Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.7 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹20.0 L+₹25,450 (1.29%)Rejected-Finance RAM SHIV COLONY GALI NO 2 NAIKA CHATNAG ROAD JHUNSI PRAYAGRAJ UP 211019 | PRAYAGRAJ | UTTAR PRADESH | 211019 | L2 | Rejected-Finance Rejected | |
| 3 | L3₹21.9 L+₹2.1 L (10.8%)Rejected-Finance H NO 273 VPO SURHERA WEST DELHI 110043 | WEST DELHI | DELHI | 110043 | L3 | Rejected-Finance Rejected | |
| 4 | L4₹24.2 L+₹4.5 L (22.7%)Rejected-Finance | L4 | Rejected-Finance Rejected | |
| 5 | L5₹25.5 L+₹5.7 L (29.0%)Rejected-Finance | L5 | Rejected-Finance Rejected |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
19 May 2022, 6:00 pmClosed
GE Faridkot
GE Faridkot Military Station
Maint Servicing of STPs IPS Central Sewage sump House cleaning of various tanks and sewage sump and other allied works at Faridkot Mil Stn
2022_MES_518952_1
GE FRD-10/2022-23
Open Tender
Civil Works
Item Rate
240 days
GE Faridkot
Class D and above and caterogy b i
8 documents required · 8 mandatory
₹500
GE Faridkot
₹60,000
Yes
2 Jun 2022
20 Apr 2022
21 May 2022
20 Apr 2022
19 May 2022
5 May 2022
Amount
Taking proper shut down in writing, disconnecting all the electrical connections, dismantling the motor of capacity 7.5 / 5 HP, 3 Phase, 415 volts,from the base plate and pump and transporting the same for repair to workshop , dismantling and strip opening of worn out /defective non clog submersible electric motor , taking out brunt stator winding , servicing, cleaning of stator slots, bearing, bushes etc, rewinding of stator coils with superior quality copper enamelled wire of existing size and specification including insulating material, varnishing and drying and re-assembling , installed, testing and connected at original location, applying two coats of synthetic enamel paint to motor and making celectric onnection complete all as specified and directed. Note :Charges of loading & unloading,transportation,change of unserviceable nut & bolts and necessary concrete work shall be deemed to be included in the quoted rate.
All as per Srl item No. 1 here-in-before but capacity of motor 1 to 3 HP complete all as specified and directed.
Taking proper shut down in writing, disconnecting all the electrical connections, dismantling the TEFC motor of capacity 40 HP, 3 Phase, 415 volts,from the base plate and pump and transporting the same for repair to workshop, dismantling and strip opening of worn out/ defective motor, taking out burnt stator winding, servicing, cleaning of stator slots, bearing, bushes etc, rewinding of stator coils with superior quality copper enamelled wire of existing size and specification including insulating material, varnishing andand drying and re-assembling , installed, testing and connected at original location, applying two coats of synthetic enamel paint to motor and making celectric onnection complete all as specified and directed. Note :Charges of loading & unloading,transportation,change of unserviceable nut & bolts and necessary concrete work shall be deemed to be included in the quoted rate.
All as per Srl item No. 3 here-in-before but motor of capacity 20/12.5 HP complete all as specified and directed.
All as per Srl item No. 3 here-in-before but motor of capacity 10/7.5 HP complete all as specified and directed.
Taking proper shut down in writing, disconnecting all the electrical connections, dismantling the motor of capacity 15/20 HP, 3 Phase, 415 volts,from the base plate and pump and transporting the same for repair to workshop, dismantling and strip opening of worn out/ defective motor, taking out burnt stator winding, servicing, cleaning of stator slots, bearing, bushes etc, rewinding of stator coils with superior quality copper enamelled wire of existing size and specification including insulating material, varnishing andand drying and re-assembling , installed, testing and connected at original location, applying two coats of synthetic enamel paint to motor and making celectric onnection complete all as specified and directed. Note :Charges of loading & unloading,transportation,change of unserviceable nut & bolts and necessary concrete work shall be deemed to be included in the quoted rate.
M&L for repair and servicing to submersible motor, 3 phase 415 volts, capacity 5/7.5 HP, by dismantling the motor from the pump set, removing the stator/rotor seperately, cleaning, varnishing, heating and drying re-erecting, testing including replacement of DE and NDE bearings including painting the motor with two coats of synthetic enamel paint after preparing the surfaces all as directed. Note : Cost of Bearings of motor shall be deemed to be included in the quoted rate.
All as per Srl item No. 7 here-in-before but of capacity 10/12.5 HP complete all as specified and directed. Note : Cost of Bearings of motor shall be deemed to be included in the quoted rate.
All as per Srl item No. 7 here-in-before but of capacity 3 HP complete all as specified and directed. Note : Cost of Bearings of motor shall be deemed to be included in the quoted rate.
All as per Srl item No. 7 here-in-before but of capacity 15/20 HP complete all as specified and directed. Note : Cost of Bearings of motor shall be deemed to be included in the quoted rate.
All as per Srl item No. 7 here-in-before but of capacity 40 HP complete all as specified and directed. Note : Cost of Bearings of motor shall be deemed to be included in the quoted rate.
M & L for maintenance, servicing, oiling and greasing of air blower assembly, draining out compressor chamber oil, washing out and refilling with new oil of existing specification as recommended by manufacturer including replacement of lubricating oil filter media, air filter media,fan belt (set of three) and minor spare parts, fitting and fastners deemed essential to make system serviceable, smooth and noise free complete all as specified and directed.
Supply only Sodium hypochloride solution IS-11673 Grade-II for disinfection of treated water complete all as specified and directed. Note : RV shall be prepared for supply & consumption duly verified by audit authority. Note : Hypochloride solution shall be conforming to IS-11673-1992 and shall be supplied in packed containers. The contractor shall produce test certificates of the hypochloride solution issued by factory/ District Govt Food Inspection lab to ascertain the presence of the chlorine percentage in the consignment. In addition, independent testing for the material shall be got done by the Engineer-in-Charge to verify and check the quality .
S&F in replacement ASD non clog submersible pump controller (Standard), 3 phase,415 volt, suitable for 5 HP submersible pump complete all as specified and directed.
All as per Srl item No 14 here-in- before but for capacity 7.5 HP complete all as specified and directed.
S&F in replacement fully automatic, air break, star delta electric motor starter, 3 phase, 415 volt, suitable for 40 HP motor, Amp range 55-70 complete all as specified and directed.
S&F in replacement fully automatic, air break, star delta electric motor starter, 3 phase, 415 volt suitable for 20 HP motor, Amp range 28-36 complete all as specified and directed.
S&F in replacement fully automatic, air break, star delta electric motor starter, 3 phase, 415 volt suitable for 10/15 HP motor, Amp range 28-36 complete all as specified and directed.
S&F in replacement DOL starter, push button type, suitable for 5/7.5HP, 3 phase 415 V,AC electric motor complete all as specified and directed.
S&F in replacement MCCB, 3 phase, 4 Pole, 415 volts, of capacity 63 Amps, short circuit breaking capacity 25 KA, fixed thermal and fixed magnetic setting, conforming to IS-13947 Part-III-1993 and IEC-60947 (Part-2) including copper extension terminals thimbles, nut, bolts, washers etc complete all as specified and directed.
M&L for replacement of MCCB, 3 phase, 4 Pole, 415 volts, of capacity 100 Amps, short circuit breaking capacity 35 KA, fixed thermal and fixed magnetic setting, conforming to IS-13947 Part-III-1993 and IEC-60947 (Part-2) including copper extension terminals thimbles, nut, bolts, washers etc complete all as specified and directed.
S&F in replacement PVC insulated, submersible cable of size 10 Sqmm, 1100 Volt,3 core, flat, copper conductor (including jointing material) complete all as specified and directed.
All as per item No 22 here in before but of size 16 Sqmm complete all as specified and directed.
S&F in replacement butterfly valve of size 100 mm dia complete all as specified and directed.
Supply and fix in replacement butterfly valve of size 80 mm dia complete all as specified and directed.
Supply and fix in replacement butterfly valve of size 65 mm dia complete all as specified and directed.
Supply and fix in replacement butterfly valve of size 50 mm dia complete all as specified and directed.
S &F in replacement pressure gauge of size 4 '', O-10 Kg/cm², dial type complete all as specified and directed.
S&F gland packing in packets of standard length suitable for 40 HP motor pump complete all as specified and directed.
S&F gland packing in packets of standard length suitable for 20/12.5 HP motor pump complete all as specified and directed.
S&F in replacement gland plate made out of Mild steel suitable for 3 to 10 HP non clog pump set complete all as specified and directed.
Collection of sample of sewage water from sewage treatment plant and testing it through Govt approved laboratory for testing the pH, COD (mg/l), BOD (mg/l), TSS (Mg/l), Oil and grease (mg/l) & coliform count/100ml complete all as specified and as directed.
Material and labour for Tube Settler modules made of PVC and as per existing specification complete all as specified and directed.
Supply only grease SG-240/LG-280 required for periodical maintenance/repair of STP complete all as specified and directed. Note : RV shall be prepared for supply & consumption duly verified by audit authority.
M&L for filter stone sand media 5 to 10mm same as existing specification and size to be incorporated for sludge drying beds complete all as specified and directed.
M&L for MBBR media made of poly propylene with virgin plastic UV stabilized milky white specific gravity 0.95 to 0.98 complete all as specified and directed.
M&L for desludging of silt/sludge,weeds,bushes ,vegetation of equalisation tank of dia 450cm including cleaning /opening of choked / jammed suction/delievery lines of sewage pump in sump well fitted with submersible sewage pump set by rodding, air pressure or other mechanical means for removing of setteled down sludged at the bottom of sump well and made the line serviceable complete all as specified and directed. Note : Dewatering/desludging of tank shall be carried out through own arranged pumpimg set without damaging the the tank and cost of the same shall be deemed to be included in quoted rates.
M&L for desludging of silt/sludge,weeds,bushes ,vegetation of equalisation tank of dia 950cm including cleaning /opening of choked / jammed suction/delievery lines of sewage pump in sump well fitted with submersible sewage pump set by rodding, air pressure or other mechanical means for removing of setteled down sludged at the bottom of sump well and made the line serviceable complete all as specified and directed. Note : Dewatering/desludging of tank shall be carried out through own arranged pumpimg set without damaging the the tank and cost of the same shall be deemed to be included in quoted rates.
S&F MS nuts, bolts, washers and MS blind plate 3mm thick complete all as specified and directed.
S&F in replacement of sluice valve of size 150mm,class PN-1.6 ( ISI marked) with brass spindle, flanged end including jointing with Neoprene rubber gasket, nuts, bolts and washers etc as per existing complete all as specified & directed .
S&F in replacement of sluice valve of size 100mm,class PN-1.6 ( ISI marked) with brass spindle, flanged end including jointing with Neoprene rubber gasket, nuts, bolts and washers etc as per existing complete all as specified & directed .
Cast iron fitting for flanged pipe i.e bends, tappers, Tee pieces/single & double branch any type and angle / radius and straight connecting pieces all end flanged upto 150mm bore complete all as specified and directed.
S & F in replacement cast iron pipe with flanged ends, 150 mm dia,centrifugally cast,class B laid in trenches complete all as specified and directed.
Supply, laying, jointing, commissioning and testing in replacement Ductile iron pipes, 100mm bore with spigot and socket ends , centrifugally cast (Spun), Class K-7 conforming to IS-8329-2000 in any length with & including rubber push (Tyton) joint laid in trenches complete all as specified and directed.
Supply, laying, jointing, commissioning and testing in replacement Ductile iron pipes, 150mm bore with spigot and socket ends , centrifugally cast (Spun), Class K-7 conforming to IS-8329-2000 in any length with & including rubber push (Tyton) joint laid in trenches complete all as specified and directed.
S&F in replacement rigid PVC pipe of size 150mm dia bore, working pressure rating 10 Kgf/cm² fixed in wall, ceiling or in floor complete all as specified and as directed.
All as per Sel item No 46 here -in-before but of size 100mm dia bore complete all as specified and as directed.
S&F single phase preventor suitable for all type of motor complete all as specified and directed.
S&F in replacement MS pipe of size 100mm dia, heavy duty grade, with all fittings, laid in floors or fixed to wall and ceiling etc complete all as specified and directed.
S&F in replacement MS pipe of size 80mm dia, heavy duty grade, with all fittings, laid in floors or fixed to wall and ceiling etc complete all as specified and directed.
S&F in replacement MS pipe of size 65mm dia, heavy duty grade, with all fittings, laid in floors or fixed to wall and ceiling etc complete all as specified and directed.
S&F in replacement MS pipe of size 50mm dia, heavy duty grade, with all fittings, laid in floors or fixed to wall and ceiling etc complete all as specified and directed.
S & F carbon for activated carbon filter and dual media filter complete all as specified and directed.
Excavation in trenches in soft/loose soil not exceeding 1.5m deep and 1.5m wide, for foundation etc or manholes,piers,shafts etc not exceeding 10 Sqm on plan and getting out complete all as specified and directed
Returning, filling in,including spreading, leveling, watering and well ramming in layers not exceeding 25cm complete all as specified and directed
Removal of surplus soil to a distance not exceeding. 50 m & depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed Note :- A Sum of Rs. 57050.00 will be deducted on account of credit for dismantling/ demolished/taking down material. Please refer detail on srl page No 19 (Schedule of credit) of Tender Documents.
TARA ENTERPRISES
M/S RAJESH KUMAR and CO.
NAV DURGA CONSTRUCTION CO
NEW AMRITSAR CONSTRUCTION COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .