Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.2 LAccepted-AOC R O NAUSHERA DISTT RAJOURI J K 185151 | NAUSHERA | RAJOURI | JAMMU AND KASHMIR | 185151 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹32.0 L+₹44,102.65 (1.40%)Rejected-Finance | L2 | Rejected-Finance Being other than L1 | |
| 3 | L3₹32.8 L+₹1.2 L (3.80%)Rejected-Finance | L3 | Rejected-Finance Being other than L1 | |
| 4 | L4₹32.8 L+₹1.2 L (3.88%)Rejected-Finance | L4 | Rejected-Finance Being other than L1 | |
| 5 | L5₹33.3 L+₹1.7 L (5.43%)Rejected-Finance | L5 | Rejected-Finance Being other than L1 |
Tender Value
Refer Docs
EMD Value
₹45,000
Closing Date
29 Jan 2021, 6:00 pmClosed
GE 862 EWS
GE 862 EWs PIN-913862 c/o 56 APO
Spl repair to bldg No T-77 cover the drainage replacement of LT panel and UG cable and certain revenue work at Naushera under GE 862 EWS
2020_MES_401903_1
GER-67/2020-21
Open Tender
Civil Works
Item Rate
180 days
GE 862 EWS
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Yes
GE 862 EWS
₹45,000
Yes
4 Feb 2021
8 Dec 2020
1 Feb 2021
8 Dec 2020
29 Jan 2021
15 Jan 2021
Amount
Sch 'A' Part-I B/R Works Dismantling of plain or corrugated steel sheeting, any gauge, thickness including Nanital or similar pattern roof covering complete all as specified and directed.
Pre-painted galvalume aluminium zinc coated GI based corrugated steel sheet 0.50mm thick of approved colour having tensile strength 550 MPa as in roof covering/cladding to wall fixed with self tapping screws including side and end lap as per manufacturer’s instructions complete all as specified and directed.
Pre-painted galvalume aluminium zinc coated GI based plain steel sheet 0.50mm thick of approved colour having tensile strength 550 MPa as in ridges, fixed with self tapping screws including side and end lap as per manufacturer’s instructions complete all as specified and directed.
Dismantling timber scantling 40 Sq cm and over in section, in any position (framed work) complete all as specified and directed.
Roof trusses (framed), trussed, purlins, cranes gantries, , rails and fastening and heavy brackets framing (beam, tea, angle, channel or flat section) including distance pieces, cleats, etc. conforming to Fe-410-W (Gde - E-250) quality A complete all as specified and directed.
Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing conforming to Fe-410-W (Gde - E-250) quality A complete all as specified and directed.
Welded steel wire fabric supplied and fixed complete to wood or steel members n exc 4 KG per sqm complete all as specified and directed.
Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
Brick work with sub class ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed.
Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
Rendering 20mm thick on stone masonry in CM 1:6, finished even and smooth without using extra cement complete all as specified and directed.
Rendering 20mm thick on stone masonry in CM 1:4, finished even and smooth without using extra cement complete all as specified and directed.
Supply only integral water proofing compound complete all as specified and directed.
Preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of cement primer complete all as specified and directed.
Complete removal of existing treatment and applying two coats of cement base paint over a coat of cement primer on old surfaces complete all as specified and directed.
Preparation of new steel surface exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing rubbish off the premises complete all as specified and directed.
Vitrified tiles coloured10 mm thick (square/ rectangular) polished, area of each tiles exc 0.36 sqm but not exc 0.42 Sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface, laid over and including 15 mm thick screed bed in CM 1:4 complete all as specified and directed.
Reinforced precast cement concrete slabs 1:2:4, type B-1 (using 20mm grraded stone aggregate) laid over drain set in CM 1:4 complete all as specified and directed.
Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Mild steel TMT bars 6mm to 8mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends as in stirrups, spacers and binders including binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Rough excavation n exc 1.50 mtr deep as in loose/soft soil complete all as specified and directed.
Excavation in trenches, n.exc 1.5m wide and n.exc 1.5m depth for laying of cable and foundation of poles and stays and n. exc 10sqm on plan and getting out in soft/loose soil complete all as specified and as directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25 cm (soil) thickness all as specified and directed.
Removing of excavated material (soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Hard core of broken stone or boulder of gauge n.exc 63mm, deposited, spread and levelled in layers n.exc 15 cm thick, watered and well rammed to a true surface complete all as specified and as directed.
PCC 1:4:8, type D-2 (using 40mm graded stone aggregate) in foundation filling and mass concrete complete all as specified and directed.
Use & waste of formwork to sides of concrete foundation, footing, bases of colums, raft & raft beams, sides and soffits(if any) of foundation and plinth beam and similar works in rough finished flat surface of concrete complete all as specified and directed.
Reinforced Cement concrete type B1, 1:2:4 ( using 20 mm graded stone agg.) in foundation inlcuding rafts, fotings, foundation beams, plinth beams, base for columns etc basement slab under reamed piles and mass concrete complete all as specified and as directed.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc complete all as specified and directed.
Reinforced cement concrete 1:2:4 type B-1 (using 20mm graded aggregates) as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.
Formwork to sides of pillars, posts, struts, piers, column etc for rought finished surface of concrete complete all as specified and directed.
Reinforced cement concrete type B-1, 1:2:4 (using 20mm graded crushed stone aggregate) as in column, pillars, piers, struts etc complete all as specified and directed.
Formwork to soffits of suspended slabs such as roof slabs, landings and similar work; n exc 200mm thick (Horizontal and sloping) for rough finished surface of concrete complete all as specified and directed.
Reinforced cement concrete type B-1, 1:2:4 (using 20mm graded crushed stone aggregate) as in slabs supported on walls, beams, columns , roof, landings, shelves and the like complete all as specified and directed .
Rendering 10 mm thick in CM 1:4 on ceiling finished even and smooth without using extra cement complete all as specified and directed.
Rendering 15mm thick in CM 1:4 on fair faces of brick work, surface finished even and smooth without using extra cement complete all as specified directed.
Rendering 15mm thick in CM 1:6 on other than fair faces of brick work, surface finished even and smooth without using extra cement complete all as specified directed.
Preparation of new plastered surfaces of walls and applying two coats of distemper oil emulsion over a coat wall care putty complete all as specified and directed.
75mm thick PCC type C-1, 1:3:6 (using 20mm graded stone aggregate) as in plinth protection, laid in slope 1:12 from outer edge of the wall, finished even and fair, laid in alternate bays including providing 6mm wide joints throughtout thickness of plinth protection in concrete bays and in between walling and plinth protection, joints filled mastic filling comprising of one part of heated bituminous 85/25 and 3 parts of sand(all by weight) complete all as specified and directed.
Steel ventilators with top hung shutter including hinges, steel peg stay complete all as specified and directed.
Anodised aluminium frame for doors, windows and ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
Anodised aluminium door shutters, aluminium section weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, mortice lock, 1 No, floor door stopper, anodised aluminium snap beading, screws etc including powder coating of any colour (thickness of powder coating not less than 50 micron) complete all as specified and directed.
5.5mm thick sheet glass, ordinary quality fixed to aluminium doors in square exc 0.5 sq. m in each pane complete all as specified and directed.
12mm thick prelaminated partical board, interior grade both side decorative choice lamination fixed to aluminium doors or as in cup board cabinets similar works complete all as specified and directed
Brass mortice lock vertical type 100mm long with 4 levers complete all as specfied and directed.
Extruded Aluminium alloy butt hinges 100mm long with galvanised mild steel hinge pin anodised and fixed type C-21 complete all as specified and directed.
Aluminum alloy, anodised, sliding door bolt 150mm long, with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts & sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed.
Aluminium anodized barrel tower bolts 125 mm long of extruded section all as specified and directed.
Extruded aluminium alloy handles size 125 mm fabricated type anodised complete all as specified and directed.
3.0 mm thick frosted sheet glass ordinary quality and glazing with oil putty and steel pins or wooden beads in squares not exceeding 0.50 square metre in each pane, complete all as specified and directed.
Bib tap cast copper alloy with crutch or butterfly handle, chromium plated, fancy type, screwed for iron pipe, suitable for 15 mm bore complete all as specified and directed.
Viterous china wash down water closet pan, white (pedestal pattern), including plastic water closet seat, black/white, closed pattern with recessed bottom and cover and mild steel chromium plated or aluminised hinging device, (excluding fixing bolts, flushing cistern and flush pipe) and inlcuding set of CP jet with PVC pipe of superior quality complete all as specified and directed.
PVC low level flushing cistern 10 ltrs capacity white with inlet ball valve, float valve and handle including providing & fixing MS angle iron brackets, PVC flush pipe complete all as specified and as directed.
PVC connection 15 mm x 450 mm including PTMT nuts at both ends screwed for iron pipe of 15 mm bore complete all as specified and directed.
15mm bore Stop valve, fancy type screwed down, high pressure with crutch or butterfly handle, chromium plated, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
Gun metal/glove valve with iron wheel head screwed on both sides for iron pipes of 15mm internal dia complete all as specified and directed.
Rotational moulded polythylene water storage tank (ISI marked) with float valve, plastic lid cover, double layered, cylindrical vertical with closed top hoisted and fixed in position of capacity 500 ltrs including dismantling old unserviceable tank and making connections inlcuding suitable GI wash out, over flow, nipple and including ball valve of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (minium weight 15mm-142 gms complete all as specifed and directed.
Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule for 20mm bore pipe fixed complete all as specified and directed.
Cast iron soil, waste and vent pipes 100mm bore in any length with or without ears, with cement joints, laid in trenches or in floors/walls complete all as specified and directed.
Cast iron 100mm bend (any radius) complete all as specified and directed.
100mm dia cast iron P or S trap complete all as specified and directed.
PVC (SWR) pipes type 'B' single socketed in any length with rubber ring joints , laid in trenches or in floor, of bore 110 mm complete all as specified and directed.
PVC bend 110 mm complete all as specified and directed.
Vitreous China wash basin, white, bowl type of size 550x 400mm including 15mm bore pillar tap cast copper alloy, PVC connection 15mm length 450mm, low density PVC waste pipe of pressure 6kg/sqm complete all as specified and directed.
PVC waste pipe for WHB 32mm dia complete all as specified and directed.
15mm bore fancy type pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed.
15 mm bore galvanized iron GI tubing medium grade with all fittings such as bends, socket, Tee, Elbow, union, Nipple, short pieces and fixed to walls, ceilings or laid in floors complete all as specifed and directed.
Supply only PVC (SWR) 'S' trap 110mm bore complete all as specifed and directed.
PCC 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid and tested for 150 mm bore SGSW pipe complete all as specified and directed.
150 mm internal dia Salt-Glazed stone ware drain pipes laid in trenches over concrete bedding jointed in cement mortar 1:1 and tested complete all as specified and directed.
Taking down chowkhats or frames (without taking off shutters from the frames) n.exc 1.5 Sqm each and removing to store complete all as specified and directed.
Taking down chowkhats or frames (without taking off shutters from the frames) exc 1.5 Sqm but n exc 4.00 Sqm each and removing to store complete all as specified and directed.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for unreinforced complete all as specified and directed.
Pressed steel door frame of size 125x60 mm with one or more rebates including necessary fixing lugs, hinges, lock and strike plate etc including back filling to chowkhats in PCC 1:3:6 type C-0 using 12.5mm graded stone aggregate complete all as specified and directed.
PCC type B-1, 1:2:4 (using 20mm graded stone aggregate) as in coping, benching, hold fast, water troughs, bed block and the like including weathering, slightly rounded or chamfered angle and throating incuding necessary form work complete all as specified and directed.
PCC type B-1 1:2:4 (20mm graded aggregate) in roof kerbs, padding or mud stops rounded or chamfered on edges complete all as specified and as directed.
Factory made 2nd class hard wood 35 mm thick plain framed panelled shutters (two panel) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (part-I) kiln seasoned and chemically pressure treated complete all as specified and directed.
Factory made 35 mm thick 2nd class hard wood glazed and skelton shutters open rebated and prepared to receive glass, gauze etc (without sash bars) edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass, etc sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkhats complete all as specified and directed.
300mm MS ordinary rat tail spring of approved make including roller and roller plate complete all as specified and directed.
Aluminium anodized barrel tower bolts 150 mm long of extruded section all as specified and directed.
Extruded aluminium alloy handles size 150 mm fabricated type anodised complete all as specified and directed.
Butt hinges 100mm medium weight cold rolled mild steel complete all as specified and directed.
250 mm long mild steel sliding door bolt plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified and directed.
Stainless steel wire cloth, 0.56mm nominal dia of wire and average width of aperature 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed.
Preparation of new wooden surface exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E- complete all as specified and directed.
MS tubular Box type window (double rebate and double shutter) of MS rolled steel section conforming to IS-1038 and shall be ISI marked manufactured by ISI approved manufacturer, openable frames shall be fabricated of sections as approved by Engr-in-Charge, corner welded to form a solid fused welded joint, handles shall be of z section welded with openable frame box steel section used in outer frame, shutter frame and central frame shall be ERW secton of 16 gauge with fixing lugs to be fixed as per provision of IS-1038 except that top lugs shall not be provided , all shutters of windows shall be provided with 4 Nos friction free hinges, 2 Nos 75 mm tower bolts to each leaf of window one at top and one at bottom welded on 3 mm thick steel sheet piece of suitable size which shall be in turn welded to z section of steel window to provide suitable arrangement of using tower bolt. Glazed, gauzed window , mild steel casement stays 300 mm with hinged joint and two plates with studs complete all as specified with all fittings and fixtures with or without glazing bars complete all as specified and directed.
Dismantling fillets, posts, rails, rafters purlins etc under 40 Sqcm in section unframed work complete all as specified and directed.
Brick work with sub class ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in CM 1:4 complete all as specified and directed.
Brick work with sub class ‘B’ bricks (Except bricks), straight or curved on plan exc 6m mean radius, built in CM 1:4 complete all as specified and directed.
Rendering 10mm thick on brick mansonry surfaces of wall, finished even and smooth without using extra cementcomplete all as specified and directed.
Demolition of reinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness (below or above ground) complete all as specified and directed.
25mm thick PCC type B1 1:2:4 (20 graded aggregate) as in sub base complete all as specified and directed.
Non skid ceramic coloured tiles 7 to 8 mm thick (Ist quality) Square/rectangular, area of each tile exceeding 0.11 sqm but n.exc 0.18 sqm in floors, etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles, laid over and including 15mm thick screed bed in CM 1:4 complete all as specified and as directed.
Glazed ceramic coloured tiles of size 450x 300x7mm/300x200x7mm thick as on vertical surface of wall such as skirting, dado, riser etc,set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile complete all as specified and as directed.
Demolition of Reinforced cement concrete of any description and in any position not otherwise specially provided for complete all as specified and directed
4mm thick designer ceiling board in ceiling fixed with screw as per manufacturers instructions , laid over and including hot dipped galvanised iron in post grid with 24mm wide T section exposed flanges which shall be powder coated white. The frame work shall comprise of main runner made from 0.33 mm thick galvanised steel sheet of size 24 x 32 x 300 mm spaced at 1200 mm centres securely fixed to the structural soffits by approved hangers at 1200mm maximum centres. Hangers of GI wire 4 mm dia to be fixed by approved rawl plug, level adjusters and screws etc. The last hanger at the end of each main runner shall not be greater than 450 mm from adjacent wall flush fittings of 1200 mm long screws Tee with (double stiching) to interlocked between main runners at 600 mm centre to centre from 1200 x 600 mm modules cross tee longer than 600 mm modules to be formed by fittings 600 mm long cross tee, tee perimeter wall angle shall be of 0.45 mm thick galvanised steel of size 19 x 19 mm and 300 mm long of white colour all as per insturctions including dismantling existing board complete all as specified and directed.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm and removing surplus soil to a distance n exc 50m and making good surface in any type of soil complete all as specified and directed.
PCC type D2 (1:4:8), using 40 mm graded stone aggregates as in post hole filling and mass concrete complete all as specified and directed.
100mm thick PCC 1:5:10, type E-2 using 40mm graded stone aggregates as in sub base of floors and mass concrete complete all as specified and directed.
Machine pressed precast concrete interlocking paver block of any shape and size approved by EIC, ISI marked (IS:15658-2006) 80mm thick, M-40 grade (Medium Traffic), in paths and hardstanding,with grey cement, laid tightly over & including 25mm thick dry sand cushion (compacted) and joints filled with dry sand, colour and pattern as approved by GE, complete all as specified and directed.
Construction of soakage well 2.4 Mtr dia and 3 M deep including excavation and earth work in any type of soil, PCC 1:3:6 type C-2 in foundation, walls of honey combed masonry with top ring of M-25 reinforced concrete including intercerpting chamber and screen chamber made of Brick masonry in CM 1:4, RCC cover slab in M-25, interconnecting pipes of RCC complete filled with brick bats complete all as specified and shown on drawing No CE/TD 1202/2008 SH 1/2 & 2/2.
PCC type B-1 (1:2:4), using 20 mm graded stone aggregates in surface channels and drains complete all as specified and directed.
PVC (SWR) pipes type 'B' single socketed in any length with rubber ring joints , laid in trenches or in floor, of bore 110 mm complete all as specified and directed.
Extra for forming fair finish to drain or channel 30cm inner girth in cement concrete using extra cement including forms, moulds etc complete all as specified and directed.
Plain cement concrete 1:3:6 type C1 (Using 20mm graded stone aggregate) for protection of interlocking paver block rounded or chamfered on edges complete all as specified and directed.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out complete all as specified and directed.
Sch 'A' Part-II (E/M works) Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed.
Point wiring for one light point/fan point controlled by one-one way switch with 1.5 Sqmm (nominal area) single core FRLS, PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor cable drawing in and including non metalic rigid PVC casing & caping complete with all acessories including PVC sunk box ISI marked for mounting of switches, sockets, fan regulator etc with 3 mm thick plastic laminated bakalite sheet as top cover, and 1.5 Sqmm (nominal area) single core FRLS, PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor cable as earth wire upto common earth and connected to earth dolly compete all as specified and directed.
Description all as per Serial item No 110 above but for one 3 pin 5 Amp socket outlet on independent board complete all as specified and directed.
Description all as per Serial item No 110 above but for one 3 pin 5 Amp socket outlet on same board complete all as specified and directed.
Description all as per Serial item No 110 above but for one 3 pin 15 Amp socket outlet independent with cable 2.5 sqmm PVC insulated FRLS multistranded copper conductor cable with 2.5 sqmm single core multistranded FRLS copper conductor cable as earth lead complete all as specified and directed.
Switch piano, flush type single pole, one way 5 Amp, 240 volts complete all as specified and directed.
Switch piano, flush type single pole, one way 15 Amp, 240 volts complete all as specified and directed.
Socket 2 in 1, 3 pin 5 amp flush type complete all as specified and directed.
Socket out let 2 in 1, multipurpose 5 & 15 Amp flush type complete all as specified & directed.
Ceiling rose two to three terminal (65 x 50mm), PVC/ polycarbonate insulated body complete all as specified and directed.
Ceiling fan regulator elctronic, stepped type, hum free suitable to control speed of fan from 0 to 100% rotary type five step 240 volts AC complete all as specified and directed. Make Bajaj /Usha/havells/CG
Lamp holder insulated body PVC/ Polycarbonate type with back plate suitable for batten/angular/pendent fittings including LED lamp 07 watt complete all as specified and directed.
LED Tube light fitting T-5 LED, Battens type 1x 20 watts, 4 feet white Indoor decorative aluminium extruded, integrated type complete with all accessories prewired and connecting electrically to ceiling rose to fitting using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 sqmm complete all as specified & as directed by Engr in Charge. Make C&S model No. LTTB4F20WLED P/W or equivalent in Philips/Havells/Bajaj
Sheet metal enclosure MCB distribution board single pole & neutral 430 volts 8 way with IP-43 IK-09 protection double door complete with appropriate size bus bar and neutral link, fixed flush in wall including cutting and chases wall for fixing DB and making good disturbed wall surfaces to match with existing specification (Note-MCBs will be measured and paid for separately).
MCB SP 240 volt any rating from 5 to 32 amps conforming to IS 8828 of 1996, with rupturing capacity 10 KA ,inculding providing thimble for out going cable complete all as specified & directed.
MCB SPN 240 volts 40 amps conforming to IS 8828 of 1996, with rupturing capacity 10 KA ,inculding providing thimble for out going cable complete all as specified & directed.
Supply, Laying, connecting and testing in replacement of service cable of size 10 Sqmm 2 core 1100 volts grade heavy duty cable PVC insulated stranded alumn conductor, served with an inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 mtr apart including 4mm suspension wire or drawn in and including medium grade non metallic rigid PVC conduit as per site requirement, flat or circular complete all as specified and directed.
Supply and fixing in replacement environmental friendly, ultra modern, energy saving, surface mounted, decorative oval bulk head 10 watt 6000 K inbuilt LED luminaire comprising of high brightness LEDs, IP54 protection including connecting electricaly using cord flexible 3 core PVC insulated over all sheathed with flexible copper conductor of size 0.75 sqmm complete all as specified and directed.
Taking down ceiling fan, cable connection and dismantling blades and remvoing fan and blades to store complete all as specified and directed.
Painting to ceiling fan complete in situ with synthetic enamel paint by spraying including filling cavities with filler one coat after coeaning all dust etc complete all as specified and directed.
Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of the earth plate at a depth not less than 1.5 mtr below ground level, earth plate surrounded by and packed with 15 cm thick layer of char coal dust and common salt, earth lead GI wire 4.00 mm dia by means of bolts, Nuts, Check Nuts and washers of galvanized iron and thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15 mm bore and water pipe 20 mm bore GI light grade with funnel and wire mesh PCC chamber in cement concrete 1:3:6 type C-2 & RCC cover all as specified & shown in elect plate No. 3 of SSR part I of 2010 including testing on completion complete all as specified and directed.
Supply laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 Sq mm 2 core laid in trenches/ on poles/ under road crossing etc. complete all as specified and directed. complete all as specified and directed.
Supply laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 Sq mm 3.5 core laid in trenches/ on poles/ under road crossing etc. complete all as specified and directed. complete all as specified and directed.
Supply laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 Sq mm 3.5 core laid in trenches/ on poles/ under road crossing etc. complete all as specified and directed. complete all as specified and directed.
GI tubing light grade, 50 mm bore with GI fitting such as socket, elbow, bend etc for mechnical protection of cable including sealing ends of pipe with bitumenous preformed wooden wedge complete all as specified and directed.
Earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground earth pit not less than 2.25m deep below ground level with top edge of the plate not less than 1.5m deep below normal ground level connected to and including 32X6mm thick galvanised iron strip by means of bolts, nuts, checknuts and washers of galvanised iron or steel all as specified in electrical plate No 3 of SSR (2009) part-I including 40mm bore GI pipe light grade for protection of earth strip and PCC 1:2:4 type B-1 as in pit, Precast RCC earth pit cover 8 cm thick reinforced with 8mm dia TMT bars @150mmc/c and two handles, excavation and earth work in any type of soil and alternate layers of charcoal, common salt and 20mm bore galvanised medium grade steel tubing for watering with one end fixed with cast iron funnel and wire mesh and testing on completion complete all as specified and directed. Note:-Earth strip and protection pipe upto board is included in the rate quoted.
Sand cushioning to underground cable, provided with a layer of 8 cm deep before laying the cable and 15 cm thick after laying and stretching jointing and testing the cable complete all as specified and as directed Note: Punned thickness of sand shall be measured and paid.
Brick covering with width equal to length of brick as mechanical protection to cable using sub class ‘B’ bricks laid flat, size 230mm x 115mm x 75mm, complete all as specified and as directed
Supply, installation, commis-sioning of Water cooler partially stainless steel, electric driven single phase having approx storage and nominal cooling capacity 60/120 Ltrs complete all as specified and directed. Make - LG/Whirlpol/voltas/Blue Star
Voltage stablizier for automatic operation single phase naturally aire cooled indoor type & desined for input variation between 170 V to 270 V with outdoor voltage stabilized at 230 V with accuracy of ± 2.5 % and capacity 1.0 KVA complete all as specified and directed.
Supply laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 Sq mm 4 core laid in trenches/ on poles/ under road crossing etc. complete all as specified and directed. complete all as specified and directed.
Cutting existing steel tubing 15/20mm for addition/alteration complete all as specified and as directed
Note:- The contract sum arrived after deduction of amount of Sch of credit as listed in tender Documents.
M/S Jasbir Singh
M/S KEWAL KRISHAN SANJEEV KUMAR VAID
M/S Narinder Pal Choudhary
M/S Darshan Kumar
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .