Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.1 LAccepted-AOC 53 HOUSING BOARD COLONY PHASE II UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | J K | 182101 | ₹42.1 L Quoted ₹42.3 L | L1 | Accepted-AOC L1 |
| 2 | L2₹43.9 L+₹1.6 L (3.85%)Rejected-Finance | ₹43.9 L+₹1.6 L (3.85%) | L2 | Rejected-Finance OTHER THAN L1 |
Tender Value
Refer Docs
EMD Value
₹84,200
Closing Date
12 Apr 2022, 6:00 pmClosed
GE UTILITIES UDHAMPUR
GE UTILITIES UDHAMPUR PO GARHI PIN 182121
Addn/Altn to the electrical distribution system and provn of water pipe line for arboriculture under GE (utilities) udhampur
2022_MES_508308_2
GE/U-69/2021-22
Open Tender
Miscellaneous Works
Item Rate
180 days
GE UTILITIES UDHAMPUR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE UTILITIES UDHAMPUR
₹84,200
Yes
6 May 2022
22 Mar 2022
14 Apr 2022
22 Mar 2022
12 Apr 2022
29 Mar 2022
Amount
Supply,Installation,Testing and Commisioning of HT 11KV, 3Phase 50Hz,having rupturing capacity minimum 350 MVA, totally metal clad withdraw able type, Vacuum Circuit Breaker ( Outgoing panel ) with Copper bus bar of suitable rating, horizontal isolation type VCB of capacity 630 Amps rated current, as per IEC 62271-100-200. The switchgear panel shall be of sheet steel construction with ALUZINC not less than 2.5mm thickness for load bearing section and not less than 2 mm thickness for non-load bearing and shall be totally dust and vermin proof. The offered panels shall be tested for IAC level of 25kA/1 Sec., No. of operation of Vacuum Interrupter Bottles. Following Parameters are desired :-
(i) Mechanical life -30,000 Nos , (ii) Rated Current – 10,000 Nos (ii) Rated Short Circuit Current – 100 nos.- All the main components like VI/ VCB/ Relays/ Meters shall be of same make. Approved Makes: ABB/Siemens/ Schneider/ L&T/ Crompton Greaves. Panel and VCB parameters are as below:- (i) Rated Voltage level/ PF withstand voltage/ Impulse level:12KV/ 28kV/ 75 kVp (ii) Continuous current rating: minimum 630 A (iii) Short circuit withstand current: minimum 25KA for 3sec. (iv) One no. minimum 630Amps horizontal draw out type vacuum circuit breaker in 12KV metal clad floor mounting panel complete with following:-
(a)Manually & Motor operated(230V,AC,50Hz) spring charged type, manually and electrically open (electrical – 110 VDC) operation type, incorporating mechanical as well as electrical ON/OFF indication "OFF" push button, test/service position limit switches, with minimum 6NO+6NC breaker auxiliary contacts in service position. (b) Cast resin Current transformer 11KV, 150-200/5-5A, Core1: class1, 15VA for 3 phase , Core2: 5P10, 15VA, (c) Cast resin potential transformer 11KV/V3/110V/V3/110V/3, 50VA, Cl 1.0, Cl 3P and HT Fuse at the primary end and 04 pole MCB at the secondary end of the PT (Confirming related IS specifications).
(A) Protection arrangements for the breaker shall comprise of the following: ( i) E/F, O/C, S/C, TCS with MODBUS protocol - Numerical Type system in built . ( ii) Relay should have Digital display as per manufaturer recommendations. ( iii) Complete with Master Trip/ Anti pumping relay. All the Relays shall belong to a common platform and shall be of single make (B) The following meters, indications and accessories are to be provided with the panel:-
Supply, installation, testing and commissioning of indoor type 11kv adopter panel with copper bus of 630Amps for bus extension and suitable connection to above new 4 nos VCBs 11kv 630Amps. Adaptor panel shall be manufactured by the company (M/s ABB / Schneider / Siemens/ L&T/ CG) as per site requirement to match existing VCB. Panels shall be fixed seamlessly. The phase to phase & phase to earth clearance of busbars inside the adopter panel should be maintained properly as per IEC complete all as specified and directed by Engr-in-Charge.
XLPE insulated, armoured, aluminium conductor cable, 11000 volts grade, heavy duty, cross sectional area 95 sq mm ,3 core, laid in trenches/ducts/through pipe complete all as specified and directed by Engr-in-Charge.
Cable jointing kit for 11 KV grade cable for out door termination heat shrinkable type joint complete with jointing material and acessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sq.mm complete all as specified and directed by Engr-in-Charge.
Providing earthing with GI earth plate electrode 600 X 600 X 6.3mm buried directly in ground (earth pit not less than 2.25M deep below ground level ) with top edge of the earth plate not less than 1.5M below ground level connected to GI strip 32 x 6mm thick for earthing lead fixed by means of nuts,bolt,washers etc connected to earth test point complete all as specified in electrical plate NO 3 of SSR 1996 part 1 including necessary excavation and earth work in any strata of soil,comman salt, charcoal dust, 40 mm dia light grade GI pipe for protection to earth lead, GI water pipe 20mm dia with funnel &wire mesh , PCC pit with CI cover and frame etc complete all as specified and directed by Engr-in-Charge. Note:- All the joints shall be made with welding to get proper conductivity. Note:- (a) All the joints shall be made with welding to get proper conductivity. (b) Earth strip GI 32 x6 mm shall be provided till the earth pit which may be beyond 7.5 mtrs.
XLPE insulated, armoured, aluminium conductor cable, 11000 volts grade, heavy duty, cross sectional area 120sq mm ,3 core, laid in trenches/ducts/through pipe complete all as specified and directed by Engr-in-Charge.
Cable jointing kit for 11 KV grade cable for out door termination heat shrinkable type joint complete with jointing material and acessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm complete all as specified and directed by Engr-in-Charge.
Excavation in trenches n. exc. 1.5 mtr in width and n. exc. 1.5 mtr in depth for laying of underground cable and getting out in soft/loose soil complete all as specified and directed by Engr-in-Charge.
Returning, filling in, excavated soil in trenches including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed by Engr-in-Charge.
Removing of excavated soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engr-in-Charge.
DWC Pipe ( Double wall corruguated) conforming to IS: 14930(Part-II) along with necessary Snap fit Coupler for interconnection Suitable for HT Cable of size 95 sq.mm (90X 76 mm as diameter) complete all as specified and directed by Engr-in-Charge. Make : Rex Poly extrusion / Tirupati
Cutting of existing road for laying of HT/LT Cables /MS/DI/CI/GI Pipes and making good the distrubued surfaces as equal to existing road finishes including refilling the excavated material, compacting , WBM and black top carpeting with biutemen & aggregate complete all as specified and directed by Engr-in-Charge.
Demolition of brick work or stone / boulder masonry, built in cement mortar, including all quoins, arches, pillars etc but excluding ashlar facing, dressed stone work and precast concrete articles etc complete all as specified and directed by Engr-in-Charge.
Demolition of cement concrete (unreinforced) in ground floor and in pavings not exceeding 15 cm thickness (below or above ground level) complete all as specified and directed by Engr-in-Charge.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed by Engr-in-Charge.
Brick work with sub-class 'B' bricks, straight or curved on plan exc. 6 m mean radius built in CM 1:6 complete all as specified and directed by Engr-in-Charge.
Providing plain cement concrete M-15, (1:2:4) type B-0 (using 12.5mm graded aggregate) as in roof kerbs, mud stops, roof padding etc using water proofing compound complete all as specified and directed. Note : Water proofing compound shall be paid separately.
Supply only liquid water proofing compound of approved quality, complete all as specified and directed by Engr-in-Charge.
APP based polymeric membrane minimum weighing 3 kg / sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt not less than 150 gms / sqm) laid on primed surface by forced application complete all as specified and directed by Engr-in-Charge.
Taking down chowkats or frames including shutters (w/o taking off shutters from the frames) exc. 1.50 sqm but n.exc. 4 sqm each and removing from site, complete all as specified and directed by Engr-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding but not backing, removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed by Engr-in-Charge.
Glazed ceramic coloured tiles 450mm x 350mm x 7mm thick as in vertical surfaces such as skirting dado etc set and jointed in neat cement slurry, pointed in white or coloured cement to match over and including 10mm thick rendering in cement mortar 1:4 to receive tiles, complete all as specified and directed by Engr-in-Charge.
Non skid coloured tiles, 7 to 8 mm thick area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over 15mm thick screed bed in CM 1:6, complete all as specified and directed by Engr-in-Charge.
100mm thick PCC, M-7.5 (1:4:8), type D-2, (using 40mm graded crushed stone aggregate) as in flooring, finished even and smooth without using extra cement with spike rolling to surfaces or making impression of expanded metal, whilst the concrete is green complete all as specified and directed by Engr-in-Charge.
50 mm thick plain cement concrete, M-10 (1:3:6), type C-2, (using 20mm graded aggregate) as in plinth protection finished fair & even without using extra cement, complete all as specified and directed by Engr-in-Charge.
Plain cement concrete, (Nominal Mix), M-10(1:3:6), type C-2, (using 40 mm graded crushed stone aggregates) as in surface channel and drain, complete all as specified and directed by Engr-in-Charge.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, incl forms, moulds, mitred / stopped ends etc, complete, complete all as specified and directed by Engr-in-Charge.
25 mm thick, plain cement concrete, M-15(1:2:4) (Nominal Mix), type B-0 (using 12.5 mm graded crushed stone aggregates) as in floors, finished rough surface to receive floor finishes, complete all as specified and directed by Engr-in-Charge.
Plain cement concrete, (Nominal mix), M-15(1:2:4) type B-1, (using 20mm graded crushed stone aggregates) as in cills, coping, apex stone, bed plates and lintel upto 1.6m clear span etc including weathering slightly rounded or chamfered angles and throating as directed including necessary form work,complete all as specified and directed by Engr-in-Charge.
Taking down cement plaster, any description, on brick or stone walls, etc. including raking out joints hacking for key, scrubbing down with water etc. complete all as specified and directed by Engr-in-Charge.
15 mm thick rendering on fair faces of brick or stone/concrete surfaces in cement mortar 1:4 and finished surface even and smooth without using extra cement complete with water proofing compound complete all as specified and directed by Engr-in-Charge. (WPC shall be measured separtely)
15 mm thick rendering on fair faces of brick /concrete surfaces in cement mortar 1:6 and finished even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge.
Applying two coats of oil bound distemper on walls after preparation of newly plastered surfaces over a coat of white primer, complete all as specified and directed by Engr-in-Charge.
Applying two coats of cement base paint on walls after preparation of newly plastered surfaces over a coat of white primer, complete all as specified and directed by Engr-in-Charge.
Mild steel framed work such as grills, gratings with ends of bars shouldered or reveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, frame work of water tanks and similar works, conforming to Fe-290, Gde E-165, complete all as specified and directed by Engr-in-Charge.
Rolled mild steel work of angle iron as in frames of doors & Cup Board etc conforming to grade Fe 410-O or Fe-310-O complete all as specified and directed by Engr-in-Charge.
GI frame work 605x605mm for seamless ceiling comprising of GI perimeter channel 0.55mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre / intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit / tie / purlins etc, at approx 900 mm centre to centre with GI cleat and steel suspenders of appropriate size fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre, including provision of 4 mm thick non-asbestos fibre cement board, ISI marked, fixed to snap grid frame works 605 x 605 mm as in ceiling, flat or sloppy as per manufacture's instructions, complete all as specified and directed by Engr-in-Charge.
Rolled mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment conforming to grade Fe.290.Gde-E-165, steel work duly painted with one shop coat of zinc chromate primer including preparation of surfaces complete all as specified and directed by Engr-in-Charge.
Anodized aluminium door frame of any shade with shutter of section 100mmx 45mm, thickness of sheet 3mm , partly panelled shutter and partly glazed lock rail / bottom rail of shutter 100mm x 45mm, top rail 80mm x 45mm including necessary jointing cleats, anodized aluminium including necessary fittings and aluminium mongeries i.e. 200mm long two Nos aluminium handles, 02 No, 200mm long aluminium tower bolt in each leaf, rubber gasket for securing the glass and 3 Nos 100 mm long butt hinges with each including 5 mm thick tinted glass and 12 mm thick Prelaminated Particle Board including mortice lock, hydraulic door closure to each shutter complete all as specified and as directed by Engr-in-Charge.
18/19 mm thick prelaminated particle boards bothsides with decorative choice laminations, grade-2 quality, interior grade, commercial type, fixed with screws as in shelves and shutters of cup board exposed face fixed with 20x6mm thick teak wood beading (in repair) complete all as specified and directed by Engr-in-Charge.
Mild steel continuous piano hinges, bright finish or electro galvanised, width of flap when open 30mm, complete all as specified and directed by Engr-in-Charge.
100 mm long aluminium anodised hasp and staple complete all as specified and directed by Engr-in-Charge.
2nd class soft wood beads, straight (any size) for glazed or gauzed joinery, renewed and cupboards shutters including miters etc.complete all as specified and directed by Engr-in-Charge.
Preparation of new steel surfaces of any description not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer, complete all as specified and directed by Engr-in-Charge.
GI steel water tubing, medium grade, 40 mm dia including fittings/ main/branch connections complete all as specified and directed by Engr-in-Charge.
All as per serial item no 45.00 here-in-before but 25mm dia.
All as per serial item no 45.00 here-in-before but 20mm dia.
Gun-metal, globe or gate valves, 40mm dia , heavy duty, with iron wheel head, screwed both ends (ISI marked), complete all as specified & directed by Engr-in-Charge.
Gun-metal, globe or gate valves, 25mm dia , heavy duty, with iron wheel head, screwed both ends (ISI marked), complete all as specified & directed by Engr-in-Charge.
Cutting of GI fittings heavy duty ISI marked including neccessary screwing, welding etc complete all as specified and directed by Engr-in-Charge.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .