Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance NO 36 2ND FLOOR DEVI NAGAR SECOND STREET KOLATHUR CHENNAI TAMIL NADU 600099 | CHENNAI | TAMIL NADU | 600099 | Admitted-Finance |
| 4 | Not Admitted-Fee/PreQual/Technical SHOP AT E 523 RAMPHAL CHOWK DWARKA SEC 7 T F PALAM EXTN SECTOR 7 DWARKA NEW DELHI SOUTH WEST DELHI DELHI 110045 | SOUTH WEST DELHI | DELHI | 110045 | Not Admitted-Fee/PreQual/Technical Others-Exemption for EMD and TC not admissible as the MSME/NSIC certificate not meant for tendered item ie STP/WTP maintenance. |
| 5 | Not Admitted-Fee/PreQual/Technical 41 5 FOURTH TRUST CROSS STREET MANDAVELIPAKKAM MANDAVELIPAKKAM CHENNAI TAMIL NADU 600028 INDIA | CHENNAI | TAMIL NADU | 600028 | Not Admitted-Fee/PreQual/Technical Others-Eligibility requirement does not fulfilled as per TC 1.2.1.1 |
Tender Value
₹13.8 L
EMD Value
₹27,580
Closing Date
11 Jan 2023, 5:00 pmClosed
Executive Engineer(c), ABM DIVISION
Executive Engineer Civil, BSNL Civil Division ABM, GF BSNL Admin Bldg , 16 Greams Road, Chennai 6
Operation and Maintenance Services for the Water and Sewage Treatment Plant in the Administrative Building compound at Greams Road, Chennai 06 for the year 2022-23
2022_BSNL_139437_1
13/BSNL/CD/ABM/CH/2022/23
Open Tender
Civil Works - Others
Item Rate
365 days
Chennai
Please refer Tender documents.
3 documents required · 3 mandatory
₹590
Yes
AO Cash BSNL TN Circle Chennai6
₹27,580
Yes
21 Jan 2023
24 Dec 2022
12 Jan 2023
24 Dec 2022
11 Jan 2023
24 Dec 2022
Amount
Supply of following chemicals and materials for use in Sewage treatment plant and water treatment plant in required quantity as specified the Engineer in Charge.
Sodium Hypo chloride of Brand Hpo Clean or Equivalent
Antiscalant (Food grade)
Alum of brand Generic or equivalent
Chlorine
Sodium chloride/Salt
Bio culture (powder) of brand Bio D Bacteria or equivalent
Servicing of Motors with pumps including the cost of lubrication oil, replacement or repair of wornout/ burnt parts, Disconnection and reconnection of supply and delivery lines, removing and refixing of motor pumps for servicing, transportion of all leads and lifts to servicing point and return etc., complete all as directed by the Engineer-in-charge.
Raw sewage pump in sewage treatment plant (1hp)
Air blower pump in sewage treatment plant (7hp)
Sludge transfer pump in sewage treatment plant (1hp)
Filter feed pump in sewage treatment plant (3hp)
RO plant feed pump (1hp)
High pressure pump in water treatment plant (3hp)
Dosing pump in water treatment plant
Domestic water pump in Domestic water treatment plant (2hp)
Providing comprehensive services for Operation of the Water treatment plant of capacity 6500 LPH, RO plant of capacity of 2500 LPH and the sewage treatment plant of capacity 95 KLD round the clock ensuring effective flow of effluents including running of all the connected pumps, valves etc., located within the premises, cleaning of inlet chambers, grit chamber, coarse screen chamber, etc of STP, operation of softener plant, RO plant, open wash and back wash of filter, filling dosage consumables, softener acid wash and descaling membrane of WTP, as and when required and maintaining relevant records, keeping the premises clean etc, of Sewage treatment plant and water treatment plant including all labour charges, transportation of tools, monthly visit by technician, submission of inspection report including testing of STP water & RO water etc., (For colour, odour, TDS andsalinity, etc. with multiparameter pocket water quality tester) complete all as directed by the Engineer in charge and safeguarding the equipment and as directed by the Engineer in charge. (If services are not provided in any shift, or any day the deduction will be made proportionately while making payment and deduction will be made for non submission of monthly inspection report by the qualified Technician) Consumables will be supplied departmentally and the dosage and frequency of consumables shall be as directed by Engineer - in - charge. (If inspection report is not submitted, Rs 2000/- will be deducted for each occasion)
Testing of RO water sample in Govt. Approved testing laboratory as directed by the Engineer-in-charge.
Testing of Sewage treated water sample in laboratory approved by Tamilnadu Pollution control board as directed by the Engineer-in-charge.
Replacing of UV lamp and driver of approved make to the UV sterilizer equipement in Sewerage treatment plant
UV lamp for GL-30
Driver for UV stabilizer equipement GL-30
H2O ENGINEERING AND TECHNOLOGIES
Global Enviro System
stage.html
html • 0.03 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .