GE AF PANAGARH
GE AF PANAGARH MES AF STATION PANAGARH PO BIRUDIAH WEST BENGAL 713148
REPAIR/MAINT OF SPLIT TYPE AC, FLAMEPROOF TYPE AC ,DEEP FREEZERS/SUMMER AND WINTER APPLIANCES WATER COOLER AND CONNECTECTED ITEMS INSTALLED AT AFS PANAGARH UNDER GE (AF) PANAGARH
2025_MES_693515_2
C/8814/E8
Open Tender
Electrical and Maintenance Works
Item Rate
210 days
AF STATION PANAGARH
Please refer tender document
7 documents required · 7 mandatory
₹500
GE AF PANAGARH
₹18,700
22 May 2025
5 Mar 2025
2 Apr 2025
5 Mar 2025
31 Mar 2025
12 Mar 2025
Amount
Servicing and maintanance of Split AC 1.5/2.0 ton capacity complete indoor / outdoor unit installed upto 3 meter height for routine check up for smoth functioning checking of refrigerant gas, gas leakage, cheking the functioning of compressor, blower motor, all electrical / electronic circuit, functioning of remote, functioning cooling system, cleaning and washing by using vaccum cleaner/ water spray/ mild liquid soap, seal of air filters, cooling coil, condensor coil, blower motor, fan motor etc. complete indoor / outdoor unit all as directed by Engr-in-charge. (Note : (i) Spares required will be measured and paid separately) (ii) Servicing of Split AC 1.5 / 2.0 Ton capacity should be done by OEM or authorize channel partner.)
All as per above item No 01 but out door unit installed more than 3m from the ground level. (Note : (i) Spares required will be measured and paid separately (ii) Servicing of Split AC 1.5 / 2.0 Ton capacity should be done by OEM or authorize channel partner.(iii) Bidders are requested to visit the site before quoting the rate)
Servicing and maintanance of window AC 1.5 ton capacity complete unit for routine check up for smoth functioning checking of refrigerant gas, gas leakage, cheking the functioning of compressor, blower motor, all electrical/electronic circuit, functioning of cooling system, cleaning and washing by using vaccum cleaner/ water spray/ mild liquid soap, seal of air filters, cooling coil, condensor coil, blower motor, fan motor etc. complete unit all as directed by Engr-in-Charge. (Note : (i) Spares required will be measured and paid separately (ii) Servicing of Windo AC 1.5 Ton capacity should be done by OEM or authorize channel partner.)
Servicing and maintanance of flame proof split AC 1.5 ton capacity complete unit for routine check up for smooth functioning checking of refrigerant gas, gas leakage, cheking the functioning of compressor, blower motor, all electrical/electronic circuit, functioning of cooling system, cleaning and washing by using vaccum cleaner/ water spray/ mild liquid seal liquid of air filters, cooling coil, condensor coil, blower motor, fan motor etc., complete unit all as directed by Engr-in-Charge. (Note :(i) Spares required will be measured and paid separately (ii) Servicing of flame proof Split AC 1.5 Ton capacity should be done by OEM or authorize channel partner.))
Taking out existing burnt / unserviceable compressor unit from 1.5 ton capacity of window/split type air conditioner and replacing the same with factory built hermetically sealed rotary new compressor sealed unit including necessary accessories and mounting materials, welding, leak testing by charging with CO2/dry nitrogen gas. Evacuating the system and charging of R-22 Refrigerant gas after ensure leak proof condition and testing complete all as directed. (Note - Refrigerant gas in required quantity shall be measured and paid separately under relevant items of Schedule 'A')
All as per item No 5 here-in- before but of capacity 2.0 ton
Taking out existing burnt / unserviceable compressor unit from 1.5 ton capacity of flame proof split type air conditioner and replacing the same with factory built hermetically sealed rotary compressor unit including necessary accessories and mounting materials, welding, leak testing by charging with CO2/ dry nitrogen gas. Evacuating the system and charging of R-22 Refrigerant gas after ensure leak proof condition and testing complete all as directed. (Note - Refrigerant gas in required quantity shall be measured and paid separately under relevant items of Schedule 'A'.)
Taking Down of existing damaged / burnt blower motor from split/window type AC and supply & fixing of new blower motor with capacitor & mounting materials single phase, 230 Volts 50 Hz suitable for 1.5 ton & 2 ton capacity of window/Split type AC complete all as specified and directed.
Taking Down of existing damaged / burnt blower motor from flame proof split AC and supply & fixing of new blower motor with capacitor & mounting materials single phase, 230 Volts 50 Hz suitable for 1.5 ton & 2 ton capacity of flameproof split type AC complete all as specified and directed.
Taking Down of existing damaged / oudoor fan motor from split / window/flame proof AC (1.5 / 2 Ton capacity) and replace the burnt unserviceable parts, refixing the same after repair and testing its proper function complete all as directed by Engr-in-Charge.
Taking out damaged metallic / PVC fan blade from window/split/flame proof AC 1.5/2 ton and Supply & fix new PVC fan blade of existing size suitable for 1.5/2 ton window/split type AC/flame proof AC complete all as specified and directed.
Taking out the unserviceable running capacitor and supply and fix new running capacitor of 36/45/50 MFD for 1.5/2.0 ton window/split type AC/flame proof AC complete all as specified and directed.
M&L for charging of refrigerant R-22 HydroChloroFluoroCarbon (HCFC) compound having low chlorine content and ozone depletion potential including cost of leak detection, welding, and refitting the same in entire system as required, including replacing defective liquid strainer, capillary tube of various capacities / types of Air Conditioners installed at any height, testing for its satisfactory operation complete all as directed by Engineer-in-Charge.(Note : Original purchase voucher of gas having GST No shall be submit before payment claim duly entered in measurementbook )
All as per above item No. 13 but R-410a (Pentafluoroethane, Difluoromethane) refrigerant.
All as per above item No. 13 but R-32 (difluoromethane) refrigerant.
M&L for taking out unserviceable PCB unit from split/window AC/ flameproof AC of 1.5/2.0 capacity (inverter/ non inverter) and replace the burnt unserviceable electronic parts, refixing the same after repair and testing its proper function complete all as directed by Engr-in-Charge
Taking out unserviceable burnt PCB unit from non inverter split/Window type AC/flame proof AC and supply and fixing of new PCB unit suitable for existing Split/window AC/flame proof AC of 1.5/2.0 Ton capacity complete all as specified and as directed.
Taking out unserviceable burnt duel PCB unit from inverter split AC/flame proof AC and supply and fixing of new PCB unit suitable for existing Split/Flame proof AC of 1.5/2.0 Ton capacity complete all as specified and as directed.
Taking out unserviceable swing motor from split/window AC/flameproof AC indoor unit and supply and fixing new swing motor suitable for 1.5/2.0 Ton split/window AC/ flameproof AC complete all as specified and as directed.
Taking out unserviceable existing cooling coil unit from window/split AC/flame proof AC of 1.5/2.0 ton capacity and supply and fixing of new cooling coil with thermostat complete all as specified and directed.
Taking out unserviceable existing condensing coil unit from window/split AC/flame proof AC of 1.5/2.0 ton capacity and supply and fixing of new condencing coil with thermostat complete all as specified and directed.
M& L for Split AC mild steel powder coated brackets for mounting outdoor unit as per existing size after taking down old damage brackets complete all as specified and directed.
Taking down the exisiting indoor and outdoor unit of Split/window Air Conditioner/flameproof AC from any location / any capacity and refixing the same at new said location complete all as specified and as directed. (Note : (a) Necessry regrigirant gas,copper pipes with insulaton will be measured and paid separetely. (b) All the other miscelleneous items required for fixing is deemed to be included in the quoted rate.)
Taking out existing burnt / unserviceable compressor unit from 208 ltrs capacity Refrigerator & replacing the same with factory built hermetically sealed new compressor unit including necessary accessories and mounting material, welding, leak testing by charging dry Nitrogen gas, charging of refrigerant R-134 A after ensuring leak proof condition. Testing complete all as directed by Engineer-in-Charge. (Note: Refrigerant gas shall be measured and paid separately. )
S&F for new thermostatic switch for 208 to 310 capacity refrigerator after taking out defective thermostatic switch complete all as specified and directed..
S&F for new Refrigerator freezer chamber of capacity 208 ltrs to 310 ltrs after taking out defective Refrigerator freezer chamber complete all as specified and directed.
S&F for new starting relay cum over load protector for refrigerator upto 315 ltrs capacity as per existing make and model of the refrigerator after taking out faulty starting relay cum over load protector complete all as specified and directed.
Taking out existing burnt / unserviceable compressor unit from 40/80 ltrs capacity water cooler & replacing the same with suitable factory built hermetically sealed rotary new compressor unit including necessary accessories and maintaining material, welding, leak testing by dry Nitrogen gas and charging R-134A refrigerant gas after ensuring leak proof condition and testing completed all as directed by Engineer-in-Charge.
S&F for new starting relay suitable for water cooler of capacity 40 / 80 ltrs after taking out defective / unserviceable starting relay complete all as specified and directed.
S&F for new running capacitor suitable for water cooler of capacity 40 / 80 ltrs after taking out defective / unserviceable running capacitor complete all as specified and directed.
S&F for new over load protector suitable for water cooler of capacity 40 / 80 ltrs after taking out defective / unserviceable over load protector complete all as specified and directed.
S&F for new thermostatic switch suitable for water cooler of capacity 40 / 80 ltrs after taking out defective / unserviceable thermostatic switch complete all as specified and directed.
S&F for new PVC connection pipe 15 mm dia of 450 mm long suitable for water cooler of capacity 40 / 80 ltrs after taking out unserviceable PVC connection pipe complete all as specified and directed.
Supply and charging of refrigerant R-134A including cost of welding, leak detection and rectification in the entire system with replacement of liquid strainer and capillary tube including testing of water cooler of capacity 40 / 80 ltrs and refrigerator of capacity 208 ltr to 310 ltr including testing for its satisfactory operation complete all as directed by Engineer-in-Charge.(Note : Original purchase voucher of gas having GST No shall be submit before payment claim duly entered in measurementbook )
Taking out of existing damaged / burnt blower motor and supply and fixing of new blower motor, single phase, 230 Volts, 50 Hz suitable for water cooler of capacity 40/80 ltrs including fixing arrangement complete all as directed by Engineer-in-charge. (Note : Necessary fixing material for the same is deemed to be included in the quoted rate.)
S&F for new stabilizer 4 KVA/5 KVA capacity after taking out of existing damaged / burnt voltage stabilizer of 4 KVA/ 5 KVA capacity complete all as directed by Engineer-in-charge. (Note : Original purchase voucher of stabilizer having GST No shall be submit before payment claim duly entered in measurementbook )
S&F for new auto transformer of voltage stabiliser 4 KVA / 5 KVA capacity after taking out defective / burnt auto transformer complete all as specified and directed.
S&F for new PCB complete with components of capacity 4 KVA / 5 KVA Voltage stabilizer after taking out defective PCB (Printed Circuit Board) complete with components complete all as specified and directed.
S&F for new relay for voltage stabiliser upto 5.0 KVA capacity after taking out faulty relay complete all as specified and directed.
S &F for PVC insulated copper cable 3 core 4 Sqmm sheathed after taking down the unserviceable cable complete all as specified and as directed.
S& F for insulating material for Air Conditioner copper pipe of Suction,discharge,liquid line of various sizes. The insulating material shall have low conductivity, strength, Resistance to Fungi such as one that is based on ASTM G21 standard, excellent resistance to ozone and UV including removing the old insulation complete all as specified and as directed.
S &F for 1/2 " copper pipe (12.7mm) copper pipe of 3mm thick wall thickness for any type/capacity of Air Conditioners installed at any height of the building or hanger with necesssary flaring and jointing arrangements including taking down the unserviceable copper pipe complete all as specified and as directed.
S &F for 3/4 " copper pipe (19.05mm) copper pipe of 3mm thick wall thickness for any type/capacity of Air Conditioners installed at any height of the building or hanger with necesssary flaring and jointing arrangements including taking down the unserviceable copper pipe complete all as specified and as directed.
S & F for 5/8 " copper pipe (15.875mm) copper pipe of 3mm thick wall thickness for any type/capacity of Air Conditioners installed at any height of the building or hanger with necesssary flaring and jointing arrangements including taking down the unserviceable copper pipe complete all as specified and as directed.
S & F for 15 mm dia Drain pipe for AC of any capacity after taking down old drain pipe complete all as specified and as directed.
S & F for copper Cappilary tube as per existing AC/Water cooler/Refrigerator after taking down of old/ unserviceable copper capplilary tube complete all as specified and directed.
S &F for Deforst element for refrigeritaor/Deep freezer after taking down of old/ unserviceable deforst element complete all as specified and as directed.
S &F for Dryer/Strainer for refrigeritaor/Deep freezer/ Water cooler after taking down of old unserviceable dryer/stainer complete all as specified and as directed.
S &F for modular plug and socket 25 Amp, 3 Pin 3 Pole having 6 modules having motor starter Modular Type 25 A, MCB mini SPN 25A 3 KA, Socket 25A, suitable for Air-condition supply,240 volts, AC, 50 Hz after taking down of old unserviceable plug and socket complete all as specified and as directed ,
MS FORWARD BUILDERS E 32/10/KKD (BID ID -3263205)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .