| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1 CrAccepted-AOC ACHYUT IMPERIA B 208 RADHANAGAR VIP ROAD GHY 22 DIST KAMRUP M ASSAM | GUWAHATI | KAMRUP | ASSAM | ₹1 Cr | L1 | Accepted-AOC Awarded |
| 2 | L2₹1.1 CrRejected-AOC GHORAMAR GUWAHATI ASSAM | ₹1.1 Cr | L2 | Rejected-AOC Not Awarded |
| Sl No | Description | Qty | Unit | Biren Deka L2 | H.P. Enterprises L1 |
|---|---|---|---|---|---|
| 1.00Murong Okum, Japorigog | |||||
| 2.00VRF / VRV SYSTEM HIGH SIDE Supply of Outdoor Units (Cooling only) suitable for VRF/VRV System The system shall comprise of Outdoor Units with Air-cooled condenser selected to operate at run capacity at ambient temp. of 35°C. high pressure Rotarv | Scroll Compressors with hermetic motor, assembled and wired in a single package complete. starting controls, safety controls, operating Controls and with full feature microcomputer based controller with real time clock and programming 7 |diagnoSIS tacility. One / All Compressors shall be inverter type based on manufacturer's technology & shall work for year round performance for the heating OR Cooling requirements. | |||||
| 3.00The unit is to be given a complete factory operating and control sequence test under load conditions with fluid hooked up, and is to be shipped with full operating charge of refrigerant and oil. Air-cooled Condensor, refrigeration-piping controls, first charge of refrigerant etc. | |||||
| 4.00 | The Refrigerant used shall be any CFC free gas R410A refrigerant OR any other variant of CFC free refrigerant gas. The Outdoor units shall be complete as per technical specifications The Indoor and Outdoor units shall be complete as per technical specifications & also provide full
capacity performance at 35 deg.C outdoor ambient and for indoor conditions of 23 deg.C The VRF system shal be selected with higher EER requirements as per ANSIWASHRAE/IESNA
Standard 90.1-2010 for VRV systems. Outdoor units suitable for following capacities: 1.1 36 HP VRF ODU (Cooling Only) | 2 | nos | 8,00,599 ₹16.0 L | 8,00,000 ₹16 L |
| 5.00INDOOR UNITS Supply of Ductable, Cassette & Hi-Wall Type Units as follows in VRF /VRV System (Heat Pump type for heating/cooling requirements)suitable for functioning with above outer units. Indoor Fan coil unit consisting of 3/4 row-cooling coil blower with motor, filters, drain pan & casing The indoor unit shall be capable to accept complete with all necessary controls including air and |refrigerant temperature sensors and electronic expansion valves thus giving individual, variable |refrigerant flow. Indoor units for cabin / meeting rooms shall be capable to accept the signal from temperature sensor. The electronic expansion valve shall be controlled by the fuzzy logic' microprocessor control system via a control board within the indoor unit that includes a unit address recognition system. Indoor Units to trip incase of fire signal. All Indoor units shall include the standard condensate pump kit (for Cassette's only) as supplied by the manufacturer. For all other units drain pump will be a separate item. The indoor unit shall be suitable for a power supply of 24OV/ 1 phase/ 5OHz OR 415V / 3 phase 50Hz. The indoor units shall be complete as per Technical Specifications and requirements as specified below. The units shall be selected to operate at specified indoor units. | |||||
| 6.00 | 2.1 FLOOR MOUNTED Type A.H.U Units with mixing box 12000 CEM /30 TR/ 36.0 HP | 2 | nos | 6,01,350 ₹12.0 L | 5,75,000 ₹11.5 L |
| 7.00 | 30 TR/36.0 HP ELECTRONICS EXPANTION VALVE KIT | 2 | Nos | 50,007 ₹1.0 L | 55,000 ₹1.1 L |
| 8.00 | CONTROLL BOX | 4 | Nos | 10,761 ₹43,044 | 10,000 ₹40,000 |
| 9.00 | VRV Accessories Refnet Joints | 2 | sets | 5,317 ₹10,634 | 4,800 ₹9,600 |
| 10.00 | Multikit | 2 | sets | 5,824 ₹11,648 | 4,600 ₹9,200 |
Tender Value
₹1 Cr
EMD Value
₹2 L
Closing Date
23 Jan 2026, 3:00 pmClosed
Managing Director
Office of The Managing Director, APTDC Ltd., Ganeshguri, Ghy, 5
Installation of AC, Light Sound System at Murong Okum at Japorigog under Dispur LAC in Kamrup (M) District.
2026_WPTBC_49969_1
PTDC/Engg/2024-25/461
Open Tender
Civil Works
365 days
Japorigog, Kamrup (M)
Please refer to tender document
3 documents required · 3 mandatory
₹2,000
₹2 L
Yes
Managing Director, APTDC Ltd., Ganeshguri, Ghy, 5
10 Mar 2026
6 Jan 2026
23 Jan 2026
6 Jan 2026
23 Jan 2026
7 Jan 2026
12 Jan 2026
Murong Okum, Japorigog
The unit is to be given a complete factory operating and control sequence test under load conditions with fluid hooked up, and is to be shipped with full operating charge of refrigerant and oil. Air-cooled Condensor, refrigeration-piping controls, first charge of refrigerant etc.
2.1 FLOOR MOUNTED Type A.H.U Units with mixing box 12000 CEM /30 TR/ 36.0 HP
30 TR/36.0 HP ELECTRONICS EXPANTION VALVE KIT
CONTROLL BOX
VRV Accessories Refnet Joints
Multikit
Wireless remote Controllers for cassate,hi wall units, FCU/ Ductable
Lifting Shifting, Erection, lnstallation, Testing and Commissioning of Out Door Units suitable for VRF VRV System & including refrigerant gas & oil upto commissioning & warranty period for all above Indoor & Outdoor Systems - Pressure Testing, Nitrogen flushing, gas charging (R407C/R410A), testing & commissiong of the air-conditioning system(We have not consider the coasts of MS stand. Duct cowl piece for the ODU installation) 1.1 36 HP VRF ODU (Cooling Only)
Lifting Shifting. Erection, Installation, Testing and Commissioning of Indoor Units suitable for V Ceiling Suspended/ FLOOR MOUNTED Type A.H.U Units 30 TR /36 0 HP
30TR/ 36.0 HP ELECTRONICS EXPANTION VALVE KIT
CONTROLL BOX
Refrigerant piping Hard/Soft Copper refrigerant piping of required sizes for pair of gas (suction) & liquid, with 25 mm / 19 mm closed Cell Insulation material with confirming to class O/60 g/m3 density for Wrapping the copper pipe lines. The piping system must be suppor Pressure Testing of VRF piping shall be as per VRF Manufacturer's requirements. 12.7mm
Drain piping in CPVC with all fittings, supports and clamps with insulation upto 50 mm dia. including drilling hole in wall chipping wall etc to conceal and to route the drain pipe. CPVC pipe shall be as per class 1 SDR11/13.5 confirming to IS 15778:2007. (Drain piping for All VRF & DX AC system) 32 mm dia
42 mm dia
2C x 1.0 mm2 Copper Cable for Communication Cable between VRV Indoor Unit & Outdoor Units with 25 mm PVC condit pipe
Nitrogen flushing of entire system
Commissioning with extra R410A refrigerant gas charge
Sitc of controll cabling for A,H,U, EEV KIT
SITC OF site fabricated GSS Duct as per aproved drawing (24SWG)
SITC OF site fabricated GSS Duct as per aproved drawing (22SWG)
SITC of thermal insulation with 19 mm thick class "O" nitral rubber sheet
SITC of Acoustic insulation with open cell nitrile rubber sheet for duct and ahu room
SITC of GI. volum controll damper for controlling the volume of air
SITC of extruded powder coated linnear grill
SITC of M.S. /G.I. collar damper for air balancing
SITC extruded aluminium powder coated 3 slotted diffuser
SITC AHU Starter panel
SITC of canvas connection
Sound and Lighting System Supply, Installation, Testing and Commissioning of 15" Two-Way Loudspeaker System. Frequency Range (10dB)48 Hz- 19 kHz Frequency Response (+3 dB) 61 Hz - 16 kHz Coverage Pattern 90° x 50° nominal 1 System Sensitivity 100 dB SPL (1w@1m) Power Rating, Pink Noise 600 W/ 1200 W / 2400W(Continuous/Program/Peak) Maximum SPL (1m)134 dB SPL peak Nominal Impedance 4 ohms (Make:- JBL)
Supply, lnstallation, Testing and Commissioning of Two-channel, 1200W @ 40 Power Amplifier. Sensitivity 1.4V Rated Power Output (per channel) 1600W 2Ω,1200W 4Ω,650W 8Ω Signal to Noise Ratio (below rated 1 kHz power at 8 ohms) 100 db (A-weighted) |THD < 0.5% Frequency Response (at 1W, 20 Hz- 20 kHz) +0 dB, -1dB Crosstalk (below rated power) 20 Hz to 1 kHz >70 dB (Make:- Crown)
Supply, Installation, Testing and Commissioning of 18" Subwoofer. Frequency Range 35 Hz -250 Hz |Frequency Response 52 Hz - 120 Hz |System Sensitivity 95 dB SPL (1w@1m) Power Rating, Pink Noise 800 W/ 1600 W/3200 W(Continuous/Program/Peak) Maximum SPL (1m) 130 dB SPL peak Nominal Impedance 8 ohms (Make:- JBL) |
Supply, Installation, Testing and Commissioning of Two-channel, 2100W@ 40 Power Amplifier. Sensitivity 1.4V Rated Power Output (per channel) 3000w 2Ω, 2100w 4Ω, 1200W 8Ω Signal to Noise Ratio (below rated 1 kHz power at 8 ohms) 103 dB (A-weighted) THD < 0.5% Frequency Response (at 1W, 20 Hz- 20 kHz) +0 dB, -1 dB Crosstalk (below rated power) 20 Hz to 1 kHz >70 dB (Make:-Crown)
Supply, Installation, Testing and Commissioning of 12-inch Powered Monitor Speaker. Max SPL:- 127dB @1m/4Pi, Freg Range -10:- 50Hz -20kHz, Freq Range -3 |60Hz- 20kHz, Hor Dispersion:- 100°, Vert Dispersion:- 60°, Power Rating:- 1300W peak/ 650 RMS. (Make:- JBL)
Supply, Installation, Testing and Commissioning of 32-channel Mixer with EffectS and Console. 24 Mic Inputs with 48V Phantom Power and HPF per Channel, 32 Line input (24 mono and 4 stereo), 6 AUX Sends + 2 FX Sends. 4 GROUP Buses + ST Bus, 2 matrix out, 1 mono out. (Make:- Yamaha/ Behringer)
Supply, Installation, Testing and Commissioning of Wired Dynamic Microphone.
Sypply, Installation, Testing and Commissioning of Instrumental Microphone.
Supply, Installation, Testing and Commissioning of Wireless Handheld Microphone.
Supply, Installation, Testing and Commissioning of Wireless Headworn Microphone 9 Set. (Make:- AKG/ Audio Technica)
Supply, Installation, Testing and Commissioning of Podium Gooseneck Microphone with base
Supply and Installation of Audio Connectors and Accessories (Make:- Gotham/ Amphenol/ Neutrik)
Supply and Laying of 2 Core 2.5 Sqmm High Flexible Audio Speaker Cable (Make:- Gotham/ Belden/ Klotz)
Supply and Laying of Audio Signal/ Microphone Cable (Make:- Gotham/ Belden/ Klotz)
Repairing Replacerment of HF Diaphragm of Existing Monitor Speakers and Repairing of the same in all aspects.
Supply, Installation, Testing and Commissioning of Par-64, 1000w, 240volt Lamp (Philips/ Osram)
Supply, Installation, Testing and Commissioning of LED Blinder 400w Supply of LED blinder Specification Model:4 Eyes Blinder COB Matrix blinder audience cob LED light, 4* 100W 3200K party event equipment 1.Light Source : 4 pcs, 100/100W warm white or cool white or cool white + warm white 2in 1 or white + yellow 2 in, 1.Voltage: AC90V -245V 2 Frequency: 50-60Hz Power Consumption :450W Light Color :White or warm White LED Control: Individual Controllable Lifetime:60,000 hours |DMX Channel : 6/12/2CH, Color Temp: 250OK /3200K / 6500K Warm White 5600K - 6400K Cool White: 2800K -3200K, Dimmer :0100% Linear |Adjustable Beam Angle:38 Degree Working Termperature: -30°C"50°C,
Supply of Light Controller Computer Light Controller, Product Model:Mini Pearl Voltage 100 to 240 V Frequency 50/60 Hz Mating number of Fixtures 96 The Number of Scenes That Can be Saved 60 The Number of Scenes That Can Run Simultaneously 10 The Total Number of Steps in a Multi Step Scenario 600 Scene Time Control Fade In, Fade Out LTP Sliding Graphics Can be Stored for Each Scene 5 Fader Scenes/Dimming Size 485 x 420 x 105 cm (Make:- Zero88/ Avolite/ PLS)
Supply and Installation of Lighting Fixtures and Accessories
Supply and Installation of 6KVA Online UPS with SMF Batteries and Rack. T(Make:- Delta/ Vertive/ APC)
Miscellenious work Supplimaentary Item/SOR-21.10-Supplying, Fabrication, Erection , Testing commissioning of vermin and dust proof (IP-43 protection)totally enclosed cubical type compartmental floor mounting panel board of size 1950mm x 1000mm x 500mm made of 16 SWG1.66mthick C.R. sheet and 300mm x 30mmx5mm MS Angle having 4 nos. Legs at the bottom and C.R. sheet roofing on the top complete painting with 2 coats of Red Oxide metal primer and 2 coats of Enamel paint. The panel board is to be erected in 1 :3:6 PCC foundation including excavation Complete neatly Wiring done, with the provision for the following Electrical Accessories. Provision for 250A 4Pole MCCB INCOMING. Provision for 10 nos FP/TPN MCCB 1. i) 30mm X 5mm 4 strip copper Bus - Bar 1.20 M length each ii) 20mm X 3mm 4 strip copper Bus-Bar 0.5M each 6sets 2. Digital 3 Phase Voltmeter Accuracy class 0.5 - 1 no 3. Digital 3 Phase Ammeter Accuracy class 0.5 - 1 no 4. Pilot Lamp with integral ckt LED 110- 230 V (Red, Yellow,& Blue - 3 no 6. 2 A Slide fuse unit - 3nos
Supplying, Installation, testing and commissioning of DG Sets, AMF Panel, Bus ducting/ cables from DG sets to essential panel, DG set enclosure room sound insulation/ventilation/smoke exhaust as required, earthing of DG set system, control cabling, fuel tank/piping, DG set exhaust piping/exhaust chimney as per cpcb norms, civil works connected with DG sets including DG set as required
Cost for Repairing and Renovation of Kitchen
12.45 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :
12.45.1 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks)
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.42 MB
SBD.pdf
Tender Documents • 1.03 MB
BOQ_79468.xls
BOQ • 0.42 MB
Download all tender documents and submit your bid