Tender Value
₹34.3 L
Closing Date
24 Aug 2021, 3:00 pmClosed
Executive Engineer
E.E. (CD-IV), Room no. MZ-132
Name of work- A/R and M/O Buildings in Residential Area in East and West Campus at IIT Delhi. Sub head- Providing and Laying water proofing treatment at terrace of Amaltas (Main Guest House) and House No. 42 of Taxila Apartment Block- II
2021_IIT_641645_1
IITD/WORKS(SP-3563)/202
Open Tender
Civil Works
Works
90 days
IIT Delhi, Hauz Khas, New Delhi
As per tender document
5 documents required · 5 mandatory
₹0
15 Sept 2021
3 Aug 2021
25 Aug 2021
3 Aug 2021
24 Aug 2021
3 Aug 2021
Amount
Removal of existing waterproofing treatment from the terrace and shifting all debris at ground level (Except for removal of mud phuska).
Cleaning the surface from dirt or dust, loose particles by wire brushing the surface including repairing the cracks with cement mortar modified with SBR Latex including repairing of khurras and area of application at all horizontal and vertical area at all widths and depths.
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar1:3 (1 cement : 3 fine sand) as per standard design :
Supply and application of Blended acrylic based two component liquid applied materials to form 1.2 mm Dry Film Thickness (DFT) Membrane with a total consumption @ approx. 2.1 kg/m2 with a steel trowel. After first Coat of application, immediately apply the alkaline resistant non-woven reinforcing filament fibre mesh over the entire surface, thoroughly adhered to the laying surface with a trowel by vigorously spatulating on the reinforcing mesh, this will allow two component liquid applied material to impregnate the reinforcing mesh from the substrate upward, Apply second coat of two component liquid applied material on the Mesh. The formation of bubbles in the material during the drying process can occur when the amount of product applied to the installation substrate was not enough to fully impregnate the reinforcing mesh from the bottom up. The laying support is not perfectly smooth and exhibits some small depressions. Coating to be terminated on vertical wall 300 mm above the waterproofing level through parapet wall. The material shall be of following approved make- CICO/FOSROC/PIDILITE/ECMAS/ASIAN.
Post laying of waterproofing system, providing and laying protection screed of 75mm (average) thick screed of 1:2:4 admixed with crystalline admixture in slope. Curing the same for minimum 7 days.
KLA Construction Tech.Pvt.Ltd.
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .