PROVISION OF GEYSER FOR JCOS/OR MARRIED ACCOMODATION IN DEEPAK SINGH ENCLAVE , OR BATHROOM OF BLDG NO P-12 (OTM) AND SPECIAL REPAIR / REPLACEMENT TO BER GEYSERS AND CONNECTED WORKS UNDER GARRISON ENGINEER AMRITSAR CANTT
2023_MES_632526_1
GE/ASR-72/2023-24
Open Tender
Civil Works
Works
180 days
GE Amritsar
class D category b i
8 documents required · 8 mandatory
₹500
GE Amritsar
₹62,040
17 Sept 2024
13 Dec 2023
11 Jan 2024
13 Dec 2023
10 Jan 2024
28 Dec 2023
Amount
Supply and Fixing Storage water heater (Geyser) of 25 litre capacity 230V AC, 50HZ having element of 2 KW of INCOLOY alloy with glass coating , Rust proof outer body,high density PUF insulation, BEE 5 Star Rated and above ,Inner tank of Stainless Steel (SS 304) which can sustain pressure of minimum 8 Bar working pressure and having multifunction safety valve, making electric and water connection ; Complete all as specified and directed by Engineer-in-charge. AC/SRW-01/23-24 : 115 No AC/M/19/23-24 :35 No
Supply and Fixing Storage water heater (Geyser) of 50 litre capacity 230V AC, 50HZ having element of 3 KW of INCOLOY alloy with glass coating , Rust proof outer body,high density PUF insulation, BEE 5 Star Rated and above ,Inner tank of Stainless Steel (SS 304) which can sustain pressure of minimum 8 Bar working pressure and having multifunction safety valve, making electric and water connection ; Complete all as specified and directed by Engineer-in-charge. AC/SRW-01/23-24 : 12 No AC/M/16/23-24 :08 No
Material and labour for Point wiring for Geyser / AC controlled by one 1-way switch complete with 4 Sq mm (nominal area) FRLS, PVC insulated, un-sheathed and stranded copper conductor cable ISI marked, in and including PVC concealed conduit ISI marked of size 20 mm dia medium grade and 1.5 mm wall thickness and PVC conduit fittings such as tees, bends,‘elbow, reducers except conduit junction box (junction box will be of MS) including cutting and chasing and 4 Sq mm (nominal area) FRLS, PVC insulated, un-sheathed and stranded copper conductor cable ISI marked as earth wire, connecting to common earth dolly with thimble, including pressed steel powder coated MS sunken box of suitable size, covered with & including 3 mm thick bakelite, laminated hylem sheet top cover and making good surface as original by plastering and whitewash/ colour/ distemper etc ; Complete all as specified and directed by Engineer-in-charge. (The cost of MS sunken box and bakelite sheet is included in the quoated. rate.
Material and labour for Point wiring for Geyser / AC controlled by one 1-way switch complete with 4 Sq mm (nominal area) FRLS, PVC insulated, un-sheathed and stranded copper conductor cable ISI marked, in and including PVC casing caping ISI marked and 4 Sq mm (nominal area) FRLS, PVC insulated, un-sheathed and stranded copper conductor cable ISI marked as earth wire, connecting to common earth dolly with thimble, including pressed steel powder coated MS sunken box of suitable size, covered with & including 3 mm thick bakelite, laminated hylem sheet top cover and making good surface as original by plastering and whitewash/ colour/ distemper etc ; Complete all as specified and directed by Engineer-in-charge. (The cost of MS sunken box and bakelite sheet is included in the quoated. rate.
Supply and Fixing Switch socket combination 2 in 1, 5 pin, 5 and 16 Amp flush type universal ; Complete all as specified and directed by Engineer-in-charge.
Supply and fixing of PVC Connection (Hot) of size 15 mm x 600 mm coated with stainless steel metal ; Complete all as specified and directed by Engineer-in-charge.
Supply and fixing galvanized iron steel tubing medium grade 15 mm bore with all fitting and fixed to walls, ceiling and laid in floor complete all as specified Note- Quoted rate will include the cost of making water connection from existing supply line and making good of the wall surface etc all as specified.
Supply and fixing CPVC pipes SDR 11 and plain CPVC SDR 11 fittings 20 mm bore with all fitting and fixed to walls, ceiling and laid in floor ; Complete all as specified and directed by Engineer-in-charge. Note- Quoted rate will include the cost of making water connection from existing supply line and making good of the wall surface etc all as specified.
Supply and fixing CPVC pipes SDR 11 and plain CPVC SDR 11 fittings 25 mm bore with all fitting and fixed to walls, ceiling and laid in floor complete all as specified Note- Quoted rate will include the cost of making water connection from existing supply line and making good of the wall surface etc; Complete all as specified and directed by Engineer-in-charge.
Supply and fixing of brass chormium plated angle valve, fancy type of size 15mm dia screwed down for high pressure,; Complete all as specified and directed by Engineer-in-charge. .Make- Jaquar or equivalent.
Supply and fixing Brass chromium plated fancy type bib tabs of size 15 mm dia bore short body, screwed down for GI pipe or for brass ferrule and fixed ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing in repairs MCB SP single pole, 240 volts, 20 Ampere, rupturing capacity 10 KA, ‘B’ curve type ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing Single pole and neutral enclosure 20 A ,230 V with a two pin and earth plug and socket complete with one double pole MCB 32A ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing MCB DP single pole, 240 volts, 32 Ampere, rupturing capacity 10 KA, ‘c’ curve type ; Complete all as specified and directed by Engineer-in-charge.
Material and Labour for sub main wiring with 1100 volt grade two single core PVC insulated and unsheathed cable with stranded copper conductor 4.0 sqmm drawn into and including electrical grade PVC conduit not less than 25 mm dia with IS 9537 (Part-III) 1983 mark, or relevant ISI mark with all accessories fixed concealed including chase cutting in brick/ stone masonry for fixing conduit and making good the disturb surfaces of wall as per existing including 2.5 sqmm multi - stranded copper conductor as earth wire in green colour ; Complete all as specified and directed by Engineer-in-charge.
Disconnecting and dismantling the Old unserviceable geyser from the Bldg and depositing the same with all assessories at AGE EM store yard ; Complete all as specified and directed by Engineer-in-charge.
Dismantlig floor or wall tiling including cement mortar bedding,removing rubbish of premises ; Complete all as specified and directed by Engineer-in-charge.
Supply and fixing glaze ceremic colour tile 450 mmX 300mmX7mm /300mmX200mmX7mm thic etc on vertical surfaces such as skirting ,dadop etc set and jointed in neat cemented slurry and pointed in white cement mixed with pigment to match over and including 10mm thick rendering plaster in cement mortar 1:4 on brick surface ; Complete all as specified and directed by Engineer-in-charge.
Supply and fixing rotational moulded polythelene water storage tanks(Triple layer) capacity 500 litres(cylindrical vertical with closed top), with and including 20mm dia float valve with brass fittings hoisted, fixed in position and making connection including iron staging for tank ; Complete all as specified and directed by Engineer-in-charge.
Material & labour for earthing complete with galvanised earth plate electrode 600mm X 600mm X 6mm thick burried directly in ground (earth pit not less than 2.25 m below ground level) with top edge of earth plate not less than 1.5 m below normal ground level, connected to galvanised earth wire 4 mm by means of nuts, bolts, check nuts & washers of galvanised iron or steel all as shown on electrical plate No. 3 of MES schedule 2009, Part – I (Specifications) and connected to main switch board / main DB’s / earthing test point including all necessary excavation and earth work in any type of soil, adequate quantity of charcoal dust & common salt all around the earth plate minimum 150 mm in all directions with & including watering pipe 20 mm dia GI medium grade, GI funnel made out of 0.63 mm thick GI sheet, wire gauge, 50 mm thick RCC cover in PCC 1:2:4, type B-1 (using 20 mm graded crushed stone aggregate), duly reinforced with 6 mm dia mild steel round bars @ 150 mm both ways center to center with suitable lifting handle to cover, earth pit of PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate), GI protection pipe light grade 15 mm bore up to 7.5 m length from earth electrode & engraving of earth marking on nearby building with CM 1:4 plate size 200mm X 150mm X 15mm & painting of earth result etc. including testing on ; complete all as specified and directed by Engineer-in-Charge.
kailu construction co
Bharat Builder
R D Bansal
dinesh enterprises
UNITED ENGINEERING CORPORATION
HARPAL ENGINEERS AND BUILDERS
CHOUDHARY AND SONS
AZAD SERVICES
PAWAN KUMAR GOVT. CONTRACTORS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .