Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹153.2 CrAdmitted-Finance | ₹153.2 Cr | L1 | Admitted-Finance |
| 2 | L2₹178.6 CrAdmitted-Finance | ₹178.6 Cr | L2 | Admitted-Finance |
| 3 | L3₹217.8 CrAdmitted-Finance | ₹217.8 Cr | L3 | Admitted-Finance |
| 4 | L4₹229.3 CrAdmitted-Finance | ₹229.3 Cr | L4 | Admitted-Finance |
| 5 | Not Admitted-Fee | - | - | Not Admitted-Fee Fee not received |
| Sl No | Description | Qty | Unit | India Commercial Services L3 | Naolin Infrastructure Private Limited L2 | AARVANSS BUILDWELL AND INFRACON LLP L4 | Hitesh Electricals L1 |
|---|---|---|---|---|---|---|---|
| 1.00(D) Segregation of 11 KV Agriculture Feeders | |||||||
| 2.00D-(1) 11 KV over head Line 3 phase of F.S. | |||||||
| 3.00 | Supply of PCC Poles 9 mtrs (200 Kg) | 4,165 | No. | 3,566 ₹1.8 Cr | 2,400 ₹1.2 Cr | 3,903.1 ₹2.0 Cr | 2,350 ₹1.2 Cr |
| 4.00 | Supply of overhead steel cored aluminum ACSR WEASEL [30 sq.mm (6+1)/(2.59+2.59) mm ]conductor. | 757.05 | Km | 34,500 ₹3.1 Cr | 26,724 ₹2.4 Cr | 33,563.7 ₹3.0 Cr | 23,500 ₹2.1 Cr |
| 5.00 | Supply of 11 KV V Cross arm with top hamper & clamps (galvanized as per IS), 0.2 m long made of MS Channel 100x50x6 mm, MS Angle 65x65x6 mm & MS flat of size 50x6 mm weight(12.789 Kg.) Approx. | 3,675 | Set | 1,437 ₹63.3 L | 1,023.12 ₹44.4 L | 1,125.4 ₹49.3 L | 933 ₹40.6 L |
| 6.00Supply of Galvanized Stay set of 1.8 m long, 16 mm diameter solid GS stay rod & 300x300x4 mm anchor plate including, 2 Nos. 50x8 m Stay clamp, 1 nos. HT stay guy insulator, nut bolts, 2 Nos. turn buckles & 7/3.15 mm dia GI stranded wire etc. | |||||||
| 6.10 | Stay Set | 2,450 | No. | 869.4 ₹25.5 L | 850 ₹24.6 L | 2,028.9 ₹59.4 L | 630 ₹18.3 L |
| 6.20 | Strain/Guy Insulator | 2,450 | No. | 34.5 ₹1.0 L | 36 ₹1.1 L | 32.2 ₹93,957.50 | 20 ₹58,022.37 |
| 6.30 | Stay Wire 7/10 mm size (1 set = 5.508 Kg) | 2,450 | Set | 584 ₹17.1 L | 468.18 ₹13.6 L | 472.9 ₹13.8 L | 402 ₹11.7 L |
| 6.40 | Stay Clamps (Set = 2 Nos. Clamps) ( 1.7 Kgs. Approx) | 2,450 | Set | 192 ₹5.6 L | 136 ₹4.0 L | 321.2 ₹9.4 L | 124 ₹3.6 L |
Tender Value
₹84.1 Cr
EMD Value
₹1.7 Cr
Closing Date
19 Dec 2022, 5:00 pmClosed
SE(Project) AVVNL, Ajmer
Room No. 311 Vidhyut Bhawan, Makarwali Road, Panchsheel Nagar, Ajmer
DEVELOPMENT OF DISTRIBUTION INFRASTRUCTURE AT Rajsamand Circle of Ajmer Discom of Rajasthan State under REVAMPED REFORMS-BASED AND RESULTS-LINKED, DISTRIBUTION SECTOR SCHEME (RDSS)
2022_AVVNL_302613_1
AVVNL/RDSS/RSD/TN-104
Open Tender
Electrical Works
810 days
SE(Project) AVVNL
As per tender document
6 documents required · 6 mandatory
₹29,500
Senior Accounts Officer, EA and Cash, AVVNL, Ajme
₹1.7 Cr
Yes
9 Feb 2023
22 Oct 2022
21 Dec 2022
22 Oct 2022
19 Dec 2022
12 Nov 2022
22 Oct 2022 - 4 Nov 2022
Amount
(D) Segregation of 11 KV Agriculture Feeders
D-(1) 11 KV over head Line 3 phase of F.S.
Supply of PCC Poles 9 mtrs (200 Kg)
Supply of overhead steel cored aluminum ACSR WEASEL [30 sq.mm (6+1)/(2.59+2.59) mm ]conductor.
Supply of 11 KV V Cross arm with top hamper & clamps (galvanized as per IS), 0.2 m long made of MS Channel 100x50x6 mm, MS Angle 65x65x6 mm & MS flat of size 50x6 mm weight(12.789 Kg.) Approx.
Supply of Galvanized Stay set of 1.8 m long, 16 mm diameter solid GS stay rod & 300x300x4 mm anchor plate including, 2 Nos. 50x8 m Stay clamp, 1 nos. HT stay guy insulator, nut bolts, 2 Nos. turn buckles & 7/3.15 mm dia GI stranded wire etc.
Stay Set
Strain/Guy Insulator
Stay Wire 7/10 mm size (1 set = 5.508 Kg)
Stay Clamps (Set = 2 Nos. Clamps) ( 1.7 Kgs. Approx)
Supply of 11 KV double pole line structure set for cut point complete on existing poles in all respect with clamp, nut & bolts as requried made from M.S.Channel 100 x 50x6 , M.S.Angle 65 x 65 x 6 mm, M.S.Angle 50 x 50 x 6 mm and M.S.Flat 50 x 6 mm ( 101.383 Kg. Approx.) (Galvanized as per IS)
Supply of earthing rod sets for 11KV lines made with MS Rod (Galvanized) 20 mm dia, 3 meter length alongwith GI wire 8 SWG (approx.) total length / weight, 17 meter / 1.64 Kg.) as per latest specification and drawing adopted & approved by NIGAM.
Supply of 11 KV Polymer Composite Pin Insulator with pin
Supply of Composite Polymer Disc insulators for 11 KV 45 KN “T&C” type
Supply of 11KV T & C Type 45 KN Hardware
Supply of PG clamps (Weasel to Weasel)
Supply of 8 SWG (4 mm dia) GI wire for continuous earthing of 11 KV Line hot dip (Galvanized)
Supply of 11 KV Danger plate of size 200 X 250 mm complete in all respect
Supply of Guarding brackets ( 1 set = 2 Nos.) per span of 11 KV made of M.S. Angle 65X65X6 mm with clamps made of Flat 50x6, using Eye Hook 300X16 mm (75% Thread with Nut of Suitable Size) (galvanized)
M.S. Angle (2x1.83 M),65X65X6mm, 10.614X2=21.228 Kg (Approx) (1set= 2 Nos)
Clamp of M S Flat 50x6 mm using Eye Hook 300X16 mm (75% Thread with Nut of Suitable Size) (1set= 2 Nos) (2.218*2= 4.436 Approx)
G I Wire 8 SWG,68 Mtr, 6.66 Kg
Supply of M.S. Nuts & Bolts (Galvanized) of assorted size
D-(2) 11 KV over head Line 1 phase of F.S.
Supply of PCC Poles 9 mtrs (200 Kg)
Supply of overhead steel cored aluminum ACSR WEASEL [30 sq.mm (6+1)/(2.59+2.59) mm ]conductor.
Supply of 11KV top hamper (galvanized as per IS), made of MS Channel 100x50x6 mm weight(2.822 Kg.) Approx.
Supply of Galvanized Stay set of 1.8 m long, 16 mm diameter solid GS stay rod & 300x300x4 mm anchor plate including, 2 Nos. 50x8 m Stay clamp, 1 nos. HT stay guy insulator, nut bolts, 2 Nos. turn buckles & 7/3.15 mm dia GI stranded wire etc.
Stay Set
Strain/Guy Insulator
Stay Wire 7/10 mm size (1 set = 5.508 Kg)
Stay Clamps (Set = 2 Nos. Clamps) ( 1.7 Kgs. Approx)
Supply of earthing rod sets for 11KV lines made with MS Rod (Galvanized) 20 mm dia, 3 meter length alongwith GI wire 8 SWG (approx.) total length / weight, 17 meter / 1.64 Kg.) as per latest specification and drawing adopted & approved by NIGAM.
Supply of 11 KV Polymer Composite Pin Insulator with pin
Supply of Composite Polymer Disc insulators for 11 KV 45 KN “T&C” type
Supply of 11KV T & C Type 45 KN Hardware
Supply of LT Porcelain Pin Insulators
Supply of LT pins
Supply of LT Porcelain Shackle Insulators
Supply of LT Shackle hardware
Supply of PG clamps (Weasel to Weasel)
Supply of 8 SWG (4 mm dia) GI wire for continuous earthing of 11 KV Line hot dip (Galvanized)
Supply of 11 KV Danger plate of size 200 X 250 mm complete in all respect
Supply of LT cross arm with clamp(Galvanized as per IS) 600mm long made of MS Angle 50x50x6mm & MS Flat 50x6 mm on the existing pole/joist complete. Weight(3.150 Kg+ 1.083 Kg=4.233) Approx.
Supply of Guarding brackets ( 1 set = 2 Nos.) per span of 11 KV made of M.S. Angle 65X65X6 mm with clamps made of Flat 50x6, using Eye Hook 300X16 mm (75% Thread with Nut of Suitable Size) (galvanized)
M.S. Angle (2x1.83 M),65X65X6mm, 10.614X2=21.228 Kg (Approx) (1set= 2 Nos)
Clamp of M S Flat 50x6 mm using Eye Hook 300X16 mm (75% Thread with Nut of Suitable Size) (1set= 2 Nos) (2.218*2= 4.436 Approx)
G I Wire 8 SWG,68 Mtr, 6.66 Kg
Supply of 11 KV channel bracket with clamp (galvanized as per IS) for Dead end points 1130 mm long, made of 75x40x6 mm & MS Flat 50x6 mm size. Weight (8.06 Kg+1.93 Kg) Approx.
Supply of 11 KV angle bracket with clamp (galvanized as per IS) for T-OFF point 1130 mm long made of MS Angle 65x65x6 mm & MS Flat 50x6 mm size. Weight (6.554 Kg+1.145 Kg) Approx.
Supply of M.S. Nuts & Bolts (Galvanized) of assorted size
D-(3) 11 KV Bay Extension of F.S.
Supply of PCC Poles 9 mtrs (400 KG)
Supply of outdoor 11 KV 630 Amp.O/D VCB KIOSK complete with accessories including use of special tools & conducting all pre commissioning tests before energisation, filling oil etc. complete in all respect with erection& grouting of structure
Supply of 11 KV Polymer Composite Pin Insulator with pin
Supply of 45 KN. porcelain disc.insulators for 11 KV (each unit consisting of 2 disc insulators & one B&S Type hardware) including all acessories etc.
Supply of overhead steel cored aluminum ACSR Dog conductor
Supply of PG Clamps for Dog Conductor
Supply of earthing rod sets for 11KV lines made with MS Rod (Galvanized) 20 mm dia, 3 meter length alongwith GI wire 8 SWG (approx.) total length / weight, 17 meter / 1.64 Kg.)
Supply of horn gap sets including hardware nut & bolt & washer etc. - 11KV ( with 6 x 24 KV Post Insulator ) 1 Set=3 Nos
Supply of Sub-station type (9 KV 10 KA Station class) (1 set=1 No.) lightening arrestors on the existing brackets in all respect as required including hardware, nut , bolt & washers etc. For O&M works INCLUDING CONNECTION WITH EARTH BY 6 SWG GI WIRE AS REQUIRED AND JUMPERING ETC., IN SEPARATE EARTH PIT
Supply of 11KV with ( 9 x 24 KV Post Insulator) 400 Amp. Double break without EB GO Isolator switch set (Air Break) (consisting of 3 limbs) including nut & bolts etc.
Supply of 11 KV Danger plate of size 200 X 250 mm complete in all respect
Supply of metering points on 11 KV outgoing feeder at 33/11 KV S/S.
Supply of 11KV CT PT Set(200/5 Amp.)
Supply of MIP meter box having dimension 1100x625x375 mm fabricated out of 1.6 mm thick MS sheet and MS Angle size 25x25x3 mm. The test terminal block(TTB) link type shall be provided by contractor in the meter box.
Supply of 11 KV Bay Channel Size of 75x40x6 [ 6 nos of 3750 mm ( Total size 22.5 mtr. = 6x3.75mtr) & 2 nos of 3400mm (Total size 6.8 mtr. = 2 x 3.4mtr.)] & 100x50x6 [6 nos of 3750 mm (Total size 22.5 mtr. = 6 x 3.75 mtr)] Approx Weight 424.30 Kgs.[(22.5mtr.+6.8mtr.) x 7.14 Kgs. Per mtr = 209.20 kgs.) + (22.5 mtr. x 9.56 kgs. per mtr. = 215.1 kgs.)
Supply of M.S. Nuts & Bolts (Galvanized) of assorted size
D-(4) 11 KV UG Cable for Highway/Road/Railway crossing of F.S.
Supply of 11 KV XLPE Insulated Armoured Cable size of 3CoreX185 Sq. mm.
Supply of Cable End Termination Kit/ST Joint, Making Outdoor/ Indoor Joint For11 kV.
XLPE 3X185 SQ.MM H.S. ON OUTDOOR TYPE
XLPE 3X185 SQ.MM H.S.S.T. JOINT
Supply of earthing rod sets for 11KV lines made with MS Rod (Galvanized) 20 mm dia, 3 meter length alongwith GI wire 8 SWG (approx.) total length / weight, 17 meter / 1.64 Kg.)
Supply of Clamp of M S Flat 50x6 mm(2x0.501m, wt. 2.36 Kg. Approx)
(E) Additional HT Lines including Bifurcation of 11 KV Feeders
E-(1) 11 KV over head Line 3 phase for bifurcation of feeders & interconnection of new33/11 KV GSS
Supply of PCC Poles 9 mtrs (200 Kg)
Supply of overhead steel cored aluminum ACSR WEASEL [30 sq.mm (6+1)/(2.59+2.59) mm ]conductor.
Supply of11 KV V Cross arm with top hamper & clamps (galvanized as per IS), 0.2 m long made of MS Channel 100x50x6 mm, MS Angle 65x65x6 mm & MS flat of size 50x6 mm weight(12.789 Kg.) Approx.
Supply of Galvanized Stay set of 1.8 m long, 16 mm diameter solid GS stay rod & 300x300x4 mm anchor plate including, 2 Nos. 50x8 m Stay clamp, 1 nos. HT stay guy insulator, nut bolts, 2 Nos. turn buckles & 7/3.15 mm dia GI stranded wire etc.
Stay Set
Strain/Guy Insulator
Stay Wire 7/10 mm size (1 set = 5.508 Kg)
Stay Clamps (Set = 2 Nos. Clamps) ( 1.7 Kgs. Approx)
Supply of 11 KV double pole line structure set for cut point complete on existing poles in all respect with clamp, nut & bolts as requried made from M.S.Channel 100 x 50x6 , M.S.Angle 65 x 65 x 6 mm, M.S.Angle 50 x 50 x 6 mm and M.S.Flat 50 x 6 mm ( 101.383 Kg. Approx.) (Galvanized as per IS)
Supply of earthing rod sets for 11KV lines made with MS Rod (Galvanized) 20 mm dia, 3 meter length alongwith GI wire 8 SWG (approx.) total length / weight, 17 meter / 1.64 Kg.)
Supply of 11 KV Polymer Composite Pin Insulator with pin
Supply of Composite Polymer Disc insulators for 11 KV 45 KN “T&C” type
Supply of 11KV T & C Type 45 KN Hardware
Supply of PG clamps (Weasel to Weasel)
Supply of 8 SWG (4 mm dia) GI wire for continuous earthing of 11 KV Line hot dip (Galvanized)
Supply of 11 KV Danger plate of size 200 X 250 mm complete in all respect
Supply of Guarding brackets ( 1 set = 2 Nos.) per span of 11 KV made of M.S. Angle 65X65X6 mm with clamps made of Flat 50x6, using Eye Hook 300X16 mm (75% Thread with Nut of Suitable Size) (galvanized)
M.S. Angle (2x1.83 M),65X65X6mm, 10.614X2=21.228 Kg (Approx) (1set= 2 Nos)
Clamp of M S Flat 50x6 mm using Eye Hook 300X16 mm (75% Thread with Nut of Suitable Size) (1set= 2 Nos) (2.218*2= 4.436 Approx)
G I Wire 8 SWG,68 Mtr, 6.66 Kg
Supply of M.S. Nuts & Bolts (Galvanized) of assorted size
E-(2) 11 KV Bay Extension for feeder bifurcation
Supply of PCC Poles 9 mtrs (400 KG)
Supply of outdoor 11 KV 630 Amp.O/D VCB KIOSK complete with accessories including use of special tools & conducting all pre commissioning tests before energisation, filling oil etc. complete in all respect with erection& grouting of structure
Supply of 11 KV Polymer Composite Pin Insulator with pin
Supply of 45 KN. porcelain disc.insulators for 11 KV (each unit consisting of 2 disc insulators & one B&S Type hardware) including all acessories etc.
Supply of overhead steel cored aluminum ACSR Dog conductor in all respect.
Supply of PG Clamps for Dog Conductor
Supply of earthing rod sets for 11KV lines made with MS Rod (Galvanized) 20 mm dia, 3 meter length alongwith GI wire 8 SWG (approx.) total length / weight, 17 meter / 1.64 Kg.)
Supply of horn gap sets including hardware nut & bolt & washer etc. - 11KV ( with 6 x 24 KV Post Insulator ) 1 Set=3 Nos
Supply of Sub-station type (9 KV 10 KA Station class) (1 set=1 No.) lightening arrestors including hardware, nut , bolt & washers etc.
Supply of 11KV with ( 9 x 24 KV Post Insulator) 400 Amp. Double break without EB GO Isolator switch set (Air Break) (consisting of 3 limbs) including nut & bolts etc.
Supply of 11 KV Danger plate of size 200 X 250 mm complete in all respect
Supply of metering points on 11 KV outgoing feeder at 33/11 KV S/S.
Supply of 11KV CT PT Set(200/5 Amp.)
Supply of MIP meter box having dimension 1100x625x375 mm fabricated out of 1.6 mm thick MS sheet and MS Angle size 25x25x3 mm. The test terminal block(TTB) link type shall be provided by contractor in the meter box.
Supply of 11 KV Bay Channel Size of 75x40x6 [ 6 nos of 3750 mm ( Total size 22.5 mtr. = 6x3.75mtr) & 2 nos of 3400mm (Total size 6.8 mtr. = 2 x 3.4mtr.)] & 100x50x6 [6 nos of 3750 mm (Total size 22.5 mtr. = 6 x 3.75 mtr)] Approx Weight 424.30 Kgs.[(22.5mtr.+6.8mtr.) x 7.14 Kgs. Per mtr = 209.20 kgs.) + (22.5 mtr. x 9.56 kgs. per mtr. = 215.1 kgs.)
Supply of M.S. Nuts & Bolts (Galvanized) of assorted size
E-(3) 11 KV UG Cable for Highway/Road/Railway crossing for feeder bifurcation & new 33/11 KV GSS 11 KV feeders interconnection
Supply of 11 KV XLPE Insulated Armoured Cable size of 3CoreX185 Sq. mm.
Supply of Cable End Termination Kit/ST Joint, Making Outdoor/ Indoor Joint For11 kV
XLPE 3X185 SQ.MM H.S. ON OUTDOOR TYPE
XLPE 3X185 SQ.MM H.S.S.T. JOINT
Supply of earthing rod sets for 11KV lines made with MS Rod (Galvanized) 20 mm dia, 3 meter length alongwith GI wire 8 SWG (approx.) total length / weight, 17 meter / 1.64 Kg.)
Supply of Clamp of M S Flat 50x6 mm(2x0.501m, wt. 2.36 Kg. Approx)
(F) HVDS
F-(1) 11 KV over head Line 3 phase of HVDS
Supply of PCC Poles 9 mtrs (200 Kg)
Supply of overhead steel cored aluminum ACSR WEASEL [30 sq.mm (6+1)/(2.59+2.59) mm ]conductor.
Supply of 11 KV V Cross arm with top hamper & clamps (galvanized as per IS), 0.2 m long made of MS Channel 100x50x6 mm, MS Angle 65x65x6 mm & MS flat of size 50x6 mm weight(12.789 Kg.) Approx.
Supply of Galvanized Stay set of 1.8 m long, 16 mm diameter solid GS stay rod & 300x300x4 mm anchor plate including, 2 Nos. 50x8 m Stay clamp, 1 nos. HT stay guy insulator, nut bolts, 2 Nos. turn buckles & 7/3.15 mm dia GI stranded wire etc.
Stay Set
Strain/Guy Insulator
Stay Wire 7/10 mm size (1 set = 5.508 Kg)
Stay Clamps (Set = 2 Nos. Clamps) ( 1.7 Kgs. Approx)
Supply of 11 KV double pole line structure set for cut point complete on existing poles in all respect with clamp, nut & bolts as requried made from M.S.Channel 100 x 50x6 , M.S.Angle 65 x 65 x 6 mm, M.S.Angle 50 x 50 x 6 mm and M.S.Flat 50 x 6 mm ( 101.383 Kg. Approx.) (Galvanized as per IS)
Supply of earthing rod sets for 11KV lines made with MS Rod (Galvanized) 20 mm dia, 3 meter length alongwith GI wire 8 SWG (approx.) total length / weight, 17 meter / 1.64 Kg.)
Supply of 11 KV Polymer Composite Pin Insulator with pin
Supply of Composite Polymer Disc insulators for 11 KV 45 KN “T&C” type
Supply of 11KV T & C Type 45 KN Hardware
Supply of PG clamps (Weasel to Weasel)
Supply of 8 SWG (4 mm dia) GI wire for continuous earthing of 11 KV Line hot dip (Galvanized)
Supply of 11 KV Danger plate of size 200 X 250 mm complete in all respect
Supply of Guarding brackets ( 1 set = 2 Nos.) per span of 11 KV made of M.S. Angle 65X65X6 mm with clamps made of Flat 50x6, using Eye Hook 300X16 mm (75% Thread with Nut of Suitable Size) (galvanized)
M.S. Angle (2x1.83 M),65X65X6mm, 10.614X2=21.228 Kg (Approx) (1set= 2 Nos)
Clamp of M S Flat 50x6 mm using Eye Hook 300X16 mm (75% Thread with Nut of Suitable Size) (1set= 2 Nos) (2.218*2= 4.436 Approx)
G I Wire 8 SWG,68 Mtr, 6.66 Kg
Supply of M.S. Nuts & Bolts (Galvanized) of assorted size
F-(2) 11 KV over head Line 1 phase of HVDS
Supply of PCC Poles 9 mtrs (200 Kg)
Supply of overhead steel cored aluminum ACSR WEASEL [30 sq.mm (6+1)/(2.59+2.59) mm ]conductor.
Supply of 11KV top hamper (galvanized as per IS), made of MS Channel 100x50x6 mm weight(2.822 Kg.) Approx.
Supply of Galvanized Stay set of 1.8 m long, 16 mm diameter solid GS stay rod & 300x300x4 mm anchor plate including, 2 Nos. 50x8 m Stay clamp, 1 nos. HT stay guy insulator, nut bolts, 2 Nos. turn buckles & 7/3.15 mm dia GI stranded wire etc.
Stay Set
Strain/Guy Insulator
Stay Wire 7/10 mm size (1 set = 5.508 Kg)
Stay Clamps (Set = 2 Nos. Clamps) ( 1.7 Kgs. Approx)
Supply of earthing rod sets for 11KV lines made with MS Rod (Galvanized) 20 mm dia, 3 meter length alongwith GI wire 8 SWG (approx.) total length / weight, 17 meter / 1.64 Kg.)
Supply of 11 KV Polymer Composite Pin Insulator with pin
Supply of Composite Polymer Disc insulators for 11 KV 45 KN “T&C” type
Supply of 11KV T & C Type 45 KN Hardware
Supply of LT Porcelain Pin Insulators
Supply of LT pins.
Supply of LT Porcelain Shackle Insulators
Supply of LT Shackle hardware
Supply of PG clamps (Weasel to Weasel)
Supply of 8 SWG (4 mm dia) GI wire (Galvanized)
Supply of 11 KV Danger plate of size 200 X 250 mm complete in all respect
Supply of LT cross arm with clamp(Galvanized as per IS) 600mm long made of MS Angle 50x50x6mm & MS Flat 50x6 mm on the existing pole/joist complete. Weight(3.150 Kg+ 1.083 Kg) Approx.
Supply of Guarding brackets ( 1 set = 2 Nos.) per span of 11 KV made of M.S. Angle 65X65X6 mm with clamps made of Flat 50x6, using Eye Hook 300X16 mm (75% Thread with Nut of Suitable Size) (galvanized)
M.S. Angle (2x1.83 M),65X65X6mm, 10.614X2=21.228 Kg (Approx) (1set= 2 Nos)
Clamp of M S Flat 50x6 mm using Eye Hook 300X16 mm (75% Thread with Nut of Suitable Size) (1set= 2 Nos) (2.218*2= 4.436 Approx)
G I Wire 8 SWG,68 Mtr, 6.66 Kg
Supply of 11 KV channel bracket with clamp (galvanized as per IS) for Dead end points 1130 mm long, made of 75x40x6 mm & MS Flat 50x6 mm size. Weight (8.06 Kg+1.93 Kg) Approx.
Supply of 11 KV angle bracket with clamp (galvanized as per IS) for T-OFF point 1130 mm long made of MS Angle 65x65x6 mm & MS Flat 50x6 mm size. Weight (6.554 Kg+1.145 Kg) Approx.
Supply of M.S. Nuts & Bolts (Galvanized) of assorted size
F-(3) DISTRIBUTION TRANSFORMER THREE PHASE (25 KVA, 40 KVA , 63 KVA, 100 KVA and 160 KVA) of HVDS
Supply of PCC Poles 9 mtrs (400 KG)
Supply of 11 /0.4 KV 100 KVA Al wound conventional outdoor type distribution transformers
Supply of 11 /0.4 KV 63 KVA Al wound conventional outdoor type distribution transformers
Supply of overhead ABC(Aerial bunched cable) 1Cx25+1x25 sqmm.
Supply of overhead steel cored aluminum ACSR WEASEL [30 sq.mm (6+1)/(2.59+2.59) mm ]conductor.
Supply of 11/0.4 KV SubStation structure set (Galvanized) on existing poles in all respect with clamps as required made from M.S. channel 100x50 X6 mm, 75x40x6 mm, M.S. angle 75x75x6 mm, and M.S. flat 50x6 mm weight(166.746 kgs.) Approx
Supply of horn gap sets including hardware nut & bolt & washer etc. ( with 6 x 24 KV Post Insulator ) 1 Set=3 Nos
Supply of set of 3 nos. of earthing rod sets for S/S made with MS Rod (Galvanized) 20 mm dia, 3 meter length alongwith GI wire 8 SWG (approx. total length / weight, 50 m / 4.907 Kg.)
Supply of 11KV ( with 9 x 12 KV Post Insulator ) 400 Amp. GO double break without EB Isolator including hardware etc.
Supply of Galvanized Stay set of 1.8 m long, 16 mm diameter solid GS stay rod & 300x300x4 mm anchor plate including, 2 Nos. 50x8 m Stay clamp, 1 nos. HT stay guy insulator, nut bolts, 2 Nos. turn buckles & 7/3.15 mm dia GI stranded wire etc.
Stay Set
Strain/Guy Insulator
Stay Wire 7/10 mm size (1 set = 5.508 Kg)
Stay Clamps (Set = 2 Nos. Clamps) ( 1.7 Kgs. Approx)
Supply of 11 KV Polymer Composite Pin Insulator with pin
Supply of Composite Polymer Disc insulators for 11 KV 45 KN “T&C” type
Supply of 11KV T & C Type 45 KN Hardware
Supply of 11 KV Danger plate of size 200 X 250 mm complete in all respect
Supply of PG clamps (Weasel to Weasel)
Supply of M.S. Nuts & Bolts (Galvanized) of assorted size
F-(4) DISTRIBUTION TRANSFORMER SINGLE PHASE (25KVA, 16 KVA, 10 KVA and 5 KVA) of HVDS
Supply of PCC Poles 9 mtrs (400 KG)
Supply of 6.35KV/240 V 25 KVA aluminium wound, completely self protected distribution transformers
Supply of 6.35KV/240 V 16 KVA aluminium wound, completely self protected distribution transformers
Supply of 6.35KV/240 V 10 KVA aluminium wound, completely self protected distribution transformers
Supply of overhead ABC(Aerial bunched cable) 1Cx25+1x25 sqmm.
Supply of overhead steel cored aluminum ACSR WEASEL [30 sq.mm (6+1)/(2.59+2.59) mm ]conductor.
Supply of 6.35 / 0.24 KV substation structure for 10/16/25 KVA complete (galvanized as per IS) complete in all respect made of MS Channel, MS angle and MS flat etc., (36.054 kg approx.)
Supply of set of 3 nos. of earthing rod sets for S/S made with MS Rod (Galvanized) 20 mm dia, 3 meter length alongwith GI wire 8 SWG (approx. total length / weight, 50 m / 4.907 Kg.)
Supply of 11 KV 200 Amp. Drop out cum isolator with 3.0 Amp. fuse & 12 KV post insulators including nut, bolt & washers.
Supply of Galvanized Stay set of 1.8 m long, 16 mm diameter solid GS stay rod & 300x300x4 mm anchor plate including, 2 Nos. 50x8 m Stay clamp, 1 nos. HT stay guy insulator, nut bolts, 2 Nos. turn buckles & 7/3.15 mm dia GI stranded wire etc.
Stay Set
Strain/Guy Insulator
Stay Wire 7/10 mm size (1 set = 5.508 Kg)
Stay Clamps (Set = 2 Nos. Clamps) ( 1.7 Kgs. Approx)
Supply of 11 KV Polymer Composite Pin Insulator with pin
Supply of Composite Polymer Disc insulators for 11 KV 45 KN “T&C” type
Supply of 11KV T & C Type 45 KN Hardware
Supply of 11 KV Danger plate of size 200 X 250 mm complete in all respect
Supply of PG clamps (Weasel to Weasel)
Supply of Distribution class (5 KA 9 KV Distribution class) lightening arrestors including hardware, nut , bolt & washers etc.
Supply of M.S. Nuts & Bolts (Galvanized) of assorted size
(G) Replacement of old frayed Conductors
G-(1) 11 kV Line : Augmentation/Reconductoring of Dog and Weasel
Supply of PCC Poles 9 mtrs (200 Kg)
Supply of 11 KV V Cross arm with top hamper & clamps (galvanized as per IS), 0.2 m long made of MS Channel 100x50x6 mm, MS Angle 65x65x6 mm & MS flat of size 50x6 mm weight(12.789 Kg.) Approx.
Supply of 11 KV Polymer Composite Pin Insulator with pin
Supply of Composite Polymer Disc insulators for 11 KV 45 KN “T&C” type
Supply of 11KV T & C Type 45 KN Hardware
Supply of overhead steel cored aluminum ACSR WEASEL [30 sq.mm (6+1)/(2.59+2.59) mm ]conductor.
Supply of PG clamps (Weasel to Weasel)
Supply of Galvanized Stay set of 1.8 m long, 16 mm diameter solid GS stay rod & 300x300x4 mm anchor plate including, 2 Nos. 50x8 m Stay clamp, 1 nos. HT stay guy insulator, nut bolts, 2 Nos. turn buckles & 7/3.15 mm dia GI stranded wire etc.
Stay Set
Strain/Guy Insulator
Stay Wire 7/10 mm size (1 set = 5.508 Kg)
Stay Clamps (Set = 2 Nos. Clamps) ( 1.7 Kgs. Approx)
Supply of 11 KV Danger plate of size 200 X 250 mm complete in all respect
Supply of M.S. Nuts & Bolts (Galvanized) of assorted size
G-(2) Replacement O/H L.T. line by LT INSULATED RABBIT CONDUCTOR
Supply of PCC Poles 9 mtrs (200 Kg)
Supply of LT Insulated Rabbit Conductor [50 sq mm (6 X 3.35 + 1 X 3.35) mm]
Supply of Galvanized Stay set of 1.8 m long, 16 mm diameter solid GS stay rod & 300x300x4 mm anchor plate including, 2 Nos. 50x8 m Stay clamp, 1 nos. HT stay guy insulator, nut bolts, 2 Nos. turn buckles & 7/3.15 mm dia GI stranded wire etc.
Stay Set
Strain/Guy Insulator
Stay Wire 7/10 mm size (1 set = 5.508 Kg)
Stay Clamps (Set = 2 Nos. Clamps) ( 1.7 Kgs. Approx)
Supply of LT cross arm with clamp(Galvanized as per IS) 600mm long made of MS Angle 50x50x6mm & MS Flat 50x6 mm on the existing pole/joist complete. Weight(3.150 Kg+ 1.083 Kg) Approx.
Supply of LT Porcelain Pin Insulators
Supply of LT pins
Supply of LT Porcelain Shackle Insulators
Supply of LT Shackle hardware
Supply of M.S. Nuts & Bolts (Galvanized) of assorted size
(H) Provision of AB Cable
H-(1) LT AB Cable Single Phase
Supply of PCC Poles 9 mtrs (200 Kg)
Supply of overhead ABC(Aerial bunched cable) 1Cx25+1x25 sqmm.
Supply of Galvanized Stay set of 1.8 m long, 16 mm diameter solid GS stay rod & 300x300x4 mm anchor plate including, 2 Nos. 50x8 m Stay clamp, 1 nos. HT stay guy insulator, nut bolts, 2 Nos. turn buckles & 7/3.15 mm dia GI stranded wire etc.
Stay Set
Strain/Guy Insulator
Stay Wire 7/10 mm size (1 set = 5.508 Kg)
Stay Clamps (Set = 2 Nos. Clamps) ( 1.7 Kgs. Approx)
Supply of suspension clamps with eye hook bolt and PCC Pole Clamps (NFC type) suitable for AB Cable Complete in all respect.
Supply of dead end clamp with eye hook bolt and PCC Pole Clamps (NFC type) suitable for AB Cable Complete in all respectt.
Supply of LT Insulation piercing connector (French standard) Type-A suitable for AB cable Complete in all respect.
Supply of Insulation piercing connector (French standard) Type-B suitable for AB cable Complete in all respect.
H-(2) LT AB Cable Three Phase
Supply of PCC Poles 9 mtrs (200 Kg)
Supply of overhead ABC(Aerial bunched cable) 3Cx25+1x25 sqmm.
Supply of Galvanized Stay set of 1.8 m long, 16 mm diameter solid GS stay rod & 300x300x4 mm anchor plate including, 2 Nos. 50x8 m Stay clamp, 1 nos. HT stay guy insulator, nut bolts, 2 Nos. turn buckles & 7/3.15 mm dia GI stranded wire etc.
Stay Set
Strain/Guy Insulator
Stay Wire 7/10 mm size (1 set = 5.508 Kg)
Stay Clamps (Set = 2 Nos. Clamps) ( 1.7 Kgs. Approx)
Supply of suspension clamps with eye hook bolt and PCC Pole Clamps (NFC type) suitable for AB Cable Complete in all respect.
Supply of dead end clamp with eye hook bolt and PCC Pole Clamps (NFC type) suitable for AB Cable Complete in all respectt.
Supply of LT Insulation piercing connector (French standard) Type-A suitable for AB cable Complete in all respect.
Supply of Insulation piercing connector (French standard) Type-B suitable for AB cable Complete in all respect.
H-(3) LT UNDERGROUND CABLE
Supply of LT XLPE INSULATED ARMOURED CABLE OF SIZE 4CX185 SQ.MM
SUPPLY OF LT SUPPLY DISTRIBUTION BOX & CHANGE OVER FOR WITHSTAND UNDERGROUND SERVICE LINE
LT Distribution piller Boxes of 400 Amps. Capacity.
LT distribution kiosk 200 Amp. suitable for distribution for Main Line & Service Connections
Supply of earthing rod sets for 11KV lines made with MS Rod (Galvanized) 20 mm dia, 3 meter length alongwith GI wire 8 SWG (approx.) total length / weight, 17 meter / 1.64 Kg.)
Supply of Cable termination / straight through joints on LT XLPE INSULATED ARMOURED CABLE OF SIZE 4CX185 SQ.MM with outdoor straight through joint
Supply of service line LT PVC Insulated and PVC Sheathed armoured underground cable
FOR SINGLE PH - 2CX4 SQ.MM
FOR THREE PH - 4CX16 SQ.MM
(I) 1-Phase & 3-Phase Armoured Service Line Cabling Work
Supply of ISI mark 2CX4 Sq.mm. 1100 Volt heavy duty armoured PVC XLPE Cable of Aluminium conductor conforming to IS:7098 (Part-I) (latest amended).
Supply of 4 in 1 Deepdrawn Meter Box with multiple outgoing connector.
Supply of 6 in 1 Deepdrawn Meter Box with multiple outgoing connector.
Supply of ISI mark 4CX16 Sq.mm. 1100 Volt heavy duty armoured PVC XLPE Cable of Aluminium conductor conforming to IS:7098 (Part-I) (latest amended).
(J) Electric Vehicle Charging Station Infra
J-(1) 11 KV over head line 3 Phase of EV Charging
Supply of PCC Poles 9 mtrs (200 Kg)
Supply of overhead steel cored aluminum ACSR Rabbit Conductor.
Supply of 11 KV V Cross arm with top hamper & clamps (galvanized as per IS), 0.2 m long made of MS Channel 100x50x6 mm, MS Angle 65x65x6 mm & MS flat of size 50x6 mm weight(12.789 Kg.) Approx.
Supply of Galvanized Stay set of 1.8 m long, 16 mm diameter solid GS stay rod & 300x300x4 mm anchor plate including, 2 Nos. 50x8 m Stay clamp, 1 nos. HT stay guy insulator, nut bolts, 2 Nos. turn buckles & 7/3.15 mm dia GI stranded wire etc
Stay Set
Strain/Guy Insulator
Stay Wire 7/10 mm size (1 set = 5.508 Kg)
Stay Clamps (Set = 2 Nos. Clamps) ( 1.7 Kgs. Approx)
Supply of 11 KV double pole line structure set for cut point complete on existing poles in all respect with clamp, nut & bolts as requried made from M.S.Channel 100 x 50x6 , M.S.Angle 65 x 65 x 6 mm, M.S.Angle 50 x 50 x 6 mm and M.S.Flat 50 x 6 mm ( 101.383 Kg. Approx.) (Galvanized as per IS)
Supply of earthing rod sets for 11KV lines made with MS Rod (Galvanized) 20 mm dia, 3 meter length alongwith GI wire 8 SWG (approx.) total length / weight, 17 meter / 1.64 Kg.)
Supply of 11 KV Polymer Composite Pin Insulator with pin
Supply of Composite Polymer Disc insulators for 11 KV 45 KN “T&C” type
Supply of 11KV T & C Type 45 KN Hardware
Supply of PG clamps for rabbit
Supply of 8 SWG (4 mm dia) GI wire (Galvanized)
Supply of 11 KV Danger plate of size 200 X 250 mm complete in all respect
Supply of Guarding brackets ( 1 set = 2 Nos.) per span of 11 KV made of M.S. Angle 65X65X6 mm with clamps made of Flat 50x6, using Eye Hook 300X16 mm (75% Thread with Nut of Suitable Size) (galvanized)
M.S. Angle (2x1.83 M),65X65X6mm, 10.614X2=21.228 Kg (Approx) (1set= 2 Nos)
Clamp of M S Flat 50x6 mm using Eye Hook 300X16 mm (75% Thread with Nut of Suitable Size) (1set= 2 Nos) (2.218*2= 4.436 Approx)
G I Wire 8 SWG,68 Mtr, 6.66 Kg
Supply of M.S. Nuts & Bolts (Galvanized) of assorted size
J-(2)11 KV under ground cable of EV Charging
Supply of 11 KV XLPE Insulated Armoured Cable size of 3CoreX185 Sq. mm.
Supply of Cable End Termination Kit/ST Joint, Making Outdoor/ Indoor Joint For11 kV
XLPE 3X185 SQ.MM H.S. ON OUTDOOR TYPE
XLPE 3X185 SQ.MM H.S.S.T. JOINT
Supply of earthing rod sets for 11KV lines made with MS Rod (Galvanized) 20 mm dia, 3 meter length alongwith GI wire 8 SWG (approx.) total length / weight, 17 meter / 1.64 Kg.)
Supply of Clamp of M S Flat 50x6 mm(2x0.501m, wt. 2.36 Kg. Approx)
J-(3) DISTRIBUTION TRANSFORMER THREE PHASE (100 KVA and 160 KVA) of EV Charging
Supply of PCC Poles 9 mtrs (400 KG)
Supply of 11 /0.4 KV 100 KVA Al wound conventional outdoor type distribution transformers
Supply of overhead ABC(Aerial bunched cable) 1Cx25+1x25 sqmm.
Supply of overhead steel cored aluminum ACSR WEASEL [30 sq.mm (6+1)/(2.59+2.59) mm ]conductor.
Supply of 11/0.4 KV SubStation structure set (Galvanized) on existing poles in all respect with clamps as required made from M.S. channel 100x50 X6 mm, 75x40x6 mm, M.S. angle 75x75x6 mm, and M.S. flat 50x6 mm weight(166.746 kgs.) Approx
Supply of horn gap sets including hardware nut & bolt & washer etc. ( with 6 x 24 KV Post Insulator ) 1 Set=3 Nos
Supply of set of 3 nos. of earthing rod sets for S/S made with MS Rod (Galvanized) 20 mm dia, 3 meter length alongwith GI wire 8 SWG (approx. total length / weight, 50 m / 4.907 Kg.) as per latest specification and drawing adopted & approved by NIGAM.
Supply of 11KV ( with 9 x 12 KV Post Insulator ) 400 Amp. GO double break without EB Isolator including hardware etc.
Supply of Galvanized Stay set of 1.8 m long, 16 mm diameter solid GS stay rod & 300x300x4 mm anchor plate including, 2 Nos. 50x8 m Stay clamp, 1 nos. HT stay guy insulator, nut bolts, 2 Nos. turn buckles & 7/3.15 mm dia GI stranded wire etc.,
Stay Set
Strain/Guy Insulator
Stay Wire 7/10 mm size (1 set = 5.508 Kg)
Stay Clamps (Set = 2 Nos. Clamps) ( 1.7 Kgs. Approx)
Supply of 11 KV Polymer Composite Pin Insulator with pin
Supply of Composite Polymer Disc insulators for 11 KV 45 KN “T&C” type
Supply of 11KV T & C Type 45 KN Hardware
Supply of 11 KV Danger plate of size 200 X 250 mm complete in all respect
Supply of PG clamps (Weasel to Weasel)
Supply of M.S. Nuts & Bolts (Galvanized) of assorted size
Description of Work / Item(s)
Amount
(D) Segregation of 11 KV Agriculture Feeders
D-(1) 11 KV over head Line 3 phase of F.S.
Erection of PCC Poles in all types of soil & allignment including excavation of pit size 1.2x0.6x1.5 cum. for 9 mtrs (200 Kg) PCC poles in ground and back filling soil consolidating each deposit layer of 0.15 mtr. by watering and ramming etc. in the length.
In normal soil
In ordinary rock/Hard Soil which does not require drilling
In ordinary rock/Hard Soil which require drilling
Drawing of overhead steel cored aluminum ACSR WEASEL [30 sq.mm (6+1)/(2.59+2.59) mm ]conductor.
Fixing of 11 KV V Cross arm with top hamper & clamps (galvanized as per IS), 0.2 m long made of MS Channel 100x50x6 mm, MS Angle 65x65x6 mm & MS flat of size 50x6 mm weight(12.789 Kg.) Approx.
Fixing of Galvanized Stay set of 1.8 m long, 16 mm diameter solid GS stay rod & 300x300x4 mm anchor plate including, 2 Nos. 50x8 m Stay clamp, 1 nos. HT stay guy insulator, nut bolts, 2 Nos. turn buckles & 7/3.15 mm dia GI stranded wire etc., as required as per technical specification, approved drawings and scope of work.
In normal soil
In ordinary rock/Hard Soil which does not require drilling
In ordinary rock/Hard Soil which require drilling
Fixing of 11 KV double pole line structure set for cut point complete on existing poles in all respect with clamp, nut & bolts as requried made from M.S.Channel 100 x 50x6 , M.S.Angle 65 x 65 x 6 mm, M.S.Angle 50 x 50 x 6 mm and M.S.Flat 50 x 6 mm ( 101.383 Kg. Approx.) (Galvanized as per IS)
Fixing of earthing rod sets for 11KV lines made with MS Rod (Galvanized) 20 mm dia, 3 meter length alongwith GI wire 8 SWG (approx.) total length / weight, 17 meter / 1.64 Kg.) as per latest specification and drawing adopted & approved by NIGAM.
Fixing of 11 KV Polymer Composite Pin Insulator with pin on pole complete in all respect
Fixing of Composite Polymer Disc insulators with hardware for 11 KV 45 KN “T&C” type (as per latest specification and drawings adopted and approved by NIGAM)
Fixing of PG clamps (Weasel to Weasel) made of aluminum alloy as per IS:617-1994 . All ferrous metal part intended for outdoor use except those made of stainless steel shall be protected by hot dip galvanizing in accordance with IS 2633-1986(latest amended)
Erection of 8 SWG (4 mm dia) GI wire for continuous earthing of 11 KV Line hot dip (Galvanized)
Erection of 11 KV Danger plate of size 200 X 250 mm complete in all respect
Erection of Guarding brackets ( 1 set = 2 Nos.) per span of 11 KV made of M.S. Angle 65X65X6 mm with clamps made of Flat 50x6, using Eye Hook 300X16 mm (75% Thread with Nut of Suitable Size) (galvanized)
Erection of M.S. Nuts & Bolts (Galvanized) of assorted size
D-(2) 11 KV over head Line 1 phase of F.S.
Erection of PCC Poles in all types of soil & allignment including excavation of pit size 1.2x0.6x1.5 cum. for 9 mtrs (200 Kg) PCC poles in ground and back filling soil consolidating each deposit layer of 0.15 mtr. by watering and ramming etc. in the length.
In normal soil
In ordinary rock/Hard Soil which does not require drilling
In ordinary rock/Hard Soil which require drilling
Drawing of overhead steel cored aluminum ACSR WEASEL [30 sq.mm (6+1)/(2.59+2.59) mm ]conductor.
Fixing of 11KV top hamper (galvanized as per IS), made of MS Channel 100x50x6 mm weight(2.822 Kg.) Approx.
Fixing of Galvanized Stay set of 1.8 m long, 16 mm diameter solid GS stay rod & 300x300x4 mm anchor plate including, 2 Nos. 50x8 m Stay clamp, 1 nos. HT stay guy insulator, nut bolts, 2 Nos. turn buckles & 7/3.15 mm dia GI stranded wire etc., as required as per technical specification, approved drawings and scope of work.
In normal soil
In ordinary rock/Hard Soil which does not require drilling
In ordinary rock/Hard Soil which require drilling
Fixing of earthing rod sets for 11KV lines made with MS Rod (Galvanized) 20 mm dia, 3 meter length alongwith GI wire 8 SWG (approx.) total length / weight, 17 meter / 1.64 Kg.) as per latest specification and drawing adopted & approved by NIGAM.
Fixing of 11 KV Polymer Composite Pin Insulator with pin on pole complete in all respect
Fixing of Composite Polymer Disc insulators with hardware for 11 KV 45 KN “T&C” type (as per latest specification and drawings adopted and approved by NIGAM)
Fixing of LT Porcelain Pin Insulators with pin (as per latest specification and drawings adopted & aprpoved by the NIGAM).
Fixing of LT Porcelain Shackle Insulators with hardware as per latest specification and drawings adopted & approved by the NIGAM.
Fixing of PG clamps (Weasel to Weasel) made of aluminum alloy as per IS:617-1994 . All ferrous metal part intended for outdoor use except those made of stainless steel shall be protected by hot dip galvanizing in accordance with IS 2633-1986(latest amended)
Erection of 8 SWG (4 mm dia) GI wire for continuous earthing of 11 KV Line hot dip (Galvanized)
Erection of 11 KV Danger plate of size 200 X 250 mm complete in all respect
Erection of LT cross arm with clamp(Galvanized as per IS) 600mm long made of MS Angle 50x50x6mm & MS Flat 50x6 mm on the existing pole/joist complete. Weight(3.150 Kg+ 1.083 Kg=4.233) Approx.
Erection of Guarding brackets ( 1 set = 2 Nos.) per span of 11 KV made of M.S. Angle 65X65X6 mm with clamps made of Flat 50x6, using Eye Hook 300X16 mm (75% Thread with Nut of Suitable Size) (galvanized)
Erection of 11 KV channel bracket with clamp (galvanized as per IS) for Dead end points 1130 mm long, made of 75x40x6 mm & MS Flat 50x6 mm size. Weight (8.06 Kg+1.93 Kg) Approx.
Erection of 11 KV angle bracket with clamp (galvanized as per IS) for T-OFF point 1130 mm long made of MS Angle 65x65x6 mm & MS Flat 50x6 mm size. Weight (6.554 Kg+1.145 Kg) Approx.
Erection of M.S. Nuts & Bolts (Galvanized) of assorted size
D-(3) 11 KV Bay Extension of F.S.
Erection of PCC Poles in all types of soil & allignment including excavation of pit size 1.2x0.6x1.5 cum. for 9 mtrs (400 KG) and 1.2x0.6x1.35 cum PCC poles in ground and back filling soil consolidating each deposit layer of 0.15 mtr. by watering and ramming etc. in the length.
In normal soil
In ordinary rock/Hard Soil which does not require drilling
In ordinary rock/Hard Soil which require drilling
Erection of outdoor 11 KV 630 Amp.O/D VCB KIOSK complete with accessories including use of special tools & conducting all pre commissioning tests before energisation, filling oil etc. complete in all respect with erection& grouting of structure (Including civil works). Constn. of 11 KV VCB Kiosk Plate form 3.0 x 1.5 x 1.5 Mtrs. Including excavation in all type of soil up to the depth of 900 mm, foundation concrete in C.C. - 1 : 5 :10 for 150 mm thickness, brick masonary in cement mortar of mix. 1:8 with top of the plate form finished with 100 mm layer of C.C. 1:2:4 including fixing of foundation bolts and cement plaster - 20 mm thick of mix ratio 1:6, on all the exposed surfaces of the plate form - complete in all respect.
Fixing of 11 KV Polymer Composite Pin Insulator with pin on pole complete in all respect
Fixing of 45 KN. porcelain disc.insulators for 11 KV (each unit consisting of 2 disc insulators & one B&S Type hardware) on brackets complete including all acessories etc.
Erection of overhead steel cored aluminum ACSR Dog conductor in all respect.
Fixing of PG Clamps for Dog Conductor
Fixing of earthing rod sets for 11KV lines made with MS Rod (Galvanized) 20 mm dia, 3 meter length alongwith GI wire 8 SWG (approx.) total length / weight, 17 meter / 1.64 Kg.) as per latest specification and drawing adopted & approved by NIGAM.
Fixing of horn gap sets on existing brackets in all respect as required including hardware nut & bolt & washer etc. - 11KV ( with 6 x 24 KV Post Insulator ) 1 Set=3 Nos
Fixing of Sub-station type (9 KV 10 KA Station class) (1 set=1 No.) lightening arrestors on the existing brackets in all respect as required including hardware, nut , bolt & washers etc. For O&M works INCLUDING CONNECTION WITH EARTH BY 6 SWG GI WIRE AS REQUIRED AND JUMPERING ETC., IN SEPARATE EARTH PIT
Assembly, installation & commissioning of 11KV with ( 9 x 24 KV Post Insulator) 400 Amp. Double break without EB GO Isolator switch set (Air Break) (consisting of 3 limbs) on erected structure with setting of accurate operation including fixing of allied accessories in all respect and jumpering on both ends with suitable clamps for connection with the system including nut & bolts etc.
Erection of 11 KV Danger plate of size 200 X 250 mm complete in all respect
Installation of metering points on 11 KV outgoing feeder at 33/11 KV S/S.The installation work to be carried out as per drawing/design,under the supervision of concern Assistant Engineer
Mounting structure (Galvanized)
The requisite steel members will be supplied by contractor including the hardware.Contractor shall joint/weld the members to form the mounting structure as per drawing.Necessary tools,welding ,machines,lifting devics etc. shall be arranged by contractor. Structure Should be made of MS Angle 50x50x6mm, 45x45x5 mm and MS Chennel 100x50x6 mm(Approx Weight 147.88 Kg)
Civil works
Erection of lattices in alignment including excavation and concreting of structure foundation including cement, sand and grit 20 mm size (crusher broken) having ratio 1:3:6 and grit 40 mm size for ratio 1:5:10 and curing for period as required (21 days). Area of concreting will be as per the drawing.
Installation of Metering equipments:
Installation 11KV CT PT Set(200/5 Amp.)
Installation MIP meter box having dimension 1100x625x375 mm fabricated out of 1.6 mm thick MS sheet and MS Angle size 25x25x3 mm. The meter box will be fixed firmly with sufficient strength at a place as per drawing. The test terminal block(TTB) link type shall be provided by contractor in the meter box.
The required cables from CTPT set to meter box laid down in 50 mm GI pipe with suitable bends & nipples, shall be provided by contractor alongwith the consumable items such as PVC tapes, petroleum jelly etc. The cable should be PVC multi strand copper 4 core 2.5/4 Sq. mm ISI marked and firm & tight connections shall be made by suitable connector e.g. at CTPT sets by using clamps and at meter/TTB by suitable lugs etc. The CTPT sets so installed shall be earthed by means of the MS Flat (size 50x6 mm) by joining it with the nearest earthing available at the sub-station. Requisite earthing material shall be made available by the contractor.
Erection of 11 KV Bay Channel Size of 75x40x6 [ 6 nos of 3750 mm ( Total size 22.5 mtr. = 6x3.75mtr) & 2 nos of 3400mm (Total size 6.8 mtr. = 2 x 3.4mtr.)] & 100x50x6 [6 nos of 3750 mm (Total size 22.5 mtr. = 6 x 3.75 mtr)] Approx Weight 424.30 Kgs.[(22.5mtr.+6.8mtr.) x 7.14 Kgs. Per mtr = 209.20 kgs.) + (22.5 mtr. x 9.56 kgs. per mtr. = 215.1 kgs.)
Erection of M.S. Nuts & Bolts (Galvanized) of assorted size
D-(4) 11 KV UG Cable for Highway/Road/Railway crossing of F.S.
Laying of two (Double circuit) 11KV, XLPE (Aluminium conductor) undrground cables of SIZE 3X185 SQ.MM w/o overlapping as per relevant IS/ AVVNL standard including excavation of 50 cm width x 120 cm deep trench in Kaccha land.25 cm thick under layer of sand. 'A' class bricks or concrete block covering refilling soil in the remaining portion and providing/fixing cable route indicators at every 30Mtr.of cable and at every turn.
LAYING IN BRICKS AS PER STANDARD (Kachha road)
LAYING IN BRICKS AS PER STANDARD (Pakka road)
LAYING IN DWC PIPE OF DIA.200 MM FOR CABLE at Road crossing or wherever it is required.
Laying of Single circuit (S/C) 11 KV XLPE 3CX185 sqmm cable without Road cutting i.e. through burrowing machine "VERMIER".(120 cm deep).Use of this technology must be restricted to the situation
Fixing of Cable End Termination Kit/ST Joint, Making Outdoor/ Indoor Joint For11 kV Aluminum Conductor XLPE Armoured HT Cable With Outdoor And Terminal End Preparation Of Joint As Per Manufactures Kit Guidance And Direction Including Preparation Of Cable End & Testing etc.
XLPE 3X185 SQ.MM H.S. ON OUTDOOR TYPE
XLPE 3X185 SQ.MM H.S.S.T. JOINT
Fixing of earthing rod sets for 11KV lines made with MS Rod (Galvanized) 20 mm dia, 3 meter length alongwith GI wire 8 SWG (approx.) total length / weight, 17 meter / 1.64 Kg.) as per latest specification and drawing adopted & approved by NIGAM.
PROVIDING AND FIXING OF G.I. PIPE OF 125 MM DIAMETER, B-CLASS (IS:1239 MARK), AT THE STARTING AND FINISHING POINT OF 11 KV UNDER GROUND CABLES AND TO LAY & CLAMP VERTICALLY WITH THE EXISTING SUPPORT, INCLUDING LABOUR CHARGES.
Providing and laying of cement concrete in ratio 1:3:6 using 43 grade cement river sand and 12 mm to 20 mm graded blast crusher broken in pit/foundation according to the size/type of support/stay set including compacting/curing for 21 days in steel plates shuttering/farmer base.
Fixing of Clamp of M S Flat 50x6 mm(2x0.501m, wt. 2.36 Kg. Approx)
(E) Additional HT Lines including Bifurcation of 11 KV Feeders
E-(1) 11 KV over head Line 3 phase for bifurcation of feeders & interconnection of new33/11 KV GSS
Erection of PCC Poles in all types of soil & allignment including excavation of pit size 1.2x0.6x1.5 cum. for 9 mtrs (200 Kg) PCC poles in ground and back filling soil consolidating each deposit layer of 0.15 mtr. by watering and ramming etc. in the length.
In normal soil
In ordinary rock/Hard Soil which does not require drilling
In ordinary rock/Hard Soil which require drilling
Drawing of overhead steel cored aluminum ACSR WEASEL [30 sq.mm (6+1)/(2.59+2.59) mm ]conductor.
Fixing of11 KV V Cross arm with top hamper & clamps (galvanized as per IS), 0.2 m long made of MS Channel 100x50x6 mm, MS Angle 65x65x6 mm & MS flat of size 50x6 mm weight(12.789 Kg.) Approx.
Fixing of Galvanized Stay set of 1.8 m long, 16 mm diameter solid GS stay rod & 300x300x4 mm anchor plate including, 2 Nos. 50x8 m Stay clamp, 1 nos. HT stay guy insulator, nut bolts, 2 Nos. turn buckles & 7/3.15 mm dia GI stranded wire etc., as required as per technical specification, approved drawings and scope of work.
In normal soil
In ordinary rock/Hard Soil which does not require drilling
In ordinary rock/Hard Soil which require drilling
Fixing of 11 KV double pole line structure set for cut point complete on existing poles in all respect with clamp, nut & bolts as requried made from M.S.Channel 100 x 50x6 , M.S.Angle 65 x 65 x 6 mm, M.S.Angle 50 x 50 x 6 mm and M.S.Flat 50 x 6 mm ( 101.383 Kg. Approx.) (Galvanized as per IS)
Fixing of earthing rod sets for 11KV lines made with MS Rod (Galvanized) 20 mm dia, 3 meter length alongwith GI wire 8 SWG (approx.) total length / weight, 17 meter / 1.64 Kg.) as per latest specification and drawing adopted & approved by NIGAM.
Fixing of 11 KV Polymer Composite Pin Insulator with pin on pole complete in all respect
Fixing of Composite Polymer Disc insulators with hardware for 11 KV 45 KN “T&C” type (as per latest specification and drawings adopted and approved by NIGAM)
Fixing of PG clamps (Weasel to Weasel) made of aluminum alloy as per IS:617-1994 . All ferrous metal part intended for outdoor use except those made of stainless steel shall be protected by hot dip galvanizing in accordance with IS 2633-1986(latest amended)
Erection of 8 SWG (4 mm dia) GI wire for continuous earthing of 11 KV Line hot dip (Galvanized)
Erection of 11 KV Danger plate of size 200 X 250 mm complete in all respect
Erection of Guarding brackets ( 1 set = 2 Nos.) per span of 11 KV made of M.S. Angle 65X65X6 mm with clamps made of Flat 50x6, using Eye Hook 300X16 mm (75% Thread with Nut of Suitable Size) (galvanized)
Erection of M.S. Nuts & Bolts (Galvanized) of assorted size
E-(2) 11 KV Bay Extension for feeder bifurcation
Erection of PCC Poles in all types of soil & allignment including excavation of pit size 1.2x0.6x1.5 cum. for 9 mtrs (400 KG) and 1.2x0.6x1.35 cum PCC poles in ground and back filling soil consolidating each deposit layer of 0.15 mtr. by watering and ramming etc. in the length.
In normal soil
In ordinary rock/Hard Soil which does not require drilling
In ordinary rock/Hard Soil which require drilling
Erection of outdoor 11 KV 630 Amp.O/D VCB KIOSK complete with accessories including use of special tools & conducting all pre commissioning tests before energisation, filling oil etc. complete in all respect with erection& grouting of structure (Including civil works). Constn. of 11 KV VCB Kiosk Plate form 3.0 x 1.5 x 1.5 Mtrs. Including excavation in all type of soil up to the depth of 900 mm, foundation concrete in C.C. - 1 : 5 :10 for 150 mm thickness, brick masonary in cement mortar of mix. 1:8 with top of the plate form finished with 100 mm layer of C.C. 1:2:4 including fixing of foundation bolts and cement plaster - 20 mm thick of mix ratio 1:6, on all the exposed surfaces of the plate form - complete in all respect.
Fixing of 11 KV Polymer Composite Pin Insulator with pin on pole complete in all respect
Fixing of 45 KN. porcelain disc.insulators for 11 KV (each unit consisting of 2 disc insulators & one B&S Type hardware) on brackets complete including all acessories etc.
Erection of overhead steel cored aluminum ACSR Dog conductor in all respect.
Fixing of PG Clamps for Dog Conductor
Fixing of earthing rod sets for 11KV lines made with MS Rod (Galvanized) 20 mm dia, 3 meter length alongwith GI wire 8 SWG (approx.) total length / weight, 17 meter / 1.64 Kg.) as per latest specification and drawing adopted & approved by NIGAM.
Fixing of horn gap sets on existing brackets in all respect as required including hardware nut & bolt & washer etc. - 11KV ( with 6 x 24 KV Post Insulator ) 1 Set=3 Nos
Fixing of Sub-station type (9 KV 10 KA Station class) (1 set=1 No.) lightening arrestors on the existing brackets in all respect as required including hardware, nut , bolt & washers etc. For O&M works INCLUDING CONNECTION WITH EARTH BY 6 SWG GI WIRE AS REQUIRED AND JUMPERING ETC., IN SEPARATE EARTH PIT
Assembly, installation & commissioning of 11KV with ( 9 x 24 KV Post Insulator) 400 Amp. Double break without EB GO Isolator switch set (Air Break) (consisting of 3 limbs) on erected structure with setting of accurate operation including fixing of allied accessories in all respect and jumpering on both ends with suitable clamps for connection with the system including nut & bolts etc.
Erection of 11 KV Danger plate of size 200 X 250 mm complete in all respect
Installation of metering points on 11 KV outgoing feeder at 33/11 KV S/S.The installation work to be carried out as per drawing/design,under the supervision of concern Assistant Engineer
Mounting structure (Galvanized)
The requisite steel members will be supplied by contractor including the hardware.Contractor shall joint/weld the members to form the mounting structure as per drawing.Necessary tools,welding ,machines,lifting devics etc. shall be arranged by contractor. Structure Should be made of MS Angle 50x50x6mm, 45x45x5 mm and MS Chennel 100x50x6 mm(Approx Weight 147.88 Kg)
Civil works
Erection of lattices in alignment including excavation and concreting of structure foundation including cement, sand and grit 20 mm size (crusher broken) having ratio 1:3:6 and grit 40 mm size for ratio 1:5:10 and curing for period as required (21 days). Area of concreting will be as per the drawing.
Installation of Metering equipments:
Installation 11KV CT PT Set(200/5 Amp.)
Installation MIP meter box having dimension 1100x625x375 mm fabricated out of 1.6 mm thick MS sheet and MS Angle size 25x25x3 mm. The meter box will be fixed firmly with sufficient strength at a place as per drawing. The test terminal block(TTB) link type shall be provided by contractor in the meter box.
The required cables from CTPT set to meter box laid down in 50 mm GI pipe with suitable bends & nipples, shall be provided by contractor alongwith the consumable items such as PVC tapes, petroleum jelly etc. The cable should be PVC multi strand copper 4 core 2.5/4 Sq. mm ISI marked and firm & tight connections shall be made by suitable connector e.g. at CTPT sets by using clamps and at meter/TTB by suitable lugs etc. The CTPT sets so installed shall be earthed by means of the MS Flat (size 50x6 mm) by joining it with the nearest earthing available at the sub-station. Requisite earthing material shall be made available by the contractor.
Erection of 11 KV Bay Channel Size of 75x40x6 [ 6 nos of 3750 mm ( Total size 22.5 mtr. = 6x3.75mtr) & 2 nos of 3400mm (Total size 6.8 mtr. = 2 x 3.4mtr.)] & 100x50x6 [6 nos of 3750 mm (Total size 22.5 mtr. = 6 x 3.75 mtr)] Approx Weight 424.30 Kgs.[(22.5mtr.+6.8mtr.) x 7.14 Kgs. Per mtr = 209.20 kgs.) + (22.5 mtr. x 9.56 kgs. per mtr. = 215.1 kgs.)
Erection of M.S. Nuts & Bolts (Galvanized) of assorted size
E-(3) 11 KV UG Cable for Highway/Road/Railway crossing for feeder bifurcation & new 33/11 KV GSS 11 KV feeders interconnection
Laying of two (Double circuit) 11KV, XLPE (Aluminium conductor) undrground cables of SIZE 3X185 SQ.MM w/o overlapping as per relevant IS/ AVVNL standard including excavation of 50 cm width x 120 cm deep trench in Kaccha land.25 cm thick under layer of sand. 'A' class bricks or concrete block covering refilling soil in the remaining portion and providing/fixing cable route indicators at every 30Mtr.of cable and at every turn.
LAYING IN BRICKS AS PER STANDARD (Kachha road)
LAYING IN BRICKS AS PER STANDARD (Pakka road)
LAYING IN DWC PIPE OF DIA.200 MM FOR CABLE at Road crossing or wherever it is required.
Laying of Single circuit (S/C) 11 KV XLPE 3CX185 sqmm cable without Road cutting i.e. through burrowing machine "VERMIER".(120 cm deep).Use of this technology must be restricted to the situation like:-
Fixing of Cable End Termination Kit/ST Joint, Making Outdoor/ Indoor Joint For11 kV Aluminum Conductor XLPE Armoured HT Cable With Outdoor And Terminal End Preparation Of Joint As Per Manufactures Kit Guidance And Direction Including Preparation Of Cable End & Testing etc.
XLPE 3X185 SQ.MM H.S. ON OUTDOOR TYPE
XLPE 3X185 SQ.MM H.S.S.T. JOINT
Fixing of earthing rod sets for 11KV lines made with MS Rod (Galvanized) 20 mm dia, 3 meter length alongwith GI wire 8 SWG (approx.) total length / weight, 17 meter / 1.64 Kg.) as per latest specification and drawing adopted & approved by NIGAM.
PROVIDING AND FIXING OF G.I. PIPE OF 125 MM DIAMETER, B-CLASS (IS:1239 MARK), AT THE STARTING AND FINISHING POINT OF 11 KV UNDER GROUND CABLES AND TO LAY & CLAMP VERTICALLY WITH THE EXISTING SUPPORT, INCLUDING LABOUR CHARGES.
Providing and laying of cement concrete in ratio 1:3:6 using 43 grade cement river sand and 12 mm to 20 mm graded blast crusher broken in pit/foundation according to the size/type of support/stay set including compacting/curing for 21 days in steel plates shuttering/farmer base.
Fixing of Clamp of M S Flat 50x6 mm(2x0.501m, wt. 2.36 Kg. Approx)
(F) HVDS
F-(1) 11 KV over head Line 3 phase of HVDS
Erection of PCC Poles in all types of soil & allignment including excavation of pit size 1.2x0.6x1.5 cum. for 9 mtrs (200 Kg) PCC poles in ground and back filling soil consolidating each deposit layer of 0.15 mtr. by watering and ramming etc. in the length.
In normal soil
In ordinary rock/Hard Soil which does not require drilling
In ordinary rock/Hard Soil which require drilling
Drawing of overhead steel cored aluminum ACSR WEASEL [30 sq.mm (6+1)/(2.59+2.59) mm ]conductor.
Fixing of 11 KV V Cross arm with top hamper & clamps (galvanized as per IS), 0.2 m long made of MS Channel 100x50x6 mm, MS Angle 65x65x6 mm & MS flat of size 50x6 mm weight(12.789 Kg.) Approx.
Fixing of Galvanized Stay set of 1.8 m long, 16 mm diameter solid GS stay rod & 300x300x4 mm anchor plate including, 2 Nos. 50x8 m Stay clamp, 1 nos. HT stay guy insulator, nut bolts, 2 Nos. turn buckles & 7/3.15 mm dia GI stranded wire etc., as required as per technical specification, approved drawings and scope of work.
In normal soil
In ordinary rock/Hard Soil which does not require drilling
In ordinary rock/Hard Soil which require drilling
Fixing of 11 KV double pole line structure set for cut point complete on existing poles in all respect with clamp, nut & bolts as requried made from M.S.Channel 100 x 50x6 , M.S.Angle 65 x 65 x 6 mm, M.S.Angle 50 x 50 x 6 mm and M.S.Flat 50 x 6 mm ( 101.383 Kg. Approx.) (Galvanized as per IS)
Fixing of earthing rod sets for 11KV lines made with MS Rod (Galvanized) 20 mm dia, 3 meter length alongwith GI wire 8 SWG (approx.) total length / weight, 17 meter / 1.64 Kg.) as per latest specification and drawing adopted & approved by NIGAM.
Fixing of 11 KV Polymer Composite Pin Insulator with pin on pole complete in all respect
Fixing of Composite Polymer Disc insulators with hardware for 11 KV 45 KN “T&C” type (as per latest specification and drawings adopted and approved by NIGAM)
Fixing of PG clamps (Weasel to Weasel) made of aluminum alloy as per IS:617-1994 . All ferrous metal part intended for outdoor use except those made of stainless steel shall be protected by hot dip galvanizing in accordance with IS 2633-1986(latest amended)
Erection of 8 SWG (4 mm dia) GI wire for continuous earthing of 11 KV Line hot dip (Galvanized)
Erection of 11 KV Danger plate of size 200 X 250 mm complete in all respect
Erection of Guarding brackets ( 1 set = 2 Nos.) per span of 11 KV made of M.S. Angle 65X65X6 mm with clamps made of Flat 50x6, using Eye Hook 300X16 mm (75% Thread with Nut of Suitable Size) (galvanized)
Erection of M.S. Nuts & Bolts (Galvanized) of assorted size
F-(2) 11 KV over head Line 1 phase of HVDS
Erection of PCC Poles in all types of soil & allignment including excavation of pit size 1.2x0.6x1.5 cum. for 9 mtrs (200 Kg) PCC poles in ground and back filling soil consolidating each deposit layer of 0.15 mtr. by watering and ramming etc. in the length.
In normal soil
In ordinary rock/Hard Soil which does not require drilling
In ordinary rock/Hard Soil which require drilling
Drawing of overhead steel cored aluminum ACSR WEASEL [30 sq.mm (6+1)/(2.59+2.59) mm ]conductor.
Fixing of 11KV top hamper (galvanized as per IS), made of MS Channel 100x50x6 mm weight(2.822 Kg.) Approx.
Fixing of Galvanized Stay set of 1.8 m long, 16 mm diameter solid GS stay rod & 300x300x4 mm anchor plate including, 2 Nos. 50x8 m Stay clamp, 1 nos. HT stay guy insulator, nut bolts, 2 Nos. turn buckles & 7/3.15 mm dia GI stranded wire etc., as required as per technical specification, approved drawings and scope of work.
In normal soil
In ordinary rock/Hard Soil which does not require drilling
In ordinary rock/Hard Soil which require drilling
Fixing of earthing rod sets for 11KV lines made with MS Rod (Galvanized) 20 mm dia, 3 meter length alongwith GI wire 8 SWG (approx.) total length / weight, 17 meter / 1.64 Kg.) as per latest specification and drawing adopted & approved by NIGAM.
Fixing of 11 KV Polymer Composite Pin Insulator with pin on pole complete in all respect
Fixing of Composite Polymer Disc insulators with hardware for 11 KV 45 KN “T&C” type (as per latest specification and drawings adopted and approved by NIGAM)
Fixing of LT Porcelain Pin Insulators with pin (as per latest specification and drawings adopted & aprpoved by the NIGAM).
Fixing of LT Porcelain Shackle Insulators with hardware as per latest specification and drawings adopted & approved by the NIGAM.
Fixing of PG clamps (Weasel to Weasel) made of aluminum alloy as per IS:617-1994 . All ferrous metal part intended for outdoor use except those made of stainless steel shall be protected by hot dip galvanizing in accordance with IS 2633-1986(latest amended)
Erection of 8 SWG (4 mm dia) GI wire for continuous earthing of 11 KV Line hot dip (Galvanized)
Erection of 11 KV Danger plate of size 200 X 250 mm complete in all respect
Erection of LT cross arm with clamp(Galvanized as per IS) 600mm long made of MS Angle 50x50x6mm & MS Flat 50x6 mm on the existing pole/joist complete. Weight(3.150 Kg+ 1.083 Kg) Approx.
Erection of Guarding brackets ( 1 set = 2 Nos.) per span of 11 KV made of M.S. Angle 65X65X6 mm with clamps made of Flat 50x6, using Eye Hook 300X16 mm (75% Thread with Nut of Suitable Size) (galvanized)
Erection of 11 KV channel bracket with clamp (galvanized as per IS) for Dead end points 1130 mm long, made of 75x40x6 mm & MS Flat 50x6 mm size. Weight (8.06 Kg+1.93 Kg) Approx.
Erection of 11 KV angle bracket with clamp (galvanized as per IS) for T-OFF point 1130 mm long made of MS Angle 65x65x6 mm & MS Flat 50x6 mm size. Weight (6.554 Kg+1.145 Kg) Approx.
Erection of M.S. Nuts & Bolts (Galvanized) of assorted size
F-(3) DISTRIBUTION TRANSFORMER THREE PHASE (25 KVA, 40 KVA , 63 KVA, 100 KVA and 160 KVA) of HVDS
Erection of PCC Poles in all types of soil & allignment including excavation of pit size 1.2x0.6x1.5 cum. for 9 mtrs (400 KG) and 1.2x0.6x1.35 cum PCC poles in ground and back filling soil consolidating each deposit layer of 0.15 mtr. by watering and ramming etc. in the length.
In normal soil
In ordinary rock/Hard Soil which does not require drilling
ordinary rock / CC Road which require drilling
Installation of 11 /0.4 KV 100 KVA Al wound conventional outdoor type distribution transformers with all fittings and accessories and first filling of transformer oil alongwith MCCB. Protection on LV side confirming to technical specification
Installation of 11 /0.4 KV 63 KVA Al wound conventional outdoor type distribution transformers with all fittings and accessories and first filling of transformer oil alongwith MCCB. Protection on LV side confirming to technical specification
Laying of overhead ABC(Aerial bunched cable) 1Cx25+1x25 sqmm.
Drawing & Stringing of overhead steel cored aluminum ACSR WEASEL [30 sq.mm (6+1)/(2.59+2.59) mm ]conductor.
Fixing of 11/0.4 KV SubStation structure set (Galvanized) on existing poles in all respect with clamps as required made from M.S. channel 100x50 X6 mm, 75x40x6 mm, M.S. angle 75x75x6 mm, and M.S. flat 50x6 mm weight(166.746 kgs.) Approx
Fixing of horn gap sets on existing brackets in all respect as required including hardware nut & bolt & washer etc. ( with 6 x 24 KV Post Insulator ) 1 Set=3 Nos
Erection of set of 3 nos. of earthing rod sets for S/S made with MS Rod (Galvanized) 20 mm dia, 3 meter length alongwith GI wire 8 SWG (approx. total length / weight, 50 m / 4.907 Kg.) as per latest specification and drawing adopted & approved by NIGAM.
Fixing of 11KV ( with 9 x 12 KV Post Insulator ) 400 Amp. GO double break without EB Isolator on existing bracket complete in all respect as required including hardware etc.
Fixing of Galvanized Stay set of 1.8 m long, 16 mm diameter solid GS stay rod & 300x300x4 mm anchor plate including, 2 Nos. 50x8 m Stay clamp, 1 nos. HT stay guy insulator, nut bolts, 2 Nos. turn buckles & 7/3.15 mm dia GI stranded wire etc., as required as per technical specification, approved drawings and scope of work.
In normal soil
In ordinary rock/Hard Soil which does not require drilling
In ordinary rock/Hard Soil which require drilling
Fixing of 11 KV Polymer Composite Pin Insulator with pin on pole complete in all respect
Fixing of Composite Polymer Disc insulators with hardware for 11 KV 45 KN “T&C” type (as per latest specification and drawings adopted and approved by NIGAM)
Erection of 11 KV Danger plate of size 200 X 250 mm complete in all respect
Fixing of PG clamps (Weasel to Weasel) made of aluminum alloy as per IS:617-1994 . All ferrous metal part intended for outdoor use except those made of stainless steel shall be protected by hot dip galvanizing in accordance with IS 2633-1986(latest amended)
Erection of M.S. Nuts & Bolts (Galvanized) of assorted size
F-(4) DISTRIBUTION TRANSFORMER SINGLE PHASE (25KVA, 16 KVA, 10 KVA and 5 KVA) of HVDS
Erection of PCC Poles in all types of soil & allignment including excavation of pit size 1.2x0.6x1.5 cum. for 9 mtrs (400 KG) and 1.2x0.6x1.35 cum PCC poles in ground and back filling soil consolidating each deposit layer of 0.15 mtr. by watering and ramming etc. in the length.
In normal soil
In ordinary rock/Hard Soil which does not require drilling
In ordinary rock/Hard Soil which require drilling
Installation of 6.35KV/240 V 25 KVA aluminium wound, completely self protected distribution transformers with In-built Circuit Breakers with all fittings and accessories including set of bimetallic connectors for HV & LV bushings, Non-galvanized mounting arrangement duly fitted in each of transformer and first filling of transformer oil confirming to technical specification of tender and IS:1180 Part - 1/2014 with latest amendment
Installation of 6.35KV/240 V 16 KVA aluminium wound, completely self protected distribution transformers with In-built Circuit Breakers with all fittings and accessories including set of bimetallic connectors for HV & LV bushings, Non-galvanized mounting arrangement duly fitted in each of transformer and first filling of transformer oil confirming to technical specification of tender and IS:1180 Part - 1/2014 with latest amendment
Installation of 6.35KV/240 V 10 KVA aluminium wound, completely self protected distribution transformers with In-built Circuit Breakers with all fittings and accessories including set of bimetallic connectors for HV & LV bushings, Non-galvanized mounting arrangement duly fitted in each of transformer and first filling of transformer oil confirming to technical specification of tender and IS:1180 Part - 1/2014 with latest amendment
Laying of overhead ABC(Aerial bunched cable) 1Cx25+1x25 sqmm.
Drawing & Stringing of overhead steel cored aluminum ACSR WEASEL [30 sq.mm (6+1)/(2.59+2.59) mm ]conductor.
Erection of 6.35 / 0.24 KV substation structure for 10/16/25 KVA complete (galvanized as per IS) complete in all respect made of MS Channel, MS angle and MS flat etc., (as per latest specification and drawing adopted & approved by NIGAM) (36.054 kg approx.)
Erection of set of 3 nos. of earthing rod sets for S/S made with MS Rod (Galvanized) 20 mm dia, 3 meter length alongwith GI wire 8 SWG (approx. total length / weight, 50 m / 4.907 Kg.) as per latest specification and drawing adopted & approved by NIGAM.
Erection of 11 KV 200 Amp. Drop out cum isolator with 3.0 Amp. fuse & 12 KV post insulators including nut, bolt & washers as required as per technical specifications, approved drawings and scope of work.
Fixing of Galvanized Stay set of 1.8 m long, 16 mm diameter solid GS stay rod & 300x300x4 mm anchor plate including, 2 Nos. 50x8 m Stay clamp, 1 nos. HT stay guy insulator, nut bolts, 2 Nos. turn buckles & 7/3.15 mm dia GI stranded wire etc., as required as per technical specification, approved drawings and scope of work.
In normal soil
In ordinary rock/Hard Soil which does not require drilling
In ordinary rock/Hard Soil which require drilling
Fixing of 11 KV Polymer Composite Pin Insulator with pin on pole complete in all respect
Fixing of Composite Polymer Disc insulators with hardware for 11 KV 45 KN “T&C” type (as per latest specification and drawings adopted and approved by NIGAM)
Erection of 11 KV Danger plate of size 200 X 250 mm complete in all respect
Fixing of PG clamps (Weasel to Weasel) made of aluminum alloy as per IS:617-1994 . All ferrous metal part intended for outdoor use except those made of stainless steel shall be protected by hot dip galvanizing in accordance with IS 2633-1986(latest amended)
Erection of Distribution class (5 KA 9 KV Distribution class) lightening arrestors on the existing brackets in all respect as required including hardware, nut , bolt & washers etc.
Erection of M.S. Nuts & Bolts (Galvanized) of assorted size
(G) Replacement of old frayed Conductors
G-(1) 11 kV Line : Augmentation/Reconductoring of Dog and Weasel
Erection of PCC Poles in all types of soil & allignment including excavation of pit size 1.2x0.6x1.5 cum. for 9 mtrs (200 Kg) PCC poles in ground and back filling soil consolidating each deposit layer of 0.15 mtr. by watering and ramming etc. in the length.
In normal soil
In ordinary rock/Hard Soil which does not require drilling
In ordinary rock/Hard Soil which require drilling
Fixing of 11 KV V Cross arm with top hamper & clamps (galvanized as per IS), 0.2 m long made of MS Channel 100x50x6 mm, MS Angle 65x65x6 mm & MS flat of size 50x6 mm weight(12.789 Kg.) Approx.
Fixing of 11 KV Polymer Composite Pin Insulator with pin on pole complete in all respect
Fixing of Composite Polymer Disc insulators with hardware for 11 KV 45 KN “T&C” type (as per latest specification and drawings adopted and approved by NIGAM)
Drawing & Stringing of overhead steel cored aluminum ACSR WEASEL [30 sq.mm (6+1)/(2.59+2.59) mm ]conductor.
Fixing of PG clamps (Weasel to Weasel) made of aluminum alloy as per IS:617-1994 . All ferrous metal part intended for outdoor use except those made of stainless steel shall be protected by hot dip galvanizing in accordance with IS 2633-1986(latest amended)
Fixing of Galvanized Stay set of 1.8 m long, 16 mm diameter solid GS stay rod & 300x300x4 mm anchor plate including, 2 Nos. 50x8 m Stay clamp, 1 nos. HT stay guy insulator, nut bolts, 2 Nos. turn buckles & 7/3.15 mm dia GI stranded wire etc., as required as per technical specification, approved drawings and scope of work.
In normal soil
In ordinary rock/Hard Soil which does not require drilling
In ordinary rock/Hard Soil which require drilling
Erection of 11 KV Danger plate of size 200 X 250 mm complete in all respect
Erection of M.S. Nuts & Bolts (Galvanized) of assorted size
Dismenteling work in 11 KV Reconductoring
11KV, V type cross arms.
11KV Top hamper
11KV porclain pin insulators.
11KV GI Pins
11KV B&S/T&C type porcelain disc insulators. 45 KN.
H/W for 11KV B&S/T&C type porcelain disc insulators 45 KN.
AAC/AAAC/ACSR Conductor
GI wire No. 8 SWG
G-(2) Replacement O/H L.T. line by LT INSULATED RABBIT CONDUCTOR
Erection of PCC Poles in all types of soil & allignment including excavation of pit size 1.2x0.6x1.5 cum. for 9 mtrs (200 Kg) PCC poles in ground and back filling soil consolidating each deposit layer of 0.15 mtr. by watering and ramming etc. in the length.
In normal soil
In ordinary rock/Hard Soil which does not require drilling
In ordinary rock/Hard Soil which require drilling
Erection of LT Insulated Rabbit Conductor [50 sq mm (6 X 3.35 + 1 X 3.35) mm] on existing cross arms through insulator including binding with 6 mm soft aluminium conductor & twisting etc. complete in all respect. (Cost of material includes the sag and jumpering) as per latest specification & drawing adopted and approved by Nigam
Fixing of Galvanized Stay set of 1.8 m long, 16 mm diameter solid GS stay rod & 300x300x4 mm anchor plate including, 2 Nos. 50x8 m Stay clamp, 1 nos. HT stay guy insulator, nut bolts, 2 Nos. turn buckles & 7/3.15 mm dia GI stranded wire etc., as required as per technical specification, approved drawings and scope of work.
In normal soil
In ordinary rock/Hard Soil which does not require drilling
In ordinary rock/Hard Soil which require drilling
Erection of LT cross arm with clamp(Galvanized as per IS) 600mm long made of MS Angle 50x50x6mm & MS Flat 50x6 mm on the existing pole/joist complete. Weight(3.150 Kg+ 1.083 Kg) Approx.
Fixing of LT Porcelain Pin Insulators with pin (as per latest specification and drawings adopted & aprpoved by the NIGAM).
Fixing of LT Porcelain Shackle Insulators with hardware as per latest specification and drawings adopted & approved by the NIGAM.
Erection of M.S. Nuts & Bolts (Galvanized) of assorted size
Dismenteling work in LT Reconductoring
LT BRACKET 2' LONG WITH CLAMP
LT SHACKLE INSULATOR
LT SHACKLE H/W
LT PIN INSULATOR
LT GI PIN
AAC/AAAC/ACSR Conductor
(H) Provision of AB Cable
H-(1) LT AB Cable Single Phase
Erection of PCC Poles in all types of soil & allignment including excavation of pit size 1.2x0.6x1.5 cum. for 9 mtrs (200 Kg) PCC poles in ground and back filling soil consolidating each deposit layer of 0.15 mtr. by watering and ramming etc. in the length.
In normal soil
In ordinary rock/Hard Soil which does not require drilling
In ordinary rock/Hard Soil which require drilling
Laying of overhead ABC(Aerial bunched cable) 1Cx25+1x25 sqmm.
Fixing of Galvanized Stay set of 1.8 m long, 16 mm diameter solid GS stay rod & 300x300x4 mm anchor plate including, 2 Nos. 50x8 m Stay clamp, 1 nos. HT stay guy insulator, nut bolts, 2 Nos. turn buckles & 7/3.15 mm dia GI stranded wire etc., as required as per technical specification, approved drawings and scope of work.
In normal soil
In ordinary rock/Hard Soil which does not require drilling
In ordinary rock/Hard Soil which require drilling
Erection & fixing of suspension clamps with eye hook bolt and PCC Pole Clamps (NFC type) suitable for AB Cable Complete in all respect.
Erection & fixing of dead end clamp with eye hook bolt and PCC Pole Clamps (NFC type) suitable for AB Cable Complete in all respectt.
Erection & fixing of LT Insulation piercing connector (French standard) Type-A suitable for AB cable Complete in all respect.
Erection & fixing of Insulation piercing connector (French standard) Type-B suitable for AB cable Complete in all respect.
H-(2) LT AB Cable Three Phase
Erection of PCC Poles in all types of soil & allignment including excavation of pit size 1.2x0.6x1.5 cum. for 9 mtrs (200 Kg) PCC poles in ground and back filling soil consolidating each deposit layer of 0.15 mtr. by watering and ramming etc. in the length.
In normal soil
In ordinary rock/Hard Soil which does not require drilling
In ordinary rock/Hard Soil which require drilling
Erection of overhead ABC(Aerial bunched cable) 3Cx25+1x25 sqmm.
Fixing of Galvanized Stay set of 1.8 m long, 16 mm diameter solid GS stay rod & 300x300x4 mm anchor plate including, 2 Nos. 50x8 m Stay clamp, 1 nos. HT stay guy insulator, nut bolts, 2 Nos. turn buckles & 7/3.15 mm dia GI stranded wire etc., as required as per technical specification, approved drawings and scope of work.
In normal soil
In ordinary rock/Hard Soil which does not require drilling
In ordinary rock/Hard Soil which require drilling
Erection & fixing of suspension clamps with eye hook bolt and PCC Pole Clamps (NFC type) suitable for AB Cable Complete in all respect.
Erection & fixing of dead end clamp with eye hook bolt and PCC Pole Clamps (NFC type) suitable for AB Cable Complete in all respectt.
Erection & fixing of LT Insulation piercing connector (French standard) Type-A suitable for AB cable Complete in all respect.
Erection & fixing of Insulation piercing connector (French standard) Type-B suitable for AB cable Complete in all respect.
H-(3) LT UNDERGROUND CABLE
LAYING, ENERGISATION & COMMISSIONING OF LT UNDERGROUND CABLE FOR WORKING VOLTAGE OF 1.1KV, ALUMINIUM CONDUCTOR, XLPE INSULATED ARMOURED CABLE AS PER IE RULES AND METHODS OF IS:1255/JVVNL STANDARDS INCLUDING EXCAVATION OF 30CMX120 CM DEEP TRENCH IN THE LAND SPECIFIED BELOW, 25 CM. THICK UNDER LAYER OF SAND, "A" CLASS BRICK COVERING, REFILLING OF EARTH IN THE REMAINING PORTION, AS PER LATEST SPECIFICATIONS AND DESIGN & DRAWING FIXING WITH CABLE CLAMPS, MAKING CONNECTIONS/ JUMPERS BY ALUMINUM LUGS/ P.G.CLAMPS OF REQUIRED SIZE ON L.V. SIDE OF DISTRIBUTION TRANSFORMER/ LT DISTRIBUTION MAINS ON 1 END AND WITH ICTP SWITCH/FUSE UNIT/PILLAR BOX ON THE OTHER END LUGS SHOULD BE CRIMPED WITH CRIMPING TOOL LUGS/P.G.CLAMPS AS PER DRAWING APPROVED BY NIGAM). [ROAD CROSSING OF CABLE SHALL BE IN DOUBLE WALLED CORRUGATED PIPE OF 200 MM DIAMETER] MAKING NECESSARY CONNECTION INCLUDING TESTING ETC. AS REQUIRED AND PROVIDING /FIXING CABLE ROUTE INDICATORS AT EVERY 30 MTR OF CABLE & AT EVERY TURN (AS PER LATEST SPECIFICATIONS AND DESIGN & DRAWING APPROVED BY NIGAM).
LT XLPE INSULATED ARMOURED CABLE OF SIZE 4CX185 SQ.MM IN BRICKS AS PER STANDARD (Kachha road)
LT XLPE INSULATED ARMOURED CABLE OF SIZE 4CX185 SQ.MM IN BRICKS AS PER STANDARD (Pakka road)
LT XLPE INSULATED ARMOURED CABLE OF SIZE 4CX185 SQ.MM IN DWC PIPE OF DIA.200 MM at Road crossing or wherever it is required.
LT XLPE INSULATED ARMOURED CABLE OF SIZE 4CX185 SQ.MM BY HDD VERMIER (WHERE BLASTING IS NOT REQUIRED) / PACCA ROAD
INSTALLATION OF LT SUPPLY DISTRIBUTION BOX & CHANGE OVER FOR WITHSTAND UNDERGROUND SERVICE LINE AS PER SPECIFICATION OF NIGAM. EACH BASE SHOULD BE GROUTED INCLUDING EXCAVATION, BRICKS, SAND, CEMENT MASONARY OF SIZE 4"X3"X10" AND 3' IN GROUND & 1.5 ' ABOVE ROAD LEVEL WITH MUFFING TO SUPPORT & MOUNTING THE PILLAR. THE MASONARY WILL HAVE 4"X4" OPENING 2" BELOW GROUND LEVEL TWO IN REAR SIDE & ONE EACH IN THE REMAINING SIDES TO FACILITATE ENTRY & EXIT OF INCOMING & OUT GOING CABLES. EARTHING OF THE PILLAR SHALL BE CONNECTED TO TWO SIDES OF DISTRIBUTION BOX WITH 7/8 SWG GI WIRE & LUGS DULY BOLTED ON THE PLACE MEANT FOR. XLPE CABLES INSIDE THE BOX SHALL BE FIXED WITH CLAMPS MAKING CONNECTIONS /JUMPERS BY ALUMINIUM. LUGS OF REQUIRED SIZE ON LT DISTRIBUTION MAINS ON ONE END & WITH MCB/ WITH ISOLATOR ON THE OTHER END. LUGS SHOULD BE CRIMPED WITH CRIMPING TOOLS INCLUDING COST OF LUGS & NUTS, BOLTS ETC.
LT Distribution piller Boxes of 400 Amps. Capacity.Each 37"x24" base as per AVVNL standard including excavation,bricks,sand,cement masonary of size 4"x3"x10"and 3' in ground and 1 1/2'above road level with muffing to support and mounting the piller .Themasonary will have 4" X 4" opening 2"below ground level two in the rear sideand one each in the remaining sides to facilitate entry and exist of incomingand outgoing PVC cable.Earthing of the piller shall be connected to DP earth with 7/10 SWG StayWire & lugs.
LT distribution kiosk 200 Amp. suitable for distribution for Main Line & Service Connections as per Nigam drawing/specifications
Erection of earthing rod sets for 11KV lines made with MS Rod (Galvanized) 20 mm dia, 3 meter length alongwith GI wire 8 SWG (approx.) total length / weight, 17 meter / 1.64 Kg.) as per latest specification and drawing adopted & approved by NIGAM.
Intallation of Cable termination / straight through joints on LT XLPE INSULATED ARMOURED CABLE OF SIZE 4CX185 SQ.MM with outdoor straight through joint including required excavation /remoral/fixing/refixing/ testing etc. as required.
Laying of service line LT PVC Insulated and PVC Sheathed armoured underground cable with proper connection to MCCB fixed in LT Distribution box to consumer meter location through underground trench as per relevant IS/ Specification using G.I./HDPE Pipe from service mains in LT Distribution box to Meter Box terminals using lugs/crimping pins at both ends. The work includes connecting the armour wire with meter box & earth of distribution lines with suitable clamps for proper earthing of the cable. The Armoured XLPE cable hooked to supporting pipeor MS Angle through anchor hook must be fixed on wall and with proper clamp up to meter box at an interval of 1 meter.
FOR SINGLE PH - 2CX4 SQ.MM
FOR THREE PH - 4CX16 SQ.MM
Providing and fixing of GI pipe of 125mm diameter. B class(IS:1239 mark),at the starting and finishing point of 33KV under ground cables and to lay & clamp vertically with the existing support including labour charges.
Providing and laying of cement concrete in ratio 1:3:6 using 43 grade cement river sand and 12 mm to 20 mm graded blast crusher broken in pit/foundation according to the size/type of support/stay set including compacting/curing for 21 days in steel plates shuttering/farmer base.
(I) 1-Phase & 3-Phase Armoured Service Line Cabling Work
Erection of ISI mark 2CX4 Sq.mm. 1100 Volt heavy duty armoured PVC XLPE Cable of Aluminium conductor conforming to IS:7098 (Part-I) (latest amended).
Fixing of 4 in 1 Deepdrawn Meter Box with multiple outgoing connector.
Fixing of 6 in 1 Deepdrawn Meter Box with multiple outgoing connector.
Erection of ISI mark 4CX16 Sq.mm. 1100 Volt heavy duty armoured PVC XLPE Cable of Aluminium conductor conforming to IS:7098 (Part-I) (latest amended).
(J) Electric Vehicle Charging Station Infra
J-(1) 11 KV over head line 3 Phase of EV Charging
Erection of PCC Poles in all types of soil & allignment including excavation of pit size 1.2x0.6x1.5 cum. for 9 mtrs (200 Kg) PCC poles in ground and back filling soil consolidating each deposit layer of 0.15 mtr. by watering and ramming etc. in the length.
In normal soil
In ordinary rock/Hard Soil which does not require drilling
In ordinary rock/Hard Soil which require drilling
Drawing of overhead steel cored aluminum ACSR Rabbit Conductor.
Fixing of 11 KV V Cross arm with top hamper & clamps (galvanized as per IS), 0.2 m long made of MS Channel 100x50x6 mm, MS Angle 65x65x6 mm & MS flat of size 50x6 mm weight(12.789 Kg.) Approx.
Fixing of Galvanized Stay set of 1.8 m long, 16 mm diameter solid GS stay rod & 300x300x4 mm anchor plate including, 2 Nos. 50x8 m Stay clamp, 1 nos. HT stay guy insulator, nut bolts, 2 Nos. turn buckles & 7/3.15 mm dia GI stranded wire etc., as required as per technical specification, approved drawings and scope of work.
In normal soil
In ordinary rock/Hard Soil which does not require drilling
In ordinary rock/Hard Soil which require drilling
Fixing of 11 KV double pole line structure set for cut point complete on existing poles in all respect with clamp, nut & bolts as requried made from M.S.Channel 100 x 50x6 , M.S.Angle 65 x 65 x 6 mm, M.S.Angle 50 x 50 x 6 mm and M.S.Flat 50 x 6 mm ( 101.383 Kg. Approx.) (Galvanized as per IS)
Fixing of earthing rod sets for 11KV lines made with MS Rod (Galvanized) 20 mm dia, 3 meter length alongwith GI wire 8 SWG (approx.) total length / weight, 17 meter / 1.64 Kg.) as per latest specification and drawing adopted & approved by NIGAM.
Fixing of 11 KV Polymer Composite Pin Insulator with pin on pole complete in all respect
Fixing of Composite Polymer Disc insulators with hardware for 11 KV 45 KN “T&C” type (as per latest specification and drawings adopted and approved by NIGAM)
Fixing of PG clamps for rabbit made of aluminum alloy as per IS:617-1994 . All ferrous metal part intended for outdoor use except those made of stainless steel shall be protected by hot dip galvanizing in accordance with IS 2633-1986(latest amended)
Erection of 8 SWG (4 mm dia) GI wire for continuous earthing of 11 KV Line hot dip (Galvanized)
Erectionof 11 KV Danger plate of size 200 X 250 mm complete in all respect
Erection of Guarding brackets ( 1 set = 2 Nos.) per span of 11 KV made of M.S. Angle 65X65X6 mm with clamps made of Flat 50x6, using Eye Hook 300X16 mm (75% Thread with Nut of Suitable Size) (galvanized)
Erection of M.S. Nuts & Bolts (Galvanized) of assorted size
J-(2)11 KV under ground cable of EV Charging
Laying of two (Double circuit) 11KV, XLPE (Aluminium conductor) undrground cables of SIZE 3X185 SQ.MM w/o overlapping as per relevant IS/ AVVNL standard including excavation of 50 cm width x 120 cm deep trench in Kaccha land.25 cm thick under layer of sand. 'A' class bricks or concrete block covering refilling soil in the remaining portion and providing/fixing cable route indicators at every 30Mtr.of cable and at every turn.
LAYING IN BRICKS AS PER STANDARD (Kachha road)
LAYING IN BRICKS AS PER STANDARD (Pakka road)
LAYING IN DWC PIPE OF DIA.200 MM FOR CABLE at Road crossing or wherever it is required.
Laying of Single circuit (S/C) 11 KV XLPE 3CX185 sqmm cable without Road cutting i.e. through burrowing machine "VERMIER".(120 cm deep).Use of this technology must be restricted to the situation like:-
Fixing of Cable End Termination Kit/ST Joint, Making Outdoor/ Indoor Joint For11 kV Aluminum Conductor XLPE Armoured HT Cable With Outdoor And Terminal End Preparation Of Joint As Per Manufactures Kit Guidance And Direction Including Preparation Of Cable End & Testing etc.
XLPE 3X185 SQ.MM H.S. ON OUTDOOR TYPE
XLPE 3X185 SQ.MM H.S.S.T. JOINT
Fixing of earthing rod sets for 11KV lines made with MS Rod (Galvanized) 20 mm dia, 3 meter length alongwith GI wire 8 SWG (approx.) total length / weight, 17 meter / 1.64 Kg.) as per latest specification and drawing adopted & approved by NIGAM.
PROVIDING AND FIXING OF G.I. PIPE OF 125 MM DIAMETER, B-CLASS (IS:1239 MARK), AT THE STARTING AND FINISHING POINT OF 11 KV UNDER GROUND CABLES AND TO LAY & CLAMP VERTICALLY WITH THE EXISTING SUPPORT, INCLUDING LABOUR CHARGES.
Providing and laying of cement concrete in ratio 1:3:6 using 43 grade cement river sand and 12 mm to 20 mm graded blast crusher broken in pit/foundation according to the size/type of support/stay set including compacting/curing for 21 days in steel plates shuttering/farmer base.
Fixing of Clamp of M S Flat 50x6 mm(2x0.501m, wt. 2.36 Kg. Approx)
J-(3) DISTRIBUTION TRANSFORMER THREE PHASE (100 KVA and 160 KVA) of EV Charging
Erection of PCC Poles in all types of soil & allignment including excavation of pit size 1.2x0.6x1.5 cum. for 9 mtrs (400 KG) and 1.2x0.6x1.35 cum PCC poles in ground and back filling soil consolidating each deposit layer of 0.15 mtr. by watering and ramming etc. in the length.
In normal soil
In ordinary rock/Hard Soil which does not require drilling
ordinary rock / CC Road which require drilling
Installation of 11 /0.4 KV 100 KVA Al wound conventional outdoor type distribution transformers with all fittings and accessories and first filling of transformer oil alongwith MCCB. Protection on LV side confirming to technical specification
Laying of overhead ABC(Aerial bunched cable) 1Cx25+1x25 sqmm.
Drawing & Stringing of overhead steel cored aluminum ACSR WEASEL [30 sq.mm (6+1)/(2.59+2.59) mm ]conductor.
Erection of 11/0.4 KV SubStation structure set (Galvanized) on existing poles in all respect with clamps as required made from M.S. channel 100x50 X6 mm, 75x40x6 mm, M.S. angle 75x75x6 mm, and M.S. flat 50x6 mm weight(166.746 kgs.) Approx
Fixing of horn gap sets on existing brackets in all respect as required including hardware nut & bolt & washer etc. ( with 6 x 24 KV Post Insulator ) 1 Set=3 Nos
Erection of set of 3 nos. of earthing rod sets for S/S made with MS Rod (Galvanized) 20 mm dia, 3 meter length alongwith GI wire 8 SWG (approx. total length / weight, 50 m / 4.907 Kg.) as per latest specification and drawing adopted & approved by NIGAM.
Fixing of 11KV ( with 9 x 12 KV Post Insulator ) 400 Amp. GO double break without EB Isolator on existing bracket complete in all respect as required including hardware etc.
Fixing of Galvanized Stay set of 1.8 m long, 16 mm diameter solid GS stay rod & 300x300x4 mm anchor plate including, 2 Nos. 50x8 m Stay clamp, 1 nos. HT stay guy insulator, nut bolts, 2 Nos. turn buckles & 7/3.15 mm dia GI stranded wire etc., as required as per technical specification, approved drawings and scope of work.
In normal soil
In ordinary rock/Hard Soil which does not require drilling
In ordinary rock/Hard Soil which require drilling
Fixing of 11 KV Polymer Composite Pin Insulator with pin on pole complete in all respect
Fixing of Composite Polymer Disc insulators with hardware for 11 KV 45 KN “T&C” type (as per latest specification and drawings adopted and approved by NIGAM)
Erection of 11 KV Danger plate of size 200 X 250 mm complete in all respect
Fixing of PG clamps (Weasel to Weasel) made of aluminum alloy as per IS:617-1994 . All ferrous metal part intended for outdoor use except those made of stainless steel shall be protected by hot dip galvanizing in accordance with IS 2633-1986(latest amended)
Erection of M.S. Nuts & Bolts (Galvanized) of assorted size
Description of Work / Item(s)
Total price of Suppy (BoQ1/Schedule-1)
Total price of Erection (BoQ2/Schedule-2)
Naolin Infrastructure Private Limited
AARVANSS BUILDWELL AND INFRACON LLP
India Commercial Services
Hitesh Electricals
Naolin Infrastructure Private Limited
AARVANSS BUILDWELL AND INFRACON LLP
Naolin Infrastructure Private Limited
India Commercial Services
AARVANSS BUILDWELL AND INFRACON LLP
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.39 MB
AVVNL_RDSS_InfraSBD_Part1_221022.pdf
Tender Documents • 0.70 MB
AVVNL_RDSS_InfraSBD_Part2_221022.pdf
Tender Documents • 1.34 MB
AVVNL_RDSS_InfraSBD_Part3_221022.pdf
Tender Documents • 1.04 MB
AVVNL_RDSS_TechSpec_221022.pdf
Tender Documents • 11.64 MB
BOQ_536848.xls
BOQ • 1.20 MB
Download all tender documents and submit your bid