| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.8 LAccepted-Finance | L1 | Accepted-Finance Accepted |
| Sl No | Description | Qty | Unit | PRIYABRATA LENKA L1 |
|---|---|---|---|---|
| 2.00Sub-Head :Concrete Work | ||||
| 3.00Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc., up to floor five level, excluding the cost of centering, shuttering and finishing : | ||||
| 3.01 | 1:2:4 (1 Cement : 2 coarse sand derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) | 2 | One Cubic Metre | 8,000 ₹16,000 Lowest |
| 4.00Sub-Head : Reinforced Concrete Work | ||||
| 5.00Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: | ||||
| 5.01 | Cement mortar 1:6 (1 cement : 6 coarse sand) | 0.2 | One Cubic Metre | 7,000 ₹1,400 Lowest |
| 6.00Sub-Head : Roofing | ||||
| 7.00Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, | ||||
| 7.01Single socketed pipes. | ||||
| 7.02 | 110 mm diameter | 200 | One Running Metre | 350 ₹70,000 Lowest |
Tender Value
₹2.9 L
EMD Value
₹5,710
Closing Date
3 Mar 2025, 3:00 pmClosed
Nodal Officer (Tender)
OFFICE OF THE CHIEF ENGINEER (CIVIL), BSNL CIVIL ODISHA ZONE, 3rd FLOOR, DOOR SANCHAR BHAWAN, BHUBANESWAR
Repair and replacement of damaged water supply and waste water or Rain water pipe line at external face of toilet shaft at Back side of DSB at Link Road under Cuttack BA
2025_BSNL_227553_1
75/CE(C)/2024-25/BCD/Cuttack
Open Tender
Civil Works
Item Rate
20 days
Cuttack
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
Yes
Accounts Officer (Cash) BSNL O/oPGMTD Cuttack
₹5,710
Yes
25 Sept 2025
20 Feb 2025
4 Mar 2025
20 Feb 2025
3 Mar 2025
20 Feb 2025
20 Feb 2025 - 3 Mar 2025
Amount
Sub-Head :Concrete Work
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc., up to floor five level, excluding the cost of centering, shuttering and finishing :
1:2:4 (1 Cement : 2 coarse sand derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
Sub-Head : Reinforced Concrete Work
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:
Cement mortar 1:6 (1 cement : 6 coarse sand)
Sub-Head : Roofing
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,
Single socketed pipes.
110 mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion.
Single pushfit Coupler :
Single tee with door
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hardwood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.
Sub-Head : Finishing
Finishing walls with Acrylic Smooth exterior paint of required shade :
New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm)
Sub-Head : Repairs to Buildings
Repair to plaster of thickness 12mm to 20 mm in patches of area 2.5 sqm and under, including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymer modified self curing mortar, including disposal of rubbish, all complete as per the direction of Engineer-In- Charge.
Disconnecting damaged overhead/terrace PVC water storage tank of any size from water supply line and removing from the terrace including shifting at ground level as per direction of Engineer-in- charge.
Dismantling 15 to 40 mm dia G.I. pipe including stacking of dismantled pipes (within 50 metres lead) as per direction of Engineerin-Charge.
(a) Internal Work- Exposed on wall
Sub-Head : Dismantling and Demolishing
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.
Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
Dismantling C.I. , PVC or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead :
100 mm dia pipe
Sub-Head : Water Supply
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall
32 mm nominal outer dia. Pipes.
40 mm nominal outer dia. Pipes.
50 mm nominal outer dia. Pipes.
Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.l. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design:
With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour.
25mm nominal bore. Weighing not less than 62 gms.
Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement :2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof.
Sub-Head : MARKET RATED ITEMS
Credit for
a) Unserviceable G.I.pipe
Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour.
40mm nominal bore.
50mm nominal bore.
Providing and fixing CPVC Union in CPVC pipe including cutting the pipe etc complete as per direction of Engineer-in-charge.
(a) 40 mm diametre
(b) 50 mm diametre
Providing and fixing CPVC Ball valve with handle in CPVC pipe line etc complete of approved quality:
(a) 40 mm diametre
(b) 50 mm diametre
Providing and fixing CPVC brass FTA in CPVC pipe including cutting the pipe etc complete as per direction of Engineer-in-charge. .
(a) 40 mm Diametre
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC soil, waste and vent pipes conforming to IS : 13592, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
Vent Cowl
110mm dia.
Providing and fixing double scaffolding system on the exterior side upto seven storey height made with best quality bamboo ballies 1.5 m centre to centre, horizontal and vertical ballies joining with best quality coir ropes, 38 mm thick local hard wood planks for working platform and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc complete as per direction of Engineer-in-charge. The elevational area of the scaffolding shall be measured for payment. The payment will be made once irrespective of duration of scaffolding.
Engaging labour for miscellaneous works such as cleaning of floors, wall tiles and sanitary fitting with Acid all complete as per direction of Engineer-in-charge.
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .