Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹47.0 LAccepted-AOC 111 GB MARG YADAV ELECTRIC MARKET LUCKNOW UP 226018 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226018 | 1 | Accepted-AOC Being L-1 | |
| 2 | 2₹48.6 L+₹1.5 L (3.24%)Rejected-Finance | 2 | Rejected-Finance Being other than L-1 | |
| 3 | 3₹49.6 L+₹2.6 L (5.45%)Rejected-Finance 9 NAROTTAM KUNJ MADHU NAGAR AGRA CANTT 282001 | AGRA | UTTAR PRADESH | 282001 | 3 | Rejected-Finance Being other than L-1 |
Tender Value
₹47.2 L
EMD Value
₹94,400
Closing Date
19 Dec 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Adm Area Agra 282008
GE (AF) Adm Area Agra 282008
PROVISION OF POWER SUPPLY FOR WAITING LOUNGE FOR PASSENGERS FACILITATION AT ARJUN NAGAR GATE UNDER GE AF ADM AREA AT AF STATION AGRA
2022_MES_564719_1
8000-2011/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AF Station Agra
Class D
cat b i
8 documents required · 8 mandatory
₹500
GE AF Adm Area Kheria Agra
₹94,400
Yes
23 Jan 2023
23 Nov 2022
21 Dec 2022
23 Nov 2022
19 Dec 2022
7 Dec 2022
23 Nov 2022 - 6 Dec 2022
Amount
Excavating in trenches n.exc 1.5 m wide and n.exc 1.5 m in depth for foundation etc or for laying for cables etc n.exc 10 sqm on plan and n.exc 1.5 m in depth and getting out in any type of soil including removal of sand, bricks/PCC covers laid for cable proection complete all as specified and directed.
Returning, filling in, trenches including spreading, levelling, watering and well ramming in layers not exc. 25 cm in any type of soil complete all as specified and directed.
Removing surplus excavated material n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed.
Supply and Laying including testing in floor/trenches or fixed on pole/wall XLPE LT UG cable PVC insulated, bedded, galvanised steel strip or wire armoured heavy duty electric cable 1100 volts grade with aluminum conductor of 400 Sqmm 3.5 core complete all as specified and directed.
Supply and Laying including testing in floor/trenches or fixed on pole/wall XLPE LT UG cable PVC insulated, bedded, galvanised steel strip or wire armoured heavy duty electric cable 1100 volts grade with aluminum conductor of 120 Sqmm 3.5 core complete all as specified and directed.
Supply, installation, commissioning and testing of approved OEM factory assembeled diesel engine driven generating set latest Technology, inbuilt battery charger and remote monitoring system of Capacity 160 KVA, ENGINE 200 BHP, 3 phase, 4 wire, 415 Volts, 1500 RPM, AC power supply with power factor 0.8 coupled directly to alternator mounted on a common base plate complete with fuel tank, battery, AMF panel including PCC foundation of DG set/ AMF Panel as per drawing of OEM and standard accessories and fittings, install on vibration pad, sand cushioning around PCC foundation. The DG set control panel fo mounting oil pressure, hours run, emergency stop button, RPM meters, water temperature etc. which are required to check for smooth functioning of DG set during its runnning period. All other safety provisions shall be provided as per direction of Engr-in-Charge/Accepting Officer.
(a) Diesel Engine: Liquid cooled turbo charged with after cooler to deliver suitable BHP at 1500 RPM under NTP conditions confirming to IS-100001/ISO3046/BS 649/BS 5514 amended upto date and conforming to (Prime continous rating as per ISO 8528-1) with an overload capacity of 10% for one hour in any 12 hours, water cooled naturally turbo charged capable of giving adequate BHP to drive alternator of capable 160 KVA at NTP, continuous operation with the following accessories. Diesel engine of rated speed at full load electric start developing with system with radiator and including electronic governor control of class A1, engine control panel, lub oil pump, water pump, fuel tank, exhaust pipe with silencer and suitable for electric start with batteries of adequate capacity and suitable for alternator of specified capacity complete with fly wheel direct/flexible coupling and coupling guard complete. Make: KOEL GREEN (KIRLOSKAR GREEN) MODEL 6K1080TAG2 or equivalent in CUMMINS/ ASHOK LEYLAND
(i) Radiator with blower fan or heat exchanger with guard. (ii) Pipe coupling for engine cooling system piping. (iii) Corrosion inhibitor coolant (iv) Paper element filters (v) Fuel filter and fuel houses (vi) Lube oil filter and pump (vii) Vaccum indicator (viii) Dynamically ballanced Fly wheel housing and fly wheel to suit alternator. (ix) Engine bearing mechanism in fly wheel housing. (x) Shut off coil with safeties for LLOP/HWT/over speed. (xi) Dry type air cleaners and vacuum indicators. (xii) Residential silencers. (xiii) Stainless steel exhaust flexible bellows. (xiv) Motor driven priming pump. (xv) Battery charging alternator.
(xvi) Air cleaner oil bath type. (xvii) Interconnecting copper cabling of adequate capacity batteries control. (xviii) Fuel pipe class STIC 1" /1.5" /2" dia - 01 lot (xix) Self starter 12 volts DC. (xx) Electric operated electronic governor class 1A, Flywheel with starter ring. (xxi) Fuel injection pump.
(xxii) Electronic instrument panel, complete with all accessories as per manufacturer's specifications displaying :- (xxiii) Electric starting system with battery charging alternator includigng adequate number of high capacity maint free lead acid battries 12 V DC, 160 AH Battery. - 2 Nos as per manufacturer recommendation iincluding copper lead and batery terminals complete with starting/stopping switch voltmeter etc Set 1 . (xxiv) Engine safety shut down system against low oil pressure and high water pressure. (xxv) lubricating oil cooler. (xxvi) Engine main manual with spare part lists (xxvii) Dry exhaust manifold with suitable exhaust residential grade silencer to reduce the noice level. (xxviii) Suitable designed acoustic enclosure as per latest CPCB regulations/guidlines. (xxix) Voltage. (xxx) Safety control (Trip and indication). (xxxi) High water temperature (xxxii) Low lube oil temperature (xxxiii) Overspeed stop, emergency stop
(b) Base frame: Base frame is fabricated either in ISMC channel or in sheet metal. The base frame will be primer coated and painted. The base frame is rugged in construction and designed for mounting engine and KG alternator close coupled, with cross members mounted on AVM. The base frame shall have provision for mounting of acoustic enclosure & control panel on it. The base frame is having provision of lifting hook for convenient lifting of complete set, i.e. along with canopy, engine and alternator alonwith AVM pads. (c) Fuel tank: fuel tank of 8 hours of continuous operation, fabricated form 14/16 SWG sheet metal with level indicator fuel inlet, fuel outlet, air vent, drain plug, in let arrangement for diesel filling fro exterior canopy (without opening its panel) etc complete all as specified and directed.
(d) ALTERNATOR : Synchronous alternator suitable for continuous operation at 1500 RPM generating 415 volts at 0.8 p. f (lag) suitable for 50 Hz, three phase, 4 wire system, H Class of insutation class, 92.8% of alternator efficieny (at 100% load) 0.8 pf, <. 20% socMax voltage dip at full load 0.8 pf Lag. The alternator shall be brushless, single bearing, self excited & self regulated with an AVR. The alternator will be suitable for tropical climate and shall generally confirm to IS: 4722. The salient features of the alternators are: (i) +-1% voltage regulation (max) in static conditions. (ii) IP: 23 protections with class „H‟ insulation. (iii) Permanent lubricating bearing. (iv) Permissible overload of 10% for one hour in 12 hours of operation. Make: KIRLOSKAR/ STAMFORD/ CROMPTON
(e) Acoustic Enclosure:- Acoustic enclosure shall be powder coated and fabricated out of 16 SWG CRCA MS sheet. The silent canopy shall be of nut bolt type construction. Critical processes of punching is done on CNC machines to maintain dimensional accuracy of holes within 0.1 mm. Powder coating is done after seven-tank surface preparation process of sheet metal. Canopy panel and doors shall have inside lining of FIRE-RETARDANT foam as acoustic material & Rock wool for hot zone. Adequate hinged doors shall be provided to canopy, one door shall have glass window for control panel visibility. The average sound level, when measured in green field condition (ISO 3744 OR 8528 PT 10) at 1-meter distance from all four sides shall be less than 75-dBA averages or as per CPCB norms.Inside illumination : 1 No.- 1 x 10 watt led fitting
(f) AMF Control panel:- Factory fabricated cubicle type, free standing, floor mounted, indoor type, IP-52, AMF control panel, provided with removable rear panels & hinged front panel for easy accessibility, fabricated out of not less than 2 mm thick CRCA sheet including two coats of powder coated paint over a coat of red oxide primer etc and comprising of following:
(g) Digital load manager : Three phase 4 wire indicating V,I,PF, KVA, KW, F of Enercon make with serial communication port model No.EM6400 with class 1.0 accuracy meter or equivalent make suitable rating of CT per phase- one No. (g) Bottom gland plate for incoming and outgoing cables. (h) Circuit diagram plate.
(h) Civil works:- All civil works related to foundation as per Manufacturer drawings and specifications, installation of panel and equipment & depth of foundation shall be minimum 300mm with and vibration pads, or as recommended by manufacturers. Cable from DG set to AMF panel, AMF panel to main panel will be measured under relevant schedule. Note:- (i) Capacity of engine, alternator shall be work out taking all derating factors into consideration the delivering 160 KVA Cap (i) The fuel for final testing of 12 hours shall be supplied by the contractor and cost deemed to be included in the quoted rate. All other necessary equipments of load test/water test like resistance load strip heater of suitable capacity/rating and any other items required for final testing shall be provided by the contractor without any extra cost to department. (iii) DG Set should be compliance with Ministry of Environment and forests notification GSR 771(E) and latest CPCB guidelines.
Supply, installation, testing and commissioning of outdoor type floor mounting Polycarbonate CPRI approved OEM made LT Panel , shall be made of modular POLYCARBONATE THERMOPLASTIC ENCLOSURES which should be UV resistance in accordance with IEC 61439-1, clause 10.2.4: The panel should be anti-acid & anti corrosive. Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262. The manufacturer of board/panel shall submit a copy of CPRI TEST REPORT IN POLYCARBONATE OF DEGREE OF INGRESS PROTECTION IP65 IN ACCORDANCE WITH IEC 60529. The gasket should be internally embedded made of polyurethane. The manufacturer of board/panel SHALL submit a copy of TYPE TEST REPORT of a board made out of Polycarbonate thermoplastic panel in accordance with IEC 60439-1. The CPRI report shall have mention of following tests performed and passed out satisfactorily: Temperature Rise, Dielectric Properties, Short circuit withstand current – Rated peak & short time withstand current and Rated Conditional Short Circuit Current, Effectiveness of Protective Circuits. The board manufacturer must submit the copy of type test reports for Polycarbonate Thermoplastic Board only. Test Reports submitted of other material of construction like MS, SS will not be applicable. Guarantee and warrantee certificates will be accepted only from original manufacturer. The panel should passed glow wire test 960oC in accordance with 60695-2-11 [flame retardant and self-extinguishing with MC 75 for base frame & angle iron 50 x 50 x 6 mm size legs , 04 nos legs 600 mm long, PCC 1:2:4 type B-1 for grouting of base,suitable for 3 phase 415 volts 50 Hz 4 wire AC supply complete all as directed with and incl the following:-
BUS BAR - TPN copper bus bar of rating not less than 1.5 times the rated capacity of the incomer MCCB. The TPN bus bar shall be insulated with colour coded hot shrinkable sleeves and shall be mounted on F class insulators. Busbar should be short time current capacity 30kA Peak. INCOMING MCCB a) 400 Amp 4 pole, 36 KA breaking capacity with adjustable thermal magnetic setting with earth fault protection with Rotary Handle, Ics= 100% Icu - 02 Nos. b) 2 Lock + 1 LEY Mechanical Interlock - 01 No. METERING (a) Multifunction meter 96 Sqmm - 02 Nos (b) R/Y/B LED indicating Lamp - 02 Nos/EACH (c) Current Transformer 400/5A,5VA,CL1 - 06 Nos (Make : ELMEX/KAPPA/ TRANSTECH) (d) 2/32A Control Fuse Base with link - 12 Nos.
OUTGOING MCCB a) 250 Amp 4 pole MCCB 36 KA breaking capacity with adjustable thermal magnetic setting with earth fault protection with rotary Handle, Ics= 100% Icu - 02 Nos. (01 Working + 01 stand By) (b) 160 Amp 4 pole MCCB 25 KA breaking capacity with adjustable thermal magnetic setting with earth fault protection with rotary handle, Ics= 100% Icu - 01 Nos. (c) 63 Amp 4 pole MCCB 16/18 KA breaking capacity with adjustable thermal magnetic setting with earth fault protection with rotary handle, Ics= 100% Icu - 02 Nos. (d) 32 Amp MCB TPN - 01 No (e) AC Three phase static energy meter of accuracy class 1.0 ,3 X 240 V ,50 Hz with Backlit LCD display suitable capacity alongwith set of 03 Nos 200/5A LT CT's (measures and displays KWH ,V, Current I, KW, pf last month history of KWH, MD in KW) with special features like TOD, temper logging, optical communication port display in absence of power - 01 No. (Electric meter reading seen should be without opening of any door of LT Panel) Note : (a) Cable Entery should be Incoming/out going from seperate cable galley. (b) All Incoming/Out going MCCBs provide suitable size of copper connection plates. (c) All Incoming/Out going MCCBs provide spreader Links - 04 Nos Each. (d) Provision of gland holes including as per direction of Engr-in-Chage. (e) All Incoming/out goings MCCBs should be Marking label/End plate/End clams/suitable size of Terminal Block Stud/screwless type etc (Make - HENSEL/ABB/ INDO ASIAN/ Power Systems & Control Jalandhar)
M&L for earthing complete with galvanized steel earth plate electrode 600x600x6mm tthick buried directly in ground(earth pit not less than 3.25 mtr deep below the normal ground level) with top edge of plate not less than 2.5 mtr below the normal ground level connected to galvanized earth strip 32X6mm thick by means of nuts, bolts, washers and check nuts of galvanised iron or steel and welding full length of strip with earth plate, 40 mm bore GI pipe light grade proection pipe up to test point, 20mm dia light grade GI pipe for watering, meshed funnel, alternate layer of charcoal and common salt complete all as per SSR with PCC chamber, 50mm thick RCC cover in 1:2:4 type B-1 using 20mm graded stone aggregate reinforced with 8mm dia TMT bar @ 80mm c/c both way in lieu of CI pit cover and protection including necessary excavation and earth work complete all as specified and directed.
M&L for earthing complete with copper earth plate electrode 600x600x3.15 mm tthick buried directly in ground(earth pit not less than 2.25 mtr deep below the normal ground level) with top edge of plate not less than 1.5 mtr below the normal ground level connected to copper earth strip 20 x 3 mm thick by means of nuts, bolts, washers and check nuts of brass, 40 mm bore GI pipe light grade proection pipe up to test point, 20mm dia light grade GI pipe for watering, meshed funnel, alternate layer of charcoal and common salt complete all as per SSR with PCC chamber, 50mm thick RCC cover in 1:2:4 type B-1 using 20mm graded stone aggregate reinforced with 8mm dia TMT bar @ 80mm c/c both way in lieu of CI pit cover and protection including necessary excavation and earth work complete all as specified and directed.
M&L for shifting of transformer 11/0.433 KV installed on PCC platform, indoor/outdoor type from one sub stn to another sub stn in Air Force Stn Agra including disconnecting elect connection LT/HT side and earthings re-installation at site and connect LT/HT connecion, commissioning and testing complete all as specified and as directed of cap 200 to 500 KVA Note : upto 500 KVA Transformer shilfted to proposed site and 200 KVA transformer shifted to exisitng site upto 500 KVA Transformer.
Supply, fixing including testing MCCB 400 Amp, 4 Pole, 50 Hz, 415 V with rupturing capacity 50KA with thermal magnetic release adjustable type is to be fixed in existing LT panel including suitable size of copper connecting strips, Lugs, nut bolts including cutting, griding, painting as per existing colour and making good surface complete all as specified all as directed.
Supply and laying ISI marked double walled corrugated High density poly ethylene pipes (HDPE) inner plain, type 750N with RR & NPF (6M) , as per IS 16205 Part 24 (supercedes IS-14930 Part II & RDSO specification, Anti Rodency - to avoide rodent attacks, Non Flame propagation property - Resistance to flame propagation, permanently lubricated silicore inner layer for smooth insertion, anti termite of nominal size 120mm outer dia/ inner dia 102 mm including all fittings complete laid in trenches for protection of cable complete all as specified and directed . Make :- Astral / JPC pipes Pvt Ltd./ Bhagwati Plastic & Agriculture Industries.
M&L for drilling suitable dia horizontal bore holes for insertion / laying of up to 100 mm bore GI/HDPE tubing of any description below/under road surface/floors etc. with using mechanical or manual devices as required at site including making good disturbed surface to match with the existing streta after laying pipes complete all as specified and directed.
M&L for straight through joints (heat shrinkable) any type suitable for XLPE 1100 Volts cable of size 400 Sqmm 3.5 core and testing after jointing complete all as specified and directed.
BHARADWAJ BROTHERS
M/s SCHOLASTIC ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .