Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.5 LAccepted-AOC | ₹23.5 L Quoted ₹25.5 L | L1 | Accepted-AOC Lowest |
| 2 | L2₹28.5 L+₹3.0 L (11.6%)Rejected-Finance 93 SARASWATI PURAM COLONY SG PGI LUCKNOW UP 226 014 | LUCKNOW | LUCKNOW | UP | 226014 | ₹28.5 L+₹3.0 L (11.6%) | L2 | Rejected-Finance OTHER THAN LOWEST |
| 3 | L3₹30.6 L+₹5.1 L (19.8%)Rejected-Finance MOH HATHITHAN NIGOHI ROAD SHAHJANPUR UP 242001 | SHAHJAHANPUR | UTTAR PRADESH | 242001 | ₹30.6 L+₹5.1 L (19.8%) | L3 | Rejected-Finance OTHER THAN LOWEST |
| 4 | L4₹42.0 L+₹16.5 L (64.6%)Rejected-Finance 44 NEAR DURGA MANDIR TRIPURI TOABA TRIPURI TOWN PATIALA 147004 PB | PATIALA | PUNJAB | 147004 | ₹42.0 L+₹16.5 L (64.6%) | L4 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹37 L
EMD Value
₹74,000
Closing Date
19 Jul 2024, 6:00 pmClosed
GE (WEST) LUCKNOW
GE (WEST) LUCKNOW PIN 226002 C/O 56 APO
REPAIR/ OVERHAULING OF CEILING FAN/ EXHAUST FAN/ WALL FAN/ COOLER AND SOLAR WATER HEATER GEYSER AND ALLIED WORKS UNDER GE(WEST) LUCKNOW
2024_MES_661345_1
GE/W/LKO/56 OF 2024-25
Open Tender
Civil Works
Item Rate
330 days
LUCKNOW
AS PER NIT AND TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE (WEST) LUCKNOW
₹74,000
Yes
7 Nov 2024
21 Jun 2024
26 Jul 2024
21 Jun 2024
19 Jul 2024
5 Jul 2024
21 Jun 2024 - 28 Jun 2024
Amount
Comprehensive repair/maintenance of storage type electric water heater (geyser) of capacity 50 litres, vertical or horizontal type comprising of the following: (a) Opening or dismantling the storage tank, taking down, de-scaling, brushing and thoroughly cleaning. (b) checking of all stop cock, pressure release valves, fusible plugs for its serviceability etc. in situ to ensure proper functioning of parts including supply and replacing of washers/ gasket nut etc. (c) Checking and rectify earth continuity of the Electrical circuits of Geyser and power point. (d) Checking and re-fixing thermostat and re-adjust. (e) De-scaling the immersion type heating element and siphon assembly with diluted Hydrochloric acid or clear pedette solution. (f) Checking of indicator lamp for it proper serviceability. (g) Re-assembling the Geyser and re-install at same position and testing complete all as specified and as directed. Note :- (i) Unserviceable Parts/ components of electric water heater shall be replaced by the contractor. (ii) Supply of new parts/components shall be measured and paid separately under respective item of schedule.
All as per item No 01 above but for geysers of capacity 25 litres complete all as specified and as directed.
M&L Earthing complete with galvanised steel earth plate electrode 600x600x6mm thick, burried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m deep below normal ground level, connected to galvanised earth lead wire 4.0mm dia (7.50m) by means of bolts, nuts, check nuts & washers of galvanised iron or steel, earth lead wire protected by 15mm dia GI pipe light grade, 20mm dia light grade GI pipe for watering, meshed funnel, alternate layer of charcoal and common salt complete all as SSR Item No. 19471 and shown in electrical plate No. 3 of SSR part-I with PCC chamber, 50mm thick RCC cover in 1:2:4 type B-1 using 20mm graded stone aggregate reinforced with 8mm dia TMT bar @ 80mm c/c both way in lieu of CI pit cover and protection including necessary excavation and earth work complete all as specified and as directed.
Comprehensive repair/maintenance of solar water heater of heating capacity 200/300 LPD (or 2x100/ 3x100 LPD) installed at the roof top of Md accn/OTM accn, vertical or horizontal type comprising of the following: (a) Opening or dismantling the storage tank, taking down, de-scaling, brushing and thoroughly cleaning. (b) checking of all solar plate, stop cock, pressure release valves, fusible plugs for its serviceability etc. in situ to ensure proper functioning of parts including supply and replacing of washers/ gasket nut etc. (c) Checking and rectify earth continuity of the Electrical circuits of solar water heater. (d) Descaling of collectors with acid. NOTE: Unserviceable Parts/ components of Solar water heater shall be replaced by the contractor. (ii) Supply of new parts/components shall be measured and paid separately under respective item of schedule.
Supply only heating elements of capacity 3 KW AC 240 volts suitable for storage type solar water heater as per requirement (press type/ screw type/ triangular/ circular base or ceramic cartige type), ISI marked complete all as specified and as directed.
S&F in repair bib taps 15mm bore, half/quarter turn, fancy type, long body, cast copper alloy, chromium plated, screwed for iron pipe or for brass ferrule including all accessories complete all as specified and as directed.
S&F in repair 15mm bore Steel water tubing 'medium grade', galvanised with all fittings like elbow, tee, socket, bend etc and fixed to wall, ceiling or laid in floors complete all as specified and as directed.
S&F in repair 500 litres capacity rotational molded polyethylene water storage tanks (cylindrical vertical with closed top), hoisted and fixed in position complete all as specified and directed
M&L in replacement thermal solar module panel with heat resistant toughend glass including copper lead used for solar water heater based on indirect transfer of heat of capacity 100 LPD by disconnecting old unserviceable solar panel complete all as specified and directed
M&L in replacement thermal solar module panel with heat resistant toughend glass including copper lead used for solar water heater based on indirect transfer of heat of capacity 200 LPD by disconnecting old unserviceable solar panel complete all as specified and directed
M&L in replacement thermal solar module panel with heat resistant toughend glass including copper lead used for solar water heater based on indirect transfer of heat of capacity 300 LPD by disconnecting old unserviceable solar panel complete all as specified and directed
M&L in replacement hot water tank suitable for solar water heater based on indirect transfer of heat of capacity 100 LPD complete all as specified and directed.
M&L in replacement hot water tank suitable for solar water heater based on indirect transfer of heat of capacity 200 LPD complete all as specified and directed.
M&L in replacement hot water tank suitable for solar water heater based on indirect transfer of heat of capacity 300 LPD complete all as specified and directed.
S&F in repair MCB, single pole & neutral 32 Amp, 240 volts, 10 KA breaking capacity, 'C' curve complete all as specified and as directed.
S&F 1100V grade heavy duty XLPE armoured cable, PVC insulated copper conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connection of size 6sqmm, 3 core cable complete all as specified and as directed
S&F in repair sub main wiring with two single core PVC insulated (FRLS) unsheathed multistranded copper conductor of size 6sqmm nominal cross sectional area and one run of 6sqmm nominal cross sectional area PVC insulated (FRLS) unsheathed multistranded copper conductor green colour as continuous earth wire drawn in and including 25mm dia 'medium grade' PVC concealed conduits (ISI marked) and fittings complete all as specified and as directed. NOTE:- One unit length shall measured as two run of main wire and one run of conduit & earth wire.
S&F in repair pressure pump, 1 HP capacity, electric driven, single phase AC 230 volt maintaining suitable pressure in water supply distribution system at bath room, by disconnecting of unserviceable pump motor incluing GI fitting like Tee, elbow, nipple, socket, reducer etc. of any size complete all as specified and as directed.
Supply only thermostat of Type EST 11/20A, 240 Volt of ISI marked approved make complete all as specified and as directed.
Supply only thermostat of Type EST 7/15A, 240 Volt of ISI marked approved make complete all as specified and as directed.
Supply only heating element of capacity 2 KW, AC 240 volts, suitable for storage type electric water heater as per requirement (press type/ screw type/ triangular/ circular base or ceramic cartrige type), ISI marked complete all as specified and as directed.
S&F in replacement heating element of capacity 2000 watt modular type suitable for storage type electric water heater as per requirement (press type/ screw type/ triangular/ circular base or ceramic cartrige type), ISI marked complete all as specified and as directed.
Supply only copper syphon (door) assembly suitable for geyser of capacity 50 litres of any type as required complete with inlet and outlet and provision for thermostat pipe with drain pipes with drain plug, screws, studs, clamps for fixing heating elements etc. including gasket complete all as specified and as directed.
Supply only copper syphon (door) assembly suitable for geyser of capacity 25 litres of any type as required complete with inlet and outlet and provision for thermostat pipe with drain pipes with drain plug, screws, studs, clamps for fixing heating elements etc. including gasket complete all as specified and as directed.
Supply only polycorbonate 3-pin, 16 amps Plug top, white complete all as specified and as directed.
Supply only PVC insulated PVC sheathed flexible round stranded copper wire of size 1.5 sqmm, 3 core complete all as specified and as directed.
Supply only indicating LED lamp, Neon type, 240 volt AC suitable for 25/50 ltrs capacity geysers complete all as specified and as directed.
Supply only safety valve suitable for 25/50 litres capacity geyser complete all as specified and as directed.
S&F in repair sheet metal enclosures, single pole with socket plug top and MCBs with a two pin and earth plug and socket complete with one single pole MCB 20 Amps complete all as specified and as directed.
Modular type AC box with socket plug top and MCBs with two pin and one pin for earth plug and socket complete with one single pole MCB 20 Amp complete all as specified and directed
M&L for tracing and arresting of leakage in storage tank of 25 ltrs capacity geyser by brazing and soldering at leakage point and testing on completion complete all as specified and as directed.
M&L for tracing and arresting of leakage in storage tank of 50 ltrs capacity geyser by brazing and soldering at leakage point and testing on completion complete all as specified and as directed.
M&L for spray painting to 50 litres capacity geysers with one coat of synthetic enamel paint of approved tint including preparation of old steel surface and writing of serial/ MES no. with black colour synthetic enamel paint (height of letters not exc 2cm) including taking down of geyser and refixing in the same position after completion of painting work and making inlet/ outlet water connection and testing complete all as specified and as directed.
M&L for spray painting to 25 litres capacity geysers with one coat of synthetic enamel paint of approved tint including preparation of old steel surface and writing of serial/ MES no. with black colour synthetic enamel paint (height of letters not exc 2cm) including taking down of geyser and refixing in the same position after completion of painting work and making inlet/ outlet water connection and testing complete all as specified and as directed.
S&F in repair 450mm long PVC connection with brass adopter nut suitable for 15mm bore pipe and fixed complete all as specified and as directed.
S&F in repair 600mm long PVC connection with brass adopter nut suitable for 15mm bore pipe and fixed complete all as specified and as directed.
S&F in repair 750mm long PVC connection with brass adopter nut suitable for 15mm bore pipe and fixed complete all as specified and as directed.
S&F in repair 450mm long steel hose connection with brass adopter nut suitable for 15mm bore pipe and suitable for hot water and fixed complete all as specified and as directed.
S&F in repair 600mm long steel hose connection with brass adopter nut suitable for 15mm bore pipe and suitable for hot water and fixed complete all as specified and as directed.
S&F in repair non return valve of cast copper alloy suitable for 15mm bore pipe and fixed complete all as specified and as directed.
S&F in replacement stainless steel inner tank of capacity 25 litres geyser, vertical or horizontal type of any make complete all as specified and as directed.
S&F in repair metallic plug top suitabe for sheet metal enclsoure 20 Amp capacity complete all as specified and as directed.
S&F in repair base socket metallic suitable for sheet metal enclsoure 20 Amp capacity complete all as specified and as directed.
S&F in repair switch socket combination, flush type, single pole, multipurpose 2 in 1, 5 pin 5 and 15 Amp, 230 volts complete all as specified and as directed.
S&F in replacement instant type geyser 3 ltrs capacity with stainless steel inner tank, electric driven, single phase, AC 230 volt, rust and shock proof ABS outer body for long life including connecting water supply pipe with fitting as required at site complete all as specified and as directed. NOTE: Old geyser shall be deposited at E/M store yard.
S&F in replacement storage type water heater (geyser) of capacity 25 litres, electric driven, BEE five star rated, mild steel inner tank, AC 230 volt, vertical type and provn of fixing arrangement with 4Nos fastener of size 100x10 mm with washer and bolts and making water connection with 02 nos 450mm long flexible pipe and 16 Amp plug top complete all as specified and as directed. NOTE: Old geyser shall be deposited at E/M store yard.
Checking of ceiling fan 1200/1400mm sweep at site in existing position as per requirement based on MES complaint slip on daily basis except sunday/ holidays and provn of S&F of 2.5 mfd condensor of ceiling fan at site in position as in repair complete all as specified and as directed.
Checking of exhaust fan of any size/type at site in existing position as per requirement based on MES complaint slip on daily basis except sunday/ holidays and provn of S&F of 2.5 mfd condensor of ceiling fan at site in position as in repair complete all as specified and as directed.
Taking down carefully ceiling fan of any sweep and make after disconnecting all electrical connection, detaching the blades, removing fan with blades to workshop, opening and cleaning of fan, segregation of unserviceable parts, replacement of unserviceable spares parts with new parts including necessary machining work and lubricating with approved grade of grease and necessary minor soldering work (if required) and re-assembling the fan complete and testing and refixing the fan in same position including all electrical connection and provn of replacement of two nos split pins, one connection block and one rubber reel complete all as specified and as directed. NOTE: (i) Rewinding work of armature (if any) shall be measured and paid separately. (ii) Replacement of new spare parts with old unserviceable parts other than connector, split pins, connection block and rubber reel and same shall be measured and paid separately under respective item of schedule. (iii) Labour cost for replacement of spare parts shall deemed to be inclusive in quoted rate. (iv) The fan repair work will be done in AGE E/M Yard.
M&L for taking out and removing burnt copper winding, cleaning the armature, rewinding the fan armature for fan of size 1200/ 1400mm sweep with new super enamelled copper wire of existing gauge including provn of necessary insulating materials etc and varnishing with approved grade of insulation varnish and heating up and testing complete all as specified and as directed. Note: The ceiling fan winding work will be done in AGE E/M Yard.
Taking down carefully fan of any size/sweep exhaust fan, wall fan, cabin fan and fresh air fan after disconnecting all electrical connection, detaching the blades, removing fan with blades to workshop, opening and cleaning of fan, segregation of unserviceable parts, replacement of unserviceable spares parts with new parts including necessary machining work and lubricating with approved grade of grease and necessary minor soldering work (if required) and re-assembling the fan complete and testing and refixing the fan in same position including all electrical connection and provn of replacement of two nos split pins, one connection block and one rubber reel complete all as specified and as directed. NOTE: (i) Rewinding work of armature (if any) shall be measured and paid separately. (ii) Replacement of new spare parts with old unserviceable parts other than connector, split pins, connection block and rubber reel and same shall be measured and paid separately under respective item of schedule. (iii) Labour cost for replacement of spare parts shall deemed to be inclusive in quoted rate. (iv) Repair work of exhaust/wall/cabin fans wili be done in AGE E/M Yard.
M&L for taking out and removing burnt copper winding, cleaning the armature, rewinding the armature of exhaust fan of size 300mm sweep with new super enamelled copper wire of existing gauge including provn of necessary insulating materials etc and varnishing with approved grade of insulation varnish and heating up and testing complete all as specified and as directed. Note: The exhaust fan winding work will be done in AGE E/M Yard.
All as per item No 52 above but for exhaust fan of size 225/250mm sweep complete all as specified and directed
All as per item no 52 above but for exhaust fan of size 380/450mm sweep complete all as specified and directed
All as per item no 52 above but for PVC body exhaust fan of size 250/300mm sweep complete all as specified and directed
All as per item no 52 above but for PVC body exhaust fan of size 200mm sweep complete all as specified and directed
M&L for taking out and removing burnt copper winding, cleaning the armature, rewinding the armature of wall mounted cabin fan of size 300/400mm sweep with new super enamelled copper wire of existing gauge including provn of necessary insulating materials etc and varnishing with approved grade of insulation varnish and heating up and testing complete all as specified and as directed.
M&L for spray painting ceiling fan of any sweep with one coat of synthetic enamel paint of approved tint including preparation of old steel surface and filling cavaties with filler materials and writing of serial/ MES no. with black colour synthetic enamel paint (height of letters not exc 2cm) including taking down of fan and refixing in the same position after completion of painting work and making inlet/ outlet water connection and testing complete all as specified and as directed.
All as per item no 58 above but for exhaust fan of size any sweep complete all as specified and directed
S&F in repair ceiling fan regulator, electronic, rotary step up socket type, 230 volts suitable for 1200/1400 mm sweep ceiling fan including necessary connection complete all as specified and as directed.
S&F in repair ceiling fan regulator, electronic, rotary step up switch type, 230 volts suitable for 1200/1400 mm sweep ceiling fan including necessary connection complete all as specified and as directed.
M&L for flexible multi stranded copper wire twin twisted two core of size 0.75sqmm complete all as specified and as directed.
S&F in replacement of new metal bush made out of Gun metal/ Brass of same size suitable for ceiling fan, wall mounted fan and exhaust fan complete all as specified and as directed.
S&F in replacement of roter shaft of ceiling fan, exhaust fan, wall fan of any capacity, make and type complete all as specified and as directed.
S&F in replacement of ball bearings No. 6201 and 6202 suitable for fan complete all as specified and as directed.
S&F in replacement of ball bearings No. 6203 and 6204 suitable for fan complete all as specified and as directed.
S&F in replacement of capacitor 1.5 Mfd, 400Volts, 50Hz complete all as specified and as directed.
S&F in replacement of capacitor 2.5 Mfd, 400Volts, 50Hz complete all as specified and as directed.
S&F in replacement of plastic body exhaust fan of size 300mm complete all as specified and as directed.
S&F in replacement of plastic body exhaust fan of size 250mm complete all as specified and as directed.
S&F in replacement of plastic body exhaust fan of size 200/225mm complete all as specified and as directed.
S&F in replacment of cabin fan of size 300mm sweep, opal white, 250 Volt complete all as specified and as directed.
S&F in replacment of cabin fan of size 400mm sweep, opal white, 250 Volt complete all as specified and as directed.
S&F of exhaust fan super enamelled copper winding, single phase, 230/240 Volt heavy duty of size 230 mm sweep 1400 RPM, including suitable louvers and making connection with twisted copper flexible wire 23/0.076mm complete all as specified and directed Note:- Old ceiling fan shall be deposited in AGE E/M yard for BER action.
S&F of exhaust fan super enamelled copper winding, single phase, 230/240 Volt heavy duty of size 300 mm sweep 1400 RPM, including suitable louvers and making connection with twisted copper flexible wire 23/0.076mm complete all as specified and directed Note:- Old ceiling fan shall be deposited in AGE E/M yard for BER action.
S&F of exhaust fan super enamelled copper winding, single phase, 230/240 Volt heavy duty of size 450 mm sweep 1400 RPM, including suitable louvers and making connection with twisted copper flexible wire 23/0.076mm complete all as specified and directed Note:- Old ceiling fan shall be deposited in AGE E/M yard for BER action.
S&F in repair blade set of exhaust fan of size 450mm sweep with frame, four legs and coupling complete all as specified and as directed.
S&F in repair blade set of exhaust fan of size 380mm sweep with frame, four legs and coupling complete all as specified and as directed.
S&F in repair blade set of exhaust fan of size 300mm sweep with frame, four legs and coupling complete all as specified and as directed.
S&F in repair blade set of exhaust fan of size 225/230mm sweep with frame, four legs and coupling complete all as specified and as directed.
S&F in repair blade set of cabin fan of size 400mm sweep with frame, four legs and coupling complete all as specified and as directed.
S&F aluminium blade set (set of three) suitable for 1200mm sweep ceiling fan of any type and make complete all as specified and as directed.
S&F aluminium blade set (set of three) suitable for 1400mm sweep ceiling fan of any type complete all as specified and as directed.
S&F in replacement down rod 0.60m long made out of 15mm bore GI tubing, medium grade, with both side hole/slot for fixing of ceiling fan complete all as specified and directed
S&F in replacement down rod 1.00m long made out of 15mm bore GI tubing, medium grade, with both side hole/slot for fixing of ceiling fan complete all as specified as directed.
S&F in replacement down rod 1.25m long made out of 15mm bore GI tubing, medium grade, with both side hole/slot for fixing of ceiling fan complete all as specified as directed.
S&F in replacement down rod 1.75m long made out of 15mm bore GI tubing, medium grade, with both side hole/slot for fixing of ceiling fan complete all as specified as directed.
S&F in replacement hanging clamp with GI hook suitable for fixing on ceiling fan down rod, made out of 40x5mm GI strip, of any type, with rubber reel, split pin, bolts, nut and washer complete all as specified and as directed.
M&L for servicing of desert cooler of any make and size by cleaning, oiling & greasing, checking of defects and replacement of unserviceable switches, control switch etc. including complete electric wiring with 3 core flexible cable, plug top and testing complete all as specified and as directed.
S&F in replacment of submersible pump 25 to 45 watt, single phase, suitable for desert cooler complete all as specified and as directed.
S&F in replacment fan kit for desert cooler complete with legs, fan blade, 1/6 HP, 210 watt heavy duty copper wound electric driven, metal body, single phase 230 volts having normal air capacity of 4000 cum per hour complete all as specified and as directed.
S&F fan blade for cooler as per sample complete all as specified and as directed.
S&F wood wool pad (set of 3), superior quality, suitable for desert cooler of any size complete all as specified and as directed.
S&F in replacement PVC gang box fitted with and including piano type switch 15 A and socket 15 A, 230 Volts complete with pvc gitties and screws complete all as specified and directed
M & L for making opening of holes circular/square in brick wall 230/460mm thick built in cement mortar and making good surface with cement mortar 1:3 including all necessary nuts, bolts, washers etc complete all as specified and as directed.
M/s PS Associates (BID ID -3052701)
avon electric engineering woks (BID ID -3059108)
Mohinder Pal and Sons (BID ID -3053619)
Bidder Name
M/S Reliance Construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .