Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.5 LAccepted-AOC 602 TECHNOLOGY APARTMENTS 24 1 P EXTENSION DELHI 110092 | DELHI | DELHI | DELHI | 110092 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹13.2 L+₹1.8 L (15.3%)Rejected-Finance 61 ABHAY GARH SCHEME AIR FORCE JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹14.4 L+₹3.0 L (25.8%)Rejected-Finance 190 B VIJAY BHAWAN SUBHASH CHOWK RATANADA JODHPUR RAJ 342001 | JODHPUR | RAJASTHAN | 342001 | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹14.9 L+₹3.4 L (29.4%)Rejected-Finance | L4 | Rejected-Finance Not Lowest Bidder | |
| 5 | L5₹15.4 L+₹3.9 L (34.3%)Rejected-Finance 202 NEW RAM VIHAR COLONY PINTO PARK MORAR GWALIOR 474005 | GWALIOR | GWALIOR | MP | 474005 | L5 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹14 L
EMD Value
₹28,000
Closing Date
22 Aug 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) JAISALMER
GE (AF) JAISALMER
Provn of Geysers and Associated items and Certain Minor works at Air Force Station Jaisalmer
2020_MES_364565_1
8681/GE/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (AF) JAISALMER
As per Tender documents
6 documents required · 6 mandatory
₹500
GE (AF) JAISALMER
₹28,000
Yes
8 Sept 2020
27 Jul 2020
24 Aug 2020
27 Jul 2020
22 Aug 2020
10 Aug 2020
60 days
Amount
S&F water heater storage type, electric capacity 25 litre BEE 5 star rated complete all as specified. Make : Havells/Bajaj/CG
M&L for hot water gun metal globe valve/safety valve 15mm bore complete all as specified. Make : Zoloto/Leader/Venus/Sant
M&L for Hot water tap of brass/gun metal 15mm bore complete all as specified.
M&L for galvanized steel water tubing medium grade of 15mm bore with & including all necessary fittings complete, to walls and ceilings or laid in floors complete all as specified and directed.
M&L for Hot water PVC connections 15mm size with PTMT nuts of length 450mm for geysers including necessary clamps, nuts and bolts complete all as specified and directed.
M&L for Sub main wiring with 2x4 sqmm, single core, PVC insulated unsheathed multistranded copper conductor FRLS 1100 volts grade conforming to IS 694 including and 4.00 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour including drawn through in 25mm dia PVC conduit complete all as specified and directed. Note : Two run of 4.00 sqmm cable and one run of 4.00 sqmm cable as earth wire continuity conductor and one run 25mm dia PVC conduit shall be measured & paid as one unit.
S&F capacity 10 to 20 Amp, metal clad box with top plug and socket, including 20 Amp, MCB SPN complete all as specified and directed by Engr-in-Charge. Make Siemens Cat Part No. 8GB0501RC and equivalent Havells.
S&F MCB, SP 6 to 32 Amps rating, with over load and short circuit protection 'C' curve and rupturing capacity 10 kA, 410 Volt grade, AC, 50 Hz and making connections using suitable size copper lugs/thimbles, complete all as specified & directed. Make : Legrand Cat Part No. 4085 95 or Seimens/Havells/ABB
S&F UV Filter of capacity 20 watt complete with Lamp suitable for RO Plant of Capacity 1000 LPH.
S&F UV Filter of capacity 40 watt complete with Lamp suitable for RO Plant of Capacity 3000 LPH.
S&F UV Lamp for UV Filter of Capacity 20 watt sutiable for RO of Capacity 1000 LPH.
S&F UV Lamp for UV Filter of Capacity 40 watt sutiable for RO of Capacity 3000 LPH.
S&F Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32 x 6mm galvanised strip complete all as specified. Note : Nut, bolt and other items included in quoted rate by the tenderer.)
Supply and fixing single pointed air termination aluminium rod 12mm dia and 300mm long and fixing to GI pipe with clamps, nuts, bolts and washers complete all as specified
S&F steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-64 (12.00 mtr long) including painting of poles with two coats of synthetic enamel paint over a coat of primer with black and white strips 30cm wide each upto 1.5mtr height from top of PCC foundation block and numbering of poles, including necessary excavation, return filling & removal complete all as specified and directed
M&L for Earthing complete with galvanished earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of plate not less than 1.5 deep below normal ground level and connected to galvanished iron earth lead strip 32mmx6mm upto 7.50 metre, by means of GI nuts, bolt, check nuts, washers, thimbles, etc as shown in electrical plate No 5 SSR Part-I and connection to main switch board or panel and testing on completion including excavation and earth work in any type to soil, returning fitting in and removal of surface spoil to a distance not exceeding 50 metre, PCC chamber (1:3:6) type C-2, charcoal and salt mixed layer 15cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe light grade 20mm bore for watering and 50mm bore GI pipe light grade for earth wire protection fixed with poles with two clamps, made from earth lead strip 32mm x 6mm, bolts, nuts and washers, 80mm thick pre cast RCC cover 1:2:4, type B-1, reinforced with hard drawn steel wire fabric wieghing not less than 4 Kg/Sqm in lieu of CI cover etc complete all as specified. Note : (i) The unit rate shall be deemed to included for Test point, 32mmx6mm GI strip from top of the earth plate upto 7.50m above ground level. In case, GI protection pipe required is less than 7.50m, no price adjustment shall be made. (ii) PCC pit shall be provided at least 500mm away from the earth pit and not just on the earth pit and extra cost of additional length of water pipes and fittings, junctions, elbow etc shall be deemed to be included in the unit rate quoted by the tenderer.
Supply and fixing 2 KVA invertor system comercial power supply establishments have higher power needs. Also frequent power cuts can hamper the overall performance of the applications. Luminous higher 2 KVA invertor and 4 battery 12 volts, 180 AHU capacity, Lead Acid Battery, system offers high quality and reliable power backup solution for running office and sensitive equipments 180 to 240 volts for instrument and three input and three out put with one year warranty, including initial charging and connecting DC cable, thimbles, nut, bolts, complete all as specified and directed. Make : Exide / Amco / Microtex / Amron / Sukam / Okaya
S&F installation, testing and commissioning of multi criteria heat cum smoke detector operating principle of light ray disturbance conforming to IS-2189 complete with base plate UL, MF UPCB approved complete all as specified.
S&F installation, testing & commissioning of zonal indicator panel of upto 2 zone having provision of audio/vedio indications for Fire, Fault, Open/Short Earth Circuit duly interfaced with main control panel complete all as specified and directed.
S&F installation, testing & commissioning of response indicators made from 1.6mm thick CRCA sheet having dual red LED indication & provision for cable wire entry from top complete all as specified and directed.
S&F installation, testing & commissioning of manual call box (Pill box) made from 16 SWG CRCA sheet having single LED indication & release type push botton in case of Fire Break Glass printed on front cover & having hammer & chain complete all as specified.
S&F installation, testing & commissioning of medium intensity electronic hooter (Siren) cum speaker made from 16 SWG CRCA sheet with circuit having an out of 80 DB & printed Fire Alarm complete all as specified.
M&L for 2x1.5 sqmm, single core, PVC insulated and unsheathed multi stranded copper conductor FRLS cable FRLS 1100 volts grade conforming to IS 694 complete all as specified.
M&L for 2x4 sqmm, single core, PVC insulated and unsheathed multi stranded copper conductor FRLS cable FRLS 1100 volts grade conforming to IS 694 complete all as specified.
S&F steel conduit heavy duty 25mm dia
M&L for Test point terminal block Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos, 8mm dia, 25mm long hexaguanal head screw complete all as specified and directed by Engr -In-Charge.
M&L for PCC (1:4:8) Type D-2 (using 40mm graded stone aggregate) in foundations, filling and mass concrete for foundation of walls complete all as specified and directed.
M&L for plain cement concrete (1:3:6) Type C-2 (using 40 mm graded granite stone aggregate) in foundations, filling and mass concrete for foundation of walls complete all as specified and directed.
SANJOLI CONSTRUCTION COMPANY
M/S Balkishan Panwar Construction
Siddharth Constructions
M/S AUTOMATION AND SWITCHGEAR CONTROL
M/s Shree Construction Company
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .