Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹22.2 CrAdmitted-Finance | -1.13% | ₹22.2 Cr | L1 | Admitted-Finance |
| 2 | L2₹22.8 CrAdmitted-Finance 1 513 VIDHYADHAR NAGAR JAIPUR 302039 RAJASTHAN | JAIPUR | RAJASTHAN | 302039 | -5.20% | ₹22.8 Cr | L2 | Admitted-Finance |
| 3 | L3₹24.0 CrAdmitted-Finance 216 C SIVA COLONY MAYO LINK ROAD AJMER RAJASTHAN 305007 | AJMER | RAJASTHAN | 305007 | +6.88% | ₹24.0 Cr | L3 | Admitted-Finance |
Tender Value
₹23.2 Cr
EMD Value
₹46.5 L
Closing Date
4 Apr 2023, 12:00 pmClosed
Secretary
uit alwar
PROPOSED OF MULTI-LEVEL (2 FLOOR) BASEMENT PARKING AT COMPANY GARDEN, ALWAR, RAJASTHAN.
2023_UITAL_322766_1
NIT57/2022-23/Item2
Open Tender
Civil Works
450 days
UIT Alwar
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,500
Secretary, UIT
₹46.5 L
Yes
17 Apr 2023
3 Mar 2023
4 Apr 2023
3 Mar 2023
4 Apr 2023
3 Mar 2023
Amount
CIVIL WORK
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
SITE DEVELOPMENT
Providing & Laying 30mm thick Drainboard which are made with highly recycled HDPE material which can give long term pressure resistance and drainage alternatives used for Waterproofing & also used in the roof garden, football field, basement, slopes, complete in all respect as directed by EIC
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
ELECTRICAL WORK
SITC of 2 MP IR Fixed Dome Network Camera -1/2.7″ Progressive Scan CMOS, 1920 × 1080 at 25fps, 2.8 mm Fixed lens, 0.002 Lux at F1.4, 0 Lux with IR on, ICR, ONVIF (PROFILE S, PROFILE G, PROFILE T), support H.265, H.264, MJPEG, 120db WDR, 3D Digital Noise Reduction, Three individually configurable stream, 12 VDC & PoE, IR range: 40m, Support on-board storage up to 256 GB (SD card not included), IP67, Edge Analytics- Line crossing detection, Intrusion detection, Motion detection, Video tampering, UL, CE, FCC certified.
Supply Installation testing and commissioning of 32 Ch Network Video Recorder- Connect Up to 64 IP Cameras, Up to 12 Megapixels Resolution, HDMI1/VGA1 and HDMI2/VGA2 outputs provided, atleast one HDMI output with 4K (3840 × 2160), atleast one VGA output with 2K (2560 × 1440) resolution, Support H.265/MJPEG, Supports N+1 hot spare system, Supports RAID0, RAID1, RAID5, RAID6 and RAID10, Supports HDD hot swap, Incoming Bandwidth 320 Mbps, 8 SATA Hard Disks, 1 × eSATA interface, ANR Technology, 8 SATA interfaces for 8 HDDs and capacity of each HDD upto 10 TB, Front panel: 2 × USB 2.0; Rear panel: 1 × USB 3.0, Alarm I/O 16/4, RS-232, RS-485, 2 RJ-45 10 /100/1000 Mbps self-adaptive Ethernet interface, Multiple network monitoring: Web viewer, CE, FCC, UL certified. with 30 days backup capacity asrequired.
SITC of professional PC alongwith printer and other accessories as required having minimum i7 processor, 8 GB graphic card 1 Tb SSD as per requirement.
SITC of 42 inch full HD professional LED display for CCTV monitoring.
MECHANICAL VENTILATION SYSTEM
Jet Fan
Supply, Installation, Testing, Commissioning & Handing over of the Basement Mechanical Ventilation system with Forced fresh air intake for Basement & forced exhaust for all the basement level from independent shaft arrangement.
Supply, installation testing & commissioning of dual speed high tempearture rated Jet Fans. Fan should include inlet & outlet silencers & mounting arrangements. Fan Should be capable of runing at 300DegC at least for 2 Hours once. Jet fans shall be complete with casing made of heavy gauge sheet steel, roll formed, welded and hot-dip galvanized after fabrication. Impeller (Hub and blades) shall be constructed of die cast aluminium alloy. Impeller should have aerodynamic profile. Fan to be provided with galvanised steel outlet deflector and zinc/cadminum plated inlet guard . Direction of discharge and rotation shall be marked on the fan casing. The Motor shall be run on the electrical power supply suitable for 415V/3Ph/50Hz. Make- DYNAIR/KRUGER/SYSTEMAIR
Basement-1 The Dual speed 310 Dia Fan, Capacity -2700 CFM / 1350 CFM and Motor Rating & Pole - 0.8 Kw @ 2P / 0.2 Kw @ 4P. Thrust level should not be less than 27N/07N
Basement-2 The Dual speed 310 Dia Fan, Capacity -2700 CFM / 1350 CFM and Motor Rating & Pole - 0.8 Kw @ 2P / 0.2 Kw @ 4P. Thrust level should not be less than 27N/07N
CFD ANALYSIS
Computational Fluid Dynamics (CFD) analysis for Air flow, CO & Fire Simulation for the basement.
CO Gas Detector
Supply, Installation & Commissioning of CO Gas Detector with Digital display of CO level. The detectors should be suitable for MODBUS interface. Coverage Area 700 Sq.mtr, Make Greystone/Siemen/Honeywell
Basement-1
Basement-2
Fresh Air Vane Axial Fans
Supply, installation testing & commissioning of directly driven Vane axial fan suitable for VFD operation. Each fan shall be complete with casing made from mild steel duly Powder coated, adjustable pitch die cast aluminium impeller (HUB & BLADES), suspension brackets/floor munting legs, suspension rods with spring isolator or vibration isolator for floor mounting, fire retardent fexible connection at inlet, directly coupled with TEFC Sq.cage IP-55, Class-F and IE-3 efficiency induction motor mounted on vibration isolators suitable for 415V±10% , 50 Hz. 3 phase electric supply complete as per the technical specifications.Motor shall be suitable for 415+10% volts, 50 cycles, 3 phase AC supply. The fans shall be AMCA certified for air and sound performance in accordnace to AMCA 210 and AMCA 300. The complete fan shall be tested and approved by UL / EN in accordance with "Power Ventilators for Smoke Control Systems" for 250 °C for 2 hour. Casing Thickness should be 3mm upto 1000 mm and 4 mm upto 1600 mm diameter.Noise level should be 78dB(A)@3m. Total Efficiency should not be less than 65% Make- DYNAIR/KRUGER/SYSTEMAIR, Motor Make - Havells.
BASEMENT-1 26000 CFM @ 20 mm wg static pressure and Motor :7.5. Kw /4/6 pole
BASEMENT-2 27500 CFM @ 20 mm wg static pressure and Motor :7.5 Kw /4/ 6 pole
Parking Exhaust Smoke Spill Vane Axial Fans
Supply, installation testing & commissioning of directly driven Smoke Spill Vane axial fan suitable for VFD operation. Each fan shall be complete with casing made from mild steel duly Powder coated, adjustable pitch die cast aluminium impeller (HUB & BLADES), suspension brackets/floor munting legs, suspension rods with spring isolator or vibration isolator for floor mounting, fire retardent fexible connection at inlet, directly coupled with TEFC Sq.cage IP-55, Class-H and IE-3 efficiency induction motor mounted on vibration isolators suitable for 415V±10% , 50 Hz. 3 phase electric supply complete as per the technical specifications.Motor shall be suitable for 415+10% volts, 50 cycles, 3 phase AC supply. The fans shall be AMCA certified for air and sound performance in accordnace to AMCA 210 and AMCA 300. The complete fan shall be tested and approved by UL / EN in accordance with "Power Ventilators for Smoke Control Systems" for 250 °C for 2 hour. Casing Thickness should be 3mm upto 1000 mm and 4 mm upto 1600 mm diameter.Noise level should be 78dB(A)@3m. Total Efficiency should not be less than 65% Make- DYNAIR/KRUGER/SYSTEMAIR, Motor Make - Havells.
BASEMENT- 1 : 26000 CFM @20. mm wg static pressure and Motor : 7.5 Kw / 4/6 pole
BASEMENT- 2 : 27500 CFM @20. mm wg static pressure and Motor : 7.5 Kw / 4/6 pole
Smoke/ Emergency Exhaust Smoke Spill Vane Axial Fans
BASEMENT- 1 : 26000 CFM @20 mm wg static pressure and Motor : 7.5 Kw / 4 / pole
BASEMENT- 2 : 27500 CFM @20 mm wg static pressure and Motor : 7.5 Kw / 4 /Pole
MOTOR CONTROL CENTRE PANEL WITH PLC :
Supply & Installation of MCC Electrical Panel made out of 2/1.6 mm CRCA sheet finished with Siemens Grey powder coated painting. Panel complete with Built in PLC, MCB/MPCB Feeders and Starters for Jet Impulse fans with dual speed and all Exhaust air Axial fans with VFD. All Jet Impulse Fans and Exhaust air Fans are controlled through CO level feedback by MCC Panel's PLC and all Exhaust air axial fans shall be run at full speed in case of Receipt of FIRE SIGNAL from the Fire Basement Panel to be supplied by others. The panel shall be floor mounted and top cable entry, suitable incomer MCCB, aluminum bus bar and custom built microprocessor logic controller with necessary control wiring etc.
The Main LT Panel shall use breakers suitable for 415 V AC, 3 phase, 50 Hz, 3 phase 4 wire supply system. Air Circuit Breakers,microprocessor release for overload, short circuit, instantaneous & earthfault protection with Current & Voltage metering & LCD display & should have capability to communicate ON /OFF/ Trip Status on Modbus/Ethernet and as per the detail specification of ACB (Icu=Ics=Icw=50 kA (1 sec) Make- KEPL/Allied Engineers/MAK Engineers.
Incoming
1 Nos. 315 Amp FP MCCB 25KA
Busbars
1 Nos. 320 Amp TPN busbars of COPPER as per SLD.
Outgoing
1 Sets auto trip indicating lamp .
Note: All outgoings should have ammeter and RYB indications with backup MCB as indicated in single line diagrams.
Short Circuit Breaking capacity should not less than 25KA.
Electrical Power and Control Cable
SOLAR SYSTEM
Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthingmounted on Aluminium/GI structure of suitable strength with followincomponents complete as required:a) Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. SolaPhotovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watcapacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. c) Data Monitoring System complete with accessories. d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugand other accessories etc. as required. e) Lightning and surge voltage protection. f) Connections & Interconnections by supplying & fixing required size XLPinsulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along witsupplying & fixing of necessary channel/conduit lugs and other accessories etc. as required.
ANURAG ENTERPRISES
jain builders
jain builders
LNA Infraprojects Pvt. Limited
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.83 MB
PotentialBid.pdf
Tender Documents • 0.34 MB
FinancialBid.pdf
Additional Documents • 0.14 MB
RTTPPABCDPerforma.pdf
Other Document • 0.20 MB
BOQ_572234.xls
BOQ • 1.25 MB
Download all tender documents and submit your bid