Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.0 LAccepted-AOC VPO TEHSIL JAWALI DISTT KANGRA HP | KANGRA | HIMACHAL PRADESH | 175013 | L1 | Accepted-AOC .. | |
| 2 | L2₹46.1 L+₹5.1 L (12.5%)Rejected-AOC | L2 | Rejected-AOC .. | |
| 3 | L3₹46.2 L+₹5.3 L (12.9%)Rejected-AOC R O SUJANPUR TEHSIL DISTT HAMRIPUR | L3 | Rejected-AOC .. | |
| 4 | L4₹46.5 L+₹5.5 L (13.5%)Rejected-AOC | L4 | Rejected-AOC .. | |
| 5 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹65.1 L
EMD Value
₹97,598
Closing Date
21 Mar 2024, 11:00 amClosed
Executive Engineer JSV Division Hamirpur
Executive Engineer JSV Division Hamirpur
Sub Head Providing and laying Rising main GMSERW 65mm dia pipe percolation well to main storage tank at Village Tikker and Supply and errection of Submersible pumping machinery
2024_HPIPH_88318_1
JS-HMR-CB-Misc.Agr/2022-23
Open Tender
Civil Works
Item Rate
180 days
Executive Engineer JSV Division Hamirpur
Please refer Tender documents.
8 documents required · 8 mandatory
₹800
Executive Engineer JSV Division Hamirpur
₹97,598
Yes
13 May 2025
12 Mar 2024
21 Mar 2024
12 Mar 2024
21 Mar 2024
12 Mar 2024
Amount
Excavation in foundations and trenches (for pipes and pits for other civil structures) upto all depths in all kinds of soil such as pick work, jumper work and saturated soil and paved surfaces including bailing or pumping out of water, chiseling or wedging out of same where blasting is prohibited in all leads and lifts including trimming and dressing of sides, leveling of beds to correct grade including shoring, strutting, planking timbering and dewatering wherever required, stacking usable and unusable material/soil separately and after laying jointing and testing of pipes, returning the usable soil in 15 cm layer by ramming and watering and then disposing of all surplus excavated soil/unusable material as directed within all leads and lifts including cost of diversion of traffic, night signal boards, fixing caution boards, crossing over trenches for access to houses, fencing etc. complete in all respects as per the direction of Engineer-in-charge. Pick Jumer work
Providing, laying, jointing, testing & commissioning at site in trenches beveled ended BIS marked MSERW pipes of various grade conforming to IS/ISO-3183-2007 of steel grade L210 or A or its equivalent specifications latest with upto date amendments of following dia with upto date amendments having wall thickness and per Rmt weight as mentioned below & capable of withstanding required test pressure as prescribed in BIS code in random lengths of 6 to 7 mtr. The pipes ends shall be beveled suitable for butt welding including the cost of jointing with butt welding conforming to IS 816-1969 or latest as applicable ends with upto date amendments (leak proof) in three layers at site of work with welding rods of standard make and all allied accessories whatever required for welding at site, tail pieces, tees, bends and other specials manufactured from parent pipes as applicable to the particular reach & of approved specification as per site conditions and cutting of pipes wherever required as per site requirement including carriage in all leads and lifts and as directed by Engineer-in-charge. The pipe shall haves zinc coating inside & out side conforming to IS/ISO-4736-1986 or latest with upto date amendments & shall be engraved with code IS/ISO-3183-2007 or its equivalent and the pipe shall be galvanized at the same factory premises of MS pipe manufacturer. The laying shall conform to BIS 5822-1970 or latest with upto date amendments with provision of scour pipe after every km by providing Tee & Sluice valve etc.complete in all respect with carriage in all leads & lifts and to the entire satisfaction of Engineer-in-Charge (Earth work ,flanged joints & butt welded joints shall be measured and paid for separately).
65mm dia
Providing and welding MS flanges @ 5% of total length and 95% for butt weld of total length conforming to following tables as per IS 6392-1971 (Last with upto date amendments) with plan and G.I pipe in requsite number of layers on both faces to make the joint leak proof (The cost of providing and laying of GI pipes to be measured and paid for separately). The welding of flanges should conform to IS 816-1969 with electrodes as per IS: 814-1991 and required number of nuts and bolts conforming to IS 1364. including cost of gas ket sheet not less then 3.00 mm conforming to IS 2712-1998. The work shall be done tothe entire satisfaction of engineer in charge within all leads and lifts.
M.S Flanges 65 mm dia. table -28
M.S Flanges 65 mm dia. table -17
Providing Circumferencial Butt welded joints to following diameter and class of G.I.pipe as specified above, welded with 3-5 layers of welding (According to wall thickness of pipe ) by using 3mm to 4mm special electrodes of Advani oreion (Adore)/ ESAB make with Generator and winch and crab/ loader at site .( The cost of providing and laying of G.I. pipe and flanged joints to be measured and paid for separatly). The welding of flanges should confirm to IS 816-1965 with electrodes as per IS: 814-1967. The work shall be done as per entire satisfaction of Enginneer-in- charge with in all leads and lifts.
65mm dia
Providing & fixing double flanged C.S Non return valve of 65 mm dia Leader/Kirloskar make to rising main confirm -ng to BS:1868-API-6D as per class given below and capable of with standing 52.00 Kg/cm2 seat pressure with upto date ammendments.
65mm dia ASA 300
Providing & fixing screwed Cast Steel Air release valve 25mm dia single ball type Leader/Kirloskar make confirming to BS 1452-90 with upto date ammendments as per class -150 to with stand a seat pressure of 11.22 Kg/cm2.
BOOSTER STAGE FROM PERCOLATION WELL :-
Supply & Errection of horizontal spindle, vertical split casing Single/Multistage Submersible pumps of standard make such as KSB / Kirloskar / Johnston / Calama / Worthington conforming to BIS 8034-1976 (latest with upto date ammendments) to handle raw water with impellers, casing, ring & shaft sleeves of bronze, shaft of steel with cast iron casing of suitable capacity coupled directly through a flexible coupling on a common base plate to Kirloskar / NGEF / Crompton /Siemen /Jyoti / ABB /Morthon Slipring / squirrel cage screen protected drip proof induction eletric motor suitable for operation on the data given below :-
Discharge (Q) 3.20 LPS for each pump.
Total head in Mts. 223.01 meters
(a) LWL in sump well (h) 594.50 mtrs.
(b) Shaft level 593.50 mtrs.
(c ) Level at discharge point 712.00 mtrs.
(d) Suction lift 3 mtrs.
(e) Residual head 3 mtrs.
(f) Static head 119.00 mtrs.
Rising main
(a) Length 3150 mtrs.
(b) dia 65 mm
Pumping hours 3 hours
Altitude of installation above MSL 591 mtrs.
Characterstics of water
(a) Temperature 25 degree centigrade
(b) Abient Temp.
( c) Turbidity up to 100 PPM
(d) Alkalanity
(e) Size of the solids
(f) Other
Operating Rage (+) 10% and (-) 15% of the duty head.
Supplying and fixing of prefabricated control panel consisting of Ampere Meter, Voltmeter, MCB/MCCB, ON/OFF push button, Circuit breaker, Voltage monitor relay, Power factor meter, Frequency meter, Bus bar chamber, Change Over Switch/ ICTP main switch with HRC fuses and other accessories, Capacitor, Strarter (Fully automatic air break star delta starter), Phase Preventor, Hour run meter and other accessories suitable for pumping machinery under item No. 1 as per following technical specification :- 1 Job
(i) M S sheet 16 SWG steel fabricated floor mounted closed almirah type switch board including angle iron post of suitable height and size ISA 40x40x6mm duly painted comprising and capable of mounting the following accessories with all internal electric connections. The drawing of panel board shall be subject to approval of Engineer in charge. = 1 No.
(ii) ICTP switches with HRC fuses / Change Over Switch of Havells /Standard / Indoasian / L&T make and having capacity 30% extra of the operational rating of motor as per BIS 4064-1978 with upto date amendments immediately after the power meter of HPSEB. = 1 Set
(iii) Digital VAF (Volt-Ampere-Frequancy) meter (0 - 500) Volt, (0 - 500) Ampare as per standard make latest with upto date amendments. = 2 Nos.
(iv) Busbar chamber having 3 copper bars of suitable rating for full length equal to width of board of 3 live phases and one copper bar of half rating of full length for neutral conforming to BIS 8084-1976 and 11353-1985 read with 5578-1985 all latest with upto date amendments. = 1 Set
(v) MCB/MCCB of suitable capacity of ABB / L&T / Havells / Standard / Indoasian make on in comming feeder for motors offered by the tenderer conforming to BIS 2516-1985 latest with upto date amendments with neutral linked under voltage release. = 1 No.
(vi) 3 phase indicating lamps complete with toggle switches for individual motors conforming to BIS 3452 part I & II latest with up to date amendments. = 2 Nos.
(vii) Earth leakage circuit breaker of recomended make such as Standard / Havell's as per BIS-2516-1977 with upto date ammendments and of suitable range with which should have control box, operating handle and trip / reset bush button on / off indicators, re-indicating off spring condition of the circuit breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tap CTS. It should also be fitted earth fault for tripping of breaker on occurance of earth fault on/ off breaker load side. = 1 No.
(viii) Hour run meter of reputed make of four digit capacity conforming to BIS-722 (latest edition)/recommendations. = 1 Nos.
(ix) Suitable three phase voltage monitor relay with all protections & usual indicators with electrical sirens against single phasing, no voltage, high voltage & overloading & phase voltage difference = 1 No.
(x) Strarter (Direct on line/ Fully Automatic Star delta /Auto transformer) of make Havells / L&T /ABB / Schneider of suitable capacity = 2 Nos.
(xi) In built of separate Single phase preventor of Standard/Havells/Indoasian make make & suitable capacity = 1 No.
(xii) Supply & errection of floor/wall mounted power shunt capacitor conforming to BIS 2834-1986 latest with upto date ammendments of GEC/Siemen/ Havells L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually of requirement KVAR according to BHP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including Standard/ L&T/Kilburn/Indo asian make ICTP switches conforming to BIS 4064- 4064-1978 or latest with HRC fuses. (Range to be specified by the tenderer.) ( ) KVAr = 2 Nos.
Supplying and fixing of Kirloskar / Leader/ of reputed make of cast iron flanged foot valve confirming IS 4038-19864 , size equal to dia of suction pipe i.e 65 mm dia, 10.20 Kg/Cm2 Class PN 1.0. 2 Nos
Supplying and fixing of Kirloskar / Leader / Pelcom / KSB of reputed make of cast steel double flanged sluice valve confirming to BIS 1414 (with latest upto date ammendments) having size one step higher to delivery of pump and capable of with standing nominal seat pressure of 52.00 Kg/Cm2 Class ASA-300 2 Nos
Supplying and fixing of Kirloskar / Leader of suitable size cast steel double flanged swing check type reflux valve having bye pass arrangement & size one step higher to delivery of pump confirming to BIS 1868 (with latest upto date ammendments) for withstanding nominal seat pressure of 52.00 Kg/Cm2 Class ASA-300. 2 Nos
Supplying and fixing of Kirloskar / Leader of suitable size cast steel double flanged swing check type reflux valve having bye pass arrangement & size equal to dia of R/main ie is 65 mm confirming to BIS 1868 (with latest upto date ammendments) for withstanding nominal seat pressure of 52.00 Kg/Cm2 Class ASA-300. 1 Nos
Providing & laying PVC insulated jointless, flat water proof copper cable of Siemens /Finolex /Grandlay /Gloster make conforming to BIS:1554 (Part I) -1988 or latest with up to date ammendments of suitable size for the pump sets offered(one cable carrying all three phases) including all other electrical equipment /accessories such as thimbles,flexible pipe, solder, nuts & bolts cable glands etc. laid in pipes or trenches under floor. The type,size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
a) On supply side of 3½ core coper cable 4 mm^2 ( From HPSEB Meter to Switch & Starter). 5 Mtrs
b) On motor side 3 core flat joint less copper cable of size 6.00 mm^2 ( From Switch & Starter to Motor) pump installed in the bore. 30 Mtrs
Supply of standarad make 80 mm dia circular/square dial pressure gauge of suitable range Fiebeg / Bourden / Precision make with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 latest with up to date ammendments. 2 Nos
P/L/J G.I./MSERW pipe considering site requirements and having appropriate size in accordance with the delivery size of pumping set . The pipe shall conform to relevant BIS codes & capable of with standing the feild test pressure equal to 1.5 times the operating pressure including all type of fittings such as bends, tapers/ reducers, flanges, rubber gaskets 3mmthick, nuts & bolts and any other fitting required at site and work shall be to the entire satisfaction of Engineer-in-Charge. The pipe material shall conform to relevant BIS Code and capable of with standing FTP equal to 1.5 times the operating pressure the complete arrangement shall compromise of 1 Job
a) Suction Pipe 65 mm dia flanged with F.T.-5 = to be specified by the Tenderer
b) Delivery pipe 50 mm dia flanged with F.T.-28 = to be specified by the Tenderer
c) Common header = 65 mm dia
NOTE:- Actual laying to be done as per final drawings to be approved by the Engineer in charge
Providing and fixing double loop earth with copper plate 600mmx600x3mm thick electrode complete with material such thimbles nuts and charcoal and common salt, 25mmx5mm copper strips as per IS:3043:1987 with upto date ammendments for motors and other electrical equipments and digging of pits etc. complete in all respect. 1 Job
Installation of all the above items S. No. 8 to 17 complete in all respect to the entire satisfaction of the Engineer-in-charge. 1 Job
SUNIL VERMA
RAJE ENGINNERING WORKS
Raman Thakur Govt. Cont.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .