Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.0 LAccepted-AOC | L1 | Accepted-AOC lowest bid quoted | |
| 2 | L2₹39.7 L+₹1.6 L (4.27%)Rejected-Finance N A | NEW DELHI | DELHI | 110001 | L2 | Rejected-Finance Highest bid quoted | |
| 3 | L3₹39.8 L+₹1.7 L (4.38%)Rejected-Finance A 47D RAM DUTT ENCLAVE UTTAM NAGAR NEW DELHI 110059 | WEST | DELHI | 110059 | L3 | Rejected-Finance Highest bid quoted | |
| 4 | L4₹46.2 L+₹8.1 L (21.2%)Rejected-Finance | L4 | Rejected-Finance Highest bid quoted | |
| 5 | Rejected-Technical | - | Rejected-Technical Rejected due to not enlisted in b (i) |
Tender Value
₹45.2 L
EMD Value
₹91,000
Closing Date
16 Nov 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Gurgaon
Gurgaon
PROVISION OF CERTAIN BR AND EM SANCTIONED WORK AT AF STATION ARJANGARH UNDER GE AF GURGAON
2021_MES_483055_1
CA NO GE/GUR-/NIT-61/2021-22
Open Tender
Miscellaneous Works
Piece-work
240 days
GE (AF) Gurgaon
PROVISION OF CERTAIN BR AND EM SANCTIONED WORK AT AF STATION ARJANGARH UNDER GE AF GURGAON
8 documents required · 8 mandatory
₹500
GE (AF) Gurgaon
₹91,000
20 Dec 2021
21 Oct 2021
18 Nov 2021
21 Oct 2021
16 Nov 2021
3 Nov 2021
60 days
Amount
Taking down cement plaster on brickwalls & concrete surfaces & the like including racking out joints, hacking for key scrubbing down with water etc. any description, complete all as specified and as directed by Engr-in-charge.
M&L for Rendering 15mm thick on fair faces of brick work or concrete in CM (1:6) & rendering is to be finishing even & smooth without using extra cement complete all as specified and as directed by Engr-in-charge.
M&L for Rendering 15mm thick on fair faces of brick work or concrete in CM (1:4) & rendering is to be finishing and fair complete all as specified and as directed by Engr-in-charge.
M&L for Rendering 10 mm thick over ceiling of brick work or concrete surface in CM 1:3 finished even & smooth without using extra cement complete all as specified and as directed by Engr-in-charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store & rubbish off the premises complete all as specified and as directed by Engr-in-charge.
M&L for first quality coloured glazed ceramic tiles, fixed in pattern of different colour including border of size 300x 450 x 7mm thick as in vertical surfaces such as dado/skirting, set and jointed in neat cement slurry and pointed in white or coloured cement to match with colour of tiles laid on and including 10 mm thick rendering in cement mortar (1:3), including pointing in white cement with pigment to match the shade of tiles, complete all as specified and as directed by Engr-in-charge.
M&L, for Non-skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.06 sqm but n.exc 0.11 sqm, in floors etc. set & jointed in neat cement slurry & pointed in white or coloured cement over 15mm thick screed bed in CM (1:6) complete all as specified and as directed by Engr-in-charge.
M&L for 600mmx600mmx8-10 mm thick vitrified light colored tiles and including 20mm thick screed bed in CM 1:4 in flooring set and jointed in neat white cement incl pigment to match the shade of the tile complete all as specified and as directed by Engr-in-charge.
M&L for 600mmx600mmx8-10 mm thick vitrified dark colored tiles and including 10.mm thick screed bed in CM 1:4 in skirting/dado set and jointed in neat white cement incl pigment to match the shade of the tile complete all as specified and as directed by Engr-in-charge.
Demolition of brick work in any position, built in cement morter or cement lime mortar etc complete all as specified and as directed by Engr-in-charge.
M&L for Brickwork with sub class ‘B’ bricks straight or curved on plan exc. 6mtr mean radius built in cement mortar 1:4 using old size bricks, complete all as specified and as directed by Engr-in-charge.
Demolition of cement concrete of any description (un-reinforced) in ground floors and paving n exc. 15 cm thickness (below or above ground level) complete all as specified and as directed by Engr-in-charge.
M&L, for 75mm thick cement concrete (1:3:6) type C-2 as in plinth protection, laid joints at interval of 3mtr, at corner and along the wall and filled with bitumen sand mixed in equal perportion complete all as specified and as directed by Engr-in-charge.
M&L for 40mm thick PCC (1:2:4) type B-1 using 20mm graded stone aggregates as in flooring finished even & smooth without using extra cement, complete all as specified and as directed by Engr-in-charge.
Supply only Glass dividing strips, 3 mm thick, 38mm wide & inserted in position to confirm to design, complete all as specified and as directed by Engr-in-charge.
M&L for Plain cement concrete 1:4:8 Type D-2 (using 40mm graded stone aggregate) 100 mm thick as in sub base complete all as specified and as directed by Engr-in-charge.
M&L for Chequered cement concrete tiles exc 0.09sqm and n.exc 0.16 Sqm & 20mm thick with grey cement and pigments (as approved) , set and jointed and pointed in neat cement slurry in floors, laid over 15mm thick cement screed bed of CM (1:6), complete all as specified and as directed by Engr-in-charge.
M&L for 20 mm thick fine sand cushion complete all as specified and directed by Engineer -in - Charge.
M & L for Machine pressed precast conctete interlocking paver blocks with grey cement and pigments of any shape and size confirming to IS: 15658-2006 of 80 mm thickness M-40 Grade with joints filling with sand over complete all as specified and as directed by Engineer -in - Charge.
Hacking out old broken glass of any thickness, size, quality or description from n exc. 0.50 sqm in each pane metal frame glazed with oil putty or fixed with beads including punching or out old glazing pins, spring clips, complete all as specified.
S&F, 4mm thick sheet glass ordinary quality & glazing with oil putty in square n exc. 0.50 sqm in each pane complete all as specified and as directed by Engineer -in - Charge.
S&F in 4 mm thick frosted glass in square nexc .5 sqm each pane fixed with putty (in metal frames etc) complete all as specified and as directed by Engineer -in - Charge.
S&F as in repairs stainless steel wire cloth, 0.36 mm nominal dia of wire & average width of aperture 1.40mm & fixed with tinned tacks, or galvanised wire staples complete all as specified and as directed by Engineer -in - Charge.
S& F in repair Helical door spring 150 mm, ordinary rat tail rod pattern springs including roller and rollar plate, fixed including welding/ fixing to steel/ wooden chowkats, complete all as specified and as directed by Engineer -in - Charge.
S&F in repair Wash hand basin, vitreos china, flat back of size 550 X 400 mm with pedestal, including cutting for & pinning in ends of brackets or erecting stand including brass waste coupling, waste pipe complete all as specified and as directed by Engineer -in - Charge.
S&F Vitreous China wash down water closet'constellation white colour complete set incl PVC valveless, syphonic action type, flushing cistern of 10 litres capacity, low level, white, with inlet, ball valve, float & handle including brackets. with lid cover , including connection to wate pipe, flushing pipe, anti-syphonage pipe etc. and making good to floor complete all as specified and as directed by Engineer -in - Charge.
S&F in repair china water closet Orrisa pattern, size 580x 440 mm white, with integral foot rest and cast 'P' or 'S' trap including cement concrete including connection to flushing cistern/pipe and making good disturbed portion to match existing surface complete all as specified and as directed by Engineer -in - Charge.
S&F in repair PVC valveless, syphonic action type, flushing cistern of 10 litres capacity, low level, white, with inlet, ball valve, float & handle including brackets complete all as specified and as directed by Engineer -in - Charge.
S&F in repiar PVC connections of PTMT, non corrosive, with nuts & washers on both ends, 450mm longs suitable for 15mm bore, ISI marked, complete all as specified and as directed by Engineer -in - Charge.
S&F in repiar PVC connections of PTMT, non corrosive, with nuts & washers on both ends, 600mm longs suitable for 15mm bore, ISI marked, complete all as specified and as directed by Engineer -in - Charge.
S&F in repair Grating rounded 100 mm size of PTMT (min wt 50gm) as in repairs, complete all as specified and as directed by Engineer -in - Charge.
Taking up or down 15 mm steel tubing & connections fixed complete to walls and ceiling or laid in floors, complete all as specified and as directed by Engineer -in - Charge.
Taking up or down 20mm dia bore of galvanised Iron steel tubing and connections including cleaning for refixing, cutting/chauging in wall/floor complete all as specified and as directed by Engineer -in - Charge.
S&F 15mm bore dia of medium grade galvanised steel tubing with all fittings and fixed complete to wall or laid in floor complete all as specified and as directed by Engineer -in - Charge.
S&F 20mm bore dia of medium grade galvanised steel tubing with all fittings and fixed complete to wall or laid in floor complete all as specified and as directed by Engineer -in - Charge.
M&L for Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exceeding 10 cm girth, including removal of rubbish outside MoD land complete all as specified and as directed by Engineer -in - Charge.
M&L for Cutting holes into or through brick/ concrete walls built, in cement mortar, exceeding 150 Sqcm but not exceeding 400 Sqcm in superficial area and making good in cement mortar 1:3 to match with the existing finishes, complete all as specified and as directed by Engineer -in - Charge.
S&F in repairs 15mm bore dia of bib tap cast copper alloy with crutch or butterfly handle screwed down for iron pipe ISI marked complete all as specified and as directed by Engineer -in - Charge.
S&F in repairs 15 mm dia brass chromium plated pillar tap with fly nut capstan head screwed for 15 mm bore dia of pipe complete all as specified and as directed by Engineer -in - Charge.
S&F in repairs 15 mm dia fancy type chromium plated stop valve/Angular valve, alloy screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed by Engineer -in - Charge.
S&F in repairs chromium plated brass shower rose 125 mm dia with swivel joint complete all as specified and as directed by Engineer -in - Charge.
S&F in repairs 15 mm dia brass stop valves,cast copper alloy screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed by Engineer -in - Charge.
S&F in repairs 20 mm dia brass stop valves,cast copper alloy screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed by Engineer -in - Charge.
M&L, Granite (any type) table rubbed and polished of 18-20mm thick laid over 15 mm thick cement screed base of CM(1:6) and jointed with gray cement slurry pointed in white cement mixed with pigment to match the shade of the slab etc complete all as specified and as directed by Engineer -in - Charge.
S&F sinks as in repairs with drainage board made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes, including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 915mm x460mm bowl size 410mmx330mmx330mmx160 mm complete all as specified and as directed by Engineer -in - Charge.
S&F 500 lit capacity , rotational moulded polyethlene water storage tanks cylindrical with closed top hoisted, three layered including tank neeples and fixed as per SSR Pt-I etc complete all as specified and as directed by Engineer -in - Charge.
S&F 20mm bore Ball brass valves high pressure with polythene float and flynut complete screwed for iron pipe or brass ferrule and fixed etc complete all as specified and as directed by Engineer -in - Charge.
M&L for providing precast reinforcement cement concrete (1:2:4) type B-1 using 20mm graded aggregate in man holes covers slabs/ Shelves as in slabs supported on walls, beams and columns, in floors, roofs, landings, deck slabs and in shelves and like including necessary form work, complete all as specified and as directed by Engineer -in - Charge.
M & L for for mild steel deformed bars 08 mm dia & over cut to length , bent to shape required, including cranking, bending spirally binding wire (0.9mm dia annealed) complete all as specified and as directed by Engineer -in - Charge.
M&L for Preparation of new plastered surfaces of wall & apply two coat of oil bound distemper, over a coat of primer over 1-2mm thick putty complete all as specified and as directed by Engineer -in - Charge.
M&L for Preparation of old plastered surfaces of wall & apply one coat of oil bound distemper, complete all as specified and as directed by Engineer -in - Charge.
M&L for Preparation of newly plastered surfaces of wall of any description & applying two coats of exterior acrylic emulsion paint over a coat of primer over 1-2mm thick putty, complete all as specified and as directed by Engineer -in - Charge.
M&L for preparation of newly plastered surface of ceiling and applying three coats of white wash complete all as specified and as directed by Engineer -in - Charge.
M & L for preparation of newly plastered surface of wall and applying three coats of white wash complete all as specified and as directed by Engineer -in - Charge.
Taking down 100mm/75mm bore cast iron soil, waste and vent pipes including fittings by burning out lead joints etc to facilitate dismantling old serviceable fittings/pipes laid in trenches, floors or fixed to walls all as directed including earth worm, demolition of PCC/Brick work and making good to match with existing complete all as specified and as directed by Engineer -in - Charge.
S&F 100mm bore cast iron spun soil waste or vent pipes in any length with or without ears with cement joints fixed to wall all as directed(ISI marked) complete all as specified and as directed by Engineer -in - Charge.
S&F 75mm bore cast iron spun soil waste or vent pipes in any length with or without ears with cement joints fixed to wall all as directed(ISI marked) complete all as specified and as directed by Engineer -in - Charge.
S&F 100mm bore cast iron branch pipes single (equal or unequal) ordinary of inverted spigot or socket type (ISI marked) complete all as specified and as directed by Engineer -in - Charge.
S&F 75mm bore cast iron branch pipes single (equal or unequal) ordinary of inverted spigot or socket type(ISI marked) complete all as specified and as directed by Engineer -in - Charge.
S&F 100mm dia bore cast iron bends (any radius) diminishing pieces or tapers (large bore measured) (ISI marked) complete all as specified and as directed by Engineer -in - Charge.
S&F 75mm bore cast iron bends (any radius) diminishing pieces or tapers (large bore measured) (ISI marked) complete all as specified and as directed by Engineer -in - Charge.
S&F in repairs CI nahani trap with grating including jointing to waste pipe in run lead with dia of outlet 75 mm including floor around to required depth and burning lead joints etc to facilitate dismantling old CI trap and making good complete all as directed. (ISI marked) complete all as specified and as directed by Engineer -in - Charge.
S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber joints fixed to walls with necessary brackets fixed in repairs, complete all as specified and as directed by Engineer -in - Charge.
S&F 110mm bore PVC(SWR) bends with any radius etc, complete all as specified and as directed by Engineer -in - Charge.
S&F Stainless steel Kitchen Plate Rack of size 31" x 36" x 10" of 1 mm thick stainless steel sheet as in repairs complete all as specified and as directed by Engineer -in - Charge. Make : Nirali/Jayna/ Diamond
S&F fancy type Mild steel 20mm dia Drapery rod all fittings complete all as specified and as directed by Engineer -in - Charge.
S&F fancy type brackets for curtain Rod to fix on wall with nylone sleeves all fittings complete all as specified and as directed by Engineer -in - Charge.
S&F fancy type Knobs for Curtain Rod to fix Curtains Rod all fittings complete all as specified and as directed by Engineer -in - Charge.
M&L for Preparation of old surfaces of Ceiling including brooming down or steel wire brushing , scraping down smook soots moulds , moss and efflorescent salts and trading oil and greeses spots etc and applying two coat of white wash , complete all as specified and as directed by Engineer -in - Charge.
M&L for Preparation of old wooden surfaces over 10 cm width or girth not other wise described and applying one coat of synthytic enemel paint , of approved shade complete all as specified and as directed by Engineer -in - Charge.
M&L for Preparation of old steel or iron surfaces over 10 cm width or girth not other wise described and applying one coat of synthytic enemel paint(of approved shade) , complete all as specified and as directed by Engineer -in - Charge.
M&L for Complete removal of existing treatment from internal surfaces of walls by wire brushes, and stopping of surfaces & levelling / edging the disturbed places/edges where required using necessary filling wall chalk whitning to obtain smooth regular /even finish using sand paper and applying two coats of oil bound distemper ,(aproved shade) complete all as specified and as directed by Engineer -in - Charge.
M&L for prepare wall surfaces and applying 1 to 2 mm thick birla putty on wall for smoothing surfaces complete all as specified and as directed by Engineer -in - Charge.
S&F Bath room cabinet of PVC of size 355 x 455 mm and 125 mm to 150 mm depth, single or double door, including mirror top, fixed in repairs, complete all as specified and as directed by Engineer -in - Charge.
S&F fancy type, elegant design, double corner glass bathroom shelf, brass polished chrome, complete all as specified and as directed by Engineer -in - Charge.
M&L for powder coated aluminium frame work doors, windows, partions etc incl grill for windows for windows etc with one or more rebated section incl joiting cleats for fixing, anodised alumnium snap beading screw, alumunium hinges etc complete all as specified and as directed by Engineer -in - Charge.
S&F aluminium colour powder coated anodised door and shutter single or double leaf glazed/pre laminated board exterior quality partly glazed/pre laminated board exterior quality party glazed panels fabricated including aluminium powder coated beading rubber and packing materials and shall be drilling in existing wall and thrust bolt suitable size complete comprising the following:- (a) Aluminium colour powder coated door frame section 101.60x44.45x1.93 mm fixed as per spd (b) Aluminium colour powder coated vertical section in shutter 85x44.45x2 mm as per spd. (c) Aluminium colour powder coated Top Rail & style shutter section 95.25x44.45x2.00 mm as per spd. (d) Aluminium colour powder coated handle 02 Nos in each shutter 200 mm long as spd. (e) Aluminium colour a powder coated Tower bolt 02 Nos in each shutter 150 mm long as per spd. (f) Aluminium colour powder coated middle lock rail/bottom rail section 150x44.45x2.00mm cat No.20002. Make-Jindal (g) Six lever mortice lock brass Make : Godrej/Classic on in each door. (h) 12 mm thick particle board (pre laminated both face) exterior grade ISI Marked (j) Tinted glass/Plain glass 5mm thick Make : Saint gobain/modiguard. (h) Floor spring , Make:- Sandu/Amar ISI Note: Prelaminated particle board & tinted glass shall be measured and paid seperatly.
S&F powder coated anodised aluminium window and ventilator shutter fixed type without sash bars aluminium section weighting 0.55 Kg/Rm incl necessary joining cleats glazing clips rubber neoprene packing, handles two Nos in each door, hinges anodised aluminium snap beading screws etc complete all as specified and directed by Engineer-in-Charge.
S&F 19/20 mm thick prelaminated board, exterior grade, prelaminated one side with decorative choice lamination and other side balancing white lamination fixed with screws to aluminium frame work complete all as specified and directed by Engineer-in-Charge.
S&F Toilet paper holder ,chromium plated , fixed to walls with chromium plated (CP) brass screws, complete all as specified and directed by Engineer-in-Charge.
S&F Health faucet with tube and hooks, chromium plated fancy type fixed to plugs with chromium plated brass screws complete all as specified and directed by Engineer-in-Charge.
S&F Towel shelf ,chromium plated , complete all as specified and directed by Engineer-in-Charge.
S&F Soap dish , chromium plated , complete all as specified and directed by Engineer-in-Charge.
S&F SS Jet for water closet ,pedastal pattern complete all as specified and directed by Engineer-in-Charge.
S&F 15 mm bore central hole basin mixture , chromium plated, with copper pipe fixed in repair, complete all as specified and directed by Engineer-in-Charge.
S&F Wall mixture telphonic ,15 mm bore, chromium plated, fixed in repair, complete all as specified and directed by Engineer-in-Charge.
Taking down old wooden/steel windows incl grill of any patern and design if any & M&L for factory made box type steel window with pintol hinges & 2 Nos 150mm mild steel tower bolts to each shutter, steel handle and with glazing bars dovetailed or welded and with one shop coat of zinc chromate primer complete all as specified Note : (i) Glazed shutter with 4.00mm thick glass, Mesh shutter with 32 gauge stainless mesh and M.S. grill as shown in drg. as per of above mentioned drawing deemed to be inclusive in the rate quoted for unit. (ii) Glass, stainless steel mesh will be fixed to window by authorised rep of manufacture of window only.
M & L for Providing and injecting chemical emulsion for Post Constructional Antitermite Treatment Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron complete all as specified and directed by Engineer-in-Charge.
M & L for Providing and injecting chemical emulsion for Post Constructional Antitermite Treatment Along soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified and directed by Engineer-in-Charge.
Surface dressing not exceeding 15cm deep in soft/loose soil complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches n exc 1.5 m wide and n exc 1.5m in depth for foundation etc or for shifts wells cesspits, manholes,pier holes etc 10 Sqm on plan and n exc 1.5 m depth and getting out in hard dense soil complete all as specified and as directed by Engr in charge .
M/L Cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate in foundations, filling and mass concrete including sub base of floors complete all as specified and as directed by Engr in charge .
M&L for Providing, cement concrete 1:2:4 type B–1 using 20mm graded stone aggregates in roof kerbs or mud stops, rounded or chamfered on edges, complete all as specified and as directed by Engr in charge .
Returning, filling in, Hard/ dense soil including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed by Engr in charge .
Removal excavated material to distance not exceeding 100 metre and depositing where directed at level not exceeding 1.5 metre above the starting point in soil complete all as specified and as directed by Engr in charge .
M&L Brick work with sub class 'B' Bricks, straight or curved on plan exceeding 6 mtr mean radius built in CM 1:6 complete all as specified and as directed by Engr in charge .
M&L for Preparation of newly plastered surfaces of wall and applying two coat of Cement Base Paint of approved colour and shade by accepting officers over and including a coat of primer as per manufacturers instructions complete all as specified and directed by Engineer-in-Charge including necessary scafolding upto 4th floor.
S&F RCC Class NP 2, 300 mm bore pipes laid and jointed complete with collars complete all specified and as directed.
Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all specified and asdirected.
S&F 0.63mm Galvanised, corrugated mild steel sheeting with two corrugations side lap, fixed with L-type or J-type or cranked hook bolts in lieu of screws and washers, in roofs, walls etc. with grade of zinc coating all as specified and directed by Engineer - in - Charge.
Surface excavation not exceeding 30cm deep and averaging 15cm deep and getting out in Hard/dense soil all as specified and directed by Engineer - in – Charge.
M&L for damp proof course in cement concrete 1:2:4 type BO (40mm thick ) horizontal or vertical surface and directed by Engineer in charge .
M&L for use and waste of form work to soffits of suspended slab such as roof slab, floor slab landings and similar work not exceeding 200 mm thick for finish complete all as specified and directed by Engineer in charge .
M&L for use and waste form work to edges of concrete flats ,treads,breaks in floors window sillssides of rcc slabs exc 10 cm but not exc 20 cm etc rough finished surface of concrete complete all as specified and directed by Engineer in charge .
M&L RCC 1 : 1.5: 3, Type A–1 using 20mm graded aggregates for slabs supported on walls, beams, columns and in shelves, the like complete all as specified and directed by Engineer - in - Charge .
S&F TMT bars 8mm dia cut to length bent to shape required cranking, bending spirally for hooping for columns hooking ends and bindings with and including mild steel wire (Annealed) not less than 0.9m dia or securing with clips, asin stirrups complete all as specified and directed by Engineer - in - Charge.
M&L hard core of broken bricks aggregate of gauge not exc 63 mm deposited spread & leveled in layers not exc 15 cm thick watered and rammed to a true surface complete all as specified and directed by Engineer - in - Charge.
Supply only Liquid water proofing compound., complete all as specified and direceted.
S&F Factory made solid panel PVC door shutter 30mm thick (Style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded coloured PVC ’C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and single side prelaminated PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail; Panelling of single side prelaminated PVC sheet to be fitted in the MS frame welded/ sealed into the stiles and rails with suitable PVC sheet beading, and jointed together with solvent cement, supplying and fixing in the frame at site as per specification complete all as specified and as directed by Engineer-in-Charge.
S&F Solid PVC door frame factory made of size 50mmx 47mm made out of 5mm PVC sheet single side prelaminated & edges will be painted to match, reinforced with MS Square tube jointed , supplying and fixing in opening complete all as specified and as directed by Engineer-in-Charge.
M&L for Providing precast cement concrete 1:2:4, type B-0 louvers and jallies, 40mm thick (measured solid) including all mouldings set in cement mortar 1:4 all as specified and directed by Engineer - in - Charge.
S&F vitreous china squating pan, 'Orissa' pattern, size 580x440mm white, with integral foot rests, including 100mm cast iron 'P' or 'S' trap and 100mm cast iron sanitary connection socket to fit WC outlet including connection to trap, to flushing pipe, anti-syphonage pipe etc. complete all as specified and directed.
S & F Ist quality vitreous china wash basin, white, flat back, size 550x400mm, PVC connections suitable for hot and cold water,bottle trap (with internal partition) 32 mm size with 300mm &190mm long wall connection pipes & wall flange, and fixing withbrackets/bolts including cutting and pinning in etc complete all as specified and directed by Engineer - in – Charge .
S&F bib taps 15mm bore cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe all as specified and directed by Engineer - in - Charge .
S&F 15mm bore stop valve, cast copper alloy screwed down, high pressure, with crutch or butterfly handle, screwed both ends of iron pipe or for union and fixed all as specified and directed by Engineer - in – Charge.
S&F 75 mm PVC (SWR) pipe single socketed,in any length with rubber ring joints laid in trenches or in floors, all as specified and directed by Engineer - in - Charge.
S&F PVC (SWR) bands 75 mm (any radius), diminishing pieces or tapers (larger bore measured), all as specified and directed by Engineer - in - Charge.
S&F PVC (SWR) plain floor trap 75mm , with grating including jointing with solvent cement, all as specified and directed by Engineer - in - Charge.
S&F PVC (SWR) vent cowls for 75 mm bore, all as specified and directed by Engineer - in - Charge.
S&F 20mm bore stop valve, cast copper alloy screwed down, high pressure, with crutch or butterfly handle, screwed both ends of iron pipe or for union and fixed all as specified and directed by Engineer - in – Charge.
S&F PVC connection 15mm size with PTMT nuts of length 450mm all as specified and directed by Engineer - in – Charge.
S&F aluminum anodized 200mm long barrel tower bolt of extruded sections, all as specified and directed by Engineer - in - Charge.
S&F 100 mm long mild steel butt hinges medium weight cold rolled, all as specified and directed by Engineer - in - Charge.
S&F 150mm long extruded alluminium alloy handles fabricated type anodized, all as specified and directed by Engineer - in - Charge.
M&L 20 mm dia CP tubular towel rail with CP brass brackets D type 60 cm long between flanges, all as specified and directed by Engineer - in - Charge.
S&F 110mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed by Engineer - in - Charge .
S&F PVC (SWR) bands 110 mm (any radius), diminishing pieces or tapers (larger bore measured), all as specified and directed by Engineer - in - Charge.
S & F 10 litres capacity, PVC valve less, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets and suitable flush pipe PVC 32mm dia complete all as specified and directed.
M&L for box type steel ventilator with glazing bars dovetailed or welded and with one shop coat of zinc chromate primer complete all as specified.
S & F mild steel as in framed work as in doors or gates of angles or other section etc. complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive for steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing incl MS hinges ,handles ms sheets 0.63 mm thick complete Fe 410-0 all as specified and directed by Engineer - in - Charge.
M&L Cement concrete 1:3:6 type C–1 filling of pressed steel frame and hold fast blocks etc all as specified and directed by Engineer - in - Charge.
Cutting hole in brick wall built in cement mortar exceeding half brick but not exceeding one brick and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4, type B – 1 all as specified and directed by Engineer - in - Charge.
Preparation of new steel surfaces & apply 2 coat of synthetic enamel paint over a coat of red oxide over 10cm in width or girth not otherwise described, complete all as specified.
Supply and fix ceiling fan complete with blades, down rods, electronic regulator and accessories, 230 V, 1400 mm sweep. Min air delivery 245 CFM and service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) of approved colour white/brown/ivory complete three core flexible wire etc from ceiling rose to fan complete all as specified and directed. Make Shall be : Crompton/Bajaj/Havells
Supply and fix electric water heater vertical, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 Ltrs, BEE 5 star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc. etc. Make Shall be : Racold/Bajaj/Havells
Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 50 Ltrs, BEE 5 star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc. etc. Make Shall be Racold/Bajaj/Havells Note for item No 138,139 & 202 :- Rate quoted by the contractor deemed to be inclusive of provision and grouting of suitable size of hold fastener/buzzer bolts , 04 Nos for each Geyser of any wall surface and make good to the disturbed surfaces to match with the existing
S&F in replacement of ceiling rose surface bakelite 63 x50mm three terminals complete all as specified and as directed.
S&F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc as reqd complete all as specified and as directed.
Supply and fix heavy duty single phase, steel body exhaust fan 380 mm sweep, 900 RPM complete with shutter and louvers and exhaust fan shall be fixed with suitable size of buzzer bolt/hold fastener as approved by Engr-in-charge complete all as specified and directed. Make Shall be : Crompton/Bajaj/Havells
Supply and fix heavy duty single phase, steel body exhaust fan 300 mm sweep, 900 RPM complete with shutter and louvers and exhaust fan shall be fixed with suitable size of buzzer bolt/hold fastener as approved by Engr-in-charge complete all as specified and directed. Make Shall be : Crompton/Bajaj/Havells
Supply and fix heavy duty single phase, steel body exhaust fan 450 mm sweep, 900 RPM complete with shutter and louvers and exhaust fan shall be fixed with suitable size of buzzer bolt/hold fastener as approved by Engr-in-charge complete all as specified and directed. Make Shall be : Crompton/Bajaj/Havells
Supply and fixing wall fan 400 mm sweep, 240 Volts, AC, 3 speed, pull cord for speed and oscillaation, aluminium blades for high air thurst complete suitable clamps for wall mounting complete all as specified and directed. Make : Havells, Model No. GIRIK or its equivalent in Bajaj/Havells
Supply and fix "Anti Sucide Fan down rod", 250 mm length, ISI marked approved colour, suitable fo fit any make/brand of ceiling fan complete all as specified and directed.
Taking down carefully copper/aluminium point wiring (light, fan, socket, bell or power) complete including all electrical fittings & fixtures(DBs, submain,cables etc) and making good disturbed surfaces of wall , floor etc and matching wth original colour of wall, complete, all as specified & directed.
M & L for One light / fan point controlled by one way switch replacement of concealed point wiring complete with PVC insulated and unsheathed FRLS cable of 1.5 sqmm (nominal area) with multi stranded copper conductor single core 1100 volts grade in and including rigid PVC conduit ISI marked medium grade not less than 20 mm dia, with MS terminal boxes (not less than 1.6 mm thick) and painted with one coat of red oxide primer all around and two coats of black bituminous paint from out side and two coat of aluminum paint from in side including earth dolly with modular back and cover plate of approved make and colour including 1.5 sqmm multi stranded copper conductor cable of green colour as continuous earth wire with lugs and accesseries and making good disturbed surfaces of walls/floor etc complete all as specified and directed.
All as per item No 148 hereinbefore but One 5 Amp socket outlet on independent board.
All as per item No 148 hereinbefore but One 5 Amp socket outlet on same board.
All as per item No 148 hereinbefore but One bell/buzzer point controlled by one bell push.
All as per item No 148 hereinbefore but One light point controlled by two 2-way switch.
All as per item No 148 hereinbefore but using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed, FRLS cable for 15 Amp socket outlet on independent board including 2.5 sqmm multi stranded copper conductor cable of green colour as continuous earth wire with lugs etc as required complete all as specified and as directed.
S&F in replacement socket outlet 6A-2/3 Pin combined 2 module modular type complete all as specified and directed.
S&F in replacement socket outlet 6A/16A-2/3 pin combined 2 module modular type complete all as specified and directed.
S&F in replacement switch 6 amps modular type one one way complete all as directed.
S&F in replacement switch 16 amps modular type one one way complete all as directed.
S&F in replacement modular type bell push 6 amp one module ISI Marked complete all as specified and directed.
S&F in replacement Bell, DING DONG AC 230 Volts single pole type complete all as specified and as directed.
S&F in replacement of ceiling rose surface bakelite 63 x50mm three terminals complete all as specified and as directed.
S & F in replacement of modular Fan Regulator fan step regulator,120W-2 module ISI Marked complete all as specified as as directed.
S & F In replacement of modular switch 2 way, 6 Amp,1 module ISI Marked complete all as specified and as directed.
S&F in replacement of enviroment friendly indoor decorative 20 Watt LED polycarbonate Batten with opal diffuser including all accessaries all as specified and directed. Make:- 1. Havells Cat No LUMILINEPLUSBS20WLED865SPCSS , 2.Halonix cat no HLB-03-20-CW or equivalent in Crompton.
S&F in replacement of enviroment friendly indoor decorative 10 Watt LED mirror light polycarbonate Batten with opal diffuser including all accessaries all as specified and directed. Make:- 1. Havells Cat No LUMILINEPLUSBS10WLED865SPCSS or equivalent in Halonix and Crompton.
S&F in replacement enviroment friendly,ultra modern,energy saving surface mounted decorative 10 Watt LED bulkhead fitting with pressure die cast aluminium housing ,high efficient LEDs with opal diffuser and IP65 protection all as specified and directed. Make-: 1. Havells cat no- RUGBYNEONFT10WLED860SSYMTOPCOR 2.Halonix cat no HLBH-02-10-CW,Equivalent in Philips,
Supply & fix fans ceiling complete with electronic type regulator and accessories 230 V,1200 mm sweep. BEE 5 star rated complete all as specified and directed.
Supply and fix plastic body storage type geyser of capacity 25 Ltrs 2000 watts 230 V, 1 phase, 50 Hz AC with min 5 star BEE rating and tank made of ultra thick super cold rolled steel plates and viterious enamel coated with heavy duty magnesium anode including all accessories complete all as specified and directed. Make : Havells Cat No. GHWENZTWGG025 or equivalent in Bajaj/crompton
Supply & fix exhaust fans heavy duty 300 mm dia 1400 RPM, 50 Hz 230 volt for domestic use,dynamically balance blade , epoxy powder coated confirm to IS 2312-1967 with ISI marking IP-55 with class B insulation motor including suitable size louver and all fixing accessories such as fastners nut bolts and electric connection with 3 core cable complete all as specified and directed. Make -Havells/crompton/ bajaj.
S & F in replacement of sub main wiring with PVC insulated, fire retardant (FRLS), unsheathed two single core cable 1100 volts grade with stranded copper conductor of size 4.0 sqmm (Nominal area) drawn into existing / new conduit of any size and type / casing-caping with and including one run of 2.5 sqmm multi stranded copper conductor single core PVC insulated, unsheathed cable of green colour as continuous earth wire including lugs etc connected and tested complete all as specified and as directed. Note: (i) New conduit/ casing- caping and accessories shall be measured separately. (ii) Two runs of 4.0 sqmm cable and one run of 2.5 sqmm cable of earth continuity conductor shall be a unit length.
Supply and fixing in repair of Earthing to panel with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to main earth lead 32 x 6 mm galvanised iron strip by means of bolts, nut, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.3 of MES Schedule pt-I 2009, GI earth lead strip protected by GI pipe 40 mm dia light grade and connected to earth test point including excavation in any type of soil,returning filling, disposal of soil, providing charcoal dust and common salt upto top edge of earth plate, construction of PCC pit with RCC cover, funnel, watering pipe of 20mm dia GI light grade and provision of earth test point including testing on completion complete all as specified and as directed.
Supply and fixing in repair TPN DB's 4 way vertical type 415 V, double door suitable for housing of 125 Amps MCCB as main incoming complete all as specified and as directed by Engr-in-charge.
S & F MCCB 100 Amps capacity, 4 pole, 25 KA, fixed thermal and magnetic release complete with extended terminals to be fixed in 4 way TPN DB complete all as specified and as directed by Engr-in-charge.
S&F in replacement MCB SP 5 to 32 Amps, 240 volts curve 'B',breaking capacity 10KA, complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement of bottom lamp holder complete with enviourment friendly LED bulb 12 watt B22 base made of polycabonate including all accessories complete all as specified and as directed by Engr-in-charge.
M&L for concealed point wiring for the following the PVC insulated and unsheathed cable 1.5 sq mm (nominal area) multistranded copper conductor 1100 v FRLS grade single core including PVC conduit medium grade of appropriate size (not less than 25 mm dia) ISI marked concealed in wall and surface on ceiling complete with all accessories and all as specified including 1.5 sq mm PVC insulated unsheather multistranded copper conductor to common earth and connected to earth dolly for following :- For One light/fan point control by one switch. (Note) : 1. The cutting chases shall be finished with cement mortar (1:4) and surface shall be matched with existing surface by using putty, POP etc and applying finishing coat of existing treatment without any extra cost. 2. Rate quoted by the contractor deemed to be included metal flush box of suitable size as required at site and 3 mm thick laminated sheet suitable for mounting of switch and socket etc .
All as per item No 175 hereinbefore but One 3 pin socket outlet, 5 Amps independent.
All as per item No 175 hereinbefore but One 3 pin 5 amps socket outlet on the same board with other switches
All as per item No 175 hereinbefore but wire 2.5 sq mm cable for switch socket outlet 3 pin 15 Amps with 2.5 sq mm as earth continuity conductor. (FOR 15 Amps socket point).
S & F switch piano flush type one way 5 Amps complete all as specified and as directed by Engr-in-charge.
S&F switch piano, flush type single pole 15 Amps complete all as specified and as directed by Engr-in-charge.
S & F socket outlet 2 in 1, 3 pin, 5 Amps complete all as specified and as directed by Engr-in-charge.
S&F socket outlet 2 in 1, 3 pin, 5 and 15 Amps flush type complete all as specified and as directed by Engr-in-charge.
Supply and fix ceiling rose three terminal complete all as specified and as directed by Engr-in-charge.
S&F in replacement of sheet metal enclosure double door concealed suitable for SPN distribution boards when MCB to be used having 200 Amp rated bus bar 4 ways 240 V complete all as specified and as directed .
S&F in replacement of single pole and neutral enclosure with 2 pin and earth plug and socket complete with one single pole MCB 25Amp complete all as specified and as directed.
S&F in replacement MCB SPN 5 to 40 Amps, 240 volts, curve 'B', breaking capacity 10 KA, all as specified.
Supply & fix exhaust fans heavy duty 300 mm dia 1400 RPM, 50 Hz 230 volt for domestic use,dynamically balance blade , epoxy powder coated confirm to IS 2312-1967 with ISI marking IP-55 with class B insulation motor including suitable size louver and all fixing accessories such as fastners nut bolts and electric connection with 3 core cable complete all as specified and directed. Make -Havells/crompton/ bajaj.
S&F in replacement enviroment friendly,ultra modern,energy saving surface mounted decorative 10 Watt LED bulkhead fitting with pressure die cast aluminium housing ,high efficient LEDs with opal diffuser and IP65 protection all as specified and directed. Make-: 1. Havells cat no- RUGBYNEONFT10WLED860SSYMTOPCOR 2.Halonix cat no HLBH-02-10-CW,Equivalent in Philips,
Supply and install hi wall split Type Airconditioner with indoor & outdoor unit complete with Inverter Technology, 3D Airflow, power chill operation,cordless remote control unit and with in built air ioniser, PM 2.5 Filter for better indoor air quality with minimum 5 star rating of capacity 2 TR with precharged CFC free(R32) refrigerant all as specified and directed by Engr-in-Charge. Note Outdoor stand with anchor fastner is included in the item rates. Make : Blue Star/Daikin/Hitachi
Supply and fixing single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB SP 20-32 Amps all as specified and directed.
Supply & installed voltage stabilizer for automatic operation single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V accuracy of 2.5 % and capacity of size 5 KVA all as specified and directed by Engr-in-Charge. Make : V-Guard/Volvo/Luminious
S&F drain pipes 20mm dia heavy duty rigid PVC from indoor unit to exist point as per design including accessories clamps fastner complete all as specified and directed by Engineer in Charge.
S&F additional copper tubing 15.6mm dia with rubber insulation unit suitable for 2 TR Split AC all as specified and directed by Engineer in Charge.
S&F additional copper tubing 6.3mm dia with rubber insulation unit suitable for 2 TR Split AC all as specified and directed by Engineer in Charge.
M&L for wiring for submain wiring with two single core 6 sqmm (nominal area)FRLS insulated copper conductor multi stranded unseathed 1100 volts grade drawn through and including PVC concealed conduit including one 4 sqmm FRLS insulated and unsheathed copper conductor cable as earth wire connected to common earth and dolly including ctting chases in wall with making good the distrubed surfaces with 1:3 cement mortor to match the existing. Note :- 02 Run of 6 sqmm cable, 01 run of 4 sqmm cable and 01 run of PVC conduit shall be measured as one unit.
M&L for sand cushioning with a layer of sand 80 mm thick before laying of cables and 150 mm thick after laying of cables in trenches, or in Existing duct as directed for electric cables for protection incl.consolidation complete all as specified and directed.
M&L for brick protection with sub class B bricks,laid dry flat over electric cables in trenches complete all as specified and directed,
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core all as sepcified and directed.
S&F Copper strip 20 x 3mm as earth lead complete all as specified and directed.
All as per item No 139 above but of horizontal storage type complete all as specified and directed
M/S Rohit Enterprises
akhil enterprises
JAIPAL and BROS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .