Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹3.7 CrAccepted-AOC 14 CHAHAR CONSTRUCTION CO ADARSH NAGAR NEAR ROHILLA COMMUNICATION 124103 | JHAJJAR | HARYANA | 124103 | ₹3.7 Cr Quoted ₹3.8 Cr | L-1 | Accepted-AOC Awarded |
| 2 | L-2₹4.0 CrRejected-AOC 28 29 GALI NO 05 MAHABIR PARK 124507 | BAHADURGARH | JHAJJAR | HARYANA | 124507 | ₹4.0 Cr | L-2 | Rejected-AOC Not awarded |
| Sl No | Description | Qty | Unit | Chahar Construction Co L1 | Suresh Kumar L2 |
|---|---|---|---|---|---|
| 1.00 | NON CLOG SEWAGE PUMP : Supplying, erection, testing and commissioning of Submersible motor pumping set non clog for sewerage having head below mentioned as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked. ( 10200 LPM x 20 .00 M Head x 75.00 BHP) | 1 | Each | 8,51,360 ₹8.5 L | 7,82,500 ₹7.8 L |
| 2.00 | NS Item - PANEL BOARDS FOR MOTOR:- Supply Erection,Testing and Commissioning of wall mounted electrical LT Panel board ,
fabricated from SWG CRCA sheet duly stoten with suitable angle iron frame work and completely powder coated of suitable size deep
having following item for 1 Non clog submercible pumping) START DELTA STARTER :- 1.Main MCCB(ABB/LandT/SCHNEIDER -
01nos 2. Controlling MCB - 01nos 3.THERMAL OVER LOAD RELAY (ABB/LandT/SCHNEIDER) - 01 nos 4. AUXILARY
CONTACTOR (ABB/LandT/SCHNEIDER) - 03 nos 5.START/STOP PUSH BUTTON(SCHNEIDER/SALZAR/SEIMENS)
6.EMERGENCY SWITCH(SCHNEIDER/SALZAR/SEIMENS) - 01 nos 7.DIGITAL VAF METER(SECURE/SELEC/TECHNO/ABB) - 01
nos 8.CT RATIO - 100/5 (AE/KAPPA/LandT) - 01 nos 9. CAPACITOR BANK AS PER LOAD REQUIREMENT 10. CHANGE OVER
SWITCH AS PER LOAD(SCHNEIDER/SALZAR/SEIMENS) - 01 nos 11.SELECTOR SWITCH(SECURE/SELEC/TECHNO/ABB) - 01
nos 12. SINGLE PHASE PREVENTER(SECURE/SELEC/TECHNO/ABB) -01 nos 13.ELCB BREAKER(ABB/LandT/SCHNEIDER)
14.10200 LPM 20 mtr HEAD (75 BHP ) | 1 | Each | 4,08,000 ₹4.1 L | 4,00,000 ₹4 L |
| 3.00 | Provision for providing and fixing of M.S Sluice Gate complete in all respect. | 11.16 | Sqm | 54,400 ₹6.1 L | 1,20,000 ₹13.4 L |
| 4.00 | HT Panel -Supply Indoor Type 11KV VCB
Control Cubical Panel with vertical Isolation Type Breaker as
per Relevant IS as amended up to Date and Additional
Specifications, having Capacities as Mentioned Below, Single
break trip free mechanism, manually charged and
Auto/Manually closing breaker suitable for use on 11kv, 3
phase 50hz AC, Supply with short circuit fault level of 500
Amps Capacity, breaker featured with local ON/OFF indicator
with hand trip device, spring release coil, shunt trip coil and
auxiliary switch of 2NO plus 2NC and equipped with following
switchgears and accessories including making suitable
structure arrangement for installation, control wiring and
connections etc. as reqd. (1 IC plus 2 OG)
a). VCB, 11KV, 630Amp, 50KA.
b). 1ph 11KV/110 Volts PT (indoor type) Class 0.2 Accuracy
and 100 VA burden -3 no’s.
c). 33KV indoor dead type dual core dual ratio 3CTs of ratio
200-100/5-5 A of 15 VA burden, PS 5 P10 and accuracy class
0.2.
d). Control panel- Cubicle type control panel suitable for floor
mounting made out of 1.63 mm CR sheet duly powder coated
and with following relays.
e). Microprocessor based numerical relay for O/L, E/F and SC
Protection suitable for above.
f). Master trip relay -2 no’s.
g). Indicator type Annunciator panel with buzzer.
h). Digital Volt Meter- 0-11 KV.
i). Digital Amp Meter- 0-100 Amp.
j). RYB/ Trip/Closing/Spring charged indicator lamp.
k). Fault Annunciator panel for O/L, WTI, OTI and Buchhloz
Relay Alarm And Trip Auxiliary relay.
l) TNC Switch for Operation.
m)Multifunction Meter EM6400NG.
n)TCS Relay for Safety. | 1 | Job | 13,05,600 ₹13.1 L | 12,00,000 ₹12 L |
| 5.00 | LT COPPER CABLE FOR LT PANEL TO PUMP
SET (at Disposal)
50 sqmm * 3C * 1 Run, 1100 V Grade Multi Strand flexible
annealed copper conductor, PVC Insulated and sheathed
Multi - core flexible cables. Plain annealed high conductivity
flexible copper conductor as per Class 5 of IS 8130/2013,
latest, PVC TYPE D as per IS 5831/1984, Latest, Extruded
PVC Type ST3 as per IS 5831/1984, Latest, IS 8130/2013, IS
5831/1984, IS 694/2010, etc. with latest up to date updates,
As per IEC 60332-1-2. | 45 | Per Mtr | 1,306 ₹58,770 | 2,500 ₹1.1 L |
| 6.00 | NS Item -Providing and installation of HT ALUMINUM
POWER CABLE 6.35KV/11KV Voltage grade, 3-core
Stranded, compact circular shaped Aluminum Conductor of
H4 grade, Water Tree free XLPE Insulated, PVC sheathed, GI
round wire armoured, Longitudinal and radial watertight power
cables, confirming to IS: 7098(Part-II), IEC-60502-2 1998,
IS5819, IS-3961, IS-8130, IS-3975, IS-4759, IS-5831 and as
per the technical specifications herewith attach IS code..( HT 2x95 sqm HT Panel to transformer) ( HT meter to HT Panel, HT Panel to transformer ) at Disposal | 140 | Per Mtr | 3,700 ₹5.2 L | 4,500 ₹6.3 L |
| 7.00 | HT. ALLUMINUM CABLE: Supply erection testing of standard make XLPE 3 core HT/ 11 KV grade ISI marked standard compact circular aluminium conductor, conductor screen with extruded semi conducting compound, XLPE insulated, insulation screening with extruded semi conducting compound in combination with copper tape, cores laid up, and innersheath of pvc sheathed cable
conforming to is 7098 (part-2) 2011 with up to data amendaments for making following connection a) from G.O switch to metering equipment. B) from metering equipment to transformer complete in all respect. Make: Finolex/ havells/RR Cable. (35 sqmm size). | 40 | Per Mtr | 3,700 ₹1.5 L | 5,000 ₹2 L |
| 8.00 | NS Item - PANEL BOARDS FOR MOTOR:- Supply Erection,Testing and Commissioning of wall mounted electrical LT Panel board ,
fabricated from SWG CRCA sheet duly stoten with suitable angle iron frame work and completely powder coated of suitable size
deep having following item for 1 Non clog submercible pumping)
START DELTA STARTER :-
1.Main MCCB(ABB/LandT/SCHNEIDER - 01nos
2. Controlling MCB - 01nos
3.THERMAL OVER LOAD RELAY (ABB/LandT/SCHNEIDER) - 01 nos
4. AUXILARY CONTACTOR (ABB/LandT/SCHNEIDER) - 03 nos
5.START/STOP PUSH BUTTON(SCHNEIDER/SALZAR/SEIMENS)
6.EMERGENCY SWITCH(SCHNEIDER/SALZAR/SEIMENS) - 01 nos
7.DIGITAL VAF METER(SECURE/SELEC/TECHNO/ABB) - 01 nos
8.CT RATIO - 100/5 (AE/KAPPA/LandT) - 01 nos
9. CAPACITOR BANK AS PER LOAD REQUIREMENT
10. CHANGE OVER SWITCH AS PER LOAD(SCHNEIDER/SALZAR/SEIMENS) - 01 nos
11.SELECTOR SWITCH(SECURE/SELEC/TECHNO/ABB) - 01 nos
12. SINGLE PHASE PREVENTER(SECURE/SELEC/TECHNO/ABB) -01 nos
13.ELCB BREAKER(ABB/LandT/SCHNEIDER)
14.6400 LPM 30 mtr HEAD (75 BHP ) | 3 | Each | 4,08,000 ₹12.2 L | 3,75,000 ₹11.3 L |
| 9.00 | Supplying, erection, testing and commissioning of Submersible motor pumping set non clog for sewerage having head 30.00 m as per the indicated requirements of discharge in LPM 6400 as per specification and make of approved NIT. | 3 | Each | 6,52,800 ₹19.6 L | 7,00,000 ₹21 L |
| 10.00 | HT Panel -Supply Indoor Type 11KV VCB
Control Cubical Panel with vertical Isolation Type Breaker as
per Relevant IS as amended up to Date and Additional
Specifications, having Capacities as Mentioned Below, Single
break trip free mechanism, manually charged and
Auto/Manually closing breaker suitable for use on 11kv, 3
phase 50hz AC, Supply with short circuit fault level of 500
Amps Capacity, breaker featured with local ON/OFF indicator
with hand trip device, spring release coil, shunt trip coil and
auxiliary switch of 2NO plus 2NC and equipped with following
switchgears and accessories including making suitable
structure arrangement for installation, control wiring and
connections etc. as reqd. (1 IC plus 2 OG)
a). VCB, 11KV, 630Amp, 50KA.
b). 1ph 11KV/110 Volts PT (indoor type) Class 0.2 Accuracy
and 100 VA burden -3 no’s.
c). 33KV indoor dead type dual core dual ratio 3CTs of ratio
200-100/5-5 A of 15 VA burden, PS 5 P10 and accuracy class
0.2.
d). Control panel- Cubicle type control panel suitable for floor
mounting made out of 1.63 mm CR sheet duly powder coated
and with following relays.
e). Microprocessor based numerical relay for O/L, E/F and SC
Protection suitable for above.
f). Master trip relay -2 no’s.
g). Indicator type Annunciator panel with buzzer.
h). Digital Volt Meter- 0-11 KV.
i). Digital Amp Meter- 0-100 Amp.
j). RYB/ Trip/Closing/Spring charged indicator lamp.
k). Fault Annunciator panel for O/L, WTI, OTI and Buchhloz
Relay Alarm And Trip Auxiliary relay.
l) TNC Switch for Operation.
m)Multifunction Meter EM6400NG.
n)TCS Relay for Safety. | 1 | Job | 13,05,600 ₹13.1 L | 12,00,000 ₹12 L |
Tender Value
₹3.5 Cr
EMD Value
₹6.9 L
Closing Date
16 Feb 2026, 1:00 pmClosed
ASHWANI SANGWAN
Jhajjar PHED No. 3
Construction of 2 Nos. Disposal , Laying of Storm Water Lines and Construction of Manholes
2026_HRY_500848_1
20262736EAE7 F9AC 4137 A25B 379DFFF68A35592PUH
Open Tender
Civil Works
365 days
Jhajjar
2 documents required · 2 mandatory
₹15,000
₹6.9 L
Yes
2 Apr 2026
5 Feb 2026
16 Feb 2026
5 Feb 2026
16 Feb 2026
5 Feb 2026
NON CLOG SEWAGE PUMP : Supplying, erection, testing and commissioning of Submersible motor pumping set non clog for sewerage having head below mentioned as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked. ( 10200 LPM x 20 .00 M Head x 75.00 BHP)
Provision for providing and fixing of M.S Sluice Gate complete in all respect.
HT Panel -Supply Indoor Type 11KV VCB Control Cubical Panel with vertical Isolation Type Breaker as per Relevant IS as amended up to Date and Additional Specifications, having Capacities as Mentioned Below, Single break trip free mechanism, manually charged and Auto/Manually closing breaker suitable for use on 11kv, 3 phase 50hz AC, Supply with short circuit fault level of 500 Amps Capacity, breaker featured with local ON/OFF indicator with hand trip device, spring release coil, shunt trip coil and auxiliary switch of 2NO plus 2NC and equipped with following switchgears and accessories including making suitable structure arrangement for installation, control wiring and connections etc. as reqd. (1 IC plus 2 OG) a). VCB, 11KV, 630Amp, 50KA. b). 1ph 11KV/110 Volts PT (indoor type) Class 0.2 Accuracy and 100 VA burden -3 no’s. c). 33KV indoor dead type dual core dual ratio 3CTs of ratio 200-100/5-5 A of 15 VA burden, PS 5 P10 and accuracy class 0.2. d). Control panel- Cubicle type control panel suitable for floor mounting made out of 1.63 mm CR sheet duly powder coated and with following relays. e). Microprocessor based numerical relay for O/L, E/F and SC Protection suitable for above. f). Master trip relay -2 no’s. g). Indicator type Annunciator panel with buzzer. h). Digital Volt Meter- 0-11 KV. i). Digital Amp Meter- 0-100 Amp. j). RYB/ Trip/Closing/Spring charged indicator lamp. k). Fault Annunciator panel for O/L, WTI, OTI and Buchhloz Relay Alarm And Trip Auxiliary relay. l) TNC Switch for Operation. m)Multifunction Meter EM6400NG. n)TCS Relay for Safety.
LT COPPER CABLE FOR LT PANEL TO PUMP SET (at Disposal) 50 sqmm * 3C * 1 Run, 1100 V Grade Multi Strand flexible annealed copper conductor, PVC Insulated and sheathed Multi - core flexible cables. Plain annealed high conductivity flexible copper conductor as per Class 5 of IS 8130/2013, latest, PVC TYPE D as per IS 5831/1984, Latest, Extruded PVC Type ST3 as per IS 5831/1984, Latest, IS 8130/2013, IS 5831/1984, IS 694/2010, etc. with latest up to date updates, As per IEC 60332-1-2.
NS Item -Providing and installation of HT ALUMINUM POWER CABLE 6.35KV/11KV Voltage grade, 3-core Stranded, compact circular shaped Aluminum Conductor of H4 grade, Water Tree free XLPE Insulated, PVC sheathed, GI round wire armoured, Longitudinal and radial watertight power cables, confirming to IS: 7098(Part-II), IEC-60502-2 1998, IS5819, IS-3961, IS-8130, IS-3975, IS-4759, IS-5831 and as per the technical specifications herewith attach IS code..( HT 2x95 sqm HT Panel to transformer) ( HT meter to HT Panel, HT Panel to transformer ) at Disposal
HT. ALLUMINUM CABLE: Supply erection testing of standard make XLPE 3 core HT/ 11 KV grade ISI marked standard compact circular aluminium conductor, conductor screen with extruded semi conducting compound, XLPE insulated, insulation screening with extruded semi conducting compound in combination with copper tape, cores laid up, and innersheath of pvc sheathed cable conforming to is 7098 (part-2) 2011 with up to data amendaments for making following connection a) from G.O switch to metering equipment. B) from metering equipment to transformer complete in all respect. Make: Finolex/ havells/RR Cable. (35 sqmm size).
Supplying, erection, testing and commissioning of Submersible motor pumping set non clog for sewerage having head 30.00 m as per the indicated requirements of discharge in LPM 6400 as per specification and make of approved NIT.
HT Panel -Supply Indoor Type 11KV VCB Control Cubical Panel with vertical Isolation Type Breaker as per Relevant IS as amended up to Date and Additional Specifications, having Capacities as Mentioned Below, Single break trip free mechanism, manually charged and Auto/Manually closing breaker suitable for use on 11kv, 3 phase 50hz AC, Supply with short circuit fault level of 500 Amps Capacity, breaker featured with local ON/OFF indicator with hand trip device, spring release coil, shunt trip coil and auxiliary switch of 2NO plus 2NC and equipped with following switchgears and accessories including making suitable structure arrangement for installation, control wiring and connections etc. as reqd. (1 IC plus 2 OG) a). VCB, 11KV, 630Amp, 50KA. b). 1ph 11KV/110 Volts PT (indoor type) Class 0.2 Accuracy and 100 VA burden -3 no’s. c). 33KV indoor dead type dual core dual ratio 3CTs of ratio 200-100/5-5 A of 15 VA burden, PS 5 P10 and accuracy class 0.2. d). Control panel- Cubicle type control panel suitable for floor mounting made out of 1.63 mm CR sheet duly powder coated and with following relays. e). Microprocessor based numerical relay for O/L, E/F and SC Protection suitable for above. f). Master trip relay -2 no’s. g). Indicator type Annunciator panel with buzzer. h). Digital Volt Meter- 0-11 KV. i). Digital Amp Meter- 0-100 Amp. j). RYB/ Trip/Closing/Spring charged indicator lamp. k). Fault Annunciator panel for O/L, WTI, OTI and Buchhloz Relay Alarm And Trip Auxiliary relay. l) TNC Switch for Operation. m)Multifunction Meter EM6400NG. n)TCS Relay for Safety.
LT ALUMINUM POWER CABLE: Power cable A2XFY MC-3, Stranded compacted aluminum conductor, XLPE insulated, PVC inner sheathed, Galvanised Steel Flat strip armoured and PVC sheathed confirming to IS 7098 1,IS3961, IS 8130-1984, IS-3975, 1999, IS-4759, IS-5831, IS10418, IS-10810 is suitable for AC single phase or three phase (earthed or unearthed) systems with rated voltage up to and including 1100 V. This cable is also suitable for DC systems with rated voltage up to and including 1500 V to earth. (240 sqmm X 3.5 core
LT COPPER CABLE FOR LT PANEL TO PUMP SET (at Disposal) 50 sqmm * 3C * 1 Run, 1100 V Grade Multi Strand flexible annealed copper conductor, PVC Insulated and sheathed Multi - core flexible cables. Plain annealed high conductivity flexible copper conductor as per Class 5 of IS 8130/2013, latest, PVC TYPE D as per IS 5831/1984, Latest, Extruded PVC Type ST3 as per IS 5831/1984, Latest, IS 8130/2013, IS 5831/1984, IS 694/2010, etc. with latest up to date updates, As per IEC 60332-1-2.
HT. ALLUMINUM CABLE: Supply erection testing of standard make XLPE 3 core HT/ 11 KV grade ISI marked standard compact circular aluminium conductor, conductor screen with extruded semi conducting compound, XLPE insulated, insulation screening with extruded semi conducting compound in combination with copper tape, cores laid up, and innersheath of pvc sheathed cable conforming to is 7098 (part-2) 2011 with up to data amendaments for making following connection a) from G.O switch to metering equipment. B) from metering equipment to transformer complete in all respect. Make: Finolex/ havells/RR Cable. (35 sqmm size)...
Supplying, erection, testing and commissioning of Submersible motor pumping set non clog for sewerage having head 20.00 m as per the indicated requirements of discharge in LPM 6800 as per specification and make of approved NIT.
Provision for providing and fixing of M.S Sluice Gate of size 1.755 x 2.435 Mtr. complete in all respect.
Providing and fixing of clamp and MS stage including bolts and nuts for 100 mm pipe.
GI special/ GI Elbow providing and fixing GI Elbow complete in all respect.
GI special/ GI Nippal providing and fixing GI Nippal 15 mm x 150 mm / 100 mm complete in all respect
Providing and fixing GI Socket complete in all respect.
Percentage BoQ
BoQ_Ver3.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
HSR Itmes
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.77 MB
BOQ_579460.xls
BOQ • 0.35 MB
OT0149010.pdf
Other Document • 7.70 MB
Download all tender documents and submit your bid