Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.6 LAccepted-AOC NEAR PAYAL CINEMA P O SEVOKE ROAD SILIGURI 734 001 | DARJEELING | WEST BENGAL | 734001 | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹47.9 L+₹89,048 (1.89%)Rejected-Finance KHAWASNIWAS NEAR POLICE QTRDEORALI GANGTOK SIKKIM | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹48.4 L+₹1.3 L (2.83%)Rejected-Finance SIMULBARI T E PO VILL SIMULBARI PS KURSEONG DIST DARJEELING PIN 734009 WEST BENGAL | SIMULBARI | DARJEELING | WEST BENGAL | 734009 | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹48.7 L+₹1.6 L (3.42%)Rejected-Finance | L4 | Rejected-Finance Not Lowest Bidder | |
| 5 | L5₹49.1 L+₹2.1 L (4.39%)Rejected-Finance | L5 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
30 Nov 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer Sukna
Garrison Engineer Sukna, Post-Simulbari, Dist.-Darjeeling, WB-734009
REPAIR AND MAINT OF BOREWELL, STARTERS AND ALLIED WORKS UNDER AGE E/M OF GE SUKNA
2023_MES_627380_1
GE Sukna/8609
Open Tender
Civil Works
Works
270 days
Sukna
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE Sukna
₹90,000
Yes
9 Mar 2024
8 Nov 2023
1 Dec 2023
8 Nov 2023
30 Nov 2023
23 Nov 2023
9 Nov 2023 - 30 Nov 2023
Amount
Taking up submersible pump assembly of capacity 10 to 15 HP with and including column pipe of approximate 50 to 80 m length from borewell using chain pulley block manually, transporting to workshop and back including dismantling, taking out burnt winding wire, rewinding using super enamelled insulated copper winding wire of appropriate gauge and turn, providing insulation materials and assembling, air washing lowering complete assembly and electrically connecting complete all as specified and directed.
S&F in repairs 80 mm bore & 3 m long MS heavy duty seamless black column pipe with both ends flanged, wall thickness not less than 5.4 mm in borewell with and including all jointing materials such as nut, bolts, washers, rubber gasket etc. complete all as specified and directed. Make - Tata / Jindal
M&L for development of tube / bore well with air compressor of suitable capacity till sand / mud free water of potable quality is obtained and to achieve minimum discharge capacity of 3600 LPH / max yield complete all as specified and directed. Note:- Compressor with acessories & tubes etc. shall be arrranged by the contractor and deemed to be included with the quoted rate. Make:- Kirloskar / KSB / Crompton greaves
Supply, lowering, installation, testing and commissioning of submersible pump set complete with 3 phase submersible electric motor coupled with the pump having capacity 11 KW/15 HP , 7 stage or as per OEM recommended stage suitable for coloum pipe/ outlet pipe of 80mm dia fixing with existing coloumn pipe at site including taking out u/s pump complete all as specified and directed. Note : U/s Pump shall be deposited to MES storeyard without any extra cost. Make:- Kirloskar / KSB / Crompton greaves
Supply, lowering, installation, testing and commissioning of submersible pump set complete with 3 phase submersible electric motor coupled with the pump having capacity 7.5 KW/10 HP , 4 stage or as per OEM recommended stage suitable for coloum pipe/ outlet pipe of 80mm dia fixing with existing coloumn pipe at site complete all as specified and as directed. Note:Taking out of old submersile pump including column pipe and lowering of new pump shall be included in quoted unit rate. U/s Pump shall be deposited to MES storeyard without any extra cost. Make:- Kirloskar / KSB / Crompton greaves
Supplying, fixing and jointing of Cast iron NRV, ISI marked, in replacement, Class PN-1.6 with flanged and drilled ends, suitable for 80mm nominal bore pipe / fittings including joints and jointing materials such as bolt, nuts, washers and rubber gasket etc complete all as specified & directed. Make:- Kirloskar / KSB / Crompton greaves
Supply and fixing Fully Automatic 10 HP/7.5 KW (Centrifugal Pump Starter) Star Delta, 3-Phase, Pump Starter having following. Contactor Rating- 25 A, 4 Pole (3P+1Aux) Contactor with silver cadmium low bounce designed contact tips and 380-415 V AC (Operating Band -15% - +10%) totally encapsulated based moisture proof long life magnet coil. Type- NA25N. Electronic Micro-Processer based Overcurrent Relay range (3 – 30Amp) BOCR SS 30 - with built in Over Current, Locked Rotor, Phase Loss protection. Short Circuit protection through suitable MCB. Suitable rating of Analogue type with Amp-meter and Voltmeter with suppressed scale. Indications- LED type three phase indication R-Y-B and motor On and Trip. Enclosure- 180-degree opening angle 12 tank process powder coated enclosure with PU Foam gasketing and with SS mounting plate. Provision for connecting Dry Run prevention. Make BCH cat NO - NASASS30LEN-P-MCB or Equivalent / Havells / L&T / ABB / complete all as directed and as specified by Engineer-in-Charge.
All as per serial item No 07 here-in-before but suitable for 15 HP / 11 KW Make :- BCH / Havells / L&T / ABB
All as per serial item No 07 here-in-before but suitable for 25 HP / 18.5 KW Make :- BCH / Havells / L&T / ABB
Supply and fixing Fully Automatic 30 HP / 22 KW(Centrifugal Pump Starter) Star Delta, 3-Phase, Pump Starter having following. Contactor Rating- 40A, 3 Pole D type Citation Contactor with silver cadmium low bounce designed contact tips and 380-415 V AC (Operating Band -15% - +10%) totally encapsulated based moisture proof long life magnet coil. Type- MC10DN22M. Electronic Micro-Processer based Overcurrent Relay range (5 – 60Amp) BOCR SS 60 - with built in Over Current, Locked Rotor, Phase Loss protection. Suitable rating of Analogue type with Amp-meter and Voltmeter with suppressed scale. Indications- LED type three phase indication R-Y-B and motor On and Trip. Enclosure- 180-degree opening angle 12 tank process powder coated enclosure with PU Foam gasketing and with SS mounting plate. Provision for connecting Dry Run prevention. Make BCH CAT NO – NASASS60LEDM-P or Equivalent complete / Havells / L&T / ABB / all as directed and as specified by Engineer-in-Charge.
All as per serial item No 10 here-in-before but suitable for 60 HP / 44 KW Make :- BCH / Havells / L&T / ABB
Supply and fixing in repair power contactor 415 volt, 50 cycles, 3 phase, type MNX 40 complete all as specified and as directed by Engineer-in-charge. Make :- BCH / Havells / L&T / ABB
Supply and fixing in repair power contactor 415 volt, 50 cycles, 3 phase, type MNX 32 complete all as specified and as directed by Engineer-in-charge. Make :- BCH / Havells / L&T / ABB
S&F in repair bimetal over load relay single phase protection directly mounted 28 to 42 Amps, range ML2/ML3 complete all as specified and as directed by Engineer-in-charge. Make :- BCH / Havells / L&T / ABB
Supply and fixing in repair electronic timer (time delay relay) of range 12-120 sec, input voltage 220 to 240 volts AC complete all as specified and as directed by Engineer-in-charge Make :- L&T / ABB / BCH / Simens
Material and labour for preparing the old painted steel and iron surfaces of any description not otherwise described or in any position and applying of two coat of black bituminous paint over one coat of red oxide primer (suitable for drinking water), complete all as directed and as specified by Engineer-in-Charge.
Material and labour for three core flat submersible cables in replacement of size 10 Sq mm with bare bunched copper conductor insulated with PVC and sheathed with PVC for Submersible Pump Motors with voltage grade upto 1100 V generally conforming to IS 694:1990, complete all as directed and as specified by Engineer-in-Charge. Make : Finolex/Havells/R R Kabel/Polycab.
Material and labour for three core flat submersible cables in replacement of size 6 Sq mm with bare bunched copper conductor insulated with PVC and sheathed with PVC for Submersible Pump Motors with voltage grade upto 1100 V generally conforming to IS 694:1990, complete all as directed and as specified by Engineer-in-Charge. Make : Finolex/Havells/R R Kabel/Polycab.
M&L testing of water from approved government recognized laboratory and submitting the test report as per IS 10500 : 2012 for following parameters and indicating permissible vaue, results and recommendation (Location :- Hopper tank,Madhuban P/H,Swimming phool,33 Corps P/H,Map-1&11P/H,SSV&Monoj pandey P/H,1880 RKT P/H,12 Para P/H,15Mhar P/H,Taranjubari P/H,5033Asc P/H,63mdn bdg P/H,4033 TRH P/H etc. complete all as specified and directed:- (a) Turbidity (b) PH value (c) TDS (d) Colour (e) Iron (f) Chlorine (g) Fluoride (h) Total Hardness(mg/I) (i) Total Alkalinity(mg/I) (j) Nitrate(mg/I) (k) Copper(mg/I) (l) Total coliform Present/Absent MPN(per 100ml) (m) Faecal coliform Present/Absent MPN(per 100ml) (n) Water bacteriologically safe/unsafe (o) Lead(as pb),mg/I Max(IS-3025 part-47) (p) E.coil or thermotolerant coliform bacteria(IS-1622:2009) Note:- The water testing report every month 1st week duly submitted with out fail above the location.
Materials and labour for preparing old painted steel pipe outer surfaces such as rising pipe (Red), delivery pipe (Blue), overflow pipe and wash out pipe (Yellow), etc and applying two coat of synthetic enamel paint for 80/100/150mm bore pipe complete all as specified and as directed.
Supply and fixing Pressure booster pump with automatic pump controller 1HP ,240Volt,50HZ single phase maximum flow rate 3050ltr per hour,low noice ,good pressure,including all connected items etc and all as directed by Engr-in-Charge. Make : KSB / CG / CRI
Supply and fixing wooden brush (size:2m -length) for suction swipper of swimming pool.
M & L for earthing complete with GI earth plate electrode of size 60 cm x 60 cm x 6 mm thick buried directly in ground vertically at a depth not less than 2.25 mtr below normal ground level with top edge of earth plate at depth not less than 1.5 mtr below normal ground level surrounded from all sides by 15 cm thick and packed layer of charcol dust and common salt filling in alternate layers and electrode connected by galvanised iron strip 32 mm x 6 mm by means of bolts, nuts, check nuts and washers connected to test termination point protected by 40mm bore GI pipe light grade and GI pipe light grade 20mm bore for watering and including funnel, wire mesh, RCC pit cover and PCC chamber pit with PCC 1:2:4 type B1 including excavation and earth work, disposal of surplus soil to a distance not exceeding 50 mtr all as specified and shown in electrical plate No 3 of SSR Part I complete all as specified and directed. Note-- (i) The unit rate shall include for GI water pipe, protection pipe wire mesh, funnel, excavation, RCC pit cover, PCC, test point, G I strip 32 X 6 mm from top of earth plate upto 5 mtr (ii) PCC pit shall be provided at least 1.5m away from the earth pit and extra cost of additional length of water pipes and fixing junction, Elbows etc. shall be deemed to be included in the unit rate. (iii) RCC pit cover shall be percast of RCC 1:2:4, type B-1, 80 mm thick reinforced with XPM weighing not less than 4kg/Sqm in liue of cast iron cover complete all as specified and directed.
M/S S. S CHETTRI AND SONS
R N SAH N CO
MOURICE CONSTRUCTION COMPANY
GEETA CONSTRUCTION
M/S G S ASSOCIATES
M/S GLORIOUS CONSTRUCTION
D K SARKAR
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .