Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.4 LAccepted-Finance 6 RAILWAY STATION ROAD ONKAR INDUSTRIES GULAMALI PURA BAHRAICH UTTAR PRADESH 271801 | BAHRAICH | UTTAR PRADESH | 271801 | L1 | Accepted-Finance LOWEST BIDDER | |
| 2 | L2₹47.7 L+₹7.3 L (17.9%)Rejected-Finance B 56 LANE NO 4A SECTOR 7 VASHNAVI ENCLAVE CHANNI HIMAT JAMMU 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| Sl No | Description | Qty | Unit | MOHAN LAL AND SONS L1 | ANIKET TRADERS L2 |
|---|---|---|---|---|---|
| 1.00Schedule 'A' Part-I (Internal Electrification Works) | |||||
| 2.00 | M&L for sub main wiring with 2.5 sqmm nominal cross sectional area, two single core, 1100 volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable with and including continuous earth wire of size 2.5 sqmm nominal cross sectional area, single core, 1100 volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable drawing into and including PVC casing caping of size 25 mm with all accessories and connected to common earth dolly and making good to the disturbed surfaces to match the existing paint of wall complete all as specified & directed by Engr-in-Charge.
Note:- Two run for neutral and phase and one run of continuous earth wire alongwith PVC casing caping shall be measured as one unit length. | 3,800 | RM | 60 ₹2,28,000 Lowest | 190 ₹7,22,000 |
| 3.00 | S&F industrial type SPN enclosure with a two pin and earth plug and socket complete with and including MCB, SP, AC, 230 volts of 20 amps, 'C' curve 10 KA breaking capacity and flush to wall including all cuttings & chases etc in wall and making good to the disturbed surfaces to match the existing complete. | 281 | Each | 410 ₹1,15,210 Lowest | 900 ₹2,52,900 |
| 4.00 | M&L in repairs for sub main wiring with 6.0 sqmm nominal cross sectional area, two single core, 1100 volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable with and including continuous earth wire of size 6.0 sqmm nominal cross sectional area, single core, 1100 volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable drawing into and including PVC casing caping of size 25 mm/concealed conduit with all accessories and connected to common earth dolly and making good to the disturbed surfaces to match the existing paint of wall complete all as specified & directed by Engr-in-Charge.
Note:-
1. Two run for neutral and phase and one run of continuous earth wire alongwith PVC casing caping shall be measured as one unit length.
2. Paint to be done on plaster as making good, to be deemed included in quoted rate. | 1,300 | RM | 180 ₹2,34,000 Lowest | 230 ₹2,99,000 |
| 5.00 | Supply and fixing in repair single pole and neutral metalic enclosure double door distribution board for 12 way with 200 Amp , 240 volts rated busbar complete all as specified & directed by Engr-in-Charge. | 70 | Each | 700 ₹49,000 Lowest | 900 ₹63,000 |
| 6.00 | S&F in repair MCB, SP, AC, 230 volts of 06 to 32 amps capacity 'C' curve, 10 KA breaking capacity and making connections by using copper lugs in DB complete all as specified & directed by Engr-in-Charge. | 281 | Each | 90 ₹25,290 Lowest | 159 ₹44,679 |
| 7.00 | S&F sheet metal enclosure double door VTPN distribution board, AC, 440 volts, 04 ways with 400 amps rated bus bar and metal door with IP 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete and including provisions of MCCB and taking down old TPN DB all as specified and directed by Engr-in-Charge.
Note : Making good of disturbed surfaces with PCC and white paint is deemed included in quoted rate | 20 | Each | 1,800 ₹36,000 Lowest | 7,400 ₹1,48,000 |
| 8.00 | S&F in repairs MCCB, 63 amps, 04 pole, AC, 415 volts of 16 KA breaking capacity complete all as specified & directed by Engr-in-Charge. | 10 | Each | 2,500 ₹25,000 Lowest | 4,500 ₹45,000 |
| 9.00 | S&F in repairs MCCB, 100 amps, 04 pole, AC, 415 volts of 16 KA breaking capacity complete all as specified & directed by Engineer-in-Charge. | 10 | Each | 2,500 ₹25,000 Lowest | 4,500 ₹45,000 |
| 10.00 | S&F in repairs MCB SPN 40 to 63 Amp rating 240 volts 10 KA breaking capacity, 'C' curve in DB complete with connections testng and commissioning complete all as specified & directed by Engineer-in-Charge. | 10 | Each | 250 ₹2,500 Lowest | 800 ₹8,000 |
Tender Value
₹43.6 L
EMD Value
₹87,200
Closing Date
30 Jul 2026, 6:00 pmClosed
HQ CWE AF Jammu
HQ CWE AF Jammu Air Force Station Jammu
CA NO CWEAFJ-17/2026-27 PROVN OF AC POINT AND 15 AMP SOCKET ALONGWITH ASSOCIATED WORKS IN CERTAIN OMQ/SMQS AT AIR FORCE STATION UDHAMPUR UNDER GE (AF) UDHAMPUR
2026_MES_774381_1
CA NO CWEAFJ-17/2026-27
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
UDHAMPUR
As per NIT and Tender document
9 documents required · 9 mandatory
₹500
GE (AF) Udhampur
₹87,200
Yes
25 Sept 2026
24 Jun 2026
1 Aug 2026
24 Jun 2026
30 Jul 2026
11 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Schedule 'A' Part-I (Internal Electrification Works) | |||||
| 2 | M&L for sub main wiring with 2.5 sqmm nominal cross sectional area, two single core, 1100 volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable with and including continuous earth wire of size 2.5 sqmm nominal cross sectional area, single core, 1100 volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable drawing into and including PVC casing caping of size 25 mm with all accessories and connected to common earth dolly and making good to the disturbed surfaces to match the existing paint of wall complete all as specified & directed by Engr-in-Charge.
Note:- Two run for neutral and phase and one run of continuous earth wire alongwith PVC casing caping shall be measured as one unit length. | 3,800 | RM | - | - |
| 3 | S&F in repairs industrial type SPN enclosure with a two pin and earth plug and socket complete with and including MCB, SP, AC, 230 volts of 20 amps, 'C' curve 10 KA breaking capacity and flush to wall including all cuttings & chases etc in wall and making good to the disturbed surfaces to match the existing complete. | 281 | Each | -1.25 | - |
| 4 | M&L for sub main wiring with 6.0 sqmm nominal cross sectional area, two single core, 1100 volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable with and including continuous earth wire of size 6.0 sqmm nominal cross sectional area, single core, 1100 volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable drawing into and including PVC casing caping of size 25 mm with all accessories and connected to common earth dolly and making good to the disturbed surfaces to match the existing paint of wall complete all as specified & directed by Engr-in-Charge.
Note:- Two run for neutral and phase and one run of continuous earth wire alongwith PVC casing caping shall be measured as one unit length. | 1,300 | RM | -2.5 | - |
| 5 | Supply and fixing in repair single pole and neutral metalic enclosure double door distribution board for 12 way with 200 Amp , 240 volts rated busbar complete all as specified & directed by Engr-in-Charge. | 70 | Each | -3.75 | - |
| 6 | S&F MCB, SP, AC, 230 volts of 06 to 32 amps capacity 'C' curve, 10 KA breaking capacity and making connections by using copper lugs in DB complete all as specified & directed by Engr-in-Charge. | 281 | Each | -5 | - |
| 7 | S&F sheet metal enclosure double door VTPN distribution board, AC, 440 volts, 04 ways with 400 amps rated bus bar and metal door with IP 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete and including provisions of MCCB all as specified and directed by Engr-in-Charge. | 20 | Each | -6.25 | - |
| 8 | S&F MCCB, 63 amps, 04 pole, AC, 415 volts of 16 KA breaking capacity complete all as specified & directed by Engr-in-Charge. | 10 | Each | -7.5 | - |
| 9 | S&F MCCB, 100 amps, 04 pole, AC, 415 volts of 16 KA breaking capacity complete all as specified & directed by Engineer-in-Charge. | 10 | Each | -8.75 | - |
| 10 | S&F MCB SPN 40 to 63 Amp rating 240 volts 10 KA breaking capacity, 'C' curve in DB complete with connections testng and commissioning complete all as specified & directed by Engineer-in-Charge. | 10 | Each | -10 | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.36 MB
BOQ_867127.xls
BOQ • 0.80 MB
17TENDERDOC.pdf
Tender Documents • 1.26 MB
2BOQANDTENDERDOCCORR17.pdf
PDF • 0.34 MB
2DATECORR17.pdf
PDF • 0.13 MB
AMDT1CAT17.pdf
PDF • 0.13 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .