Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.6 LAccepted-AOC 3701 3701 NEAR SAINI HOSPITAL UKLANA ROAD BHUNA 125111 | FATEHABAD | HARYANA | 125111 | L1 | Accepted-AOC Tender allotted to L1 agency |
| Sl No | Description | Qty | Unit | The Sinthla Coop LC Society Ltd L1 |
|---|---|---|---|---|
| 1.00Sweeping | ||||
| 1.01 | 1 One No. of Job work for two years proper maintenance of 4 Nos. of 250 HP non-clog submersible pumps, 2 Nos. of Gen sets of 500 KVA including fuel, Panels, Transformer, VCB, PLC Scada, Electrical items and other machinery installed at pumping station. Regular cleaning of collecting tank and screeing chambers, Regular desilting of 6 Kilometers RCC Pipe line (including repair of RCC pipe if any leakage or defect is found) and Gully Traps including providing 2 Nos. of pump operator-cum-electrician, 2 nos. Chowkidar, Machinery 01 no. excavator, 01 no. JCB, 2 nos. Tractor Trolly, 4 nos. Tractor mounted pumps) 5 nos. Sewerman as per the satisfaction of Engineer-in-charge | 2 | Per Year | 9,90,000 ₹19,80,000 Lowest |
| 1.02 | Providing lowering cutting jointing and testing Providing, lowering, laying, aligning, fixing in position and jointing at all level/ depths ISi marked HDPE pipe of PE-100 grade and PN-6 for sewer. application as per IS 14333-1996 (amended up to date) in trenches in complete induding cost of HOPE Specials, labour, sectional hydro testing (including the cost and conveyance of water to site for testing) and commissioning as per Technical Specifications and as per direction of Engineer. As per HSR 21.97.15 | 48 | meter | 44,138 ₹21,18,624 Lowest |
| 1.03 | Extra for excavating trenches for pipes, cables, etc, in all kinds of metre soil for depth exceeding 3 m in depth, but not exceeding 4.5 m. (Rate is over corresponding basic item for depth up to 1.5 metre.) As per HSR 4.18 | 3,600 | cum | 92 ₹3,31,200 Lowest |
| 1.04 | Providing & fixing cast iron double flanged swing check type reflux (non return) valves PN-1.6 marked with IS:5312 including nuts & bolts marked with IS:1363, rubber sheet marked with IS:638 etc., carriage loading, unloading, stacking, handling, re-handling etc. Complete in all respect to the satisfaction of Engineer-in-charge 300 mm i/d each As per HSR 20.11.6 | 3 | Nos. | 19,222 ₹57,666 Lowest |
| 1.05 | M.S. flanges of 300 mm dia | 3 | Nos. | 3,000 ₹9,000 Lowest |
| 1.06 | Providing and fixing rubber sheet 3mm thick of best quality for jointing flanged pipes, specials etc. including making of holes etc. complete in all respects to the satisfaction of Engineer-in-Charge for pipe size 300mm i/d. As per HSR 20.53.6 | 20 | each | 50 ₹1,000 Lowest |
| 1.07 | Providing and laying Double Flanged (Screwed/Welded) Centrifugally (Spun) Ductile Iron Pipes of Class K-9 conforming to IS: 8329: 300 mm dia Ductile Iron Double Flanged as per HSR 22.161.5 | 2.7 | meter | 3,984 ₹10,756.8 Lowest |
| 1.08 | Providing and laying in position cement concrete 1 of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 1:12:3 (1 Cement: 1% coarse sand (zone-III) As per HSR 6.1.1 | 10 | cum | 4,356 ₹43,560 Lowest |
| 1.09 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer-in-charge. Nominal concrete 1:2:4 or leaner mix (i/c equivalent cum design mix) As per HSR 5.23.2 | 8 | cum | 1,274 ₹10,192 Lowest |
Tender Value
Refer Docs
EMD Value
₹96,000
Closing Date
16 Feb 2026, 5:00 pmClosed
Executive Engineer
MC Sirsa
Operation and Maintenance of strom water drainage system in MC Sirsa for 2 years.
2026_HRY_500056_1
MCSIRSA
Open Tender
Civil Works
Works
SIRSA
Operation and Maintenance of strom water drainage system in MC Sirsa for 2 years.
2 documents required · 2 mandatory
₹2,500
₹96,000
Yes
24 Mar 2026
2 Feb 2026
17 Feb 2026
2 Feb 2026
16 Feb 2026
2 Feb 2026
Sweeping
1 One No. of Job work for two years proper maintenance of 4 Nos. of 250 HP non-clog submersible pumps, 2 Nos. of Gen sets of 500 KVA including fuel, Panels, Transformer, VCB, PLC Scada, Electrical items and other machinery installed at pumping station. Regular cleaning of collecting tank and screeing chambers, Regular desilting of 6 Kilometers RCC Pipe line (including repair of RCC pipe if any leakage or defect is found) and Gully Traps including providing 2 Nos. of pump operator-cum-electrician, 2 nos. Chowkidar, Machinery 01 no. excavator, 01 no. JCB, 2 nos. Tractor Trolly, 4 nos. Tractor mounted pumps) 5 nos. Sewerman as per the satisfaction of Engineer-in-charge
Providing lowering cutting jointing and testing Providing, lowering, laying, aligning, fixing in position and jointing at all level/ depths ISi marked HDPE pipe of PE-100 grade and PN-6 for sewer. application as per IS 14333-1996 (amended up to date) in trenches in complete induding cost of HOPE Specials, labour, sectional hydro testing (including the cost and conveyance of water to site for testing) and commissioning as per Technical Specifications and as per direction of Engineer. As per HSR 21.97.15
Extra for excavating trenches for pipes, cables, etc, in all kinds of metre soil for depth exceeding 3 m in depth, but not exceeding 4.5 m. (Rate is over corresponding basic item for depth up to 1.5 metre.) As per HSR 4.18
Providing & fixing cast iron double flanged swing check type reflux (non return) valves PN-1.6 marked with IS:5312 including nuts & bolts marked with IS:1363, rubber sheet marked with IS:638 etc., carriage loading, unloading, stacking, handling, re-handling etc. Complete in all respect to the satisfaction of Engineer-in-charge 300 mm i/d each As per HSR 20.11.6
M.S. flanges of 300 mm dia
Providing and fixing rubber sheet 3mm thick of best quality for jointing flanged pipes, specials etc. including making of holes etc. complete in all respects to the satisfaction of Engineer-in-Charge for pipe size 300mm i/d. As per HSR 20.53.6
Providing and laying Double Flanged (Screwed/Welded) Centrifugally (Spun) Ductile Iron Pipes of Class K-9 conforming to IS: 8329: 300 mm dia Ductile Iron Double Flanged as per HSR 22.161.5
Providing and laying in position cement concrete 1 of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 1:12:3 (1 Cement: 1% coarse sand (zone-III) As per HSR 6.1.1
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer-in-charge. Nominal concrete 1:2:4 or leaner mix (i/c equivalent cum design mix) As per HSR 5.23.2
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.33 MB
BOQ_578659.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .