Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.7 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹19.8 L+₹9,915 (0.50%)Rejected-Finance TOROWAL LC SOCIETY VILLAGE TOROWAL TEHSIL BLACHOUR DISTT S B S NAGAR | SRI MUKTSAR SAHIB | PUNJAB | 151202 | L2 | Rejected-Finance Rejected Being L2 | |
| 3 | L3₹23.7 L+₹3.9 L (19.9%)Rejected-Finance | L3 | Rejected-Finance Rejected Being L3 |
Tender Value
₹19.6 L
EMD Value
₹39,500
Closing Date
16 Feb 2023, 4:00 pmClosed
Sr. Executive Engineer
Sr. Executive Engineer Township Division BBMB Sundernagar
Uplifting water from Overhead Tank and distributing it to entire old S 2 to S 0 area with the use of Galvanized Mild Steel pipe Medium of 150mm dia 4.80mm thickness using inline booster pump of 15 HP in BBMB colony Sundernagar.
2022_BBMB_93483_1
NIT-09/2022-23-TShipSnr
Open Tender
Civil Works
Tender cum Auction
240 days
Sundernagar
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,180
₹39,500
25 May 2023
12 Dec 2022
17 Feb 2023
12 Dec 2022
16 Feb 2023
12 Dec 2022
Amount
Excavation manually in trenches for pipe lines with straight or open cutting in streets and lanes in builtup area where width of street / Lane from wall to wall is less than 3 meter including trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation, watering , including the cost of dewatering of rain water, diversion for traffic,night signals. Providing & fixing caution boards, watching, fencing, etc. and removal of surplus soil from the site upto 15 meter distance complete in all respects. (a) Earth work upto 1.5 m. Depth (i) All classes of soil except rocky
Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centering and shuttering in foundation and plinth.
Mild steel requirement for RCC work where not including the complete rate of RCC including bending, binding and placing in position complete in all respects. (i) Up to 20mm dia bars
Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering)
Providing , laying, jointing ( by way of circumferential butt welded joints by electrical arc welding ) and testing of GMS pipe of following dia meters confirming to BIS 1239 (Part-1), grade specified below (latest with upto date amendments) having wall thickness as specified below with bevelled ends and capable of withstanding required test pressure in a random length of 4 to 7 meters, including manufacturing reducers/ tapers , all short pieces, beds etc. as per site requirement made from parent tubes . The laying of pipe will include all operation such as cutting, welding, jointing, fabrication of bends, tees etc. including lowering and laying in excavated trenches to ensure required level including flushing, cleaning and hydraulic testing complete in all respects to the satisfaction of the Engineer in charge. The fabricated bends should have three or four cuts having its radius not less than five times the dia of pipe. The pipes should be factory galvanized (zinc coating both inside and outside) as per relevant IS standards. The welding electrodes should be as per IS 814 of Advani Oerlikon/ L&T or ISI marked make. The rates also includes entire carriage of material, flushing, cleaning & hydraulic testing complete to the best satisfaction & direction of Engineer in charge with in all leads and lifts. (Earth work in trenches will be measured and paid for separately).150 mm dia -GMS Pipe 4.80 mm thickness (Medium Class)
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing , testing & cost of Nut ,Bolt & insertion sheet, all carriage complete (with the approval of Engineer in charge). (B) Class PN-1.6 as per ISI (c)150mm i/d Sluice Valves flanged
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing , testing & cost of Nut ,Bolt & insertion sheet, all carriage complete (with the approval of Engineer in charge). 150mm i/d Reflux Valves flanged PN 1.6
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves ISI marked14846-2000, including jointing , testing & cost of Nut ,Bolt & insertion sheet, all carriage complete (with the approval of Engineer incharge).(B) Class PN-1.6 as per ISI (e) 250mm i/d Sluice Valves flanged 28.27 (B) (e)
Dismantling lead Caulked Joints of cast iron Socketted Pipes, Valves and Specials by heating the Joints including the cast of Labour, Fuel and tools, etc., collecting the lead taken out from the joints and ride back the same to the Engineer-in-charge. (j) 250mm i/d of pipes, valves and specials
Providing horizontal pindle, horizontal l/redial split casing/end suction(Back-pull out arrangements) single/double/multi stage inline booster pump/ centrifugal pump or combination of pumps, In series/parallel of recommended make such as Mather and Platt/KSB/ Beacon Weir/Kirlosker/BE/Jyoti as per BIS 1520-1980 with upto date ammendments, read with IS:9137-1978 or latest edition suitable for lifting water for under mentioned characterestics with bronze, impellers/priming funnels, casing ring and shaft sleeves of bronze, shaft of steel grade 4508 FN8 with cast iron casing coupled directly through a flexible coupling on a common MS/Cast steel base plate (base plate to be from the manufacturer of the pumping unit only) to slip ring/ squirrel cage screen protected drip proof induction motor /motors of standard make such as Kirlosker/BHEL /Crompton /NGEF /GEC/Siemens/Jyoti /ABB and suitable for operation on 400(+/-)10% volts,50 cycles /second.3 phase AC electric supply. The power of electric motor/motors should be at +10% in excess of the maximum power required by the pump/pumps in the operation range of (+) 10% and (-)15% of the duty point head. The motor/motors as per ISI:325:1978 with upto date amendments read with IS 900:1972. It should include cost of bearing nuts , bolts and painting & electrical items etc. and should meet the following requirements: Discharge (Q) 28.65 LPS for each pump. a) LWL in sump well (h) 886.00 meter b) Shaft level 887.00 meter c) Level at discharge point 903.00 meter d) Suction lift -ve e) Discharge head 16.00 meter f) Static head 16.00 meter Rising Main a) Length 550 meter b) Dia 150 mm Pumping hours 6 Hours Characteristics of water Clear water with turbidity up to 50 PPM. a) Temperature 25 degree centigrade.
Construction of masonary Sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department. Size 0.9 m. x 0.9 m
Bailing out water from the trenches for making new connections in existing pipe lines including cleaning trimming and dressing the trenches to correct alignment and grade as required by the Engineer-in-charge Connection with pipe line Upto 300mm i/d
Jointing of C.I. Pipes as per IS:1536, Valves and specials with lead caulked joints ,including cost of lead , yarn and cost of labour fuel and tools etc with testing complete. For 250mm i/d pipe lines
Providing & fixing Flanged end connection arrangement, including jointing , testing & cost of Nut ,Bolt & insertion sheet, all carriage complete (with the approval of Engineer incharge). flanged MS pipe 12’’ dia as per ISI (as per approved drawing attached)
Bidder Name
Amount in Words
Arun Vishist Govt. Contractor
RAKESH KUMAR
LEKH RAJ
Arun Vishist Govt. Contractor
LEKH RAJ
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .