| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹60.9 LAccepted-AOC 41 MORAR ENCLAVE GOLA KA MANDIR MORAR GWALIOR MP PIN 474005 | GWALIOR | GWALIOR | MADHYA PRADESH | 474005 | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹67.6 L+₹5.7 L (9.27%)Rejected-Finance | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹69.7 L+₹7.8 L (12.7%)Rejected-Finance OFFICE 4 9 SWARG ASHRAM NANAK RAM COLONY PARMANAND CHOWK DELHI 110009 | DELHI | DELHI | DELHI | 110009 | L3 | Rejected-Finance Not lowest bidder | |
| 4 | L4₹70.7 L+₹8.9 L (14.4%)Rejected-Finance 205 KRISHNA NAGAR GOLA KA MANDIR NEAR AIRTEL TOWER NO 01 MORAR GWALIOR 474005 | GWALIOR | GWALIOR | MADHYA PRADESH | 474005 | L4 | Rejected-Finance Not lowest bidder | |
| 5 | L5₹71.3 L+₹9.5 L (15.3%)Rejected-Finance HOUSE NO 03 RAGHAVPURAM MALL ROAD MORAR GWALIOR | GWALIOR | GWALIOR | MADHYA PRADESH | L5 | Rejected-Finance Not lowest bidder |
| Sl No | Description | Qty | Unit | M.S. ENGINEERS L6 | M/S YOGANSH CONSTRUCTION CO. L7 | Ravi Associates L1 | M/s Himgiri construction L3 | M/s. Ravi and brothers L5 | BEHL CONSTRUCTION CO L4 | SHRI RAM CONSTRUCTION L8 | Arkay Instrumentation L2 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down existing unserviceable treatment of any description including cement plaster any thickness from roof surfaces, cleaning of roof surfaces and preparing it for further treatment and removing rubbish from the site complete all as specified and directed | 507 | Sqm | 25 ₹12,675 | 20 ₹10,140 | 20 ₹10,140 | 8 ₹4,056 Lowest | 15 ₹7,605 | 10 ₹5,070 | 25 ₹12,675 | 10 ₹5,070 |
| 2.00 | M&L, 10mm thick Screed bed or bedding layer of mortar on prepared top of roof surfaces of any description in cement mortar 1:3 mixed with water proofing compound as per manufacture instruction on concrete roof surface finished fair and even to maintain the proper slope of roof surface and smooth complete all as specified and directed.
Note : WPC shall be measured & paid seperately. | 507 | Sqm | 140 ₹70,980 | 110 ₹55,770 Lowest | 120 ₹60,840 | 110 ₹55,770 Lowest | 160 ₹81,120 | 380 ₹1,92,660 | 150 ₹76,050 | 170 ₹86,190 |
| 3.00 | Cleaning of plastered roof surfaces and applying a coat of bitumen primer @ 0.30 kg/sqm on top of dry surface of finished cement morter plaster | 507 | Sqm | 15 ₹7,605 | 35 ₹17,745 | 10 ₹5,070 Lowest | 12 ₹6,084 | 30 ₹15,210 | 80 ₹40,560 | 50 ₹25,350 | 60 ₹30,420 |
| 4.00 | One coat of hot bitumen primer of grade 85/25 @ 1.2 kg/Sqm shall be applied over primed surfaces. | 507 | Sqm | 40 ₹20,280 | 120 ₹60,840 | 10 ₹5,070 Lowest | 45 ₹22,815 | 60 ₹30,420 | 75 ₹38,025 | 50 ₹25,350 | 70 ₹35,490 |
| 5.00 | M&L, for APP based polymeric membrane minimum weighing 3.5kg/Sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) laid on primed surface by torch application method complete all as specified. | 507 | Sqm | 300 ₹1,52,100 | 285 ₹1,44,495 | 280 ₹1,41,960 | 270 ₹1,36,890 Lowest | 290 ₹1,47,030 | 350 ₹1,77,450 | 350 ₹1,77,450 | 280 ₹1,41,960 |
| 6.00 | M & L for 20-25mm thick PCC tiles using grey cement of size 250x250mm ISI marked over 15mm thick bedding mortar in CM 1:3 set and jointed complete all as specified and directed. | 507 | sqm | 480 ₹2,43,360 | 425 ₹2,15,475 Lowest | 450 ₹2,28,150 | 490 ₹2,48,430 | 480 ₹2,43,360 | 780 ₹3,95,460 | 700 ₹3,54,900 | 500 ₹2,53,500 |
| 7.00 | Dismantling of stone slab and tiles of any description or thickness in floor, aprons etc laid dry and pointed in any mortar complete all as specified and directed. | 17 | 10 Sqm | 180 ₹3,060 | 200 ₹3,400 | 100 ₹1,700 | 77 ₹1,309 Lowest | 100 ₹1,700 | 500 ₹8,500 | 250 ₹4,250 | 100 ₹1,700 |
| 8.00 | M&L for machine cut kota stone of size 550x550 flooring 18 to 20mm thick laid over cement screed base/ 15 mm thick in CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed. | 127 | Sqm | 850 ₹1,07,950 | 765 ₹97,155 | 870 ₹1,10,490 | 850 ₹1,07,950 | 900 ₹1,14,300 | 1,100 ₹1,39,700 | 800 ₹1,01,600 | 700 ₹88,900 Lowest |
| 9.00 | M&L for machine cut Kota stone slab 18-20 mm thick in riser of steps, skirting, dado and pillar over cement mortar rendering in 15 mm thick in CM 1:6 and jointed complete all as specified and directed. | 15 | Sqm | 950 ₹14,250 | 810 ₹12,150 | 900 ₹13,500 | 890 ₹13,350 | 900 ₹13,500 | 1,050 ₹15,750 | 800 ₹12,000 | 700 ₹10,500 Lowest |
| 10.00 | M&L Granite (of any type) tiles 18 mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete, laid over and including 15mm thick screed in CM 1:4 complete all as specified and directed. | 27 | Sqm | 1,800 ₹48,600 Lowest | 2,600 ₹70,200 | 1,800 ₹48,600 Lowest | 1,900 ₹51,300 | 2,200 ₹59,400 | 2,200 ₹59,400 | 2,200 ₹59,400 | 2,000 ₹54,000 |
Tender Value
₹96 L
EMD Value
₹1.7 L
Closing Date
29 Dec 2025, 6:00 pmClosed
SHRI ANIL KUMAR, IDSE, SE, CWE
HQ CWE JHANSI
ADDN AND ALTERATION WITH SPECIAL REPAIR TO CERTAIN BLDG UNDER GE GWALIOR
2025_MES_741980_1
CWE/JHA/GWL/TOKEN/82 OF 2025-26
Open Tender
Civil Works
Item Rate
240 days
GWALIOR
AS PER NIT AND TENDER DOCUMENTS
9 documents required · 9 mandatory
₹1,000
GE GWALIOR
₹1.7 L
Yes
9 Feb 2026
28 Nov 2025
31 Dec 2025
28 Nov 2025
29 Dec 2025
20 Dec 2025
Amount
Taking down existing unserviceable treatment of any description including cement plaster any thickness from roof surfaces, cleaning of roof surfaces and preparing it for further treatment and removing rubbish from the site complete all as specified and directed
M&L, 10mm thick Screed bed or bedding layer of mortar on prepared top of roof surfaces of any description in cement mortar 1:3 mixed with water proofing compound as per manufacture instruction on concrete roof surface finished fair and even to maintain the proper slope of roof surface and smooth complete all as specified and directed. Note : WPC shall be measured & paid seperately.
Cleaning of plastered roof surfaces and applying a coat of bitumen primer @ 0.30 kg/sqm on top of dry surface of finished cement morter plaster
One coat of hot bitumen primer of grade 85/25 @ 1.2 kg/Sqm shall be applied over primed surfaces.
M&L, for APP based polymeric membrane minimum weighing 3.5kg/Sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) laid on primed surface by torch application method complete all as specified.
M & L for 20-25mm thick PCC tiles using grey cement of size 250x250mm ISI marked over 15mm thick bedding mortar in CM 1:3 set and jointed complete all as specified and directed.
Dismantling of stone slab and tiles of any description or thickness in floor, aprons etc laid dry and pointed in any mortar complete all as specified and directed.
M&L for machine cut kota stone of size 550x550 flooring 18 to 20mm thick laid over cement screed base/ 15 mm thick in CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L for machine cut Kota stone slab 18-20 mm thick in riser of steps, skirting, dado and pillar over cement mortar rendering in 15 mm thick in CM 1:6 and jointed complete all as specified and directed.
M&L Granite (of any type) tiles 18 mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete, laid over and including 15mm thick screed in CM 1:4 complete all as specified and directed.
Dismantling floor, hearth or wall tiling of any description and in any position including cement mortar bedding (but not backing) complete all as specified and directed.
M&L for Glazed Ceramic tiles, 400x400mmx7mm in floor etc set and jointed in neat cement slurry and pointed in coloured cement to match including 15mm thick in CM (1:6), complete all as specified and directed.
M&L for non - skid ceramic tile coloured 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floor etc set and jointed in neat cement slurry and pointed in coloured cement to match including laid over screed 15mm thick in CM (1:6), complete all as specified and directed.
Ditto- but tiles in vertical surfaces of wall set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10 mm thick rendering in CM 1:4 complete all as specified and as directed.
M&L for Glazed ceramic tiles in vertical surface 350x250x7mm/450x350x7mm thick set and jointed in neat cement slurry and pointed in coloured cement to match, laid over and including rendering 10 mm thick on fair faces brick work or concrete surface in cement plaster 1:4 complete all as specified and directed.
Taking down cement or cement lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement plaster 1:6, finished even and smooth (without using extra lime or cement) complete all as specified and directed.
M&L for new plasterd surface applying two coats of distemper oil emulsion white or tinted over and including a layer of 1mm thick wall care putty on wall complete all as specified.
M&L for rendering 15 mm thick on other than fair faces of brick work or concrete surfaces in cement plaster 1:4 and mixed with WPC , finished even and smooth (without using extra lime or cement) complete all as specified and directed. (Note:- WPC shall be measured & paid seperately).
Material & Labour for new plastered surfaces applying two or more coats of 100% Premium acrylic exterior emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces including a layer of 1.5mm thick wall care putty on wall complete all as specified and directed.
M&L for rendering 5 mm thick in Cement Mortar (1:3) on ceiling finished even and smooth without using extra cement complete all as specified and directed.
M&L for preparation of the newly plastered surfaces of ceiling & applying 3 coats of white wash on ceiling surfaces complete all as specified and directed.
Taking down chowkhat frame with shutter (without taking out shutter from the frame) exc 1.50 Sqm but n exc 4 Sqm each complete all as specified and directed.
Taking down chowkhat frame with shutter (without taking out shutter from the frame) n.exc 1.50 Sqm each complete all as specified and directed.
S&F for pressed steel frame of size 125 x 60 mm for door with one or more rebates makaing necessary fixing lugs, hinges, lock strike plate, etc, complete, as specified, complete all as specified and directed.
S&F for pressed steel frame of size 105 x 60 mm for door with one or more rebates makaing necessary fixing lugs, hinges, lock strike plate, etc, complete, as specified, complete all as specified and directed.
S&F for 30mm thick factory made glazed and skelton shutters 2nd class HW open rebated and prepared to receive gauage (with sash bars) edges of framing plain, chamfered or rounded, fitted with cut and mitred bead or security glass etc. Size of members of shutters as specified in IS-1003 supplied and fitted to chowkhats complete all as specified and directed.
S&f 35mm thick flush shutters, soild core construction with block board core and plywood face panels, decorative laminate type 1 of 0.9mm thick surface finish colour and pattern as approved fixed with approved adhensive as manufacture's complete all as specified and directed
S&F in repairs Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60(Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proofand fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately).
S&F inrepair Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30 mm size comprising of virgin polymer of K value 58-60(Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge.
S&F Eco 4000 series windows/ventilators (Double rebate) fabricated from roll formed section made of galvanised steel colour coated/powder coated (Base steel as per IS 513 "D"quality, Galvanized as per IS 277 with zinc of 120 grams/sqmt with total coated thickness of 0.60mm coated section should be with primer coat of epoxy primer of 5-7 microns thick, finish painted with polyester paint of 12-16 microns thick or powder coated with pure polyester upto 50-60 micron thick. section for frame should be72mmX55mm, section for mullion should be of 72mm X50mm section for Glazed shutter frame should be of 47mmX20mm and section for fixed glass bead should be 12mmx12mm section for fly mesh should be of 40mm X20mm. Section for frame Glazed shutter and mesh shutters should be cut to length and miter joined with polypropylene corner brackets. mullions section should be joined with frame/mullion using mullion cap Ethyl propylene diamine monomer (EPDM) gasket should be used all around glass in shutter and fixed glass including grill of same material . Spoon profile should be used around fly mesh to fix mesh in mesh shutter. Each glazed shutter and mesh shutter should be provided with SS pivot hinges -I set, seccolor stay. window frame should be fixed to brick/concrete masonryby using nylon self-expanding caps and drivingMS electroplated 80mm longscrews into the caps through frame.
S&F 4.8 mm thick sheet glass, ordinary quality and glazing with rubber gasket in square exceeding 0.5 Sqm in each pane for window, door, ventilator, complete all as specified and directed.
S&F 4.8 mm thick sheet glass, ordinary quality and glazing with rubber gasket in square n exceeding 0.5 Sqm in each pane for window, door, ventilator, complete all as specified and directed.
S&F stainless steel wire cloth,0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples
S&F for Butt hinges, 100 mm size, extruded aluminium alloy with galvanised mild steel hinge pin anodised and fixed complete all as specified and directed.
S&F for 200 mm aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed.
S&F for Aluminium handles, cast type anodised of Size 150 mm complete all as specified and directed.
S & F 300 mm aluminium alloy anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet , cast or extruded sections or cast aluminium alloy complete all as specified and directed.
S&F in replacements 140mm Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed
M&L for preparation of old wood or wood based surface of any description exceeding 10cm width or girth and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M&L for preparation of old Painted surface of any description exceeding 10cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
S&F in repair decorative stainless steel mild steel 25mm dia, minimum thickness 2 mm curtain rod with powder coated side fixing brackets, rings and decorative knobs at each end complete all as specified and directed
S&F in repair Stop valve, cast copper alloy, screwed down high pressure with capston headed handle chromium plated angular type screwed both ends for iron pipe 15mm bore or for unions and fixed complete all as specified and directed.
S&F in repair 15mm bore bib taps, fancy type chromium plated cast copper alloy with capaston head handle, screwed down screwed iron pipe or for brass ferule fixed, complete all as specified and directed.
Providing and fixing long body sink cock, nominal dia 15mm of approved quality conforming to IS Standards with 360 degree rotating with foam flow, Brass tap with chrome finish full Brass tap for kitchen sink tap with free flanges all as specified and directed
S&F in repair PVC connection 15mm size with PTMT nuts on both ends of length 450 mm complete all as specified and directed.
S&F in repair swivel shower of brass chromium plated of size 125mm for fixing with 15mm bore pipe complete all as specified and directed.
S&F in repair tabular towel rail, 20 mm dia, D type, 60 cm long between flanges, complete all as specified and directed.
S&F in repairs grating 100/125 mm dia of PTMT, fixed to Nahani trap complete all as specified and directed.
S&F in repair wash hand basin vitreous china (flat back) of size 550 x 400 mm excluding taps, waste, chain and plug and porcelain stopper but including brackets cutting for and pinning in ends complete all as specified and directed.
S&F in repair 32 mm waste fittings, brass chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly -nuts, flange end bedded in red lead cement and including pvc waste pipe other end fixed complete all as specified and directed.
S&F in repair kitchen sinks made of stainless steel 1mm thick with kitchen or laboratory with plug, washers, wastes, including fixing (cantilever brackets and connecting union to pipe overall size 495mm x 420mm boul size 410mm x 330mm x 160mm) including pvc waste pipe complete all as specified and directed.
Dismantling of water tank exceeding 250 Ltrs but not exceeding 500 Ltrs complete all as specified and directed.
S&F for rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) of capacity 500 litres hoisted and fixed in position all as specified in SSR Part-I, complete all as specified and directed.
S&F for as in replacement viterous china wash down water closet pan (pedestal pattern) or wall mounted white excluding fixing bolts, flushing cistern and flush pipe including connection to drain and to flushing pipe syphonage pipe etc and mild steel chromium plated or aluminised hinges device & on CP Jet complete all as specified and directed.
S&F in repair PVC flushing cistern 10 Ltrs capacity including all fitting flush pipe etc complete all as specified and directed.
S&F in repair Brass CP mixer for basin mixing hot and cold water screwed down for iron pipe and fixed complete all as specified and directed.
Taking down steel tubing and connection 15m bore incl cleaning for refixing or removing from site complete all as specified and directed.
M&L for GI tubing 15mm dia medium grade galvanised with all fittings fixed to wall and floor complete all as specified and directed.
~ Ditto ~ all as in item No. 59 above here in before but 20 mm dia pipe complete all as specified and directed.
~Ditto~ all as in item No.60 above here in before but 20 mm dia pipe complete all as specified and directed.
S&F of Glass Corner ,size nexc 250mmwith CP bracket
S&F in repair Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories), complete all as specified and directed.
S&F 110 mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls, complete all as specified and directed.
S&F 75 mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls, complete all as specified and directed.
S&F 75 mm PVC (SWR) pipes single socketed in any length with rubber ring joints, laid in trenches or in floors, complete all as specified and directed.
S&F PVC (SWR) bends any radius, 110mm bore, complete all as specified and directed.
S&F PVC (SWR) bends any radius, 75mm bore, complete all as specified and directed.
S&F PVC (SWR) junction single (single T), equal or unequal, 110mm bore, complete all as specified and directed.
S&F PVC (SWR) junction single (single T), equal or unequal, 75mm bore, complete all as specified and directed.
S&F MS rolled section/tubular sections in purling , cross, beam, rafter,posts etc. incl connected cleats, hold fasts etc of grade conforming to Fe 410-O or Fe 310-O all as specified and directed.
Demolition of cement concrete floor tiles (unreinforced) in ground floor and paving not exceeding 15 cm thickness (below or above ground level) incl the disposal upto 50M complete all as specified and directed.
M & L, hard core of for broken stone boulder of gauge n.exc 63mm deposited, spread and levelled in layers n.exc 15 cm thick watered and rammed to a true surfaces.
M&L for 75 mm thick PCC 1:3:6 type C-2 using 20mm graded stone aggrtegate as in plinth protection/path and the like including finsihing even & fair complete all as specified and directed.
Dismantling boarding, any description, fixed in any position with nails (including Cupboard shutter/Shelve upto 25mm thick) complete
S&F for 12mm thick BWP plywood type BB fixed with screws to timber frame work with reneered decorative laminate type 1 both faces of surface finish colour and pattern as approved fixed with approved adhensive as per manufacture instruction.
S&F for 18mm thick HDHMR plywood type BB fixed with screws to timber frame work with decorative laminate type 1 of surface finish colour and pattern as approved fixed with approved adhensive as per manufacture instruction.
S&F for continous (piano) hinges , mild steel, bright finished or electrogalvanised, width of flap 30mm complete all as specified and directed.
S&F for magnate catcher of metal body and striking plate heavy duty includind fixed with screw, complete all as specified and directed.
S&F Brass 2 Levers Cupboard locks grade 1, Size 50mm complete all as specified and directed.
S&F for 100 mm Brass handles, cast type, polished bright and fixed complete all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc. 1.5 m in depth for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and getting out in soft/loose soil complete all as specified and as directed (Note: As in foul condition manualy excavation works)
M&L for cutting into existing manholes for connecting new drains of 150 mm internal dia of pipe, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required complete all as specified and as directed.
Returning, filling in, including spreading ,leveling, watering and well ramming in layers n. exc 25 cm with soil complete all as specified and as directed.
Removal of excavated material (soil) to a distance n. exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and as directed.
Demolition and breaking up 150mm bore drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar complete all as specified and as directed. Note: Demolished material through out of MoD Land rate included above item.
S&F for reinforced concrete pipes 150mm bore class NP-2 laid and jointed with collar in CM 1:1 complete all as specified and as directed by Engr-in-Charge
M&L, PCC 1:4:8 type D2 using 40mm graded stone aggregate as in concrete bed to drain pipes of 150 mm bore including packing under, and haunching against the sides of pipes after they are laid and tested; including necessary form work complete all as specified and as directed.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in any type of soil complete all as specified.
M&L for Providing precast cement concrete 1:3:6 in window, doors, cills, lintes., string courses , coping etc. (Type C-1) . (of any section indicated), with plain fair faces, including chamfers, weatherings, throating etc. and setting in cement mortar 1:6 complete with joints to match complete all as specified.
M&L for 100 mm thick cement concrete type D-2 1:4:8 (using 40 mm graded stone aggregate), as in sub base for floor, finished even and rough complete all as specified and directed.
M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed
M&L for 60 mm thickness rubber moulded machine pressed precast concrete interlocking paver block M-35 any shape and size, confirming to IS 15658-2006 in grey cement glossy finish rubber mould casted laid dry over sand cushioning complete all as specified and directed.
Demolition of Brickwork or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
M&L for Brickwork with subclass 'B' bricks old size brick, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and directed.
Supply only liquid water proofing compound
M&L for 15 mm thick rendering in cement mortar (1:4) on brick / concrete/ stone surfaces mixed with water proofing compound as per manufacturer instruction, finished even and smooth using extra cement complete all as specified and as directed.
S&F in repair precast steel fiber reinforce concrete (SFRC) any colour 75-100mm thick manhole cover with frames (ISI marked) of overall covered area not exceeding 3.00 sqm with clear opening not less than 0.36 sqm any shape ( round, square, rectangular etc.) provided with suittable mild steel rims to prevent from chipping of edges and enable clear opening with are duly protected against corrosion laid over and including 10mm thick rendering in CM 1:4 complete all as specified and directed.
Taking down carefully existing aluminum / copper point wiring (light, fan, socket or power point) complete of any description including fitting such as switches, ceiling roses, pendants, tube light fitting, ceiling fan with regulators, sockets, wooden boards, laminated sheets from sunken boxes, boards, shades light fitting etc and making good the disturbed surfaces of walls, floors, ceiling etc to match with existing surfaces complete all as specified and directed.
Repair and maint of existing sunken slab:- (a) Dismantling of floor of WC and bath not exc 500mm deep and removing out the cinder/concrete from sunken portion, cleaning of RCC surface to remove dust, loose particle with compressed air or any other suitable method depending on site conditions, grinding any sharp edges etc complete all as specifeid and directed. (b) Cleaning or RCC surface to remove dust, loose particle etc with compressed air or any other particles or any other suitable techniques on site conditions etc. (c) M&L for a fibre glass reinforced cloth (300-500GSM) over acrylic modified cementitious coating system with base coat @ 1.50 Kg/Sqm glass fiber reinforcement and top coat with Sika Top (R) Seal-107 @ 1.50 Kg/sqm or equivalent of Fosroc or MC Bouchenie India Pvt Ltd. (d) M&L for protection plaster 15mm thick on cement mortar 1:3 admixed with appropriate integral water proofing compound with as specified. (e) M&L for providing 40mm dia GI pipe spout projecting at least 150mm beyond outer face of wall. (Paid Separately under respective item). (f) M&L for sunken portion filled with 1:5:10 Type E2 (40mm graded aggregate) and finished with 30mm thick PCC 1:2:4 type B0 (using 12.5mm stone aggregate) all as specified and directed. Note :- (i) The work will be executed by authorised manufacturers/applicator. (ii) The net floor area will be measure for payment purpose. (iii) Cost of the above aspect shall be deemed to be included in the quoted rates for this items and nothing extra shall be paid on this account.
Taking down ceiling fan of any sweep,removing blades, cleaning the fan completely of dust and dirt and Re-hanging the same back to its original positions including connecting with three core flexible copper wire to ceiling rose etc after the completion of the point wiring including replacement of old unserviceable fan hook rubber pad, nut bolts and washers etc, complete all as specified and as directed by Engr-in-charge.
Taking down submain wiring of any size any type and in any position metalic/non metallic PVC conduit of wooden batten complete all as specified and directed.
Taking down unserviceable Sheet metal box & MCB DB SPN with MCB's of any make/capacity, complete, all as specified and directed by Engr-In-Charge.
Taking down unserviceable TPN DB with MCB's of any make/capacity, complete, all as specified and directed by Engr-In-Charge.
M&L, concealed point wiring with PVC insulated and unsheathed electric cable 1100 volts grade single core FRLSH confirming to IS 694:2010 having multi stranded copper conductor of 1.5 Sqmm nominal cross sectional area (ISI marked with valid CML No) drawn in and including concealed non metallic rigid PVC conduit medium grade( ISI marked with valid CML No) not less than 20 mm dia with all fitting and fixing accessories and 1.5 Sqmm FRLSH confirming to IS 14930 (Part-I) 2001, PVC insulated unsheathed multistranded copper conductor cable as continuous earth conductor, connected to common earth dolly by providing suitable lugs with & including pressed steel sunken terminal boxes factory made for mounting switch, regulators etc with and including 2.8 mm thick plastic laminated sheet cover (white) ISI marked, fixed with brass screws and cup washers duly painted with two coats of anti corrosive paint/black bituminous paint outside and two coats of aluminium paint inside for mounting switches. sockets etc complete
One light point controlled by one switch.
One Ceiling fan point controlled by one switch.
One Exhaust fan point controlled by one switch.
One 5 pin multipurpose socket out let 5/6 Amps on the same board with other switch.
One 3 pin/5 pin switch socket outlet, 5 Amps on independent board.
One Bell/Buzzer point controlled by one way 5 Amp push button switch.
One light point controlled by 2- two way switch
Description all as per item No 6 here in before but point wiring with 2.5 sqmm FRLSH H confirming to IS 694:2010, multistrand copper conductor cable for one six pin socket outlet 15 Amps controlled by one switch on independent board and 2.5 sqmm FRLSH PVC insulated multi strand copper conductor cable as continous earth wire.
S&F Modular switch 1 way 6 A,1 module complete all as specified and directed.
S&F Modular Socket, 6A - 2/3 pin combined 2 module,complete all as specified and directed.
S&F Modular switch 1 way 16 A,1 module complete all as specified and directed.
S&F Modular Socket 6A/16A - 2/3 pin combined 2 module complete all as specified and directed.
S&F Modular switch 2 way ,6 A,1 module complete all as specified and directed.
S&F Modular ceiling rose surface bakelite 63.5 mm dia three terminal complete all as specified and directed.
S&F Modular Fan step regulator, 120W - 2 module 240 volts, AC 50Hz complete all as specified and directed.
S&F Buzzer Ding Dong, AC, 230 Volts, single pole complete all as specified and directed.
S&F Modular Bell push ,6A ,1 module complete all as specified and directed.
S&F Modular Lamp holder with metal ring, PVC/Polycarbonate type with back plate suitable for batten fittings ISI Marked complete.
S&F LED Lamp 09/10 watt complete with 5 star rating complete all as specified and directed.
M&L, sub main wiring with two single core PVC insulated unsheathed FRLSH confirming to IS 694:2010, multi stranded copper conductor (ISI marked with valid CML No), cable 1100 Volt grade, 4 sqmm size drawn in and including non metallic rigid PVC concealed conduit medium grade (ISI marked with valid CML No) not less than 25 mm dia with all fitting & fixing accessories including one run single core PVC insulated unsheathed 4 Sqmm FRLSH confirming to IS 14930 (Part-I) 2001, copper conductor (ISI marked with valid CML No) colour code as a earth continuity and connected upto DB complete all as specified and directed. (NOTE: (i) Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit and the quoted rates shall be deemed to be inclusive for cutting chases in wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface with putty to match with the existing surface.
M&L, sub main wiring with two single core PVC insulated unsheathed FRLSH confirming to IS 694:2010, multi stranded copper conductor (ISI marked with valid CML No), cable 1100 Volt grade, 6 sqmm size drawn in and including non metallic rigid PVC concealed conduit medium grade (ISI marked with valid CML No) not less than 25 mm dia with all fitting & fixing accessories including one run single core PVC insulated unsheathed 4 Sqmm FRLSH confirming to IS 14930 (Part-I) 2001, copper conductor (ISI marked with valid CML No) colour code as a earth continuity and connected upto DB complete all as specified and directed. (NOTE: (i) Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit and the quoted rates shall be deemed to be inclusive for cutting chases in wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface with putty to match with the existing surface.
S&F Decorative ultra slim LED Tubelight fitting of LED with extruded polycarbonate, enviormental friendly energy efficient ready to use, 20 watt,change colour with with three mode colure range 4000k to 6500K as per required fitting incluing reqd length of not less than 1.0 Sqmm PVC multistranded BIS marked 03/02 core copper conductor for electrical connection from ceiling rose to connector of LED fitting including testing on completion all as specified and directed.
S & F security light fittings better optics for uniform distribution IP 65 protection LED of 30 watt with Photometric sensor outdoor type 220-240 volt ambient light <5-15 lux working temparature -20~+40C working humidity <93% RH along with pvc connection of 6 to 10 amp capacity , Heat resistance glass, pressure die cast aluminium housing including 25mm dia galvanised iron pipe light grade bracket bent to shape over all length 0.60mtr fixed to wall with 02 Nos FI clamps made of 40 x 5 mm FI, 15 cm long, 8 mm dia bolts and nuts with washers grouted in wall complete including reqd length of 1.5 Sqmm PVC multistranded BIS marked, 03 core copper conductor for connection from ceiling rose to light fittings incl testing on completion all as specified and directed.
Supply, install, commissioning and installation of distribution meter box indoor type, factory made out of CRCA sheet 2mm thick complete with inside, outside powder coated independed housing for meters with transperent glass & rubber gasket packing with suitable size copper single/ two core wire for each control, cable gland, with 200 Amp rated TPN aluminium busbar (for outgoing) duly insulated (including self insulated) maintaining proper space for each busbar and grouting panel in wall etc complete including self closing locking arrangement and comprising for following fittings (i) MCCB TPN, 63 Amps ,16 KA - 01 No (For incoming) (ii) Amp Meter (0-100 Amp)- 01 Nos (iii) Volts Meter (0-500 Volts ) - 01 No (iv) Indicator Lamp set of three R,Y,B - 01 Set (v) ASS & VSS with CTs -02 Nos ( 01 Each) (vi) MCB SP 40 Amps, 230 volts - 04 Nos (For outgoing) (vii) Nutral bus bar link mounted on insulator (viii) Place for fixing the energy meter. - 04 Nos (ix) The quoted rate is inclusive of removing the existing electric meter from the building and re fixing the same in the sheet metal enclosure at the same location without any damage to the meter. Note;- (i) Cable entry gland made of polycarbonate of appropriated size shall be provided in each cable / wire entry as per IS standered. (ii) All internal wiring inside the panel used for metring purpose shall be PVC insulated FRLSH, ISI marked of size not less than 1.5 Sqmm.
S&F MCB DB, sheet metal enclosures double door SPN 12 way with bus bar 240 volts 2 in 1 shutter type (METAL DOOR) type with blanking plates where required and IP 43 degree protection complete all as specified and directed.
S&F, MCB SPN 40 to 63 Amps, 240 volts 'C' series 16 KA ,including connection with suitable size copper lugs complete all as specified and directed.
S&F, MCB SP 6 to 32 amp 240 volts, 40 Amps, 'C' series 10 KA including connection with suitable size copper lugs complete all as specified and directed.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories,copper winding, 230 V, 1400 mm sweep. Min air delivery 245 CFM with service value 6.00 BEE, 5 star rated with brushless direct current motor (BLDC) completion all as specified and directed.
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300m all as per specified and directed.
Supply & fix exhaust fans AC single phase 230/ 240 V of size 450 mm sweep copper winding with louve ,metal type completion all as specified and directed.
Supply and fix electric water heater,storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate,NRV, connection piece with PVC Connection of any make with(ISI Mark) having 10 mm dia, 60 cm long with steel reinforcement suitable for hot & cold water geyser outlet supply with 02 nos of unions/cup shaped cover with washers all as directed by engr-in-charge.
Supplying, laying, testing and commissioning of XLPE insulated screened PVC bedded galvanised steel strip or wire armured electric power cable (Heavy duty ) with aluminium conductor 1100 volts grade, cross sectional area size 35 Sqmm 3.5 Core.
Supplying and laying un reinforced precast concrete cable cover Class LV, Type I, flat size 250mm x 150mm x 40mm complete all as specified and directed.
S&F tube 'Light' grade galvanised with all fitting laid in trenches, fixed to wall and floor of 50 mm dia for cable protection complete all as specified and directed.
Supply and fix cable jointing kit for 1.1 KV grade cable for end joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 25 to 50 sqmm,Indoor/Outdoor type
Taking out old u/s pipe line alongwith fittings from existing connections of size 25 mm dia complete all as specifies and directed.
Taking out old u/s pipe line alongwith fittings from existing connections of size 20 mm dia complete all as specifies and directed.
M & L for GI pipe Med grade of 25 mm dia alongwith all fittings and fixtures complete laid in trenches all as specified and directed.
M & L for GI pipe Med grade of 20 mm dia alongwith all fittings and fixtures complete laid in trenches all as specified and directed.
S&F 25 mm PP-R Brass Gate Valve cofiorming to IS 14846/2000,ISI Mark MS Spindle and iron wheel head with both ends flanged with new rubber gasket,bolts and nuts including dismantling of old u/s Gate valve fixed at any location of size 25 mmm dia all as specified and directed.
S&F 20 mm PP-R Brass Gate Valve cofiorming to IS 14846/2000,ISI Mark MS Spindle and iron wheel head with both ends flanged with new rubber gasket,bolts and nuts including dismantling of old u/s Gate valve fixed at any location of size 20 mm dia all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) vertically, with top edge of plate not less than 1.5 metre below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 of MES Schedule Part-I connecting to earthing test. Testing on completion with and including necessary excavation and earth work in any type soil, earth lead connected to earth test point & to main switch board etc with & including adequate quantity of charcoal dust and common salt, test point, PCC (1:3:6) type C-1 (using 20mm graded BT stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, internal surface of concrete shall be given 10mm thick plaster in CM 1:4, pre cast RCC (1:2:4) type B-1 (using 20mm graded BT stone aggregate) 40mm thick cover, reinforced with 8mm dia deformed or TMT bars 3 Nos both way with 12 mm dia round bar handle, GI medium grade watering pipe 20 mm dia with funnel and wire mesh and 15mm dia GI medium grade earth lead protection pipe including provn of earth test point made of 50 x 5 mm MS Flat in 'D' shape 500 mm legth grouted in wall complete 01 x 6 mm multistrand PVC insulated copper conductor ( Green Colour) to be provided from test point to DB through 20 mm dia concealed non metallic conduit complete all as specified and directed as per MES Schedule Part I & II..
S&F for modular decorative plate and provising of new modular plate of different size including fixing ,the existing modular switchs , modular socket ,modular regulator and refixing them in new board
White cover plate with frame but 2/3/4 module
White cover plate with frame but 6/8/12 module
Arkay Instrumentation (BID ID -3514916)
M/s Himgiri construction (BID ID -3515178)
BEHL CONSTRUCTION CO (BID ID -3508682)
M/s. Ravi and brothers (BID ID -3515261)
M.S. ENGINEERS (BID ID -3515077)
M/S YOGANSH CONSTRUCTION CO. (BID ID -3515129)
SHRI RAM CONSTRUCTION (BID ID -3514087)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.31 MB
BOQ_830845.xls
BOQ • 0.37 MB
Tenderdocuments82.pdf
Tender Documents • 1.53 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .