Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.9 CrAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹2.1 Cr+₹16.9 L (8.86%)Admitted-Finance 405 D SQUARE OPP GOKHALIBAI SCHOOL DADABHAI CROSS ROAD VILE PARLE WEST MUMBAI 400056 | MUMBAI | MUMBAI | MAHARASHTRA | 400056 | L2 | Admitted-Finance | |
| 3 | Rejected-Technical NIL | NA | NA | 121004 | - | Rejected-Technical Documents Not Complied | |
| 4 | Rejected-Technical B 14 EVERARD NAGAR EASTERN EXPRESS HIGHWAY SION MUMBAI 400 022 | MUMBAI | MUMBAI | MAHARASHTRA | 400022 | - | Rejected-Technical Documents not complied |
| Sl No | Description | Qty | Unit | Star Electric L2 | scientific electrical services L1 |
|---|---|---|---|---|---|
| 0.00Work of replacing power backup systems at Worli Hub | |||||
| 1.00 | SITC of D.G.SET WITH PANEL -500KVA (R3-ME-6-17-qq) | 2 | NOS. | 64,64,949.12 ₹1,29,29,898.24 | 60,25,559.68 ₹1,20,51,119.36 Lowest |
| 2.00 | 1st category Al armoured cables FRLS outer sheathed- 3.5C x 300 Sq.mm(R3-ME-2-1-ac) | 810 | Mtr. | 1,893.01 ₹15,33,338.1 | 1,782.42 ₹14,43,760.2 Lowest |
| 3.00 | Cable End Termination For Aluminium Cables – 3.5C x 300 Sq.mm (R3-ME-2-12-ac) | 32 | Set. | 1,624.83 ₹51,994.56 | 1,529.91 ₹48,957.12 Lowest |
| 4.00 | 1st category Al armoured cables FRLS outer sheathed- 2C x 2.5 Sq.mm (R3-ME-2-3-e) | 270 | Mtr. | 120.47 ₹32,526.9 | 113.44 ₹30,628.8 Lowest |
| 5.00 | Cable End Termination For Al Cables – 2C x 1.5 / 2.5 Sq.mm (R3-ME-2-12-a) | 12 | Set. | 119.43 ₹1,433.16 | 112.45 ₹1,349.4 Lowest |
| 6.00 | 600 X 600 X 3.15 mm Copper Plate, 3000mm dip with suitable size cu strip earth pit as per IS 3043. The earth pit shall be provided with watering pipe (Class B) with wire messed funnel, 25X3 cu strip / 2X8SWG Cu.wire up to chamber, disconnecting links with 600 x 600 mm (clear) RCC chamber & 3mm thick heavy duty CI chequered plate cover with hinge. Bentonite shall be provided for earth pits. Excavation, back filling, removal of excess soil is included in the scope. (R3-ME-7-1-d) | 7 | NOS. | 25,589.73 ₹1,79,128.11 | 22,384.9 ₹1,56,694.3 Lowest |
| 7.00 | Earthing Continuity Conductors -25 x 3mm Tinned copper. (R3-ME-7-4-a) | 85 | Mtr. | 838.08 ₹71,236.8 | 797.12 ₹67,755.2 Lowest |
| 8.00 | Earthing Continuity Conductors -50 x 6mm GI (R3-ME-7-4-g) | 150 | Mtr. | 209.52 ₹31,428 | 197.28 ₹29,592 Lowest |
| 9.00 | Supplying and erecting Fire resistant Mortar (20 kg) with fire resistance class S90 as per National Electrical Code (NEC) SP30- 2011 suitable to seal the openings with all kinds of cables, pipes and cable support system in steel and aluminium and plastic
profiles (Except hollow core conductors). The residual openings shall be closed with filler, as per specification(R3-ME-15-27-a) | 35 | Sqf | 2,258.63 ₹79,052.05 | 2,040.44 ₹71,415.4 Lowest |
Tender Value
Refer Docs
EMD Value
₹2.0 L
Closing Date
18 Sept 2026, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE HQ
Office of EE HQ BMC HO
The work of Replacement of two nos of old 500 KVA DG Set with two nos of new 500 KVA DG Set with allied fire safety and fabrication work in Engineering Hub Worli
2026_MCGM_1334764_1
AMC/City/D/1375 dtdt 18.08.2026
Open Tender
Electrical and Maintenance Works
Item Rate
150 days
BMC HO
Please refer Tender documents.
3 documents required · 3 mandatory
₹23,559
₹2.0 L
26 Oct 2026
4 Sept 2026
21 Sept 2026
4 Sept 2026
18 Sept 2026
4 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 0 | Work of replacing power backup systems at Worli Hub | - | - | - | - |
| 1 | SITC of D.G.SET WITH PANEL -500KVA (R3-ME-6-17-qq) | 2 | NOS. | - | - |
| 2 | 1st category Al armoured cables FRLS outer sheathed- 3.5C x 300 Sq.mm(R3-ME-2-1-ac) | 810 | Mtr. | - | - |
| 3 | Cable End Termination For Aluminium Cables – 3.5C x 300 Sq.mm (R3-ME-2-12-ac) | 32 | Set. | - | - |
| 4 | 1st category Al armoured cables FRLS outer sheathed- 2C x 2.5 Sq.mm (R3-ME-2-3-e) | 270 | Mtr. | - | - |
| 5 | Cable End Termination For Al Cables – 2C x 1.5 / 2.5 Sq.mm (R3-ME-2-12-a) | 12 | Set. | - | - |
| 6 | 600 X 600 X 3.15 mm Copper Plate, 3000mm dip with suitable size cu strip earth pit as per IS 3043. The earth pit shall be provided with watering pipe (Class B) with wire messed funnel, 25X3 cu strip / 2X8SWG Cu.wire up to chamber, disconnecting links with 600 x 600 mm (clear) RCC chamber & 3mm thick heavy duty CI chequered plate cover with hinge. Bentonite shall be provided for earth pits. Excavation, back filling, removal of excess soil is included in the scope. (R3-ME-7-1-d) | 7 | NOS. | - | - |
| 7 | Earthing Continuity Conductors -25 x 3mm Tinned copper. (R3-ME-7-4-a) | 85 | Mtr. | - | - |
| 8 | Earthing Continuity Conductors -50 x 6mm GI (R3-ME-7-4-g) | 150 | Mtr. | - | - |
| 9 | Supplying and erecting Fire resistant Mortar (20 kg) with fire resistance class S90 as per National Electrical Code (NEC) SP30- 2011 suitable to seal the openings with all kinds of cables, pipes and cable support system in steel and aluminium and plastic
profiles (Except hollow core conductors). The residual openings shall be closed with filler, as per specification(R3-ME-15-27-a) | 35 | Sqf | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.68 MB
Tendernotice_2.pdf
PDF • 0.62 MB
SBD.pdf
Tender Documents • 2.67 MB
BOQ_2283860.xls
BOQ • 0.30 MB
BOQ.pdf
Other Document • 0.60 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .