Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.2 LAccepted-AOC | ₹25.2 L Quoted ₹28.4 L | L1 | Accepted-AOC L1 |
| 2 | L2₹30.6 L+₹2.2 L (7.89%)Rejected-Finance H NO 1 8 3 22 4 SURYA NAGAR TADI COMPLEX CHIKKADAPALLY HYDERABAD 500020 | HYDERABAD | HYDERABAD | TELANGANA | 500020 | ₹30.6 L+₹2.2 L (7.89%) | L2 | Rejected-Finance Not being lowest |
| Sl No | Description | Qty | Unit | prem enterprises L1 | UNITED AIR COOLING & PROJECTS L2 |
|---|---|---|---|---|---|
| 1.00 | M&L for battery bank 96V, 800 Ah with maintanance free dry battery cell of rating 2V, 800Ah suitablre for solar PV generation inverter of capacity 10/15 KW ,battery DC 96 V, AC input voltage 360-460 V AC, AC output 400 V AC including copper cable connections between batteries complete all as spcified and directrd by Engineer-in-Charge. | 3 | Each bank | 8,50,000 ₹25,50,000 Lowest | 8,71,459 ₹26,14,377 |
| 2.00 | M&L in repair of P V MODULES Solar Photovoltaic module of poly crystaline Silicon solar PV Module having peak power rating 315Wp as per site requirement for existing solar power plant plant.
max power - 315 Wp
Current at P max - 8.05 A
Voltage at P max - 37.28 V
I Sc - 8.74 A,V oc - 45.10 V | 15 | Each | 11,000 ₹1,65,000 Lowest | 15,600 ₹2,34,000 |
| 3.00 | Supply ,fixing and testing 1C x 4 sq. mm MC4 Connectors pair (1 for + ve and 1 for - ve) complete all as spcified and directrd by Engineer-in-Charge. | 100 | Each | 50 ₹5,000 Lowest | 95 ₹9,500 |
| 4.00 | Supply ,laying ,testing and commissinoning of LT, D C Cables (color code) Photovoltaic Cables as per IS 7098 part 1 guide Lines for modules to Junction Boxes connections 800V 1Cx4 Sq.mm Annealed Tinned multi stranded Copper cables with required accessories like conduits,glands,cable tie ,ferrules as per requirement. Electrical Characterstics :- 1.Rated Insulation Voltage: 800 V AC
2. Insulation Rated DC Voltage: 1.1 kV
3 .Working Voltage: DC 800 V | 200 | RM | 130 ₹26,000 Lowest | 135 ₹27,000 |
| 5.00 | Caliberation/Servicing/Overhauling & testing of 10 KW inverter 3 phase solar roof top power plant.Item rate includes checking of electrical connections, continuity and serviceability of equipments, replacement of defective parts as per existing make and make the device operational and hand over to the MES after one year i;e completion of warranty period. Item rate includes replacement of the defective spare parts with new spare parts of existing make and make the inverter serviceable complete all as spcified and directrd by Engineer-in-Charge. | 3 | Each Job | 29,900 ₹89,700 Lowest | 58,224 ₹1,74,672 |
Tender Value
₹28.2 L
EMD Value
₹56,320
Closing Date
20 Feb 2026, 6:00 pmClosed
GE Army Jaisalmer
GE Army Jaisalmer - 345001
SPECIAL REPAIR OF SOLAR ROOF TOP SOLAR PLANT INSTALLED IN VARIOUS UNIT AT JAISALMER MIL STN
2026_MES_750631_1
8558/25-26/E8
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
Jaisalmer
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE Army Jaisalmer
₹56,320
Yes
11 Aug 2026
30 Jan 2026
23 Feb 2026
30 Jan 2026
20 Feb 2026
13 Feb 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | M&L for battery bank 96V, 800 Ah with maintanance free dry battery cell of rating 2V, 800Ah suitablre for solar PV generation inverter of capacity 10/15 KW ,battery DC 96 V, AC input voltage 360-460 V AC, AC output 400 V AC including copper cable connections between batteries complete all as spcified and directrd by Engineer-in-Charge. | 3 | Each bank | 1.25 | ₹3.75 |
| 2 | M&L in repair of P V MODULES Solar Photovoltaic module of poly crystaline Silicon solar PV Module having peak power rating 315Wp as per site requirement for existing solar power plant plant.
max power - 315 Wp
Current at P max - 8.05 A
Voltage at P max - 37.28 V
I Sc - 8.74 A,V oc - 45.10 V | 15 | Each | - | - |
| 3 | Supply ,fixing and testing 1C x 4 sq. mm MC4 Connectors pair (1 for + ve and 1 for - ve) complete all as spcified and directrd by Engineer-in-Charge. | 100 | Each | 100 | ₹10,000 |
| 4 | Supply ,laying ,testing and commissinoning of LT, D C Cables (color code) Photovoltaic Cables as per IS 7098 part 1 guide Lines for modules to Junction Boxes connections 800V 1Cx4 Sq.mm Annealed Tinned multi stranded Copper cables with required accessories like conduits,glands,cable tie ,ferrules as per requirement. Electrical Characterstics :- 1.Rated Insulation Voltage: 800 V AC
2. Insulation Rated DC Voltage: 1.1 kV
3 .Working Voltage: DC 800 V | 200 | RM | 53 | ₹10,600 |
| 5 | Caliberation/Servicing/Overhauling & testing of 10 KW inverter 3 phase solar roof top power plant.Item rate includes checking of electrical connections, continuity and serviceability of equipments, replacement of defective parts as per existing make and make the device operational and hand over to the MES after one year i;e completion of warranty period. Item rate includes replacement of the defective spare parts with new spare parts of existing make and make the inverter serviceable complete all as spcified and directrd by Engineer-in-Charge. | 3 | Each Job | 10 | ₹30 |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.17 MB
BOQ_840699.xls
BOQ • 3.89 MB
TenderDocuments8558.pdf
Tender Documents • 1.39 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .