| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.3 LAccepted-AOC RZ 18 260 WEST SAGARPUR NEAR MCD SCHOOL NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹38.5 L+₹1.9 L (5.05%)Rejected-Finance A 3 257 JANAKPURI NEW DELHI 110058 | WEST DELHI | DELHI | 110058 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹38.7 L+₹2.0 L (5.46%)Rejected-Finance WZ 576 577 NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹39.1 L+₹2.5 L (6.70%)Rejected-Finance H NO 90 VILLAGE REWLA KHANPUR PO NAJAFGARH NEW DELHI 110043 | NEW DELHI | WEST DELHI | DELHI | 110043 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹41.8 L+₹5.2 L (14.1%)Rejected-Finance 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | L5 | Rejected-Finance Other than lowest |
Tender Value
₹49.5 L
EMD Value
₹99,080
Closing Date
3 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE UTILITY PLANT AND MACHINERY DELHI CANTT-10
GE UTILITY PLANT AND MACHINERY KIRBY PLACE DELHI CANTT-10
REPAIR MAINTENANCE TO WATER TREATEMENT PLANTS AND OTHER MISC WORKS OF VARIOUS UNITS UNDER GE (U) PM DELHI CANTT-10
2022_MES_549827_1
GE(U)/PM/D-39/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
DELHI CANTT-10
MES contractor enlisted under class D category b(i) having deposited standing security of Rs 100000 with department. Contractor not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category.
6 documents required · 6 mandatory
₹500
GE UTILITY PLANT AND MACHINERY DELHI CANTT-10
₹99,080
Yes
10 Nov 2022
3 Sept 2022
5 Oct 2022
3 Sept 2022
3 Oct 2022
18 Sept 2022
Amount
SECTION-I Disconnecting from mains and Taking down for servicing of Auqa guards and RO water purifier of Capacity 8 to 20 LPH including detecting the leakage of water and refilling, cleaning of unserviceable items including checking the servicibility of electrical/electronic circuits relays, wiring kit, etc., and keeping the RO system in satisfactory working condition all as specified and as directed . Note :- 1. Replacement of defective spares will be measured & paid separately under relevant items as 'Supply only'. 2. Labour charges for taking out old spares and fixing of new spares shall deemed to be included in unit rate quoted.
Supply only Carbon Filter for 8 to 20 LPH RO water purifier complete all as specified and directed.. (Make - Kent/PRW/Aquasure/Aquapure/Aquafresh/Amritanjal)
Supply only Sediment Filter for 8 to 20 LPH RO water purifier complete all as specified and directed.. (Make - Kent/PRW/Aquasure/Aquapure/Aquafresh/Amritanjal)
Supply only Post Carbon Filter for 8 to 20 LPH RO water purifier complete all as specified and directed.. (Make - Kent/PRW/Aquasure/Aquapure/Aquafresh/Amritanjal)
Supply only Membrane Filter 75GPD complete all as specified and as directed. (Make - Kent/PRW/Aquasure/Aquapure/Aquafresh/Amritanjal)
Supply only Spun Filter for 8 to 20 LPH RO water purifier complete all as specified and as directed.. (Make - Kent/PR/Aquasure/Aqua pure)
Supply only Pump for RO water purifier 100PSI/600RP 75GPD complete all as specified and as directed.. (Make - Kent/PRW/Aquasure/Aquapure/Aquafresh/Amritanjal)
Supply only Solenoid Valve 24V DC for 8 to 20 LPH RO water purifier complete all as specified and as directed.. (Make - Kent/PRW/Aquasure/Aquapure/Aquafresh/Amritanjal)
Supply only Water Level Sensor with Float for 8 to 20 LPH RO water purifier complete all as specified and as directed.. (Make - Kent/PRW/Aquasure/Aquapure/Aquafresh/Amritanjal)
Supply only UV Lamp 11W for 8 to 20 LPH RO water purifier complete all as specified and as directed.. (Make -Kent/PRW/Aquasure/Aqua pure)
Supply only UV Lamp Assembly 11W for 8 to 20 LPH RO water purifier complete all as specified and as directed.. (Make - Kent/PRW/Aquasure/Aquapure/Aquafresh/Amritanjal)
Supply only in repairs UV Adapter for 8 to 20 LPH RO water purifier complete all as specified and as directed. (Make - Kent/PRW/Aquasure/Aquapure/Aquafresh/Amritanjal) Note for item No 2.00 to 12.00:- Materials of item no 2.00 to 12.00 to be incorporated in item No 1.00 here-in-before
Disconnecting from mains and Taking down for servicing of Auqa guards and RO water purifier of Capacity 25 to 30 LPH including detecting the leakage of water and refilling, cleaning of unserviceable items including checking the servicibility of electrical/electronic circuits relays, wiring kit, etc., and keeping the RO system in satisfactory working condition all as specified and as directed. Note :- 1. Replacement of defective spares will be measured & paid separately under relevant items as 'Supply only'. 2. Labour charges for taking out old spares and fixing of new spares shall deemed to be included in unit rate quoted.
Supply only Membrane Filter 100 GPD complete all as specified and as directed. (Make - Kent/PRW/Aquasure/Aquapure/Aquafresh/Amritanjal)
Supply only Pump for RO water purifier 150PSI/600RP 100GPD complete all as specified and as directed. (Make - Kent/PRW/Aquasure/Aquapure/Aquafresh/Amritanjal)
Supply only Calcium Treatment Unit (CTU) Filter for 25 to 30 LPH RO water purifier complete all as specified and as directed. (Make - Kent/PRW/Aquasure/Aquapure/Aquafresh/Amritanjal)
Supply only JCO Filter complete all as specified and as directed. (Make - Kent/PR/Aquasure/Aqua pure)
Supply only Carbon Filter for 25 to 30 LPH RO water purifier complete all as specified and as directed. (Make - Kent/PRW/Aquasure/Aquapure/Aquafresh/Amritanjal)
Supply only Spun Filter for 25 to 30 LPH RO water purifier complete all as specified and as directed. (Make - Kent/PRW/Aquasure/Aquapure/Aquafresh/Amritanjal)
Supply only F/R 300/ 450 for 25 to 30 LPH RO water purifier complete all as specified and as directed. (Make - Kent/PRW/Aquasure/Aquapure/Aquafresh/Amritanjal)
Supply only Solenoid Valve 36V DC for 25 to 30 LPH RO water purifier complete all as specified and as directed. (Make - Kent/PRW/Aquasure/Aquapure/Aquafresh/Amritanjal)
Supply only Sediment Pre Filter for 25 to 30 LPH RO water purifier complete all as specified and as directed. (Make - Kent/PRW/Aquasure/Aquapure/Aquafresh/Amritanjal) Note for item No 14.00 to 22.00:- Materials of item no 14.00 to 22.00 to be incorporated in item No 13.00 here-in-before
Disconnecting from mains and Taking down for servicing of Auqa guards and RO water purifier of Capacity 40 to 50 LPH including detecting the leakage of water and refilling, cleaning of unserviceable items including checking the servicibility of electrical/electronic circuits relays, wiring kit, etc., and keeping the RO system in satisfactory working condition all as specified and as directed. Note :- 1. Replacement of defective spares will be measured & paid separately under relevant items as 'Supply only'. 2. Labour charges for taking out old spares and fixing of new spares shall deemed to be included in unit rate quoted.
Supply only Membrane Filter 100 GPD complete all as specified and as directed. (Make - Kent/PRW/Aquasure/Aquapure/Aquafresh/Amritanjal)
Supply only Pump for RO water purifier 150PSI/600RP 150GPD complete all as specified and as directed. (Make - Kent/PRW/Aquasure/Aquapure/Aquafresh/Amritanjal)
Supply only Calcium Treatment Unit (CTU) Filter for 40 to 50 LPH RO water purifier complete all as specified and as directed. (Make - Kent/PRW/Aquasure/Aquapure/Aquafresh/Amritanjal)
Supply only Spun Filter for 40 to 50 LPH RO water purifier complete all as specified and as directed. (Make - Kent/PRW/Aquasure/Aquapure/Aquafresh/Amritanjal)
Supply only Inline Carbon Filter 8 to 10 inch for 40 to 50 LPH RO water purifier complete all as specified and as directed. (Make - Kent/PRW/Aquasure/Aquapure/Aquafresh/Amritanjal)
Supply only Post Carbon Filter complete all as specified and as directed. (Make - Kent/PRW/Aquasure/Aquapure/Aquafresh/Amritanjal)
Supply only FRT 800 ML for 40 to 50 LPH RO water purifier complete all as specified and as directed. (Make - Kent/PRW/Aquasure/Aquapure/Aquafresh/Amritanjal)
Supply only Solenoid Valve 36V DC for 40 to 50 LPH RO water purifier complete all as specified and as directed. (Make - Kent/PRW/Aquasure/Aquapure/Aquafresh/Amritanjal)
Supply only Sediment Pre Filter 20" for 40 to 50 LPH RO water purifier complete all as specified and as directed. (Make - Kent/PRW/Aquasure/Aquapure/Aquafresh/Amritanjal)
Supply only Water Level Sensor with Float for 40 to 50 LPH RO water purifier complete all as specified and as directed. (Make - Kent/PRW/Aquasure/Aquapure/Aquafresh/Amritanjal) Note for item No 24.00 to 33.00:- Materials of item no 24.00 to 33.00 to be incorporated in item No 23.00 here-in-before.
Disconnecting from mains and Taking down for servicing of Auqa guards and RO water purifier of Capacity 80 to 100 LPH including detecting the leakage of water and refilling, cleaning of unserviceable items including checking the servicibility of electrical/electronic circuits relays, wiring kit, etc., and keeping the RO system in satisfactory working condition all as specified and as directed. Note :- 1. Replacement of defective spares will be measured & paid separately under relevant items as 'Supply only'. 2. Labour charges for taking out old spares and fixing of new spares shall deemed to be included in unit rate quoted.
Supply only Membrane Filter 300 GPD complete all as specified and as directed. (Make - Kent/PRW/Aquasure/Aquapure/Aquafresh/Amritanjal)
Supply only Pump for RO water purifier 100PSI/600RP 300 GPD complete all as specified and as directed. (Make - Kent/PRW/Aquasure/Aquapure/Aquafresh/Amritanjal)
Supply only Calcium Treatment Unit (CTU) Filter for 80 to 100 LPH RO water purifier complete all as specified and as directed. (Make - Kent/PRW/Aquasure/Aquapure/Aquafresh/Amritanjal)
Supply only Spun Filter for 80 to 100 LPH RO water purifier complete all as specified and as directed. (Make - Kent/PRW/Aquasure/Aquapure/Aquafresh/Amritanjal)
Supply only Carbon Filter 8" for 80 to 100 LPH RO water purifier complete all as specified and as directed. (Make - Kent/PRW/Aquasure/Aquapure/Aquafresh/Amritanjal)
Supply only Solenoid Valve 48V DC for 80 to 100 LPH RO water purifier complete all as specified and as directed (Make - Kent/PRW/Aquasure/Aquapure/Aquafresh/Amritanjal)
Supply only Water Level Sensor with Float for 80 to 100 LPH RO water purifier complete all as specified and as directed (Make - Kent/PRW/Aquasure/Aquapure/Aquafresh/Amritanjal)
Supply only Membrane housing set for 80 to 100 LPH RO water purifier complete all as specified and as directed. (Make - Kent/PRW/Aquasure/Aquapure/Aquafresh/Amritanjal)
Supply only Sediment Pre Filter for 80 to 100 LPH RO water purifier complete all as specified and as directed. (Make - Kent/PRW/Aquasure/Aquapure/Aquafresh/Amritanjal)
Supply only SMPS 2.5 Amp 24Volts DC complete all as specified and as directed. (Make - Kent/PRW/Aquasure/Aquapure/Aquafresh/Amritanjal)
Supply only in repairs SMPS 3 Amp 36Volts DC complete all as specified and as directed. (Make - Kent/PRW/Aquasure/Aquapure/Aquafresh/Amritanjal)
Supply only Adaper 2.5 Amps 24Volts DC complete all as specified and as directed. (Make - Kent/PRW/Aquasure/Aquapure/Aquafresh/Amritanjal)
Supply only Adaper 3 Amps 36Volts DC complete all as specified and as directed. (Make - Kent/PRW/Aquasure/Aquapure/Aquafresh/Amritanjal) Note for item No 35.00 to 47.00:- Materials of item no 35.00 to 47.00 to be incorporated in item No 34.00 here-in-before.
Taking down old unserviceable old RO water purfier & Supply, Installation, testing and commissioning stainless steel body RO Water Purifier system of capacity 100 Ltrs/Hr, max duty cycle 500 L/Day, comprising of Sediment, Activated Carbon, UF, Post Carbon filters & thin film composite RO membrane, UF membrane 0.1-0.01 Micron, auto flushing system , inlet water pressure/temp (Min) 0.3 Kg/cm2 /10ºC and Inlet water pressure/Temp (Max) 4 Kg/cm2 /40ºC, min/max operating pH 6.5- 8.0, total power consumption 240 Watts, Input power supply – single phase 100-250 V AC, 50-60 Hz complete all as specified and directed . (Make :- KENT, Model No- KENT ELITE II PLUS or of equivalent model in AQUA GUARD/ LIVPURE)
Taking down old unserviceable old RO water purfier & Supply, Installation, testing and commissioning RO Water Purifier system of capacity 50 Ltrs/Hr, max duty cycle 250 L/Day, With an ABS food grade construction for corrosion free life span and in-built comprising of Sediment, Activated Carbon, UF, Post Carbon filters & thin film composite RO membrane, UF membrane 0.1-0.01 Micron, auto flushing system, inlet water pressure/temp (Min) 0.3 Kg/cm2 /10ºC and Inlet water pressure/Temp (Max) 4 Kg/cm2 /40ºC, min/max operating pH 6.5- 8.0, total power consumption 240 Watts, Input power supply – single phase 100-250 V AC, 50-60 Hz complete all as specified and directed . (Make :- KENT, Model No- KENT ELITE PLUS or of equivalent model in AQUA GUARD/ LIVPURE/HAVELLS)
Taking down old unserviceable old RO water purfier & Supply, Installation, testing and commissioning in repairs RO Water Purifier system of capacity 25 Ltrs/Hr, max duty cycle 100 L/Day, built with ABS Food Grade Plastic, comprising of multiple purification process of RO+UV+UF+TDS with an in-tank UV disinfection, total power consumption 60 Watts, Input power supply – single phase 100-250 V AC, 50-60 Hz complete all as specified and directed (Make :- KENT, Model No-KENT Crystal Plus or of equivalent model in AQUA GUARD/LIVPURE/HAVELLS)
SECTION- II Isolate/de-energize the supply to the LT Panel Board of capacity ranging from 100 Amps to 400 Amps and voltage 415 Volts/230 Volts, opening the doors/covers of the cubicle enclosure for carrying out the servicing/maintenance/repairs of the Panel Board, switch gear,MCCB, metering etc and re-fixing in the same/New in place after repairs including testing and commissioning of the panel board comprising of the following:- a) Cleaning the inside switch gear chambers for removing dust, carbon and rusted surfaces including cleaning with blower . b) Check the condition of the DMC/SMC support insulators including cleaning applying Dr beck red for better IR values and replacement of insulators if required. c) Tightening up of all bus bar connections, cable connections, replace bolt, nuts wherever required. Note : Spares will be measured and paid under relevant items of schedule..
Supply only in repair of 3 phase digital multi function meter with suitable accessories and fixing arrangements complete all specified and as directed. (Make : L&T/ABB/Legrand/C&S)
Supply only in repair of Voltmeter of range 0 to 500 Volts as per existing model/ capacity complete all specified and as directed. (Make : L&T/Schneider/Siemens/AE/C&S)
Supply only in repair of Ammeter of range 0 to 500 Volts as per existing model/ capacity complete all specified and as directed. (Make : L&T/Schneider/Siemens/AE/C&S)
Supply only in repair of Indicator lamp neon/ LED type, RBY as per existing model/ capacity complete all specified and as directed .
Supply only CT coil ratio 200/5 as per existing model/ capacity complete all specified and as directed. (Make :L&T/Schneider/Siemens/AE/C&S)
Supply only in repairs of aluminium busbar (40x5mm)350 Amps capacity with colour code sleeve complete all as specified and as directed.
Supply only in repair of 1.50 sqmm size FRLS, PVC insulated, unsheathed 1100 volts grade single core multi-stranded copper conductor cable in proper colour coding drawn complete all as specified and directed.
Supply & Fixing in repair and replacement of mild steel hinges suitable for LT panel board shutters including welding, riveting complete all as specified and as directed.
Material and labour for preparation of surface by scrapping existing painted inside and out side surfaces of LT Panel board /Feeder pillar of size not more than 1.5m x 0.75m x 1.2m and applying one coat of synthetic enamel paint (1st grade quality) and one coat of heat resistant paint of approved quality and colour complete all as specified and directed. (Make of paint and primer:- ASIAN/ BERGER/ JHONSON & NICHOLSON/ SHALIMAR.)
Taking out the old unserviceable feeder pillar box and Supply install, testing and commissioning LT Distribution Panel (CPRI approved) Cubicle type,IP-64, indoor type confirming to IS 8623 Part I 1993 factory fabricated made out of 2 mm thick CRCA sheet & suitable size to accommodate all accessories / fittings, compartmentalized in construction to accommodate the incoming MCCB and TPN bus bars and outgoing feeders. The TPN busbars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator of size not less than 50x50 mm conical type at an interval of not more than 500 mm through out the length of the TPN bus bar. The incoming as well as outgoing MCCBs shall have extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC/Epoxy insulators having provision for termination of incoming and outgoing cables. All extension links/interconnection shall have colour coded sleeves. The cubicle shall have a bottom channel of size 75 x 40 mm, grouted in PCC 1:3:6 upto 40 CM height and as directed by Eng-in-charge. A detacheable gland plate of thickness not less than 3 mm thick should be used at the bottom for entry of armoured cable of adequate size compression glands. The panel shall be painted with powder coated finish with RAL 7032 SIEMENS GRAY STRUCTURE after seven tank phosphating treatment, front & back opening type, and fixing 2 Nos.danger notice plate with letter, figures and conventional skull bones in signal red colour and fixed front & back door to LT panel with voltage and danger indicated in Hindi and English, with double door shutter and shall have louvers and airvent gasket for natural flow of air, Neoprene adhesive type gasket shall be used to make panel vermin proof and comprising of following :- (Make: Legrand/ L&T/ Schneider/ ABB/ Havells/ Indoasian/ Shalabh)
(a) As incomer :- MCCB 125 Amp, FP, Thermal magnetic release adjustable, with a breaking capacity of 25kA with Ics=Icu 100%,along with suitable spreader links (Make : Legrand / L&T / ABB / Schneider / Seimens.) (b) Busbar TPN, Aluminum, 200 Amps - 01 Set (c) Digital Type multi function meter to measure V, A,F,PF with suitable CTs - 01 Set (Make : L&T/ABB/Legrand/C&S) (d) LED type phase indicator lamp (RYB) = 01 Set (e) As Outgoing MCCB 63 Amp, FP, Thermal magnetic release, adjustable with a breaking capacity of 16kA with Ics=Icu100%,alongwithsuitable spreader links. (Make : Legrand / L&T / ABB / Schneider / Seimens.) (f) MCB TPN 20 Amps capacity 10 KA three phase 03 Nos. (Make : Legrand / L&T / ABB / Schneider / Seimens.) (g) Dol Starter 5 Hp, 415V with over load relay and single phasing preventor = 02 Nos
Supplying and laying in repair synthetic Rubber insulated mats 2.5 mm thick for voltage upto 11 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all specified and as directed.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr depth and getting out in Soft / loose soil icomplete all specified and as directed.
Returning, filling in including spreading, levelling ,watering and well ramming in layers not exceeding 25 cm thick in soft/ loose soil complete all specified and as directed.
Removing excavated soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed.
Supply and laying of sub Class 'B' old size bricks designation 75, laid across the trenches as cable protection completed all specified and as directed.
Material and labour for sand cushioning to the full width of trenches for protection of cables including spreading watering and consolidation complete all as specified and as directed. (Note:- Only punned down volume of sand to be measured).
M&L in repair of Galvanised iron pipe light grade with all fitting laid in trenches / floor/ road crossing for protection of UG cables of the following sizes :- (Make : JINDAL/TATA/OSWAL/PRAKASH)
32 mm bore
50 mm bore
Taking out unserviceable/faulty/cable/service connection cable of any of any grade/type/class of any size laying only underground cable any size and capacity including cable connecting lugs, glands,jointing materials etc., laid in trenches, floors, roof, ducts and fixing using clamps, saddle for pole,making hole in wall as per requirement at site complete all as directed by Eng-in-charge. Note:- (i) Earth work and pipes shall be measured and paid seperately under relevent items.
Supply, laying, fixing, passing through pipe or laid in trench and testing underground xlpe insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade, cross section as area 35 Sqmm, 3.5 core compete all as specified and as directed. (Make:Polycab/Gloster/Havells/Plaza/Finolex/Grandlay)
Supply, laying, fixing, passing through pipe or laid in trench and testing underground xlpe insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross section as area 50 Sqmm, 3.5 core complete all as specified and as directed. (Make:Polycab/Gloster/Havells/Plaza/Finolex/Grandlay)
Supply, laying, fixing, passing through pipe or laid in trench and testing underground xlpe insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross section as area 70 Sqmm, 3.5 core complete all as specified and as directed. (Make:Polycab/Gloster/Havells/Plaza/Finolex/Grandlay)
Supply, laying fixing, passing through pipe or laid in trench and testing underground xlpe insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross section as area 95 Sqmm, 3.5 core complete all as specified and as directed. (Make:Polycab/Gloster/Havells/Plaza/Finolex/Grandlay)
S&F in repair of MCCB 4 Pole, 415 V, 63 Amps with breaking capacity 15 KA, Adjustable type complete all as specified and as directed. (Make : Legrand / L&T / ABB / Schneider / Seimens.)
S&F MCCB 4 Pole, 415 V, 100 Amps with breaking capacity 25 KA, Adjustable type complete all as specified and as directed. (Make : Legrand / L&T / ABB / Schneider / Seimens.)
S&F in repair of MCCB 4 Pole, 415 V, 125 Amps with breaking capacity 25 KA, Adjustable type complete all as specified and as directed. (Make : Legrand / L&T / ABB / Schneider / Seimens.)
S&F in repair of MCCB 4 Pole, 415 V, 250 Amps with breaking capacity 25 KA, Adjustable type complete all as specified and as directed. (Make : Legrand / L&T / ABB / Schneider / Seimens.)
S&F in repair of MCCB 4 Pole, 415 V, 400 Amps with breaking capacity 25 KA, Adjustable type complete all as specified and as directed. (Make : Legrand / L&T / ABB / Schneider / Seimens.)
Supply and fixing in repair of Reflector adhesive tape 25 mm with suitable for fixing in street light pole, colour of paint as decided complete all specified and as directed.
Taking out the old unserviceable feeder pillar box and Supply install, testing and commissioning LT Distribution Panel (CPRI approved) Cubicle type,IP-64,outdoor type confirming to IS 8623 Part I 1993 factory fabricated made out of 3.2 mm thick CRCA sheet & suitable size to accommodate all accessories / fittings, compartmentalized in construction to accommodate the incoming MCCB and TPN bus bars and outgoing feeders. The TPN busbars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator of size not less than 50x50 mm conical type at an interval of not more than 500 mm through out the length of the TPN bus bar. The incoming as well as outgoing MCCBs shall have extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC/Epoxy insulators having provision for termination of incoming and outgoing cables. All extension links/interconnection shall colour coded sleeves. The cubicle shall have a bottom channel of size 75 x 40 mm, grouted in PCC 1:3:6 upto 40 CM height and as directed by Eng-in-charge. A detacheable gland plate of thickness not less than 3 mm thick should be used at the bottom for entry of armoured cable of adequate size compression glands,The panel shall be painted with powder coated finish with RAL 7032 SIEMENS GRAY STRUCTURE after seven tank phosphating treatment, front & back opening type, and fixing 2 Nos.danger notice plate with letter, figures and conventional skull bones in signal red colour and fixed front & back door to LT panel with voltage and danger indicated in Hindi and English, with double door shutter and shall have louvers and airvent gasket for natural flow of air, Neoprene adhesive type gasket shall be used to make panel vermin proof and comprising of following :- (Make: Legrand/ L&T/ Schneider/ ABB/ Havells/ Indoasian/ Shalabh)
(a) Incoming MCCB FP 200 Amp 415 Volts 25 KA - 01 No (Make : Legrand / L&T / ABB / Schneider / Seimens.) b) Busbar Aluminum TPN 400 Amps - 01 Set (c) Digital Type multi function meter to measure V, A,F,PF with suitable CTs - 01 Set (Make : L&T/ABB/Legrand/C&S) (d) LED type phase indicator lamp (RYB) = 01 Set (a) Outgoing MCCB TP 160 Amp 25 KA - 02 No (Make : Legrand / L&T / ABB / Schneider / Seimens.) (b) MCCB TP 100 Amps 16 KA - 02 Nos (Make : Legrand / L&T / ABB / Schneider / Seimens.) e) MCCB DP 63 Amps, 10 KA - 02 Nos (Make : Legrand / L&T / ABB / Schneider / Seimens.) (c) One no Spare compartment suitable for fixing of MCCB upto 160 Amps
S & F in replacement of Street Lights/Security light box with astronomical type timer 230 Volt AC-01 Nos, contractor TP 415 volt 25 Amps -01 Nos, MCB SPN 20A - 03 Nos, On indicator -01 Nos, Auto mannual switch - 01 Nos, and control MCB SP 3 Amps -01 No, fixed in CPRI approved sheet metal enclosure 2mm thick of size 40 x 40 x 250 cm, outdoor type, duly painted with power coated finish with RAL 7032 SIMEns gray structure after tank phosphating treatment and fixing arrangement by means of 25 mm x 33 MS flat clamps, nuts bolts and washers complete all as specified and directed. (Make: Schneider/ ABB/ Havells/ Indoasian/ Shalabh)
Supply and fixing in replacement of new generation energy saving 150W LED Flood light power coasted PDC aluminum body with toughened glass visior lumen efficency >105Lm/w. Surge protection up to 10 KV PF>.95 temp 5700K to 6500K, IP 66 complete including taking out old U/S flood light fitting of any type/size. (Make : Havells/ CG/ Bajaj/ Syska)
Taking out the old unserviceable feeder pillar box and Supply install, testing and commissioning LT Distribution Panel (CPRI approved) Cubicle type,IP-64,outdoor type confirming to IS 8623 Part I 1993 factory fabricated made out of 3.2 mm thick CRCA sheet & suitable size to accommodate all accessories / fittings, compartmentalized in construction to accommodate the incoming MCCB and TPN bus bars and outgoing feeders. The TPN busbars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator of size not less than 50x50 mm conical type at an interval of not more than 500 mm through out the length of the TPN bus bar. The incoming as well as outgoing MCCBs shall have extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC/Epoxy insulators having provision for termination of incoming and outgoing cables. All extension links/interconnection shall have colour coded sleeves. The cubicle shall have a bottom channel of size 75 x 40 mm, grouted in PCC 1:3:6 upto 40 CM height and as directed by Eng-in-charge. A detacheable gland plate of thickness not less than 3 mm thick should be used at the bottom for entry of armoured cable of adequate size compression glands,The panel shall be painting with powder coated finish with RAL 7032 SIEMENS GRAY STRUCTURE after seven tank phosphating treatment, front & back opening type, and fixing 2 Nos.danger notice plate with letter, figures and conventional skull bones in signal red colour and fixed front & back door to LT panel with voltage and danger indicated in Hindi and English, with double door shutter and shall have louvers and airvent gasket for natural flow of air, Neoprene adhesive type gasket shall be used to make panel vermin proof and comprising of following (Make: Legrand/ L&T/ Schneider/ ABB/ Havells/ Indoasian/ Shalabh)
(a) Incoming MCCB 125 Amp, FP, Thermal magnetic release, adjustable with a breaking capacity of 25kA with Ics=Icu 100%,along with suitable spreader 01 Nos links (Make : Legrand / L&T / ABB / Schneider / Seimens.) (b) Busbar TPN, Aluminum, 200 Amps - 01 Set (c) Digital Type multi function meter to measure V, A,F,PF with suitable CTs - 01 Set (Make : L&T/ABB/Legrand/C&S) (d) LED type phase indicator lamp (RYB) = 01 Set (e) Outgoing 63 Amp,, FP, Thermal magnetic release, adjustable MCCB with a breaking capacity of 25kA with Ics=Icu100%,alongwith suitable spreader links 06 Nos. (Make : Legrand / L&T / ABB / Schneider / Seimens.)
M&L for earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick, burried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised earth lead by means of bolts, nuts, check nuts and washer of galvanised iron strip 32 x 6mm as earth lead as shown in electrical plate No. 3 of SSR Part I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal od surplus soil, earth pit in PCC 1:3:6 type C-1 using 20mm graded stone aggregate pit, funnel, 20mm bore GI tubing medium grade for watering pipe, 40mm bore medium grade GI pipe for protection of GI earth strip and pre-cast earth pit cover 50mm thick made of RCC (1:1.5:3) tyep A1 duly reinforced with 8mm dia TMT bar @ 100 mm c/c both ways, one lifting handle made out of 10mm dia TMT bar 250mm long embedded in cover slab and cover, wire, copper lugs etc mesh, charcoal and common salt in alternate layer of 15 cm thick including taking down old unserviceable one complete all as specified and directed by Engr-in-Charge. (Make of GI Pipe:-JINDAL/ TATA/ BST/ PRAKASH TUBES/ OSWAL) Note:- (i) Each protection pipe and earthing lead upto and including 7.5 meter lenght is deemed to be included in the qouted rate of this item. (ii) On testing after completion if desired earth resistance is not obtained, the earthing will be redone at no extra cost.
M & L in replacement of earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing etc using 32x6mm galvanised iron strip complete all as specified & as directed.
M & L for demolition of concrete of any description and in any position not otherwise specifically provided for complete all specified and as directed.
M & L for 100mm thick PCC 1:4:8 type D2 using 40mm graded aggregate as in sub base complete all specified and as directed.
M & L for 100mm thick PCC 1:2:4 type B1 using 20mm graded aggregate as in hardstanding laid in alternate panels, approx size 2500mm x 5000mm including necessary form work for deviding into panels complete all as specified.
Forming Contraction (Dummy) joints 30 mm deep x 10mm wide, filled with Grade 'A' sealing compound complete all specified and as directed
Forming 12mm thick Expansion joints for 100mm thick concrete slab, filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade `A' complete all specified and as directed
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .