Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 CrAccepted-AOC | ₹1.4 Cr Quoted ₹1.3 Cr | L1 | Accepted-AOC The valid, lowest and negotiated tenderer |
| 2 | Rejected-Technical | - | - | Rejected-Technical Unsuccessful tenderer |
| 3 | Rejected-Technical 53 MIDDLE STREET ARUMALAI TIRUKOILUR VILLUPURAM DISTRICT | VILLUPURAM | TAMIL NADU | 604001 | - | - | Rejected-Technical Unsuccessful tenderer |
| 4 | Rejected-Technical | - | - | Rejected-Technical Unsuccessful tenderer |
| 5 | Rejected-Technical | - | - | Rejected-Technical Unsuccessful tenderer |
Tender Value
₹1.8 Cr
EMD Value
₹1.0 L
Closing Date
27 Mar 2020, 6:00 pmClosed
SUPERINTENDING ENGINEER, TNPHC LTD, NORTH CIRCLE.
The Superintending Engineer/North Circle No.1 and 7, Inspectors quarters, PGR Line, Behind CPO Building, Annadhanapatty, Linemedu, Salem - 636 006.
Construction of 1 No. of Station Fire Officer Quarters and 12 Nos. of Firemen Quarters for Fire and Rescue Service Station at Sangagiri in Salem District.
2020_TNPHC_161596_1
SE/NC/DB/0077/2020
Open Tender
Civil Works
Lump-sum
300 days
Sangagiri in Salem District.
Refer tender documents
6 documents required · 6 mandatory
₹0
₹1.0 L
17 Jun 2020
20 Mar 2020
3 Apr 2020
20 Mar 2020
27 Mar 2020
20 Mar 2020
Amount
1.1 : Earth work excavation in all soils (including refilling) a. 0 to 2 mt.
1.3 : Earth work excavation in Soft disintegrated rock (including refilling) a. 0 to 2 mt.
13.1 : Filling with Excavated Earth
21.2 : Teak wood Wrought & Put up a. T.W. over 2 m & below 3 m
b. T.W. below 2 m length.
23.3 : S&F of Magnetic door catches
24 : Manufacturing & supply of steel windows (Weight basis)
25 : M.S.Holdfast
30 : Ellispattern
31 : Weathering couse
37.1 : White washing 3 coats (slaked)
39 : M.s Grills
40 : Painting - New "wood work"
41 : Painting - New "iron work"
46 : S & F 20 mm dia Alu. Hanger Rod
47 : S & F Alu Towel rail 75 cm long
48 : S & F 5 pin Coat stand
49 : S & F chromium plated 8 guage Picture Hook
50.4 : Providing Tree guard
52 : PVC Water supply (ASTM) a. 32 mm dia
b. 25 mm dia
52.1 : Supplying and fixing of 20mm dia "B" Class GI pipe for Hot water line (Fully Concealed in walls)
Electrical arrangements 69 : 15 Amp. Power plug
72 : Box type Fibre Fan hook
74 : Charges for fixing of "Fan"
76 : 8 SWG wire
77.3 : S&F of TV/Telephone line Socket
77.4 : S&F of 20mm dia PVC pipe for TV/Telephone line
78 : Earthing Station IS3043 (Type I)
86 : Anti termite treatment
ANNEXURE 2.1.1 : Supplying and filling with gravel
2.1.3 : Filling sand (using crushed stone sand)
3.1.1 : C.C.1:5:10 for Foundation & Basement (using crushed stone sand)
6.2.1 : Brick work in C.M. 1:5 (F& B) using chamber Burnt bricks of size 23 x 11.4 x 7.5 cm (9" x 4 1/2"x 3") (using crushed stone sand)
8.1.1.1 : Standardised concrete Mix M20 Grade Concrete (using crushed stone sand) a) In Foundation and basement
b) In Ground Floor
c) In First Floor
d) In Second Floor
e) In Third Floor
f) In Fourth Floor
9.2.1 : Brick work in C.M. 1:6 using chamber Burnt bricks of size 23 x 11.4 x 7.5 cm (9" x 4 1/2"x 3")(using crushed stone sand) a. In Ground Floor/Stilt floor
b. In First Floor
c. In Second floor
d. In Third floor
e. In Fourth floor
10.2.1 : Brick partition work in C.M. 1:4 using chamber Burnt bricks of size 23 x 11.4 x 7.5 cm (9" x 4 1/2"x 3") 114 mm tk (B.P.)(using crushed stone sand) b. In Ground Floor/stilt floor
c. In First Floor
d. In Second Floor
e. In Third Floor
f. In Fourth Floor
11.2.1 : Brick work in C.M. 1:4 using chamber Burnt bricks of size 23 x 11.4 x 7.5 cm (9" x 4 1/2"x 3") 75 mm tk (B.P.)(using crushed stone sand) a. In Ground floor
b. In First floor
c. In Second floor
d. In Third floor
12.1.1 : Brick partition in C.M. 1:4 using country bricks of size 22 x11x5cm 50 mm thick (using crushed stone sand) a. In Ground floor
b. In First floor
c. In Second floor
d. In Third floor
14.1.I : Precast Cupboard slab 20mm tk. using standardised concrete mix M20 (Using crushed stone sand) a) In Ground Floor
b) In First Floor
c) In Second Floor
d) In Third Floor
14.1.II : Precast Cupboard slab 40mm tk. using standardised concrete mix M20 (Using crushed stone sand) a) In Foundation and basement
b) In Ground Floor
c) In First Floor
d) In Second Floor
e) In Third Floor
16.1.2 : Precast Jally Ventilator 50mm thick.Using standardised M20 grade concrete Mix withouty vibrating charges. (using crushed stone sand) a. In Ground Floor
b) In First Floor
c) In Second Floor
d) In Third Floor
e) In Fourth Floor
18.1 : Formwork using M.S.Sheet a.For Column footings,plinth beam,Grade beam,Raftbeam,Raft slab etc.,
b.Plain surfaces such as Roof slab,floorslab,Beams,lintels,lofts,sill slab,staircase,portico slab and other similar works
c.For Square and rectangular columns and small quantities
21.5.2 : Supply and fixing Solid UPVC door shutter with frame
21.6.1 : R.C.C.Door frames of size 100 x 75mm with one edge grooves size 't' x 20 mm M20 grade (with out vibrating charges) (using crushed stone sand) a. 900 x 2100mm
23.1 : TW styles & rails with 9mm thick BWR single leaf shutters with brass screws size of a. 900x2100 mm
23.2.1 : 4mm thick pin headed Glass panels with Aluminium beedings
22.3.3 : T.W. frame & T.W styles & rails with BWR double leaf shutters for Cup board/ward robes including two coat enamel paint & one coat primer.
26.1 : Flooring in C.C.1:5:10 (using crushed stone sand)
28.1 : Floor plastering in C.M. 1:4, 20 mm tk. (using crushed stone sand) Mixed with Super Plasticiser
29.8.1 : Glazed tiles using Grout (Tile Joint Filler) (using crushed stone sand)
29.9.1 :Floor ceramic tiles (Anti-skid) using Grout (Tile Joint Filler).(using crushed stone sand)
31.2.1 : Finshing the top of Terrace floor with one course of solar reflective Ceramic tiles without base concrete (using crushed stone sand)
33.1 : Plastering in C.M. 1:5, 12 mm tk. (using crushed stone sand) Mixed with Super Plasticiser
34.1: Plastering in C.M. 1:4, 12 mm tk.(using crushed stone sand) Mixed with Super Plasticiser
35.1: Spl. Ceiling plastering in C.M. 1:3,10 mm tk.(using crushed stone sand) Mixed with Super Plasticiser
36.1 : Cement mortar Border in C.M. 1:5, 12 mm tk (using crushed stone sand) including Super plasticizer a. 150 mm wide
b. 75 mm wide
c. 50 mm wide
38.6 : One coat white cement for new walls and other similar works.
38.7 : Plastic Emulsion PAINT including primer for outer
43.1 : Fabrication of Mild steel / RTS grills (without cement slurry) for all sizes of rods.
44.2 : Rain water harvesting using defunct borewell and providing perforated cover slab a). Providing pit
b) Augering 30cm dia
44.6 : PVC SWR 110 mm dia with ISI mark type- A for Rain water down fall pipe
50.3.1 : Supply and planting avenue trees (using crushed stone sand)
50.5.1 : Supplying. Fabricating and erection of M.S Scheme Name board (using crushed stone sand)
52.4 : 20mm dia PVC water supply ASTM pipe (fully consealed in walls)
53.5 : Wash Hand Basin of size 550 x 400 mm
54.1.1 : S & F of 15mm dia half turn CP long body tap
54.2.1 : S & F of 15mm dia half turn CP short body tap
56.3.1.1 : S&F of Indian Water Closet white glazed (Oriya type) of size 580 x 440mm with PVC SWR grade P' or "S' trap - G.F. (using crushed stone sand)
56.4.1.1 : S&F of Indian Water Closet white glazed (Oriya type) of size 580 x 440mm with PVC SWR grade P' or "S' trap - Other than G.F. (using crushed stone sand)
57.1.1.1 : S & F of E.W.C (White) 500mm with PVC SWR grade "P" or "S" TRAP (using crushed stone sand)
58.3 : PVC SWR pipe (Soil line) with ISI mark - type 'B'. a. 110 mm dia.
b. 75 mm dia.
58.4 : Supplying, Laying & Concealing the 50mm dia PVC ( SWR) pipe with ISI mark type - 'B' with relevant specials.
59.2.1 : Gully Trap using chamber burnt bricks of size 23x11.4x7.5cm (using crushed stone sand)
60.1 : PVC Nahani trap (4way/2way) (using crushed stone sand)
61.3 : UPVC Non Pressure pipe of SN8 SDR 34 (S 16.5) as per IS 15328/2003 a. 110 mm UPVC Non Pressure pipe
b. 160 mm UPVC Non Pressure pipe
62.1.1 : PVC Specials as per IS 10124/1982 Part II a. 110 mm dia PVC bend
b. 160 mm dia PVC bend
62.2.2 : PVC Equal Tee as per BIS 7834/1975 a. 110 mm dia PVC Equal tee
b. 160 mm dia PVC Equal tee
64.1 : Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990. a. Light point with ceiling rose
b. Light point without ceiling rose
c. Calling bell point with Buzzer/Calling bell
65.1 : Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for Fan point.
66.1 : Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for Staircase Light Point.
67.1 : Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for 5 amps 5 pin plug socket point @ Switch Board Itself.
68.2 : Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for 5 amps 5 pin plug socket point @ Convenient Places.
75.1 : Supply and delivery of 48" (1200 mm) Fan with ISI mark with Eletronic Dimmer
77.2.1 : S & F of 20 amps DP plug & Socket in sheet enclosure with 32 A DP MCB in flush wall with earth connection(For AC Plug)(Legrand (MDS)/Hager (L&T) equalivalent /superior variety
77.6 : Run of 2 Wires of 4 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990.
77.7 : Run of 2 Wires of 2.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990.
98.3.1 : TW panelled single door shutter (with brass fittings) a. 1000 x 2100mm. (Single leaf)
105.1 : Run off 4 x 4 Sq mm copper PVC insulated unsheathed single core cable for 3 phase EB service connection.
112.1 : S & F of Exhaust Fan 225mm dia
344.2 : S&F of Bevelled edge mirror 500 x 400 x 5.5mm
361.5.1 : Vitrified Tiles flooring (ivory) (using crushed stone sand)
367 : Providing wooden (melamine) polish for new wood
379.4.2.1 : S & F of Granite tile of size 2' x 1', 10mm Thick For kitchen arrangements (Jet black) a. In Ground floor
b. In First floor
c. In Second floor
d. In Third floor
383: S&F of Cuddapah sink 600 x 600 x 200mm
384: S&F of PVC flushing cistern 10 litre Capacity
448.2: Supply and fixing 32mm dia PVC Tee with end cap
799 : Two coat of OBD over one coat white cement for inner walls
826: Removing hard rock by wedging chiseling and Trimming to proper shape where blasting is prohibited
827: Providing 32mm dia drilling holes in hard rock for foundation and filling with cm 1:2 including, labour and michinery
A1: Supplying and fixing of LED blubs suitable for fixing it to pendent / bakelite battern holder of best approved variety a) 9 watts LED bulb
b) 12 watts LED bulb for bulk head fittings
A2 : Supplying and fixing of 25W LED street light with necessary fittings
A3: Supplying and fixing of 18W LED TUBE LIGHTS 4' long with necessary fittings and charges for assembling and fixing
A4 : Supplying and fixing of water tight Bulk head fittings with guard suitable for 12W LED lamp
A5: Supplying and fixing of 3 Nos. of 100 amps 500 volts grade porcelain fuse unit on suitable teakwood plank varnished to be fixed on the top of polw/Eb street pole with necessary clamps including cost of materials etc., all complete.
A6: Supplying and fixing of 3 Nos. of 200 amps 500 volts grade porcelain fuse unit on suitable teakwood plank varnished to be fixed on the top of pole/EB steet pole with necessary clamps including cost of materials etc., all complete.
ASR CONSTRUCTIONS
P SELLAPPAGOUNDER
ARUMUKA CONSTRUCTION
chendur construction company
GRG Builders
stage.html
html • 0.05 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_193360.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .