover plates inner & outer, frames of suitable size and depth for modular wiring, FRHR insulated and unsheathed Multi standared copper conductor of 1.5 sqmm and connected to common earth dolly as continuous earth wire (Contractor shall concealed the conduit by making chases by cutter machine then after chiselling only) for one light point controlled by one switch complete all as specified and as directed.
All as per item No. 104 above but for 05 Amps socket outlet on same board.
All as per item No. 104 Above but One 5 pin, 5 Amps socket out let on independent board with 1.5 Sqmm cable & alongwith 1.5 Sqmm continous earth wire of copper conductor.
All as per Item No. 104 above One 15/20 Amps socket out let or for sheet metal enclosure on independent board with 4 sqmm cable alongwith 2.5 Sqmm continuous earth wire of copper conductor.
S&F ceiling rose,3 phase PVC polycarbonate complete all as specified and directed by Engr-in-Charge.
S&F Switch modular 10 Amps, single pole one way complete all as specified and directed by Engineer-in-Charge.
S&F Switch modular 16 Amps, single pole one way complete all as specified and directed by Engineer-in-Charge.
S&F modular type socket outlet shuttered modular type two module 3/5 pin, 6 Amps multtipurpose complete all as specified and directed by Engineer-in-Charge.
S&F modular type socket outlet shuttered modular type two module 3/5 pin, 16 Amps multtipurpose complete all as specified and directed by Engineer-in-Charge.
S&F as in replacement 20 Watt LED 4 feet tube light, 230 Volts, 50Hz, alongwith fixtures internally pre-wired including with diffuser complete with all connected accessories complete all as specified and as directed by Engr-in-Charge.
Supply,Laying and testing cable XLPE Insulated, screened,PVC bedded,galvanized steel strip or wire armoured, electric power cables(heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 Sqmm 3.5 core including taking out old U/s 16sqmm x 4core cable complete all as specified and as directed by Engr-in-charge.
S&F as in Replacement of DB DD TPN 415 Volts 04 ways double door vertical type load line DB fixed on MCCB complete all as specified and as directed by Engr-in-charge. Note : MCCB Paid Seperately.
S&F DB DD SPN 415 Volts 4 ways double door load line DB fixed complete all as specified and as directed by Engr-in-charge.
S&F DB DD SPN 415 Volts 12 ways double door load line DB fixed complete all as specified and as directed by Engr-in-charge.
S&F MCB, SP, Breaking capacity min 10KA,'C' curve 230V, 6 to 32 Amps complete all as specified and as directed by Engr-in-charge.
S&F MCB, SPN, Breaking capacity min 10KA,'C' curve 230V, 6 to 32 Amps complete all as specified and directed by Engr-in-charge.
S&F replacement of MCCB 3 Pole, 415 V, fixed type, 100 Amps with breaking capacity 16 KA complete all as specified and directed by Engr-in-charge.
M&L for recess/ surface mounting LED flat panel 2'X2' light fitting, fabricated out of CRCA sheet steel housing duly powder coated with high efficient LEDs & glare free full opal diffuser, IP20 complete with all accessories internally pre-wired and including conneting up with three core twisted flexible copper conductor cable with suitable size complete all as specified and as directed by Engr-in-charge. Make: Halonix, CAT No: HLFPR22-02-36 CW-R or equivalent of Bajaj/Philips/CG)
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with split unit air conditioner electric driven, single phase of capacity of 2.0 TR, BEE 5 star rated Inverter type, Copper piping should be length covered upto 5 Mtr as per site requirement,Copper Condenser,out door stand to be fixed on Out door unit and connecting accessories and testing Complete all as specified and as directed by Engr In Charge.Catalogue No SAC_245V_ADZ(R32) white and equiavalent makes Make Voltas/LG/Daiken
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 140 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA complete all as specified and as directed by Engineer-in-charge.
S&F sheet metal enclosure for 220 Volts 20 Amps with a three pin and earth plug top with socket and one single pole MCB 20 Amps complete as well as specified and as directed.
M&L for sand cushioning to under ground cable provided with layer of sand (8cm deep before laying the cable and 15 cm deep after laying the cable ie total 23 cm and punned down to 18cm complete all as specified and as directed by Engr-in-charge.
M&L for brick laid in trenches for cable protection of burnt clay sub class ‘B’ complete laid dry flat complete all as specified and as directed by Engr-in-charge.
Supply and laying and testing cable XLPE Insulated, Screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables(heavy duty) 1100 Volts grade with stranded aluminium coductor of size 10 sqmm 2 core complete all as specified and as directed by Engineer-in-charge.
S&F in Highly efficient LED Street light made of pressure die cast aluminium housing with high power LEDs capacity 25W Protection IP -66 complete all as specified and as directed by Engineer-in-charge.
S&F GI Brackets for street light made out of 32mm dia GI Pipe medium grade 1.2 Mtr length bend in shape as required with MS flat iron clamp,nut bolts, washer etc for fixing of LED Street light fitting 25 watt,IP -66 complete all as specified and as directed by Engineer-in-charge.
S&F GI Tubing medium grade of size 40mm bore for LT cable protection complete all as specified and as directed by Engineer-in-charge.
Excavation of Concrete of any description and in any position not otherwise specifically provided complete all as specified and as directed by Engineer-in-charge.
M&L for PCC 1:2:4 type B2 using 20mm grade stone aggregate as in making good of disturbed surface complete all as specified and as directed by Engineer-in-charge.
Labour only for shifting of split type AC 1.5 to 2.0 Tr from it’s existing location, by carefully disconnecting all electrical connections and taking out the holding frame and shifting the same to store for further accounting and making good to surface to match the original all as specified and as directed.
S&F DB DD TPN 415 Volts 08 ways double door vertical type including taking down old DB complete all as specified and as directed by Engr-in-charge.
Taking down copper/aluminium submain wiring complete, including conduits of any kind, and removing materials to store for keeping in safe custody or for taking credit (credit for the above items shall be made as per conditions seperately) and making good disturbed surfaces of walls. floors, etc. complete all as specified and as directed by Engr-in-charge.
Taking down ceiling fan/ Exhaust fan/ Wall mounting fan by carefully disconnecting all electrical connections and taking out for relocation and Hanging only ceiling fan/ fixing wall mounting fan and connecting up including provision 1.0Sqmm, 3 core pvc insulated FRLSH, cable from ceiling rose or connector to fanall complete all as specified and as directed by Engr-in-charge.
M&L for fan step regulator, modular, 120 W-2 module complete all as specified and as directed by Engr-in-charge.
S&F MCCB 125 Amps, 3P, 16KA. complete all as specified and as directed by Engr-in-charge.
M&L for Earthing with GI earthing plate electrode 60 cm x 60 cm x6 mm buried directly in ground (earth pit not less than 2.25 mtr deep being ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level, connecting to a galvanised earth lead wire 4 mm dia by means of bolts, nut check nut and washers protected with and including 15 mm dia medium grade GI pipe, necessary excavation and earth work, charcoal and common salt filling, watering arrangement with 20 mm GI pipe medium grade including PCC pit with pre cast RCC (1:2:4) cover, GI funnel with test point, testing and commissioning all as specified and directed as per EP No. 3 of SSR Part-I (2009)
Supply & Fix Air termination, single pointed, copper rod 12mm dia and 300mm long complete all as specified and as directed by Engr-in-charge.
M&L for Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and as directed by Engr-in-charge.
Supply & Fix Copper strip 20 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and as directed by Engr-in-charge.
Supply & Fix Copper strip 32 x 6mm buried in ground complete all as specified and as directed by Engr-in-charge.
M&L for providing Chemical Earthing with copper earth plate 900mm x600mm x5mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc complete with alternate layer of salt crystal and charcoal and Magnesium sulphate crystal as specified below:- (a) The earth pit should be of minimum 12 ft depth and 4 ft width. (b) The copper plate should be of 3 ft x 2ft and 5mm thick. (c) The copper strip should be of 32mmx6mm dimensions (cross section) up to 7.5 mtr. (d) The quantity used should be:- (i) Charcoal - 250 Kg (ii) Salt crystal - 200 Kg (iii) Magnesium sulphate crystal - 100 Kg (e) 3/4 inch dia GI pipe of enough length to reach just above copper plate fitted with funnel, meshed along with cap and running water should be provided for keping the soil wet approx one mtr GI pipe be kept out side for connection of running water. (f) The pit shall be constructed in PCC 1:2:4 type B1 using (using 20mm grage stone aggregate) RCC slab shall be provided in RCC 1:2:4 type B-1 (using 20mm grade stone aggregate) 50 mm thick pit cover reinforced with 8mm dia TMT bars 75mm c/o both ways MS handle 12mm dia, PGI funnel wire mesh and GI watering pipe of 20mm bore (light grade) and earth lead protection pipe 50 mm bore (light grade) shall be including the item.
M&L for (Set of 4 electrodes) Chemical/GEM/GEL Earthing system with earth electrode of for copper bonded low carbon steel core of 3 meter long having outer dia 80mm & inner dia 50mm duly filled with highly conductive and anti corrosive compound of required quantity with chemical composition Bentonite 40%, Copper sulphate 10%, Gypsom 5%, Graphite 10%, Alum 5%, Zinc sulphate 10%, Aluminium sulphate 10%, buried directly in ground ( 150-175 mm dia digging or auguring of earth to the required depth as specified by manufacturer and directed ) and pit filled up with GEL form of Electrolytic and Moisture retention type Earthing tested for less than 0.50 ohm Resistivity and connected with copper strip (32x6mm) to rod connected by means Given Terminal point with copper Nut Bolts, provision of ready made polymer chamber with cover, including necessary excavation in any type of soil, returning filling in, removal of surplus soil complete all as specified and as directed. (Makes: Pittas, RPG,HSL Industries, Roksna, Furse). Notes: Earthing system shall be designed so as to achieve test result less than 1 Ohms depending upon the soil conditions for the minimum 5 Years under warranty with 35% Increment in Ohmic value only with same soil resistivity.
Supply and fixing of wireless smoke detector including testing complete all as specified, Wireless-9Volt DC, Smoke sensor -Temp range-(10-70) Degree centigrade, Humidity range -20% to 95% RH, colour White Model No - AP SD -900 complete all as specified and directed by Engr-in-Charge. Make : Agni Protection /Qutak
Supply and fixing of Hooster radio meter Operating Voltage 15 volts DC, Indication-alrarm 85 db, Model No -AP RE-920 complete all as specified and directed by Engr-in-Charge. Make : Agni Protection /Qutak
Supply and fixing of MCP Remote Key including testing Colour Black with battery, complete all as specified and directed by Engr-in-Charge. Model No AP MCP-910 Make : Agni Protection /Qutak
Supply and fixing of 999 smoke detector wireless control panel , wireless receiving distance 1-3 KM complete all as specified and directed by Engr-in-Charge. Make : Agni Protection /Qutak
S&F of AC stand suitable for out door AC unit up to cap of upto 2 ton capacity complete all as specified and directed by Engr-in-Charge.
S&F Galvanised Steel Water Tubing 25mm Bore (dia), ‘Medium Grade’ with all ISI marked Fittings, fixed on Walls, Ceiling or laid in Floors or any other Situation complete all as specified and as directed.
S&F Gun metal gate valve 25mm dia with iron wheel head screwed both end complete all as specified and as directed.
S&F MCB, SPN, Breaking capacity min 10KA,'C' curve 230V, 40 Amps complete all as specified and directed by Engr-in-charge.
S&F MCB, SPN, Breaking capacity min 10KA,'C' curve 230V, 60 Amps complete all as specified and directed by Engr-in-charge.
S&F exhaust fan, single phase, 230V, 300mm sweep with louvers including fixing bolts etc complete all as specified and directed by Engr-in-charge.
Supply only self ballasted LED retrofit bulbs with PBT body shell and PVC diffuser AELIUS LX LED LAMP 14 WATT BC 6500K pre-wired and including conneting up with three core twisted flexible copper conductor cable with suitable size complete all as specified and as directed by Engr-in-charge. Make: CAT No: LLPO101029 Make Crompton or equivalent of Bajaj/Philips).
Note The amount of Rs 35,520/- against Schedule of Credit on Page No 152 shall be deducted from the total amount quoted against Sch 'A' while deriving the Contract Sum for Acceptance
M/S Parshant Associates
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .