| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹66.7 LAccepted-AOC A 12 SECTOR 59 NOIDA GAUTAM BUDDHA NAGAR UTTAR PRADESH 201301 | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201301 | L1 | Accepted-AOC L1 | |
| 2 | L2₹77.7 L+₹11.0 L (16.5%)Rejected-Finance 100 FEET ROAD AHMEDABAD CITY GUJARAT 380059 INDIA | AHMADABAD | GUJARAT | 380059 | L2 | Rejected-Finance L2 |
| Sl No | Description | Qty | Unit | Neptune Automatic Pvt. Ltd. L1 | Swaraj Secutech Pvt Ltd L2 |
|---|---|---|---|---|---|
| 1.00 | Design, Supply, Installation, Testing and Commissioning of 05 No's K4/M30 or higher - Tested and crash rated (in either directions) “Electro – Hydraulic Retractable bollards (for approx. 7 Mtr wide) in complete as a system” along with all related connections for main approach road / operational vehicle gate comprising bollards of 900 mm height(Minimum) and minimum of 220 mm dia made up of High tensile carbon steel cylinder along with all other accessories like provision of Manual operation during power off, safety interlock detector, Self priming sump pump for draining water, Hydraulic Power Pack/Unit with accumulator, “control and logic circuit” in a weather proof enclosure with provision for integrating with external Access control system like loop detectors, crash pads etc. if any, Operational alerts /System alerts with Blinking LED, Audio signal during Operation, including necessary civil foundation work, necessary excavation, providing necessary control cables, its connections & inter connections etc. complete as per site requirement, as per the technical specifications, as per site condition and as per direction of EIC. (Crash rating test certificate from accredited authority shall be submitted by bidder) | 1 | Job | 16,80,000 ₹16,80,000 Lowest | 17,87,500 ₹17,87,500 |
| 2.00 | Design, Supply, Installation, Testing and Commissioning of 04 No's K4/M30 or higher - Tested and crash rated (in either directions) “Electro – Hydraulic Retractable bollards (For approxm 6 Mtr wide) in complete as a system” along with all related connections for main approach road / operational vehicle gate comprising bollards of 900mm height(Minimum) and minimum of 220 mm dia made up of High tensile carbon steel cylinder along with all other accessories like provision of Manual operation during power off, safety interlock detector, Self priming sump pump for draining water, Hydraulic Power Pack/Unit with accumulator, "control and logic circuit ” in a weather proof enclosure with provision for integrating with external Access control system like loop detectors, crash pads etc. if any, with an Axle load bearing capacity of Road/Base plate of 20 tons (Minimum), Operational alerts /System alerts with Blinking LED, Audio signal during Operation, including civil foundation work, necessary excavation, providing necessary control cables, its connections & inter connections etc. complete as per site requirement, as per the technical specifications, as per site condition and as per direction of EIC. (Crash rating test certificate from accredited authority shall be submitted by bidder) | 1 | Job | 13,44,000 ₹13,44,000 Lowest | 14,30,000 ₹14,30,000 |
| 3.00 | Design, Supply, Installation, Testing and Commissioning of k4 Crash Rated Boom Barrier for the Road length of 7 mtr as per Technical specifications including civil works, necessary excavation and providing necessary control cables and its connections & inter connections etc. complete as per site requirement, as per the technical specifications, as per site condition and as per direction of EIC. (Crash rating test certificate from accredited authority shall be submitted by bidder) | 1 | Job | 4,49,000 ₹4,49,000 Lowest | 6,45,000 ₹6,45,000 |
| 4.00 | Design, Supply, Installation, Testing and Commissioning of k4 Crash Rated Boom Barrier for the Road length of 6 mtr as per Technical specifications including civil works, necessary excavation and providing necessary control cables and its connections & inter connections etc. complete as per site requirement, as per the technical specifications, as per site condition and as per direction of EIC. (Crash rating test certificate from accredited authority shall be submitted by bidder) | 1 | Job | 4,49,000 ₹4,49,000 Lowest | 6,25,000 ₹6,25,000 |
| 5.00 | Supply of following size cables of grade 1.1 KV, XLPE insulated, PVC sheathed, armoured Aluminium conductor conforming to IS 7098 (Part 1) amended upto date.
4Cx35 Sq.mm | 120 | Mtr. | 392 ₹47,040 Lowest | 450 ₹54,000 |
| 6.00 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required as per site condition and as per direction of EIC .
Up to 35 Sq.mm | 100 | Mtr. | 140 ₹14,000 Lowest | 550 ₹55,000 |
| 7.00 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required as per site condition and as per direction of EIC .
4C X 35 Sq.mm | 4 | Sets | 1,680 ₹6,720 Lowest | 2,500 ₹10,000 |
| 8.00 | Supplying and fixing 4P,32A MCB in the IP 65 rating PVC MCB enclosure box outdoor type (suitable for 02 no's 4P MCBs) on surface or supporting MS supporting legs etc. complete as required including civil works etc. as required as per site condition and as per direction of EIC . | 2 | Job | 5,390 ₹10,780 Lowest | 28,500 ₹57,000 |
| 9.00 | Providing and fixing of 6 SWG dia G.I. wire on surface or in recess for loop earthing along the cable etc,. Complete as required. | 100 | Mtr. | 107 ₹10,700 | 85 ₹8,500 Lowest |
| 10.00All-inclusive comprehensive maintenance contract(AICMC) for item no-01, item no-02, item no-03 & item no-04 of Hydraulic bollards and 06mtr & 07mtr length Boom barrier after completion of defect liability period of 02 years including all spares, replacement of all defective parts and consumables, carrying out monthly routine maintenance checks, preventive maintenance as per OEM recommendations and breakdown maintenance as & when required, as Special Conditions of the contact, as per site conditions and as per direction of EIC. | |||||
Tender Value
₹1.2 Cr
EMD Value
₹3.5 L
Closing Date
6 Apr 2026, 6:00 pmClosed
Asst. General Manager (Engg.- Elect.)
O/o of DGM (EE), Asst. General Manager (Engg - Elect), Electrical Engineering Wing, (Bid Manager), Airports Authority of India, B.P.I Airport, Bhubaneswar - 751020
SITC of Crash rated Bollards and Boom Barriers including AICMC for 08 years at B.P.I. Airport, Bhubaneswar.
2026_AAI_270357_1
AAI/BS/ENGG(E)/NIT-22/2025-26
Open Tender
Electrical Works
Works
180 days
BPI Airport, Bhubaneswar.
Please refer Tender documents.
13 documents required · 13 mandatory
₹1,180
₹3.5 L
BPI Airport, Bhubaneswar.
12 Oct 2026
14 Mar 2026
7 Apr 2026
15 Mar 2026
6 Apr 2026
15 Mar 2026
15 Mar 2026 - 23 Mar 2026
18 Mar 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Design, Supply, Installation, Testing and Commissioning of 05 No's K4/M30 or higher - Tested and crash rated (in either directions) “Electro – Hydraulic Retractable bollards (for approx. 7 Mtr wide) in complete as a system” along with all related connections for main approach road / operational vehicle gate comprising bollards of 900 mm height(Minimum) and minimum of 220 mm dia made up of High tensile carbon steel cylinder along with all other accessories like provision of Manual operation during power off, safety interlock detector, Self priming sump pump for draining water, Hydraulic Power Pack/Unit with accumulator, “control and logic circuit” in a weather proof enclosure with provision for integrating with external Access control system like loop detectors, crash pads etc. if any, Operational alerts /System alerts with Blinking LED, Audio signal during Operation, including necessary civil foundation work, necessary excavation, providing necessary control cables, its connections & inter connections etc. complete as per site requirement, as per the technical specifications, as per site condition and as per direction of EIC. (Crash rating test certificate from accredited authority shall be submitted by bidder) | 1 | Job | - | - |
| 2 | Design, Supply, Installation, Testing and Commissioning of 04 No's K4/M30 or higher - Tested and crash rated (in either directions) “Electro – Hydraulic Retractable bollards (For approxm 6 Mtr wide) in complete as a system” along with all related connections for main approach road / operational vehicle gate comprising bollards of 900mm height(Minimum) and minimum of 220 mm dia made up of High tensile carbon steel cylinder along with all other accessories like provision of Manual operation during power off, safety interlock detector, Self priming sump pump for draining water, Hydraulic Power Pack/Unit with accumulator, "control and logic circuit ” in a weather proof enclosure with provision for integrating with external Access control system like loop detectors, crash pads etc. if any, with an Axle load bearing capacity of Road/Base plate of 20 tons (Minimum), Operational alerts /System alerts with Blinking LED, Audio signal during Operation, including civil foundation work, necessary excavation, providing necessary control cables, its connections & inter connections etc. complete as per site requirement, as per the technical specifications, as per site condition and as per direction of EIC. (Crash rating test certificate from accredited authority shall be submitted by bidder) | 1 | Job | - | - |
| 3 | Design, Supply, Installation, Testing and Commissioning of k4 Crash Rated Boom Barrier for the Road length of 7 mtr as per Technical specifications including civil works, necessary excavation and providing necessary control cables and its connections & inter connections etc. complete as per site requirement, as per the technical specifications, as per site condition and as per direction of EIC. (Crash rating test certificate from accredited authority shall be submitted by bidder) | 1 | Job | - | - |
| 4 | Design, Supply, Installation, Testing and Commissioning of k4 Crash Rated Boom Barrier for the Road length of 6 mtr as per Technical specifications including civil works, necessary excavation and providing necessary control cables and its connections & inter connections etc. complete as per site requirement, as per the technical specifications, as per site condition and as per direction of EIC. (Crash rating test certificate from accredited authority shall be submitted by bidder) | 1 | Job | - | - |
| 5 | Supply of following size cables of grade 1.1 KV, XLPE insulated, PVC sheathed, armoured Aluminium conductor conforming to IS 7098 (Part 1) amended upto date.
4Cx35 Sq.mm | 120 | Mtr. | - | - |
| 6 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required as per site condition and as per direction of EIC .
Up to 35 Sq.mm | 100 | Mtr. | - | - |
| 7 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required as per site condition and as per direction of EIC .
4C X 35 Sq.mm | 4 | Sets | - | - |
| 8 | Supplying and fixing 4P,32A MCB in the IP 65 rating PVC MCB enclosure box outdoor type (suitable for 02 no's 4P MCBs) on surface or supporting MS supporting legs etc. complete as required including civil works etc. as required as per site condition and as per direction of EIC . | 2 | Job | - | - |
| 9 | Providing and fixing of 6 SWG dia G.I. wire on surface or in recess for loop earthing along the cable etc,. Complete as required. | 100 | Mtr. | - | - |
| 10All-inclusive comprehensive maintenance contract(AICMC) for item no-01, item no-02, item no-03 & item no-04 of Hydraulic bollards and 06mtr & 07mtr length Boom barrier after completion of defect liability period of 02 years including all spares, replacement of all defective parts and consumables, carrying out monthly routine maintenance checks, preventive maintenance as per OEM recommendations and breakdown maintenance as & when required, as Special Conditions of the contact, as per site conditions and as per direction of EIC. | |||||
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.51 MB
DNIT.pdf
Tender Documents • 10.02 MB
BOQ_315974.xls
BOQ • 0.40 MB
CorigendumIBollard.pdf
PDF • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .