| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.8 LAccepted-AOC | L1 | Accepted-AOC Lowest rate quoted | |
| 2 | L2₹40.1 L+₹2.6 L (6.87%)Rejected-Finance | L2 | Rejected-Finance Higher rate quoted | |
| 3 | L3₹40.3 L+₹2.8 L (7.35%)Rejected-Finance PO PS BUD BUD DISTT PURBA BURDWAN PIN 713403 | BUD BUD | PURBA BURDWAN | WEST BENGAL | 713403 | L3 | Rejected-Finance Higher rate quoted | |
| 4 | L4₹46.9 L+₹9.3 L (24.8%)Rejected-Finance | L4 | Rejected-Finance Higher rate quoted |
Tender Value
₹46.1 L
EMD Value
₹92,300
Closing Date
23 Mar 2022, 6:00 pmClosed
GE PANAGARH
GARRISON ENGINEER PANAGARH, MILITARY ENGINEER SERVICES, PO-PANAGARH, DIST-BURDWAN, WEST BENGAL, PIN-713420
All as per BOQ
2022_MES_510483_1
8400-748/E8
Open Tender
Civil Works
Works
180 days
PANAGARH
Class D, Cat a (i)
6 documents required · 6 mandatory
₹500
GE PANAGARH
₹92,300
Yes
27 Apr 2022
25 Feb 2022
25 Mar 2022
25 Feb 2022
23 Mar 2022
10 Mar 2022
Amount
Dismantling Asbestos cement (corrugated,semi corrugated, etc.) sheets in roof coverings with ridges etc complete all as specified and directed.
Dismantling old Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
S&F 0.50 mm thick pre- painted galvalume aluminium zinc coating GI based corrugeted steel sheet of any colour as approved of 550 Mpa tensile strength as in roof covering / cladding to wall fixed with self tapping screws complete specified and directed.
M&L for Pre-painted galvalume aluminium zinc coating GI based plain sheet 0.50 mm thick any colour having tensile strength of 550 Mpa as in ridges, hips valley gutter etc fixed with self tapping screws complete and as specified and directed.
Taking down chowkats or frames with shutter without taking off shutter from the frame n exc 1.5 Sqm each incl cutting holes for taking out hold fast or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt.) all as specified and directed By Engr-in-charge.
Taking down chowkats or frames with shutter without taking off shutter from the frame exc 1.5 Sqm & n. exe 4 Sqm each incl cutting holes for taking out hold fast or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt.) all as specified and directed By Engr-in-charge.
S&F 2nd class hard wood plain solid straight chowkhat and frames wrought framed rebated on the solid rounded or chamfered put together with glue pinned at joint complete all as specified and directed.
S&F 30 mm thick Fiberglass Reinforced Plastic (F.R.P.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF)/Polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of F.R.P. laminate conforming to table 3 of IS: 14856 complete all as specified by the manufacturer and as per directions of Engineer- in-charge.
S&F anodised powder coated aluminium frame for doors,windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified.
S&F anodised powder coated aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified
Hacking Out Old Broken Glass (any thickness, size, quality or description) from Wooden Frames, Glazed with Putty or fixed with Beads, complete all as specified and as directed.
S&F 5.5 mm thick sheet glass, ordinary quality and glazing with oil putty in square n.exc 0.5 Sqm each panes complete all as specified.
S&F prelaminated particle board 18/19 mm thick, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work complete all as specified and directed
Demolition of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level complete all as specified and directed.
M&L for hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for Cement concrete 75 mm thick type B- 2, 1:2:4 finishing cement concrete surface even and smooth (using 40mm graded stone aggregate) using extra cement complete all as specified and directed.
M&L for PCC 1:3:6 Type C1 (using 20 mm graded stone aggregates) as in plinth protection finished even and smooth without using extra cement and the like including weathering, slightly rounded or chamfered angles and throating, as directed .
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, mounds, mitred/stopped end etc complete all as specified and directed.
Demolition of brick work built in cement mortar or cement lime mortar incl all quoins, arches pillars etc and removing unserviceable material exc 100 mtr complete all as specified and directed.
M&L for brick work with FLY ASH ‘ B’ bricks straight or curved on plan exc 6 m mean radius build in CM (1:4) complete all as specified as directed.
M&L for brick work with FLY ASH ‘ B’ bricks as in half brick thick wall straight or curved on plan exc 6 m mean radius build in CM (1:4) all as specified as directed.
Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store yard and rubbish off the premises as directed.
M&L for non-skid ceramic, straight cut/joint free, 7-8 mm thick colored tiles, area of each tile exceeding 0.11 Sq.m but not exceeding 0.18 Sq.m, in floors etc. over and including 15 mm thick cement mortar (1:4) screed, set and jointed with grey cement slurry & pointed with grout of matching shade, , complete all as specified and directed. Note: Design, shade and pattern of fixing of tiles shall be as directed and approved by GE.
M&L for rendering 15 mm thick in cement mortar (1:4) on other than fair face of brick work surfaces finished even and smooth with out using extra cement all as specified.
M&L for Glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick over 10 mm plaster in CM (1:3) set and jointed in neat cement slurry and pointed in white or colour cement to match all as specified as directed. Note : Design, shade and pattern of fixing of tiles shall be as directed by Engr-in-charge.
Supply only Integral Water proofing compound complete all as specified and directed.
Dismantling 6mm thick asbestos cement plain building boards from ceiling including cover fillets all as specified as directed.
S & F for anodised aluminium snap grid frame work size of grid 605 x 605 mm for false ceiling all as specified
S & F hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long complete all as specified and directed.
S & F 4 mm thick Non asbestos designer fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws all as specified and as directed.
M&L for preparation of old wall surfaces complete removal existing finishes including filling of small holes etc and applying two coat of oil bound distemper over a coat of alkali resistant priming paint over one coat of putty minimum 3 mm thick complete all as specified as directed.
M&L for finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) after preparation of old wall surfaces with complete removal of existing finishes complete all as specified and directed.
M&L for Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick spread, levelled and rammed including watering complete all as specified and directed.
M&L for Cement concrete (1:4:8) Type D2 using 40 mm graded aggregates as in foundations, filling and mass-concrete complete all as specified and directed.
M&L for PCC 100mm thick (1:2:4) Type B2 (using 40 mm graded stone aggregate) used as in sub base floor/pavings and finishing cement concrete surface without using extra cement complete all as specified and directed.
M&L for Sand filling under floors or in foundation including watering and consolidation complete all as specified and directed.
M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade with grey cement and pigments complete all as specified and directed.
M&L for rendering 15 mm thick in CM (1:4) on fair faces of brick work or concrete surfaces of wall, surface finished even and smooth without using extra cement complete all as specified and directed.
M&L for PCC (1:2:4) Type B0 (using 12.50 mm graded stone aggregate) used as in copings complete all as specified and directed.
Supply, Laying and Testing of Reinforced concrete pipes class NP2 , laid and jointed complete with collars 150mm bore complete all as specified and as directed.
M&L for machine cut kota stone slab flooring 20-25mm thick over 20mm cement screed base of cement mortar (1:4) laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as spd and directed.
M&L for kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as spd and directed.
Taking down cement plaster of any description on concrete surfaces such as soffit of chajjas and brick walls etc incl raking out joints, hecking for key scrubbing down with water and removal of rubbish off the premises complete all as specified and directed
M&L for rendering 10 mm thick cement plaster in cement mortar (1:6) on brick work or concrete surfaces including finished even and smoothh without usig extra cement complete all as specified and directed
M&L for Rendering 15mm thick in CM (1:4) using liquid waterproofing compound as per manufacturer instruction on fair faces of brick work or concrete surfaces finished even and smoothh without usig extra cement complete all as specified and directed Note : WPC will be paid separately.
M&L for preparation of newly plastered surfaces of wall and applying three coats of white wash complete all as specified and directed.
M&L for applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. (Make: M/s Apex Ultima of Asian/ Weather Coat all guard of Berger/Xtra Tough of Shalimar).
Dismantling wall and ceiling board of any descrition complete all as specified and directed.
S & F 6mm thick non asbestos fibre cement building boards fixed or laid/inserted to timber/GI/Aluminium framework with screws as in ceiling complete all as specified and as directed.
Dismantling timber scantlings 40 sq. cm and over in section in unframed work, in any position complete all as specified and directed
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed
Errection fixing only Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified and directed.
S&F roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified and directed.
M&L for 75mm thick Cement concrete type C-1, 1:3:6 (using 20mm graded stone aggregate) as in plinth protection complete all as specified and directed
M&L for brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 complete, all as specified and as directed.
M&L for brick work using old size bricks (except Bricks) straight or curved on plan exceeding 6.00 Meter mean radius, built in cement mortar (1:6) complete all as specified and directed.
M&L for brick work with flyash bricks straight or corve on plan to any radius in half bricks thick walls, built in cement mortar (1:4) complete all as specified and directed.
M&L for Reinfocement cement concrete (nominal mix) type B-1 (1:2:4) using 20mm graded aggregate in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed
M&L for reinforced cement concrete (nominal mix) type B1(1:2:4) (using 20mm graded stone aggregate) in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed
M&L for reinforced cement concrete (nominal mix) type B1(1:2:4) (using 20mm graded stone aggregate) in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed
M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finihed surfaces complete all as specified and directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams for rough finished surfaces etc complete all as specified and directed.
S&F Mild Steel TMT bars 10mm and over, cut to lenghth, bent to shape requird, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clip all as directed by Engineer in Charge.
All as per item No 64.00 mentioned here-in-above 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed.
M&L for Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed
S&F 35mm thick 2nd class hardwood, factory made plain framed, panelled shutters (two panel), with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS :1003 (Part I), kiln seasoned and chemically pressure treated complete all as specifiedd and directed by Engr-In-Charge.
S&F 35mm thick 2nd class hardwood glazed & skeleton shutters, open repeated & prepared to received glass gauze etc. (without sash bars) edges of framing plain for securing glass etc, fitted to chawkhats complete all as specifiedd and directed by Engr-In-Charge .
S&F Mild steel flat iron 25x6mm as in hold fasts including all necessary cutting etc complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in bed block for fixing of hold fasts etc complete all as specified and directed
S&F 2nd class Small fittings such as brackets of any type, latch and hinge blocks, shaped door and window stops and the like, including all necessary' labours; articles n exc 200 cu. cm each all as specified and directed by Engr-in-Charge
M&L for preparing surfaces of wood and wood based materials, steel and iron work, new or old, of any description and girth, not otherwise described treating ends of posts, backs of chowkats, etc., area tarred exc 0.1 sq. m but n exc 0.5 sq. m each and treated with tar or coal tar black paint complete all as specified and directed.
M&L for preparing surfaces of wood and wood based materials, steel and iron work, new or old, of any description and girth, not otherwise described treating small articles such as stop, covers, gully gratings, holdfasts, ends of posts, backs of chowkats, etc.,area n exc 0.1 sq. m each and treated with tar or coal tar black paint complete all as specified and directed
S&F Butt hinges 100 size medium weight cold rolled complete all as specified and directed
S&F 200mm Mild steel barrel tower bolts, stove enamelled black, with bright bolt complete all as specified and directed.
S&F 125mm Cast iron or malleable cast iron handles, cast type, stove enamelled black complete all as specified and directed
S &F Mild steel sliding door bolts 300mm long, plate type stove enamelled black with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and two on staple plate and fixed complete all as spd and directed by Engr-In-Charge .
S&F MS ordinary rat tail rod pattern spring 300mm including roller and roller plate on wooden/steel choukhat including welding, riveting etc complete all as specified and directed by Engr-in-Charge.
S&F stainless steel wire cloth of 0.36 mm nominal dia of wire and averaging of width of aperture 1.40mm, fixed with stainless steel wire staples including taking out old wire cloth complete all as specified and directed.
M&L for painting on new wooden based surfaces of any description not other wise described over 10cm width or girth applying two coat synthetic enamel paint over one coat of pink primer including preparation of surfaces complete all as spd and directed by Engr-In-Charge .
S&F steel windows with side hung shutters including projecting type hinges with steel handle and steel peg stay ,complete with glazing bars dovetailed or welded incluing one shop coat of redoxide zinc chorome primer complete all as specified and directed.
All as per item No 81.00 mentioned here-in-above, but without glazing bars complete all as specified and directed.
M&L for framed work such as grills etc with endsof bars shouldered nd or riveed or forged into spike, framed guard bars and similar work conforming to Fe 290 Gde-E-165 complete all as specified and directed.
M&L for 3mm thick plain sheet glass ordinary quality & glazing with oil putty n.exc 0.50 Sqm in each pane complete all as spd and directed by Engr-In-Charge .
M&L for two coats synthetic enamel paint over a coat of red oxide primer on new steel surfaces incl preparation of surfaces over 10 cm width or girth complete all as specified and directed.
M&L for two coats synthtic enamel paint over a coat of red oxide primer on old steel surfaces incl preparation of surfaces over 10 cm width or girth complete all as specified and directed.
M&L for PCC (1:2:4) type B-1 (Using 20mm graded stone aggregate) as in roof kerbs or mud stop rounded complete all as specified
M&L for Plain Cement concrete type C-2, 1:3:6 (using 40mm graded stone aggregate) in surface channels and drains complete all as specified and directed.
Extra for fair finish drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms moulds, mitred/stopped ends etc cmplete all as specified & directed by Engr-in-Charge
M&L for 100mm thick Cement concrete type C-2,1:3:6 (using 40mm graded stone aggregate) as in subbase of floor complete all as specified and directed.
M&L for chequered cement concrete coloured tiles of size 30 cm x 30 cm x 25 mm thick, set jointed and pointed in neat cement slurry ( with grey cement and pigment) after and including 20mm thick screed bed in cement mortar (1:6) for fixing tiles compplete all as specified and directed.
Removing of excavated materials to a distance n. exc 50m and depositing where directed at a level n exc 1.5m above the starting point in oft/loose soil complete all as specified.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out soft/loose soil complete all as specified and directed
Excavating in post holes not exc 0.5 cum, in soft soil and getting out , returning , filling in and ramming earth in layers not exc 25 cm, watering and removing surplus soil to a distance not exc 50 m and making good surfaces all as required.
M&L for PCC 1:3:6 type C-2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed.
S&F MS wk as in Post, framed roof trusses, purlins, rails, MS plate and fristing incl distances pieces, cleats, MS plate etc conforming to Fe 410 - O or Fe 310 - O complete all as specified and directed.
S & F 0.50 mm thick Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and as directed.
M&L for 100mm thick plain cement concrete type C2, 1:3:6 using 40mm graded aggregate as in sub base complete all as specified and directed.
M&L for 75 MM thcik plain cement concrete type B-1, 1:2:4 (Using 20mm graded aggregate as in floor complete all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in loft/loose soil complete all as specified and directed
S&F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete (Fe-410W, E-250, Gde A) , drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed
S&F 1.25mm thick Mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and directed
M&L for Rendering 10 mm thick in CM 1:4 using liquid waterproofing compound as per manufacturer instruction on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
Supply only Liquid water proofing compound complete all as specified and directed
M&L for Glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry over 10 mm thick bak coat with cement mortar 1:4 even and fair and pointed in white or colour cement to match complete all as spd and directed.
Surface excavation n.exc 30 cm deep and and avg 15 cm deep and getting out soft and loose soil complete all as specified and directed.
Excavation in trenches, n. exc. 1.5 m wide and n. exc 1.5 m in depth ,for foundation, laying of pipes, cables etc. or for shafts , wells, cesspits, manholes, pier holes, etc. n.exc. 10 Sqm on plan and n. exc. 1.5 m in depth and getting out in hard/dense soil complete all as specified and directed
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and directed
M&L for reinforced cement concrete M-25 Design mix using 20mm graded stone aggregate) foundations, including rafts, footings, foundation beams, plinth beams; bases for columns, etc. and mass concrete etc complete all as directed.
M&L for reinforced cement concrete M-25 Design mix using 20mm graded stone aggregate as in Columns, pillars, piers, etc complete all as specified and directed.
M&L for reinforced cement concrete (nominal mix) type B-1 1:2:4 (using 20mm graded stone aggregate) in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed
M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams, and similar work, vertical or to batter complete all as specified and directed
M&L for formwork to sides and soffits of floor or roof beam,beam hauchings, girders, bressum-mers, lintels cantilever, shelves including supports, overhangs, etc also splays between floors and beams etc complete all as specified and directed.
Formwork to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and directed
M&L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
All as per item No 115.00 mentioned here-in-above but 6 to 8 mm dia complete all as specified and directed.
Rendering 15mm thick in cement and sand mortar 1:6 (Internally) on brick or concrete surfaces including finished even and smooth without using extra cement complete all as specified.
Rendering 15mm thick in cement and sand mortar 1:4 (Externally) mixed with water proofing compound @ 3% by weight of cement on brick or concrete surfaces including finished surfaces even and smooth without using extra cement complete all as specified and directed.
Rendering 5mm thick in cement and sand mortar (1:3) on concrete surfaces (ceiling) finished even and smooth without using extra cement, complete all as specified & directed.
M&L for cement concrete type B0 (1:2:4) (using 12.5 mm graded stone aggregate) 25 mm thick as in floor for receiving screed bed of floor tiling complete all as specified and directed.
M&L for non skid ceramic coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm in floors laid over 15mm thick 1:6 cement mortar screed bed etc. set and jointed in neat cement slurry and pointed in white of coloured cement to match complete all as specified and directed.
M&L for non skid ceramic coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm in floors laid over 10mm thick 1:3 cement mortar rendering jointed in neat cement slurry and pointed in white of coloured cement to match complete all as specified and directed.
M&L for cement concrete type C2 1:3:6 (using 40mm graded stone aggregate) 75mm thick as in plinth protection complete all as specified and directed.
M&L for preparation of newly plastered surfaces of wall & applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed
M&L for prepration of newly plastered surfaces of wall and applying two coat of oil bound distemper over a coat of alkali resistance primer complete all as specified and directed.
M&L for 2nd class Hard Wood plain, solid, straight chowkhats and frames wrought framed rebated on the solid rounded or chamfered put together with glue pinned at joints complete all as directed by Engineer-in-Charge.
S&F 35 mm thick factory made plain framed panelled shutters (any number of panels), with panels of timber flat on both side (feather edged) or veneered particle board, medium density, wood particle board with commercial face veneers complete all as directed by Engineer-in-Charge.
S&F Butt hinges mild steel 100mm long, medium weight, cooled rolled complete all as specified and directed.
S & F 150mm long extruded Aluminium alloy handles, fabricated type, anodised complete all as specified and directed
S & F 150mm long extruded Aluminium anodized barrel tower bolt of extruded section and fixed complete all as specified and directed.
S&F aluminium alloy,300mm long anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed
S&F floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor 150mm long complete all as specified and directed
Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed
Non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screw designer type complete all as specified and directed
Sheet glass, 4,0 mm thick ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and directed
Preparation of new painted surfaces of steel and applying two coat synthetic enamel paint to steel surfaces of any description not otherwise described over 10cm width or girth complete all as specified and directed.
Excavation over area ,not exc 1.5 mtr deep and gatting out the loose soil complete all as specified and directed.
Supply and lay for dry river sand filling for cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying complete all as specified and directed. Note :- Punned thickness 18 cm shall only be considered for payment.
M&L for PCC (1:3:6) type C-2 (using 40mm graded stone aggregate) as in bed to drain pipes including forming cradels for 150 mm bore pipes complete all as specified and as directed
Removing surplus soil to a distance not exceeding 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and as directed.
E/M Portion Taking down carefully aluminium conductor point wiring (light,fan,socket or power) complete including fittings such as switches,ceiling roses, pendants, regulators ,sockets etc. and removing (except those to be reused shall be kept in safe custody at the site ) and making good disturbed surfaces of walls, floors etc.to match with the existing complete all as specified and directed.
M&L for point wiring for light point/ fan point, one light/fan/exhaust fan point controlled by one, one way switch using 1.5 sqmm nominal cross sectional area multistranded copper conductor ,PVC insulated unsheathed FRLS cables in and including 20 mm dia or higher size PVC concealed conduits and fittings of medium grade, including pressed steel terminal switch boxes/ modular, 3 mm thick bakelite sheet top cover (ISI Marked) fitted with chromium plated brass screws & washers and 1.5 sqmm nominal cross sectioanl area multistranded copper conductor FRLS PVC insulated unsheathed earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed.
M&L for point wiring for socket outlet 3 pin, 5 amps on Independent board controlled by one, one way switch using 2.5 sqmm nominal cross sectional area multistranded copper conductor ,PVC insulated unsheathed FRLS cables in and including 20 mm dia or higher size PVC concealed conduits and fittings of medium grade, including pressed steel terminal switch boxes/ modular, 3 mm thick bakelite sheet top cover (ISI Marked) fitted with chromium plated brass screws & washers and 2.5 sqmm nominal cross sectioanl area multistranded copper conductor FRLS PVC insulated unsheathed earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed.
All as per item No 143.00 mentioned here-in-above but 5 Amp socket on same board with other switches complete all as specified and directed.
M&L for wiring for socket outlet 3 pin, 15 amps on independent Boards controlled by one, one way switch using 4.0 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLS cables in and including 20 mm dia or higher size PVC concealed conduits and fittings, including pressed steel terminal switch boxes/ modular , 3 mm thick bakelite sheet top cover (ISI Marked) fitted with Chromium plated brass screws & washers and 4.0 sqmm nominal cross sectioanl area multistranded copper conductor, PVC insulated unsheathed FRLS cable earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed.
S&F switch piano flush type, single pole , 5/6 Amps, one way complete all as specified.
S&F switch socket combination 2 in 1 multipurpose 5 pin , (6 Amps ) flush type controlled by one switch complete all as specified.
S&F socket outlets 2 in 1, 5/6 Amps, 230/240 V complete all as specified and as directed .( For Same Board only)
S&F switch socket combination 2 in 1 , 6 pin , (16 Amps ) flush type controlled by one switch complete all as specified.
S&F ceiling rose surface bakelite 65 mm x 50 mm two to three terminal suitable for 230 Volts AC 6 Amps complete all as specified.
S&F stepped type electronic fan regulator flush type 240 Volts ISI marked complete all as specified .
S&F submain two single core, 4 sqmm nominal cross sectional area multistranded copper conductor FRLS cable, PVC insulated unsheathed 1100 Volts grade drawing in and including suitable size PVC conduit (ISI marked), concealed, including 4 sqmm nominal cross sectional area multistranded copper conductor FRLS cable, PVC insulated unsheathed 1100 Volts grade earth wire complete all as specified.
S&F submain two single core ,6 sqmm nominal cross sectional area multistranded copper conductor FRLS cable, PVC insulated unsheathed 1100 Volts grade drawing in and including nd including suitable size PVC conduit (ISI marked), concealed, including 6 sqmm nominal cross sectional area multistranded copper conductor FRLS cable, PVC insulated unsheathed 1100 Volts grade earth wire complete all as specified.
S&F in repair 01x 18 W LED batten light fittings, with T-8 tube rode, lighting fixture with extruded polycarbonate complete with all accessories and connection from ceiling rose with twin core twisted flexible copper conductor cable with suitable size and earthing complete, complete all as directed.
S&F in repair security light fittings 25 watts, minimumm lumen output 100 lumen/Watt, made up of pressure dia cast housing with prismatic polycarbornate diffuser and individual LED with secondary optic and IP65 including necessary connection complete suitable for pole dia 25mm complete with all accessories including connected with twin core twisted flexible copper conductor of suitable size complete all as directed.
S&F in repairs epoxy powder coated sheet metal enclosure for DBs, double door (when MCBs to be used), Vertical Triple pole and neutral 415 V, 12 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact complete all as directed.
S&F in repairs MCB SP, 6 to 32 Amps, 'C' series 10kA, 240 Voltsand to be housed in DBs including necessry connection complete all as specified and directed. (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating).
S&F in repairs MCB SP, 40 to 63 Amps, 'C' series 10kA, 240 Voltsand to be housed in DBs including necessry connection complete all as specified and directed. (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating).
S&F in repairs MCB SPN 63 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs complete including necessry connection all as specified and directed. (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating).
S&F MCCB 4 pole, 3 phase, 415 volt of capacity 125 Amp, 25 KA complete with proper copper thimbles, copper reducer etc all as directed.
M&L for earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI wire 4 mm dia as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth strip encased in and including 40 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS round bars 6mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SSR Part I complete all as specified and directed and testing on completion. Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
S&F steel body Exhaust ventilation fan of sweep 450mm with louvers complete all as directed by Engr-in-Charge.
Fixing/Hanging only ceiling fan and connecting up including provision of cable from ceiling rose or connector to fan all as specified.
S&F XLPE insulated armoured cable, 16 sqmm 4 core,1100 volts grade heavy duty cable,ISI marked passing through pipe, with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed complete all as sepcified. Note : (i) Earth work in excavation, sand cushioning, cable cover, cable protection, GI pipe shall be measured and paid separately under relevant item. (ii) Cable Route Indicator made of metal of height 300mm above GL duly written ''LT CABLE'' to be fixed on every 30 mtr distance with pcc (1:3:6), 150 mm below the GL, cost of indicator and pcc to be considered in this item rate.
Excavation in trenches not exceeding 1.5m wide and not exc. 1.5m depth and getting out in hard/dense soil complete all as specified and as directed.
Returning, filling, including spreading, leveling, watering and well ramming in layers not exc. 25cmin soft/loose soil complete all as specified and as directed.
Removal of excavated soil to a distance not exc 50 m and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as directed.
Supply and lay for dry river sand filling for cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying complete all as specified and as directed. (Note : Punned thickness shall be measured).
M&L for fly ash bricks locally available of size 25 x 12.5 x 7.5 cm laid dry width wise across the line of cable in trenches for protection of UG cable complete all as specified and directed.
S&F lamp holder, PVC/polycarbonate type with back plate straight or anfular suitable for batten fittings complete all as specified.
S&F LED bulb 7 watts, 240 volts, ISI marked complete all as specified.
S&F exhaust ventilation fan of sweep 450mm with louvers, 240 volts, metalic body, BEE 5 star rated, ISI marked complete all as directed by Engr-in-Charge.
S&F GI pipe light grade 40 mm dia of size for road cross of cable,ISI marked all as specified and directed.
S&F XLPE insulated armoured cable, 16 sqmm 2 core,1100 volts grade heavy duty cable,ISI marked passing through pipe, with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed complete all as sepcified.
S&F two single core, 4 sqmm nominal cross sectional area multistranded copper conductor FRLS cable, PVC insulated unsheathed 1100 Volts grade drawing in and including suitable size PVC conduit (ISI marked), concealed, including 4 sqmm nominal cross sectional area multistranded copper conductor FRLS cable, PVC insulated unsheathed 1100 Volts grade earth wire complete all as specified and directed.
S&F two single core ,6 sqmm nominal cross sectional area multistranded copper conductor FRLS cable, PVC insulated unsheathed 1100 Volts grade drawing in and including nd including suitable size PVC conduit (ISI marked), concealed, including 6 sqmm nominal cross sectional area multistranded copper conductor FRLS cable, PVC insulated unsheathed 1100 Volts grade earth wire complete all as specified and directed.
S&F01x 20 W LED batten light fittings, with T-8 tube rod, lighting fixture with extruded polycarbonate complete with all accessories and connection from ceiling rose with twin core twisted flexible copper conductor cable with suitable size and earthing complete all as specified and directed.
S&F epoxy powder coated sheet metal enclosure for DBs, double door (when MCBs to be used), Single pole and neutral 240 V, 8 ways with mounting fitted with bus bar, DIN channel, neutral link and incoming contact complete all as directed.
S&F MCB SP, 6 to 32 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs including necessry connection complete all as specified and directed. (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating).
S&F MCB SP, 40 to 63 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs including necessry connection complete all as specified and directed. (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating).
S&F MCB SPN 40 to 63 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs complete including necessry connection all as specified and directed. (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating).
S&F ceiling fan 1200mm size , BEE 5 star rated, ISI mark, 240V, 50 Hz all as specified and directed. (Make:- Bajaj/Crompton/Havells)
S&F exhaust ventilation fan of sweep 300mm with louvers,240 volts, metalic body, BEE 5 star rated, ISI marked complete all as directed by Engr-in-Charge.
S&F 20 W LED ultra slim light fittings, lighting fixture with extruded polycarbonate complete with all accessories and connection from ceiling rose with twin core twisted flexible copper conductor cable with suitable size and earthing complete, complete all as directed.
S&F XLPE insulated armoured cable, 16 sqmm 2 core,1100 volts grade heavy duty cable,ISI marked passing through pipe, with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed complete all as sepcified.
Excavation in trenches not exceeding 1.5m wide and not exc. 1.5m depth and getting out in hard/dense soil complete all as specified and as directed.
Returning, filling, including spreading, leveling, watering and well ramming in layers not exc. 25cmin soft/loose soil complete all as specified and as directed.
Removal of excavated soil to a distance not exc 50 m and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as directed.
M&L for sub class B bricks locally available of size 25 x 12.5 x 7.5 cm laid dry width wise across the line of cable in trenches for protection of UG cable complete all as specified and directed.
M/s. Kalpana Construction
M/S BHATTACHARJEE ENTERPRISE
M/S N B SEN CONSTURCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .