Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.0 LAccepted-AOC | L1 | Accepted-AOC BEING L1 AND REASONABLE | |
| 2 | L2₹36.7 L+₹56,820.70 (1.57%)Rejected-Finance | L2 | Rejected-Finance DUE TO NOT BEING L1 AND REASONABLE | |
| 3 | L3₹37.7 L+₹1.5 L (4.12%)Rejected-Finance | L3 | Rejected-Finance DUE TO NOT BEING L1 AND REASONABLE | |
| 4 | L4₹38.8 L+₹2.6 L (7.16%)Rejected-Finance | L4 | Rejected-Finance DUE TO NOT BEING L1 AND REASONABLE | |
| 5 | L5₹39.1 L+₹2.9 L (8.12%)Rejected-Finance 397 JASPREET SALUJA INDORE VISHNUPURI ANNEX INDORE MADHYA PRADESH 452001 | INDORE | MADHYA PRADESH | 452001 | L5 | Rejected-Finance DUE TO NOT BEING L1 AND REASONABLE |
Tender Value
₹34 L
EMD Value
₹68,000
Closing Date
14 Mar 2022, 6:00 pmClosed
GE SOUTH AKHNOOR
GE SOUTH AKHNOOR C/O 56 APO
REPAIR TO PUMP SETS, MOTORS, DG SETS, VOLTAGE STABILIZER AND MISCELLANEOUS ITEMS, REPAIR AND MAINT OT CHLORINE DOZING PUMPS, REPAIR AND MAINT OF AIR CONDITIONER INCL CONNECTED ITEMS AND REPAIR MAINT OF HIGH MAST LIGHTS UNDER GE SOUTH) AKKNOOR.
2022_MES_509481_1
GES/AKH-74/2021-22
Open Tender
Civil Works
Item Rate
240 days
GE SOUTH AKHNOOR
MES EN-LISTED CONTRACTOR WITH CLASS D AND ABOVE AND CATEGORY a(ii) and b(i)
9 documents required · 9 mandatory
₹500
GE SOUTH AKHNOOR
₹68,000
31 Mar 2022
21 Feb 2022
16 Mar 2022
21 Feb 2022
14 Mar 2022
28 Feb 2022
Amount
Dismantling and taking down deffective high mast light fittings with complete assembly by engaging suitable heavy duty crane/ Hydra machine from pole upto 20 mtr height using electrically operated winch, repairing and refixing after replacing all unserviceable parts including internal wiring complete all as specified and directed by Engineer-in-Charge. (Note : (a) Light fittings shall be measured and paid for separately. (b) Spares such as steel wire, winch motor, cable etc shall be measured and paid for separately. c) The entire work shall be carried out by well experienced professionals who has already carried out the high mast poles dismantling /repair works and similar works. d) Cost Minor fittings/fixtures such as screws, bolt/nuts, grease etc shall provided by the contractor without any extra cost to the Govt to make fucntional lights and nothing shall be admissible on this ground.
Supply only stainless steel rope twisted of size 10 mm dia with necessary connections proper binding on both sides from bottom drum to high mast top connection hook , complete all as specified and directed by Engineer-in-Charge.
Supply only fractional 1.5 HP motor 415 volts suitable for electrically operated high mast light, complete all as specified and directed by Engineer-in-Charge.
Supply only PVC insulated, PVC sheathed multistranded copper conductor cable of size 4.00 sqmm 4 core , complete all as specified and directed by Engineer-in-Charge.
Supply only Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP66 flood light 150W, suitable for highlighting architectural facade and general purpose lighting along with connected accessories complete all as specified and directed Make :- Havells Cat Part No JETAIRISFLS 150WLED757PSYMLTG/Crompton Cat Part No LFLN-150-CDL/60 or Equivalent in Philips.
Supply only Integral LED aviation light fittings Integral LED aviation light comprising of aluminium housing with polycarbonate enclosure Make : Bajaj Cat Part No BGAV 302 LED or equivalent in Crompton/ Havells/Philips
Disconnecting and taking down the existing perimeter light fittings from poles of any type or any make for cleaning by removing the dusts, insects from the inside of compartment, repair/replacement of unsv spares and re- fixing the same complete all on the directed by Engr-in-Charge ( Note - Spare parts will be measured and paid for seperately.)
Supply only electronic LED driver for LED light fittings, capacity 45/ 50 Watt, 50Hz, complete all as specified and directed by Engineer-In-Charge. (Make: Havells/ Crompton Greaves/ Bajaj/ Wipro/ Phillips/ Surya/ Bajaj/ C&S).
Supply only electronic LED driver for LED light fittings, capacity 60 Watt, 50Hz, complete all as specified and directed by Engineer-In-Charge. (Make: Havells/ Crompton Greaves/ Bajaj/ Wipro/ Phillips/ Surya/ Bajaj/ C&S).
Supply only LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP OPENING seperate driver compartment with IP66 protection and impact resistance of IK07 with 10KV Built-in surge protection device, including LED lamps of 60 Watt all as specified and as directed by Engr-in-Charge Make: Havells cat part No- Endura Pearl Plus SL60WLED757SASYTOPC/ Philips ordering code No- 910925865969 (Product Code- 871869632029700)/ Wipro cat part No- LR02-671-XXX-57-G2.
Supply and fixing in repalcement bracket made out of GI pipe 1.5 Mtr long, 40 mm dia light grade bent to shape as directed including clamps made out of 40 mm x 6 mm flat for fixing bracket suitable for PCC poles including nuts and bolts, washers and other connected items of required size including painting with one coat of aluminium paint over a coat of red oxide/primer all as specified and as directed.
Disconnecting and taking down the existing unserviceable post top lantern/ gate/ garden light fittings from gates/ poles of any type or any make for cleaning by removing the dusts, insects from the inside of compartment, repair/replacement of unsv spares and re- fixing the same complete all on the directed by Engr-in-Charge Note - (a) Spare parts will be measured and paid for seperately. (b) Necessary dismantling and new PCC work /touch up work if required to make existing surface as existing etc shall deemed to be included in the quoted rates.
Supply only LED Bollard light fittings 10 W IP65 protection with robust design and efficient light distribution, complete all as specified and directed by Engineer-in-Charge. Make : Crompton cat No LBLTW-10-CDL or equivalent in Osram/Havells/Philips
Supply only pole mounted LED Post Top lantern ideal to lit up parks, garden ways and heritage sites and efficient light distribution with IP65 protection of capacity 20 watt mounted on existing Pipe 40/50 mm dia all as directed Make : Crompton cat No LPTH-20-CDLor equivalent in Osram/Havells/Philips
Supply only gate light LED post top 15 watt , new generation, energy saving long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs Ruby clear suitable for mounting on existing Brick pillar gates/ poles on existing pipe of 40/50 mm dia all as directed Make : Havells Cat No RUBYMINIPT15WLED757PSYMTOPC or equivalent in Crompton/ Philips
Supply only GI pipe light grade of size 40 mm dia of any height mounted on PCC fdn at existing position all as directed by Engr-in-Charge (Note: PCC measured and paid separately)
Supply only GI pipe light grade of size 50 mm dia of any height mounted on PCC fdn at existing position all as directed by Engr-in-Charge. (Note: PCC measured and paid separately)
Taking down existing solar street light fittings with solar panel from poles, cleaning the solar panel, removing burnt/ damage sensor, battery and auto system from battery box, repair the wiring with copper wire of suitable size including replacement of spares all as directed (Spares parts will be measured and paid separately
Supply only Solar plate of capacity 200 watt in suitable size as per existing panel, complete all on the directed by Engr-in-Charge
Supply only LMLA battery, 12 Volts 60 AH with end terminal of suitable size, complete all on the directed by Engr-in-Charge
Supply only automatic time sensor including internal connection cable of suitable size, complete all on the directed by Engr-in-Charge
Replacement of XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area of size 10 Sq mm, 4 core all as directed
Replacement of XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area of size 10 Sq mm, 2 core all as directed
Replacement of XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area of size 6 Sq mm, 2 core all as directed
Excavation in trenches in any type of soil not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cable,erection of poles, stays, pipes etc and not exceeding 10sqm on plan and getting out all as directed.
Returning, filling in any type of soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm all as specified.
Removal of excavated material n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above in starting point.
Sand cushioning to protection of underground cables, laid 8 CM before laying and 15 CM after laying of cable, and punned to form an overall layer of 18 Cm thick, complete all as specified and directed by Engineer-In-Charge. (Note: Punned thickness shall be measured).
Sub class ‘B’ bricks, modular size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning for mechanical protection of cable, with width equal to the length of the brick, complete all as specified and directed by Engineer-In-Charge.
M&L PCC 1:4:8 type D-2 using 40 mm graded aggrgate for filling in foundations of LT poles/garden light fittings all as directed.
Replacement of PVC junction box of size 140MMx140MMx95MM mounted on GI pipe with MS clamp made out of 40 mm x 6 mm flat for fixing box on pole/wall including terminal point mounted on epoxy insulator for cable connection with 01 No MCB SP 10 amps complete all as directed
Replacement of automatic timer switch astronomical type of capacity 32 amps 230 volts suitable for controlling of light fittings all as directed by Engr-in-Charge. Make : Indoasian cat No TL032ASO or equivalent of Bajaj
Earthing complete with galvanised steel earth plate electrode 60 cm x 60cmx6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level. connecting to the GI wire 4 mm dia by means of bolls, nuts, check nuts and washers of galvanised iron and earth wire protected by provision of GI light grade pipe 15 mm bore including provision of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM weight not less than 4 Kg/Sqm) and frame of angle iron 25x25x6mm with lugs 02 Nos and handle of 6mm dia MS bar made to shape, GI medium grade 20mm bore pipe for watering , perforated at bottom. 1.75 metre long placed on top edge of earth plate. charcoal and common salt filling with fixing arrangement, funnel wire mesh and earth work in soft soil returning filling in and removal of surplus soil to a distance not exceeding 50 meters all as per electrical plate 3 of SSR-2009 Part-I and connecting to earth test point all as specified or indicated including testing on completion. NOTE :- (i) Item of earthing includes cost of 7.5 m long GI wire of size 4 mm dia with protection pipe of 15mm dia GI medium grade, any variation in length shall be adjusted through deviation order based on SSR rates -2020 Reduced by (-25%). (ii) On testing after completion of earthing if the desired earth resistance is not obtained earthing will be re-done by the contractor at his own risk and cost.
Disconnecting all electric connections from alternator and fuel connection from engine, decoupling of engine and alternator, strip opening of diesel driven generator of capacity 30 KVA for repair, complete for carrying out overhauling after de-assembling the engine assembly, cleaning/washing the engine block and other spares parts replacement defective parts with new spare parts as required for smooth functioning of diesel engine and strip opening of alternator for repair and replacement of old defective spare parts, metalling, welding, grinding, lathe machine work required at workshop including re-assembling the engine in existing position or a location as directed complete and testing on load all as specified and as directed by Engr-in-Charge. Note : (a) New spare parts will be measured and paid separately as supply only under the respective items. (b) Cost of cleaning, welding, minor repair and special tools and plants required for dismantling engine will deemed to be included in quoted rate. (c) Transportation cost of diesel engine/ alternator to workshop and return back shall deemed included in quoted rate.
Supply only following new spare parts required for DG set and alternator of capacity 30 KVA (a) Linear piston Ring set
(b) Valve guide set
(c) Main Le Bearing
(d) Big end Bearing set
(e) Engine packing kit
(g) Engine oil
(h) Diesel filter
(j) Lub Oil filter
(k) Oil pump set complete
(l) Oil seal set
(m) Head gasket
(n) Fan belt
(o) Thrust washer set
(p) Self starter assy
(q) Connecting rod bush
(r) Charging alternator
(s) Hose pipe set
(t) ignition switch
(u) Volt meter
(v) ammeter
(w) Coolant fluid suitable for radiator of DG set
Dismantling or taking up defective/ damaged submersible pump sets with lowering pipe, flange or any type and any size of any depth with pump set of any capacities by manual or mechanical means after disconnecting the all electric connections from LT panel or starter and transport to workshop for repair and workshop to sites after repairing, complete all as specified and directed by Engineer-In-Charge. Note: (i) Cost of tools and plants for taking out, minor spare parts such as nuts, bolt, washers, lubricants and transportation to workshop shall be deemed included in quoted rate.
De-assemble submersible pumps of capacities 20 HP to 55 HP, discharge 7500 to 35000 gallons per hours and 90 Mtrs head height, for repair and re-assembling the same after necessary repair/ replacement of old defective/ damaged spare parts of existing makes and specifications, complete all as specified and directed by Engineer-In-Charge. Note: (i) Cost of new spare parts will be measured and paid separately under respective items. (ii) Cost of tools and plants, transportation to workshop shall be deemed included in quoted rate.
Supply only following new spare parts required for replacement for repairsubmersible pumps of capacities 20 HP to 55 HP, discharge 7500 to 35000 gallons per hours and 120 Mtrs head height :- (a) Gun metal impellers
(b)Gun metal bushes
(c) Stainless steel shaft/ distance sleeve.
(d) Neck ring Gun metal
(e) Pump and motor stainless steel coupling
(f) Key stainless steel for coupling
(g) Thrust plate set
(h) Cable seal rubber
(j) Gun metal stud and nuts for connection piece
(k) Cast iron bowl assembly
Repair to pump shaft to its original shape by remetaling, turning, cutting and grinding.
Repair to rotor assembly to its original shape by remetaling, turning, cutting and grinding.
De-assemble submersible pump of capacity 5.0 HP, for repair and re-assembling the same after necessary repair/ replacement of old defective/ damaged spare parts of existing makes and specifications, complete all as specified and directed by Engineer-In-Charge. Note: (i) Cost of new spare parts will be measured and paid separately under respective items. (ii) Cost of tools and plants, transportation to workshop shall be deemed included in quoted rate.
Supply only following new spare parts required for replacement for repairsubmersible pump of capacity 5.0 HP :- (a) Gun metal impellers
(a) Gun metal bushes
(b) Stainless steel shaft/ distance sleeve.
(c) Neck ring Gun metal
(d) Pump and motor stainless steel coupling
(e) Key stainless steel for coupling
(f) Thrust plate set
(g) Cable seal rubber
(h) Stainless steel rotor shaft/ bush sleeve with bronze bush
(j) Cast iron bowl assembly
(k) T-bolt of motor
Repair to pump shaft to its original shape by remetaling, turning, cutting and grinding.
Repair to rotor assembly to its original shape by remetaling, turning, cutting and grinding.
Disconnecting all electric, water supply and coupling connections between motor, centrifugal pump, capacity 100 HP/ 200 HP and delivery line including de-assemble and removal from foundation, of defective centrifugal pumps by mechanical or manual means including gland assembly/ housing, any capacity and type, for repairing transportion to workshop if required, and re-assembling, installation, commissioning after necessary repair/ replacement of old defective/ damaged spare parts and greasing to different parts, testing the same pump on full load including one coat of spray painting on outer surfaces, matching to existing colour, writing SM/ MES No. and date of servicing/ repair with white paint, complete all as specified and directed by Engineer-In-Charge. Note: (i) Cost of tools and plants for taking out, minor spare parts such as nuts, bolt, washers, lubricants and transportation to workshop shall be deemed included in quoted rate.
Disconnecting all electric, water supply and coupling connections between motor, centrifugal pump, capacity 5HP and delivery line including de-assemble and removal from foundation, of defective centrifugal pumps by mechanical or manual means including gland assembly/ housing, any capacity and type, for repairing transportation to workshop if required, and re-assembling, installation, commissioning after necessary repair/ replacement of old defective/ damaged spare parts and greasing to different parts, testing the same pump on full load including one coat of spray painting on outer surfaces, matching to existing colour, writing SM/ MES No. and date of servicing/ repair with white paint, complete all as specified and directed by Engineer-In-Charge. Note: (i) Cost of tools and plants for taking out, minor spare parts such as nuts, bolt, washers, lubricants and transportation to workshop shall be deemed included in quoted rate.
De-assemble centrifugal pumps of capacities 100 HP/ 200 HP, discharge 25000 gallons per hours and 500 feet head height, for repair and re-assembling the same after necessary repair/ replacement of old defective/ damaged spare parts of existing makes and specifications, complete all as specified and directed by Engineer-In-Charge. Note: (i) Cost of new spare parts will be measured and paid separately under respective items. (ii) Cost of tools and plants, transportation to workshop shall be deemed included in quoted rate.
Supply only following new spare parts required for replacement for repair of centrifugal pumps of capacities 100 HP/ 200 HP, discharge 25000 gallons per hours and 500 feet head height :- (a) Cast iron impeller
(a) Neck ring Gun metal
(b) Body bush gun metal
(c) Cast iron diffuser rings
(d) Bearing housing
(e) Cast iron gland bush
(f) Gun metal lubricating pipe
(g) Ball bearing of existing specifications, ISI marked.
(h) Stay rod iron
(j) Coupling set with plate, bush, nuts, bolts and washers
(k) Key stainless steel for coupling
(l) Air release valve/ cock of brass
Repair to pump shaft to its original shape by remetaling, turning, cutting and grinding and making bearing/ bush housing
De-assemble centrifugal pumps of capacity 5 HP, for repair and re-assembling the same after necessary repair/ replacement of old defective/ damaged spare parts of existing makes and specifications, complete all as specified and directed by Engineer-In-Charge. Note: (i) Cost of new spare parts will be measured and paid separately under respective items. (ii) Cost of tools and plants, transportation to workshop shall be deemed included in quoted rate.
Supply only following new spare parts required for replacement for repair of centrifugal pump of capacity 5 HP :- (a) Cast iron impeller
(b) Neck ring Gun metal
(c) Body bush gun metal
(d) Cast iron diffuser rings
(e) Bearing housing
(f) Cast iron gland bush
(g) Gun metal lubricating pipe
(h) Ball bearing of existing specifications, ISI marked.
(j) Stay rod iron
(k) Coupling set with plate, bush, nuts, bolts and washers
(l) Key stainless steel for coupling
Repair to pump shaft to its original shape by remetaling, turning, cutting and grinding and making bearing/ bush housing
Disconnecting to all electric connections from LT panel and motor for repair of motor starter of 50 HP/ 75 HP, star-delta starter, automatic unmanned type suitable for centrifugal/ submersible pumps, transportation to workshop and re-installation the same at site after necessary repair/ replacement of old defective/ damaged spare parts such as contactors, relays, of existing makes and specifications, complete all as specified and directed by Engineer-In-Charge. Note: (i) Cost of new spare parts will be measured and paid separately under respective items. (ii) Cost of tools and plants, minor spare parts such as copper wire, lubricants and transportation to workshop shall be deemed included in quoted rate.
Supply only following new spare parts required for replacement for repair of motor starter of 50 HP to 75 HP suitable for centrifugal pumps :- (a) Contactor, triple pole, capacities 70 Amps to 110 Amps.
(b) Globe indicator set (RYB)
(c) Overload relay
(d) Single phase protection relay.
(e) Copper lugs suitable for copper cable 25.0 Sqmm size.
(f) Toggle button having on/ off position.
Disconnecting electric connections from alternator and fuel connection from engine decoupling of engine and alternator for repair, strip opening and de-assembling of engine for repair including dismantling of radiator, radiator fan, water pump assembly, air cleaner, fuel filter by opening nuts bolts including wiring of stare assembly if required, of DG set capacity 100 KVA to 320 KVA and replacement of old defective spare parts with new spare parts as mentioned here-in-after, including any type of machine work required at site/ workshop to compete the repair including complete servicing the engine all as required at site, re-assembling the engine in existing position complete and testing on completion all as specified and as directed by Engineer-In-Charge. Make of Engine and Alternator: SM No: Note: (a) New spare parts for engine will be measured and paid separately as supply only under the respective items. (b) Cost of cleaning, welding, minor repair and special tools and plants required for dismantling engine will deemed to be included in quoted rates.
Supply only following new spare parts required for repair of DG Set capacity 100 KVA to 125 KVA :- (a) Fuel Filter.
(b) Oil Filter.
(c) Air Filter.
(d) Coupling rubber with assembly.
(e) Fan belt.
(f)Hose pipe set.
(g) Carbon bush of alternator.
(h) Carbon bush holder of alternator.
(j) Ball bearing of alternator.
(k) Slip rings assembly of alternator.
Replacement of old damaged/ unserviceable electronic rectifier/ Automatic Voltage Rectifier with new electronic rectifier/ Automatic Voltage Rectifier suitable for DG set capacity 100 KVA to 320 KVA, complete all as specified and as directed by Engineer-In-Charge.
Repair, calibration, checking and pressure testing of fuel injector pump including replacement of damaged/ defective parts such as delivery valve, plunger gasket kit, barrel and washers and testing whole assembly after necessary repair and fixing in engine, complete all as specified and as directed by Engineer-In-Charge.
De-assembling of radiator of DG set capacity 100 KVA to 320 KVA, for cleaning and repair, using ‘K’ oil and radiator cleaning solution hydro-chloric acid by pressure of pump/ caustic soda with wire brush and necessary welding/ brazing of water tubes/ fins, whichever is required for cleaning and repairing, complete all as specified and as directed by Engineer-In-Charge.
Supply only engine oil/ lubricant, 20 W 40 grade, suitable for diesel engine of DG set of any capacity and any make, complete all as specified and as directed by Engineer-In-Charge.
Supply only coolant fluid suitable for radiator of DG sets of any capacity and any make, complete all as specified and as directed by Engineer-In-Charge.
Replacement of old unserviceable/ damaged battery with new storage cell lead acid type 12 Volts, 150 AH including lead terminals and copper thimble for making necessary connections, complete all as specified and as directed by Engineer-In-Charge.
Supply only copper lead cable 1.50mtrs long, multi-stranded, with copper thimble for making necessary connections at both ends, suitable for 12/ 24 Volts battery including copper nuts, bolts and washers, complete all as specified and as directed by Engineer-In-Charge.
Replacement of old damaged/ unserviceable copper cable with new cable, flat, PVC insulated and PVC sheathed copper conductor, multi-stranded, 12.0 Sqmm, single, conforming to relevant IS specifications including making connection to both ends i.e. motor side and starter side with jointing materials, complete all as specified and directed by Engineer-In-Charge.
Replacement of old damaged/ unserviceable submersible cable with new submersible cable, flat, PVC insulated and PVC sheathed copper conductor, multi-stranded, 25.0 Sqmm, 3-core, conforming to IS: 694/1990 including making connection to both ends i.e. motor side and starter side with jointing materials, complete all as specified and directed.
Rewinding of burnt/ damaged motor of submersible pumps of capacities 5 HP, 20 HP, 45 HP and 55 HP of any discharge capacity with water proof, annealed solid copper conductor wire of existing specifications, insulating materials, ISI marked or as per IE specifications and cleaning, preparation of stator for rewinding, complete all as specified and directed by Engineer-In-Charge.
Rewinding of burnt/ damaged induction motor of centrifugal pumps of capacities 5 HP, 100 HP/ 125HP, of any discharge capacity with water proof, annealed solid copper conductor wire of existing specifications, insulating materials, ISI marked or as per IE specifications and cleaning, preparation of stator for rewinding, complete all as specified and directed by Engineer-In-Charge.
Lowering down, commissioning back to tube well of submersible pump sets with lowering pipe, flange or any type and any size of any depth with pump set of any capacities by manual or mechanical means including making necessary electric connections with LT panel or starter and testing on full load after repairs, complete all as specified and directed by Engineer-In-Charge. Note: (i) Cost of tools and plants for taking out, minor spare parts such as nuts, bolt, washers, lubricants shall be deemed included in quoted rate.
Replacement of old unserviceable/ damaged MCCB with new MCCB, four pole, 415 Volts, adjustable thermal and adjustable magnetic setting, 125 Amps with breaking capacity 25 KA, having indicating lamp, Ics=100% and Icu as per IEC 60947-2, complete all as specified and as directed by Engineer-In-Charge.
Disconnecting electric connections of servo voltage stabilizers, capacity 15 KVA to 30 KVA, draining out the transformer oil in clean barrels for re-use, cleaning of sludge from oil tank and transporting to workshop for repairs and return back to it's original position after repairs including loading and unloading by mechanical means, complete all as specified and as directed by Engineer-In-Charge. Note: Spares required for repair/ replacement of unserviceable parts shall be measured and paid separately under relevant items of BOQ.
Description all as serial item No- 145.00 here-in-before but for servo voltage stabilizer of capacity exceeding 30 KVA but not exceeding 60 KVA capacity.
Description all as serial item No- 145.00 here-in-before but for servo voltage stabilizer of capacity exceeding 60 KVA but not exceeding 100 KVA capacity.
Replacement of old unserviceable Printed Circuit Board (PCB) with new Printed Circuit Board (PCB) of voltage stabilizer as per existing make and type, capacity 15 KVA to 30 KVA, complete all as specified and as directed by Engineer-In-Charge.
Description all as serial item No- 148.00 here-in-before but for servo voltage stabilizer of capacity exceeding 30 KVA but not exceeding 60 KVA capacity.
Description all as serial item No- 148.00 here-in-before but forservo voltage stabilizer of capacity exceeding 60 KVA but not exceeding 100 KVA capacity.
Replacement of old unserviceable carbon bushes with new carbon bushes of voltage stabilizer as per existing make and type, capacity 15 KVA to 30 KVA, complete all as specified and as directed by Engineer-In-Charge.
Description all as serial item No- 151.00 here-in-before but for servo voltage stabilizer of capacity exceeding 30 KVA but not exceeding 60 KVA capacity.
Description all as serial item No- 151.00 here-in-before but for servo voltage stabilizer of capacity exceeding 60 KVA but not exceeding 100 KVA capacity.
Replacement of old unserviceable servo motor with new servo motor of voltage stabilizer as per existing make and type, capacity 15 KVA to 30 KVA, complete all as specified and as directed by Engineer-In-Charge.
Description all as serial item No- 154.00 here-in-before but for voltage stabilizer of capacity exceeding 30 KVA but not exceeding 60 KVA capacity.
Description all as serial item No- 154.00 here-in-before but for voltage stabilizer of capacity exceeding 60 KVA but not exceeding 100 KVA capacity.
Replacement of old unserviceable/ damaged Change over switch with new Change over switch, on load, rating 100 Amps, four poles, 415 Volts, AC, 50 Hz, with side handle, conforms to IS:13947 (Part-3); IEC:60947-2, complete all as specified and as directed by Engineer-In-Charge.
Supply and distribute Calcium Hypo Chloride 65%-70% Chlorine content calcium based granular disinfectant for water treatement to Pump House at rakhmuthi and outer station. Make Shree RayalaSeema Hi -Strength Hypo Ltd Or as approved by E-in-C's Branch or by Accepting Officer. Note :-The brand/ make of the chlorination of chemical must be stated in production and certified by govt laboratory confirming compliance of specification suitable for drinking water with a declearation from the laboratory that from the technical strengh stability health safety and operation point of view this product is used for drinking water applications for consumption by humans and the brand/make of calcium hypochlorite is suitable for drinking water chlorination and its sample has been tested by Govt Laboratory
Supply and distribute Bleaching Powder conforming to Grade I with minimum available chlorine 35-40% weight in 25Kg packing, packed in poly-ethylene bags ( not more than 2 months old packing).
Testing of chlorine jointly in presence of operator of 06 Nos tube well once in a day Morning / Evening before supply hrs to ensure free chlorination 2.0 PPM at source & including routine and periodical maintenance of chemical dozing pumps replacement of defective spare parts to keep them functional at serviceable condition and maintaining record duly signed by operator. Note:- 1. The cost of transportation daily to check tube well in Morning & Evening deemed to be includeed in quoted rates. 2. Spare parts required shall be measured and paid separately as supply only under respective items of BOQ. 3. The record of free chlorine check to be put up daily to JE E/M / AGE E/M for verification. 4. Contractor will be responsible for proper chlorination in all pump houses. In case chlorination is not found or found in appropriate at any location during inspection by concerned JE E/M or Engr-in-Charge, the recovery @ Rs 1000.00 will be deducted for per location per day from contractor's dues to the Govt.
Supply only O-tolodine chlorine solution in packing of 500 ml bottles for testing of chlorine contents in water , complete all as specified and directed by Engineer-in-Charge.
Supply only the chlorine test kit for the pump house to check the free chlorine level at source & user end at up to 2.0 PPM level complete all as specified and directed.
Cleaning of overhead water tank, capacity 50,000 Gallons, height/ staging 18.85mtrs, by scraping with mild steel wire brush and removing all the silt, dirt, algae, sludge etc from the surfaces of walls and floor including removal the same to a distance not less than 50mtrs, washing the cleaned surface with bleaching powder solution thoroughly and applying two coats of lime wash on internal surfaces of reservoir, also applying two coats of cement paint of external surfaces of tank with staging after preparation of surfaces, and writing the particulars such as capacity of tank, date/ due date of tank cleaning in bold letters, on table size not less than 60cmx40cm, painted with black and white synthetic enamel paint on external surface, including painting with one coat black synthetic enamel paint to external surfaces of flow pipes with valves any type as connected with overhead water tank and making flow signs with white synthetic enamel paint, complete all as specified and directed by Engineer-In-Charge.
Cleaning of UG Sump, 50000 Gln capacity by disconnecting all electric connections from LT panel, starter, removing pipe line from discharge side, taking out submersible/ centrifugal pump with motor along with column pipe by mechanical or manual method, scraping all mud, algae, silt, sludge and other dirts by mild steel wire brush floor including removal the same to a distance not less than 50mtrs and re-assembling/ lowering down submersible/ centrifugal pump with motor, column pipe and making all electric and water supply connection to the existing lines/ system, also applying two coats of cement paint of external surfaces of tank with staging after preparation of surfaces, including writing the particulars such as capacity of tank, date/ due date of tank cleaning in existing letter sizes, on table size not less than 60cmx40cm, painted with black and white synthetic enamel paint on external surface, complete all as specified and as directed by Engineer-In-Charge.
Repair to LT panel board 440 Volts at CTS Pump House outdoor type with suitable cleaning materials for cleaning bus bar, carbonized terminals of switches etc, replacement of old burnt thimbles of size 300 sqmm - 16 Nos, colour taping of bus bar complete including replacement of MCCB 630 Amps breaking capacity 50 KA -01 No complete all as specified and directed by Engr-in-Charge.
Taking out old centrifugal pump 100 HP capacity by dismantling of broken foundation, provision of new PCC foundation complete with suitable nuts & bolts for fixing of existing pump including replacement of rusted MS frame complete all as specified and directed by Engr-in-Charge
Disconnecting existing electric connection of Booster Pump 200 HP capacity, dismantling side cover of motor for repair/replacement of carbon bushes- 12 Nos, cleaning complete with CRC/Petrol, meggaring the motor before running on full load, replacement of burnt copper thimbles of 300 sqmm size complete including alignment of pump & motor, replacement of gland packing & rusted nuts & bolts all as specified and directed.
PVC insulated FRLS flexible cable with PVC insulated, sheathed, multi-stranded copper conductor 1100 volts grade, size 1.50 Sqmm, 3.0-core for connection, complete all as specified and as directed by Engineer-In-charge.
Disconnecting all electric connections and taking down of air conditioner of any capacity, split type, installed at the site or mounting at any height and transport to MES store yard/ workshop for servicing, cleaning/ removing the dust internally and externally, replacement of defective spare parts, as required including washing/ cleaning the outer surfaces, evaporator, condensor, air filters, ground chassis including making dry after washing, lubrication to rotatory parts, testing after repairs including making necessary connection to the power point (if required), complete all as specified and as directed by Engineer-In-Charge. Note: (i) New spare parts/ items required in replacement of old defective spare parts/ items shall be measured and paid separately under respective items. (ii) Cost of transportation from site to workshop for repair and workshop to site after repair, labour required for repairs/ replacement of spare parts being repair/ replaced, shall be deemed included in quoted rate.
Description all as serial item No- 170.00 here-in-before but for air conditioner of any capacity, window type.
Supply only following new spare parts required to replacement for repairs of air conditioner (capacity as mentioned) :- (a) Motor for condensor of air conditioner, capacity 1.50 ton, window type, complete all as specified and as directed by Engineer-In-Charge.
(b) Condensing coil for air conditioner of 1.50 Ton capacity, complete all as specified and as directed by Engineer-In-Charge.
(c) Thermostat switch for air conditioner, capacity 1.50/ 2.0 ton, window type, complete all as specified and as directed by Engineer-In-Charge.
(d) Starting relay for air conditioner, capacity 1.50 Ton, window type, complete all as specified and as directed by Engineer-In-Charge.
(e) Over load protection relay, air conditioner, capacity 1.50 Ton, window type, complete all as specified and as directed by Engineer-In-Charge.
(f) Wiring kit for air conditioner, window type, capacity 1.50 Ton and as per existing specifications, including internal wiring, complete all as specified and as directed by Engineer-In-Charge.
(g) Front grill for air conditioner of 1.50 Ton capacity as per existing specifications, complete all as specified and as directed by Engineer-In-Charge.
(h) Air filter for air conditioner mettalic type), capacity 1.50 ton, window type, complete all as specified and as directed by Engineer-In-Charge.
(j) Gas/ refrigerant filter for air conditioner mettalic type), capacity 1.50 ton, window type, complete all as specified and as directed by Engineer-In-Charge.
(k) Cooling coil for air conditioner of 1.50 Ton capacity, complete all as specified and as directed by Engineer-In-Charge.
(l) Condensor fan blade for air conditioner of 1.50 Ton capacity, complete all as specified and as directed by Engineer-In-Charge.
(m) Operating knob for air conditioner of 1.50 Ton capacity, complete all as specified and as directed by Engineer-In-Charge.
(n) Fan for blower motor of air conditioner of 1.50 Ton capacity, complete all as specified and as directed by Engineer-In-Charge.
(o) Hermetic sealed unit (compressor) suitable for window type, uncut, for air conditioner of 1.50 Ton capacity, complete all as specified and as directed by Engineer-In-Charge.
(p) Hermetic sealed unit (compressor) suitable for split type, uncut, for air conditioner of 1.50 Ton capacity, complete all as specified and as directed by Engineer-In-Charge.
(q) Hermetic sealed unit (compressor) suitable for split type, uncut, for air conditioner of 2.0 Ton capacity, complete all as specified and as directed by Engineer-In-Charge.
(r) Printed Circuit Board for air conditioner, split type, capacity 1.50 Ton and as per existing specifications, including internal wiring, complete all as specified and as directed by Engineer-In-Charge.
(s) Blower motor for air conditioner, capacity 2.0 ton, split type, complete all as specified and as directed by Engineer-In-Charge.
(t) Copper tubes, size ¼ inches with insulation rubber, suitable for air conditioner of any capacity, split type, and as per existing specifications, fixing in repairs at any levels including clamps and screws, complete all as specified and as directed by Engineer-In-Charge.
(u) Copper tubes, size ½ inches with insulation rubber, suitable for air conditioner of any capacity, split type, and as per existing specifications, fixing in repairs at any levels including clamps and screws, complete all as specified and as directed by Engineer-In-Charge.
(v) Copper tubes, size 3/8 inches with insulation rubber, suitable for air conditioner of any capacity, split type, and as per existing specifications, fixing in repairs at any levels including clamps and screws, complete all as specified and as directed by Engineer-In-Charge.
(w) Copper tubes, size 5/8 inches with insulation rubber, suitable for air conditioner of any capacity, split type, and as per existing specifications, fixing in repairs at any levels including clamps and screws, complete all as specified and as directed by Engineer-In-Charge.
Replacement of old/ damaged base tray with new base tray of mild steel 1.60mm thick, duly painted with powder coated paint, suitable for air conditioner, capacity 1.50 Ton, by removing and re-fixing compressor, condensor coil, copper tube, complete all as specified and as directed by Engineer-In-Charge.
Recharging/ replacement/ filling of refrigerant (R-134a), suitable for air conditioner of any capacity and any specifications including testing and repairing against any leakage by welding, soldering, complete all as specified and as directed by Engineer-In-Charge.
Disconnecting all electric connections and transporting water coolers of any type and of any capacity, to MES store yard/ workshop for repairing and servicing, by cleaning/ washing the water storage tank, compressor and outer body, tightening the hinges/ screws and replacement of defective spare parts including testing after repairs and making necessary connection to the power points, complete all as specified and as directed by Engineer-In-Charge. Note: (i) New spare parts/ items required in replacement of old defective spare parts/ items shall be measured and paid separately under respective items. (ii) Cost of transportation from site to workshop for repair and workshop to site after repair, repair/ replacement and minor spare parts required of water coolers, shall be deemed included in quoted rate.
Supply only following new spare parts required to replacement for repairs of water coolers (capacity as mentioned) :- (a) Hermetic sealed unit, for water cooler capacity 40/80 liters, complete all as specified and as directed by Engineer-In-Charge.
(b) Hermetic sealed unit, for water cooler capacity 60/120 liters, complete all as specified and as directed by Engineer-In-Charge.
(c) Hermetic sealed unit, for water cooler capacity 150/150 liters, complete all as specified and as directed by Engineer-In-Charge.
(d) Condensor fan motor of 1/35 HP for water cooler of any capacity, complete all as specified and as directed by Engineer-In-Charge.
(e) Automatic thermostat suitable for water cooler any descriptions and of any capacity, complete all as specified and as directed by Engineer-In-Charge.
(f) Condensor fan blade for water cooler, capacity 40/80, 60/120 and 150/150 liters, complete all as specified and as directed by Engineer-In-Charge.
(g) Condensor coil for water cooler, capacity 40/80, 60/120 and 150/150 liters, complete all as specified and as directed by Engineer-In-Charge.
(h) Strainer (Micro filter) for ¼ gas (refrigerant) for condensor coil for water cooler, capacity 40/80, 60/120 and 150/150 liters, complete all as specified and as directed by Engineer-In-Charge.
(j) Evaporator coil for water cooler, capacity 40/80, 60/120 and 150/150 liters, complete all as specified and as directed by Engineer-In-Charge.
Recharging/ replacement/ filling of refrigerant (R-134a), suitable for water cooler any descriptions, capacity 40/80 Litres including testing and repairing against any leakage by welding, soldering, complete all as specified and as directed.
Recharging/ replacement/ filling of refrigerant (R-134a), suitable for water cooler any descriptions, capacity 60/120 Litres including testing and repairing against any leakage by welding, soldering, complete all as specified and as directed.
Recharging/ replacement/ filling of refrigerant (R-134a), suitable for water cooler any descriptions, capacity 150/150 Litres including testing and repairing against any leakage by welding, soldering, complete all as specified and as directed.
Replacement of old unserviceable push button bib tap with new push button bib tap, long shank, cast copper alloy, chromium plated, fancy type, screwed down, screwed for iron pipe or for brass ferrule and fixed for 15mm bore pipe, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.
Spray painting of water cooler capacity 40/80 Litres with two coats of synthetic enamel paint of approved colour by spraying machine including filling cavities with filler, after cleaning all dusts and removing of dent from surfaces including writing of MES Nos. with synthetic enamel paint of black colour on lateral side of water cooler, complete all as specified and as directed by Engineer-In-Charge.
Spray painting of water cooler capacity 60/120 Litres with two coats of synthetic enamel paint of approved colour by spraying machine including filling cavities with filler, after cleaning all dusts and removing of dent from surfaces including writing of MES Nos. with synthetic enamel paint of black colour on lateral side of water cooler, complete all as specified and as directed by Engineer-In-Charge.
Spray painting of water cooler capacity 150/150 Litres with two coats of synthetic enamel paint of approved colour by spraying machine including filling cavities with filler, after cleaning all dusts and removing of dent from surfaces including writing of MES Nos. with synthetic enamel paint of black colour on lateral side of water cooler, complete all as specified and as directed by Engineer-In-Charge.
Disconnecting all electric connections and transporting refrigerator of any capacity and any type, to MES store yard/ workshop for repairing and servicing, by cleaning/ washing the internal surfaces and racks, compressor and outer body and lubrication of movable parts, tightening the hinges and replacement of defective spare parts including testing after repairs and making necessary connection to the power points, complete all as specified and as directed by Engineer-In-Charge. Note: (i) New spare parts/ items required in replacement of old defective spare parts/ items shall be measured and paid separately under respective items. (ii) Cost of transportation from site to workshop for repair and workshop to site after repair, repair/ replacement and spare parts such as lubricating oil/ grease of refrigerator required being repair/ replaced, shall be deemed included in quoted rate.
Supply only following new spare parts required to replacement for repairs of refrigerator (capacity as mentioned) :- (a) Thermostat with auto defrost button for refrigerator of any descriptions, capacity 165 to 340 litres, complete all as specified and as directed by Engineer-In-Charge.
(b) Hermetic sealed unit uncut, capacity 1/8 HP, suitable for refrigerator of 165 to 210 liters capacity, complete all as specified and as directed by Engineer-In-Charge.
(c) Hermetic sealed unit uncut, capacity 1/6 HP, suitable for refrigerator of 210 to 285 liters capacity, complete all as specified and as directed by Engineer-In-Charge.
(d) Hermetic sealed unit uncut, capacity 1/6 HP, suitable for refrigerator of 300 to 340 liters capacity, complete all as specified and as directed by Engineer-In-Charge.
(e) Hermetic sealed unit, capacity 1/6 HP, suitable for deep freezer of 300 to 405 liters capacity, complete all as specified and as directed by Engineer-In-Charge.
(f) De-frost timer TMDE706 SC cycle time 6H35M, 60 Hz/ 7H54M, 50 Hz, single phase, 220- 240 Volts, suitable for deep freezers, complete all as specified and as directed by Engineer-In-Charge.
(g) Bimotel component of 4/3 wire for freezer/ refrigerator, capacity 285 to 340 liters, complete all as specified and as directed by Engineer-In-Charge.
(h) Relay, PTC of any type, suitable for refrigerator of 300/310 liters capacity, complete all as specified and as directed by Engineer-In-Charge.
(j) Refrigerator door seal of rubber gasket including proper insulation, for refrigerator of 165 to 215 liters capacity, complete all as specified and as directed by Engineer-In-Charge.
(k) Refrigerator door seal of rubber gasket including proper insulation and magnetic system, for refrigerator of 280 to 340 liters capacity, complete all as specified and as directed by Engineer-In-Charge.
(l) Lamp suiatble for refrigerator, pin/ screw type, for refrigerator of any capacity, complete all as specified and as directed by Engineer-In-Charge.
(m) Evaporator coil for refrigerator, capacity 165 to 180 liters, complete all as specified and as directed by Engineer-In-Charge.
(n) Evaporator coil for refrigerator, capacity 210 to 340 liters, complete all as specified and as directed by Engineer-In-Charge.
(o) Drain/ Ice tray suitable for refrigerator, capacity 165 to 215 liters, complete all as specified and as directed by Engineer-In-Charge.
(p) Drain/ Ice tray suitable for refrigerator, capacity 280 to 340 liters, complete all as specified and as directed by Engineer-In-Charge.
(q) Wiring kit for refrigerator, capacity 280 to 340 liters and as per existing specifications, including internal wiring, complete all as specified and as directed by Engineer-In-Charge.
Replacement of old unserviceable/ damaged PVC staging/ plastic stand with new PVC staging stool/ plastic stand of different sizes, for refrigerator of 165 to 340 liters capacity, complete all as specified and as directed by Engineer-In-Charge.
Recharging/ replacement/ filling of refrigerant (R-134a), suitable for refrigerators/ deep freezers, any capacity including testing and repairing against any leakage by welding, soldering, complete all as specified and as directed.
Sheet metal enclosures with socket plug top and MCB suitable for single pole and neutral including a two pin and earth plug and socket complete with one single pole MCB, single pole, 40 Amps, 240 Volts, complete all as specified and as directed.
Disconnecting all electric connections from mains and transporting voltage stabilizer of any type and 1.0 to 5.0 capacity, to MES store yard/ workshop for repairing/ servicing, by cleaning the outer body and replacement of defective spare parts including testing after repairs and making necessary connection with power points, complete all as specified and as directed by Engineer-In-Charge. Note: (i) New spare parts/ items required to replaced shall be measured and paid separately under respective items. (ii) Cost of transportation from site to workshop for repair and workshop to site after repair, repair/ replacement and minor spare parts required being replaced of voltage stabilizer, shall be deemed included in quoted rate.
Supply only following new spare parts required to replacement for repairs of voltage stabilizer (capacity as mentioned) :- (a) Voltmeter, rating 0-300 Volts, analog type, round shap, 2.50 inches dia, complete all as specified and as directed by Engineer-In-Charge.
(b) Power relay, 24 Volts, 260 Ohms, 30 Amps (set of three) suitable for voltage stabilizer, complete all as specified and as directed by Engineer-In-Charge.
(c) Power relay, 18 Volts, 500 Ohms, 30 Amps (set of three) suitable for voltage stabilizer, complete all as specified and as directed by Engineer-In-Charge.
(c) Power relay, 18 Volts, 500 Ohms, 30 Amps (set of three) suitable for voltage stabilizer, complete all as specified and as directed by Engineer-In-Charge.
(d) Bakelite terminal strip, (bakelite connector), 4-way, suitable for voltage stabilizer capacity 1.0 KVA to 5.0 KVA, complete all as specified and as directed by Engineer-In-Charge.
(e) Printed Circuit Board with 15 Volts IC, with internal wiring, suitable for voltage stabilizer capacity 1.0 KVA to 2.0 KVA, complete all as specified and as directed by Engineer-In-Charge.
(f) Printed Circuit Board with 24 Volts IC, with internal wiring, suitable for voltage stabilizer capacity 3.0 KVA to 5.0 KVA, complete all as specified and as directed by Engineer-In-Charge.
(g) Trigger transformer (control step down transformer), 24 Volts, 260 Ohms, suitable for voltage stabilizer, complete all as specified and as directed by Engineer-In-Charge.
(h) Trigger transformer (control step down transformer), 18 Volts, 260 Ohms, suitable for voltage stabilizer, complete all as specified and as directed by Engineer-In-Charge.
Rewinding of main transformer of voltage stabilizer capacity 0.50 KVA, single phase, with super enameled copper winding wire of existing insulation, gauge and specifications, complete all as specified and as directed by Engineer-In-Charge Note: Rewinding of transformer shall have same number of turns of winding wire and with matching to manufacturer design.
Rewinding of main transformer of voltage stabilizer capacity 1.0 KVA, single phase, with super enameled copper winding wire of existing insulation, gauge and specifications, complete all as specified and as directed by Engineer-In-Charge Note: Rewinding of transformer shall have same number of turns of winding wire and with matching to manufacturer design.
Rewinding of main transformer of voltage stabilizer capacity 2.0 KVA, single phase, with super enameled copper winding wire of existing insulation, gauge and specifications, complete all as specified and as directed by Engineer-In-Charge Note: Rewinding of transformer shall have same number of turns of winding wire and with matching to manufacturer design.
Rewinding of main transformer of voltage stabilizer capacity 4.0 KVA, single phase, with super enameled copper winding wire of existing insulation, gauge and specifications, complete all as specified and as directed by Engineer-In-Charge Note: Rewinding of transformer shall have same number of turns of winding wire and with matching to manufacturer design.
Rewinding of main transformer of voltage stabilizer capacity 5.0 KVA, single phase, with super enameled copper winding wire of existing insulation, gauge and specifications, complete all as specified and as directed by Engineer-In-Charge Note: Rewinding of transformer shall have same number of turns of winding wire and with matching to manufacturer design.
Taking down existing desert cooler of any capacity, mounting in any locations and transporting to MES store yard/ workshop for carrying out necessary repairs, servicing, oiling/ lubricating, cleaning the water tank, motor, blades and testing, return the same after carrying out necessary repair work installation at site or other location, including repairs of defective cable connections and making connections of indicating lamps, PVC water pipes and elbow etc, complete all as specified and as directed by Engineer-In-Charge. Note: (i) Spare parts shall be measured and paid separately under respective items of BOQ but cost of transportation to workshop and back to site, repairs shall be deemed included in quoted rate. (ii) Cost of minor spare parts such as PVC elbows, flexible pipes, lubricants, rubber pads and wire mesh shall be deemed included in quoted rate.
Supply only following new spare parts required to replacement for repairs of desert cooler (capacity as mentioned) :- (a) Fan motor, AC operated, single phase, three wires, capacity 1/7 HP, 240 volts suitable for desert cooler and making necessary electric connection and fixing mild steel arms, complete all as specified and as directed by Engineer-In-Charge.
(c) Submersible water pump (tullu pump), AC operated, single phase, capacity 1/20 HP, 240 volts suitable for desert cooler and making necessary connection to power supply including flexible PVC tubing of required size, complete all as specified and as directed by Engineer-In-Charge.
(d) Wooden wool/ grass pads for three sides including binding with GI wire tightly, for desert cooler of any specifications, complete all as specified and as directed by Engineer-In-Charge.
(e) Fan blade (Set of three), mild steel, existing size, with fixing screws with motor, suitable for dessert cooler, complete all as specified and as directed by Engineer-In-Charge.
(f) Mild steel wire mesh, made with 2.0mm dia gi wire powder coated paint, suitable for fixing wood wool pads, for desert cooler of any descriptions, complete all as specified and as directed by Engineer-In-Charge.
(g) Mild steel side, back grill including louvers fins, powder coated paint, suitable for fixing wood wool pads, for desert cooler of any descriptions, complete all as specified and as directed by Engineer-In-Charge.
Replacement of old unserviceable ball valves with new ball valve, PVC, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed for 15mm bore pipe, complete all as specified and as directed by Engineer-In-Charge.
Replacement of old unserviceable/ damaged PVC connections with new PVC connections 15mm size, length 600mm with PTMT nuts at both ends, for inlet water supply, complete all as specified and directed by Engineer-In-Charge.
Replacement of old unserviceable/ damaged capacitor with new capacitor, capacity 4.0mfd, suitable for electric equipments, complete all as specified and as directed by Engineer-In-Charge.
Replacement of old unserviceable/ damaged capacitor with new capacitor, capacity 10.0mfd, suitable for electric equipments, complete all as specified and as directed by Engineer-In-Charge.
Replacement of old unserviceable/ damaged capacitor with new capacitor, 36mfd, suitable for electric equipments, complete all as specified and as directed by Engineer-In-Charge.
Replacement of old unserviceable/ damaged capacitor with new capacitor, 45mfd, suitable for electric equipments, complete all as specified and as directed by Engineer-In-Charge.
Replacement of old unserviceable/ damaged starting capacitor with new starting capacitor, 40/ 60mfd, suitable for electric equipments, complete all as specified and as directed by Engineer-In-Charge.
Replacement of old unserviceable/ damaged starting capacitor with new starting capacitor, 100/ 120mfd, suitable for electric equipments, complete all as specified and as directed by Engineer-In-Charge.
Preparation of old painted surfaces of desert cooler metallic body by scrapping old paint with emery/ sand paper and spray painting with one coat of red oxide on internal surfaces and one coat of synthetic enamel paint on external surfaces in colour as approved and writing MES No. on body of dessert cooler, complete all as specified and as directed by Engineer-In-Charge.
Sub main wiring for circuits/ submain wiring alongwith earth wire with two run of 10.0 Sqmm of fire resistance, PVC insulated copper conductor, single core cable, multi-stranded, FRLS, ISI marked, 1100 Volts grade and one run of 6.0 Sqmm, FRLS, PVC insulated copper conductor, single core cable, multi stranded, ISI marked, 1100 Volts grade as earth wire connected to earth terminal, drawn in and including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 25mm dia including all accessories, concealed by chasing/ cutting grooves in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications incl taking down old sub main, complete all as specified and as directed by Engineer-In-Charge. Note: Two runs of 10.0 sqmm copper wires and one run of 6.0 Sqmm copper wires including PVC conduit shall be measured as one unit.
Sub main wiring for circuits/ submain wiring alongwith earth wire with two run of 4.0 Sqmm of fire resistance, PVC insulated copper conductor, single core cable, multi-stranded, FRLS, ISI marked, 1100 Volts grade and one run of 4.0 Sqmm, FRLS, PVC insulated copper conductor, single core cable, multi stranded, ISI marked, 1100 Volts grade as earth wire connected to earth terminal, drawn in and including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 25mm dia including all accessories, concealed by chasing/ cutting grooves in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications taking down old sub main, complete all as specified and as directed by Engineer-In-Charge. Note: Three runs of 4.0 Sqmm copper wires including PVC conduit shall be measured as one unit.
Replacement of old unserviceable/ damaged MCCB with new MCCB, three pole, 415 Volts, adjustable thermal and fixed magnetic setting, 100 Amps with breaking capacity 16 KA, having indicating lamp, Ics=100% Icu and as per IEC 60947-2, complete all as specified and as directed by Engineer-In-Charge. Make: Schneider cat part No- LV426157 or equivalent in in L&T/ Legrand/ ABB/ Merlin Gerin/ Siemens.
Sheet metal enclosures for Single Pole and Neutral distribution boxes with double door glazed for incorporating MCBs, IP-43, 8-way with 200 amps rated busbar, 240 volts, as per IS-8623, complete all as specified and as directed by Engineer-In-Charge.
Replacement of old unserviceable MCB with new MCB, Single pole and Neutral, 40 Amps, 240 Volts, having breaking capacity of 10 KA, ‘C’ series, conforming to IS/IEC: 60898, complete all as specified and as directed by Engineer-In-charge.
MCB, single pole, 6 to 32 Amps, 240 Volts, 50 Hz, including necessary incoming and out going electric connection with suitable size of copper lugs, complete all as specified and as directed by Engineer-In-Charge.
Supplying and fixing in replacement, 1100 Volts grade, heavy duty, multi-stranded cable, PVC insulated aluminium conductor, multi-stranded, cross sectional area 10.0 Sqmm, 2-core, served with inner sheathing of PVC tape and overall PVC sheathed in service connections complete all as specified and as directed by Engineer-In-Charge.
PVC insulated FRLS flexible cable with PVC insulated, sheathed, multi-stranded copper conductor 1100 volts grade, size 4.0 Sqmm, 3-core for connection, complete all as specified and as directed by Engineer-In-charge.
PVC insulated FRLS flexible cable with PVC insulated, sheathed, multi-stranded copper conductor 1100 volts grade, size 2.50 Sqmm, 3-core for connection, complete all as specified and as directed by Engineer-In-charge.
Sheet metal enclosures with socket plug top and MCB suitable for single pole and neutral including a two pin and earth plug and socket complete with one single pole MCB, single pole, 20 Amps, 240 Volts, complete all as specified and as directed by Engineer-In-Charge.
Replacement of old unserviceable/ damaged plug top with new plug top, 15 Amps, 3-pin, 240 volts, complete all as specified and as directed by Engineer-In-Charge.
Replacement of old unserviceable/ damaged plug top with new plug top, 5 Amps, 3-pin, 240 volts, complete all as specified and as directed by Engineer-In-Charge.
SPECIAL NOTE FOR DG SETS AND VOLTAGE STABLIZER'S REPAIRS/PUMPS: The contractor will submit a scanned copy of Memorandum of under standing from OEMs ( or authorized dealers) for the respective E/M installations. The details of OEMs are as under:- (a) DG Set (i) Kirlosker Green/Cummins (ii) Crompton Greaves (iii) Sudhir (iv) Mahindra (b) Servo Voltage Stablizer (i) Vinitek (ii) Electric field (c) Submersible and Centrifugal Pumps (i) Kirloskar (ii) KSB (iii) Jyoti
Amount of Schedule of credit of for Rs 3,18,899.00 shall be deducted from quoted amount.
M/S CJ CONSTRUCTIONS
asian traders
M/S BIJRAL ENTERPRISES
M/S ANMOL TRADING CO
M/S SHARMA ENTERPRISES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .