| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 1Schedule 'A' Part-I (Internal Electrification Works) | ||||||
| 2 | M&L for sub main wiring with 2.5 sqmm nominal cross sectional area, two single core, 1100 volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable with and including continuous earth wire of size 2.5 sqmm nominal cross sectional area, single core, 1100 volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable drawing into and including PVC casing caping of size 25 mm with all accessories and connected to common earth dolly and making good to the disturbed surfaces to match the existing paint of wall complete all as specified & directed by Engr-in-Charge.
Note:- Two run for neutral and phase and one run of continuous earth wire alongwith PVC casing caping shall be measured as one unit length. | 3,800 | RM | - | - | code1.02 |
| 3 | S&F in repairs industrial type SPN enclosure with a two pin and earth plug and socket complete with and including MCB, SP, AC, 230 volts of 20 amps, 'C' curve 10 KA breaking capacity and flush to wall including all cuttings & chases etc in wall and making good to the disturbed surfaces to match the existing complete. | 281 | Each | -1.25 | - | itemH1Code2 |
| 4 | M&L for sub main wiring with 6.0 sqmm nominal cross sectional area, two single core, 1100 volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable with and including continuous earth wire of size 6.0 sqmm nominal cross sectional area, single core, 1100 volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable drawing into and including PVC casing caping of size 25 mm with all accessories and connected to common earth dolly and making good to the disturbed surfaces to match the existing paint of wall complete all as specified & directed by Engr-in-Charge.
Note:- Two run for neutral and phase and one run of continuous earth wire alongwith PVC casing caping shall be measured as one unit length. | 1,300 | RM | -2.5 | - | code1.03 |
| 5 | Supply and fixing in repair single pole and neutral metalic enclosure double door distribution board for 12 way with 200 Amp , 240 volts rated busbar complete all as specified & directed by Engr-in-Charge. | 70 | Each | -3.75 | - | itemH1Code3 |
| 6 | S&F MCB, SP, AC, 230 volts of 06 to 32 amps capacity 'C' curve, 10 KA breaking capacity and making connections by using copper lugs in DB complete all as specified & directed by Engr-in-Charge. | 281 | Each | -5 | - | code1.04 |
| 7 | S&F sheet metal enclosure double door VTPN distribution board, AC, 440 volts, 04 ways with 400 amps rated bus bar and metal door with IP 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete and including provisions of MCCB all as specified and directed by Engr-in-Charge. | 20 | Each | -6.25 | - | itemH1Code4 |
| 8 | S&F MCCB, 63 amps, 04 pole, AC, 415 volts of 16 KA breaking capacity complete all as specified & directed by Engr-in-Charge. | 10 | Each | -7.5 | - | code1.05 |
| 9 | S&F MCCB, 100 amps, 04 pole, AC, 415 volts of 16 KA breaking capacity complete all as specified & directed by Engineer-in-Charge. | 10 | Each | -8.75 | - | itemH1Code5 |
| 10 | S&F MCB SPN 40 to 63 Amp rating 240 volts 10 KA breaking capacity, 'C' curve in DB complete with connections testng and commissioning complete all as specified & directed by Engineer-in-Charge. | 10 | Each | -10 | - | code1.06 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.