| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.4 LAdmitted-Finance 6 KRIPANATH DUTTA ROAD KOLKATA 700 002 | KOLKATA | KOLKATA | WEST BENGAL | 700002 | ₹23.4 L | L1 | Admitted-Finance |
| 2 | L2₹23.4 L+₹8,342.60 (0.36%)Admitted-Finance 344 1 SB GORAI ROAD HILL VIEW PARK NORTH ASANSOL | ASANSOL | WEST BENGAL | ₹23.4 L+₹8,342.60 (0.36%) | L2 | Admitted-Finance |
| 3 | L3₹23.5 L+₹16,863.97 (0.72%)Admitted-Finance PATRA MARKET KRISHANAGAR NADIA | KRISHANAGAR | NADIA | ₹23.5 L+₹16,863.97 (0.72%) | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | B T PROJECTS PRIVATE LIMITED L1 | EASTERN INDIA SALES AND SERVICE L2 | Tarun Kumar Bhattacharya L3 |
|---|---|---|---|---|---|---|
| 1.00Pipe line repairing portion:- | ||||||
| 1.01 | EPDM gasket for 300 mm dia dismantling joint. | 2 | Sets | 1,400 ₹2,800 Lowest | 1,450 ₹2,900 | 1,500 ₹3,000 |
| 1.02 | 300 mm dia,P.N.-1.06, eccentric design Electrically gear operated, double flanged Cast Iron Fabricated butterfly valves generally conforming to IS: 13095, having body, disc and end cover in graded Cast Iron to IS:210 Gr FG260, Nitrile rubber face ring secured on disc by a SS AISI 304 retaining ring with stainless steel screws, the rubber ring seating on a corresponding SS AISI 304 seat in body, stub shaft of SS AISI 410 riding in teflon bearings. Flanges drilled to IS 1538 Table 4 & 6. Valves suitable for a working pressure of 16 kg/cm² (seat test) & body tested to 24 kg/cm². Valves are complete with 1.5 Mtr SS AISI 410 extension spindle, Coupling and CI headstock. Valves are operated by suitable Rotork Syncropak/AUMA Epak electrical operation.(Make:-IVI/Jupiter/Other approved make) | 1 | Set | 2,08,000 ₹2,08,000 Lowest | 2,09,000 ₹2,09,000 | 2,09,500 ₹2,09,500 |
| 1.03 | Atfirst the removal of the damaged EPDM gaskets from the dismantling joints of Centrifugal Pumps No. 5 and No. 7. It also includes the dismantling and replacement of the existing actuator-operated butterfly valve with a new actuator-operated butterfly valve, above supplied.EPDM gaskets will be installed at all required flange joints during reassembly. The work includes dismantling, removal of damaged components, installation of the new valve and gaskets, alignment, tightening of all fasteners, testing for proper operation of the actuator, and leak testing to ensure satisfactory and trouble-free performance after commissioning. | 1 | Item | 21,000 ₹21,000 Lowest | 21,250 ₹21,250 | 21,400 ₹21,400 |
| 1.04Centrifugal Pump-Motor installation portion:- | ||||||
| 1.05 | Horizontal Split casing Centrifugal Pumping Machinery with Channel Base Frame(ND355L), Pin-bush/Flange Couplings, Coupling Guards, Companion Flanges, foundation bolt etc.
M.O.C. for Pump:-
a) Volute Casing-C.I. IS:210, FG260
b) Impeller - CF8M(ASTM S743 Gr CF8M)
c) Shaft - SS ASTM A 276 CL 410
d) Shaft Sleeves-SS ASTM A 276 CL 410
e) Neck Ring- CF8M(ASTM S743 Gr CF8M)
f) Discharge-467 M³/Hour, Head-93.56 Mtr.
(H-Q-P Curve of Pumps has to be submitted during the delivery)
(Make:-Wilo/Mather & Platt /Other approved make)(Supplied pump's base should be capable of installing 225 KW/300 HP induction motor, base frame No-ND355L)
The pump shall Capable of operating independently and in parallel with other existing pump) | 1 | Set | 12,41,000 ₹12,41,000 Lowest | 12,42,000 ₹12,42,000 | 12,42,500 ₹12,42,500 |
| 1.06 | Eccentric reducer 400 mm X 200 mm, thickness 6 mm, as per IS:2062. | 1 | No | 8,000 ₹8,000 Lowest | 8,150 ₹8,150 | 8,200 ₹8,200 |
| 1.07 | Concentric enlarger 150 mm X 300 mm, thickness 6 mm, as per IS:2062. | 1 | No | 5,500 ₹5,500 Lowest | 5,600 ₹5,600 | 5,700 ₹5,700 |
| 1.08 | 400 mm dia slip on flange, as per IS:1538, 15 mm thick. | 4 | Nos | 3,300 ₹13,200 Lowest | 3,350 ₹13,400 | 3,500 ₹14,000 |
| 1.09 | 300 mm dia slip on flange, as per IS:1538, 15 mm thick. | 1 | No | 2,400 ₹2,400 Lowest | 2,450 ₹2,450 | 2,500 ₹2,500 |
Tender Value
Refer Docs
EMD Value
₹48,000
Closing Date
21 Aug 2026, 4:00 pmClosed
Executive Engineer,AMD P.H.E dte
Office of the Executive Engineer,Asansol Mechanical Division,Public Health Engineering Directorate,PASCHIM BARDHAMAN,713305
Repairing of dismantling joint, replacement of actuator operated butterfly valve for pump no-5(Delivery line) and supply delivery and installation of Centrifugal Pump set in position-06 with existing motor for Chora and Chinchuriah Zone at Searsole.
2026_PHED_1036418_1
WBPHED/EE/AMD/ NIeT-22 of 2026-2027
Open Tender
MISC ELECTRICAL WORKS
Item Wise
90 days
Searsole
Please refer Tender documents.
4 documents required · 4 mandatory
₹48,000
14 Sept 2026
5 Aug 2026
24 Aug 2026
5 Aug 2026
21 Aug 2026
5 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Pipe line repairing portion:- | |||||
| 1.01 | EPDM gasket for 300 mm dia dismantling joint. | 2 | Sets | - | - |
| 1.02 | 300 mm dia,P.N.-1.06, eccentric design Electrically gear operated, double flanged Cast Iron Fabricated butterfly valves generally conforming to IS: 13095, having body, disc and end cover in graded Cast Iron to IS:210 Gr FG260, Nitrile rubber face ring secured on disc by a SS AISI 304 retaining ring with stainless steel screws, the rubber ring seating on a corresponding SS AISI 304 seat in body, stub shaft of SS AISI 410 riding in teflon bearings. Flanges drilled to IS 1538 Table 4 & 6. Valves suitable for a working pressure of 16 kg/cm² (seat test) & body tested to 24 kg/cm². Valves are complete with 1.5 Mtr SS AISI 410 extension spindle, Coupling and CI headstock. Valves are operated by suitable Rotork Syncropak/AUMA Epak electrical operation.(Make:-IVI/Jupiter/Other approved make) | 1 | Set | - | - |
| 1.03 | Atfirst the removal of the damaged EPDM gaskets from the dismantling joints of Centrifugal Pumps No. 5 and No. 7. It also includes the dismantling and replacement of the existing actuator-operated butterfly valve with a new actuator-operated butterfly valve, above supplied.EPDM gaskets will be installed at all required flange joints during reassembly. The work includes dismantling, removal of damaged components, installation of the new valve and gaskets, alignment, tightening of all fasteners, testing for proper operation of the actuator, and leak testing to ensure satisfactory and trouble-free performance after commissioning. | 1 | Item | - | - |
| 1.04 | Centrifugal Pump-Motor installation portion:- | - | - | - | - |
| 1.05 | Horizontal Split casing Centrifugal Pumping Machinery with Channel Base Frame(ND355L), Pin-bush/Flange Couplings, Coupling Guards, Companion Flanges, foundation bolt etc.
M.O.C. for Pump:-
a) Volute Casing-C.I. IS:210, FG260
b) Impeller - CF8M(ASTM S743 Gr CF8M)
c) Shaft - SS ASTM A 276 CL 410
d) Shaft Sleeves-SS ASTM A 276 CL 410
e) Neck Ring- CF8M(ASTM S743 Gr CF8M)
f) Discharge-467 M³/Hour, Head-93.56 Mtr.
(H-Q-P Curve of Pumps has to be submitted during the delivery)
(Make:-Wilo/Mather & Platt /Other approved make)(Supplied pump's base should be capable of installing 225 KW/300 HP induction motor, base frame No-ND355L)
The pump shall Capable of operating independently and in parallel with other existing pump) | 1 | Set | - | - |
| 1.06 | Eccentric reducer 400 mm X 200 mm, thickness 6 mm, as per IS:2062. | 1 | No | - | - |
| 1.07 | Concentric enlarger 150 mm X 300 mm, thickness 6 mm, as per IS:2062. | 1 | No | - | - |
| 1.08 | 400 mm dia slip on flange, as per IS:1538, 15 mm thick. | 4 | Nos | - | - |
| 1.09 | 300 mm dia slip on flange, as per IS:1538, 15 mm thick. | 1 | No | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.97 MB
Tendernotice_2.pdf
PDF • 0.53 MB
Tendernotice_3.pdf
PDF • 0.38 MB
BOQ_2545962.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .