| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹26.6 LAccepted-AOC HOSPITAL ROAD P O SONAIMUKH TULARGRAM P I WARD NO 02 SONAI CACHAR ASSAM 788119 | CACHAR | ASSAM | 788119 | 1 | Accepted-AOC L1 | |
| 2 | 2₹32.0 L+₹5.4 L (20.3%)Rejected-Finance | 2 | Rejected-Finance L2 | |
| 3 | Rejected-Technical | - | Rejected-Technical Cancelled technical bid submitted |
Tender Value
₹26.7 L
EMD Value
₹53,300
Closing Date
25 Jan 2020, 11:00 amClosed
Executive Engineer Guwahati Division
O/o the Executive Engineer Guwahati Division Brahmaputra Board
RepairingRenovationofSewageTreatmentPlant
2020_BB_537347_1
BB/GD/1110
Open Tender
Civil Works - Others
Item Rate
45 days
Guwahati
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
FA BB
₹53,300
30 Jan 2020
20 Jan 2020
27 Jan 2020
20 Jan 2020
25 Jan 2020
20 Jan 2020
Amount
Jungle clearance including uprooting of vegitation, grass, brush-wood, sapling and trees not exceeding 300mm girth and disposal of the same outside the periphery and lift upto 1500mm.
Cutting down trees where the building is to beconstructed of girth exceeding 300mm, grubbing up roots, filling pits and levelling off ground lopping branches, trimming and removing to distance beyond 30m and stacking serviceable materials and cleaning site etc. as directed. i) Girth exceeding 300mm but not exceeding 1000mm
Demolishing brickwork including stacking of serviceable materials and disposal of unserviceable materials as directed for all levels.
Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified.Up to a depth of 2.00m below the existing ground level: In ordinary soil
Removal, Collection, Loading, Transportation up to 5.0 KM and unloading of Sludge at Dumpyard and clearing of debris.
Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed.In Sub-structure upto plinth level including dewatering if necessaryIn proportion 1:4
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately).In prop 1 cement: 3 sand :6 coarse aggregate by volume
Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately. Using Mixer MachineIn substructure up to plinth level, Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level.Without using admixture, plasticiser, M20 grade concrete or Prop. 1:1.5:3
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for insitu reinforced concrete and plain concrete work in:Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc:Using 38mm thick plank
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level):From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL:TMT Corrosion resistant steel (CRS) reiforcement bar
15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed:On rough side:In cement mortar 1:4
Supplying and placing plastic cylindrical vertical claused top (PCVC) tank of Sintex / Polycon / Patton make over the stagging with manhole cover with locking and cleaning arrangement including providing pads of size as required for inlet and outlet pipes:i) 2000 Lt capacity (a) Sintex make
Supplying fitting and fixing Pipes with all necessary fittings in exposed or in trenches including trenching and refilling the same etc complete as directed :B) uPVC pipe with uPVC fittings ( Using uPVC high pressure pipe) (Using SUPREME/ PRINCE/ SFMC/ FUSION brand pipe): v) 40 mm diameter
vi) 50 mm diameter
x) 110mm diameter:
xi) 140mm diameter
Providing drain with brick work in cement mortar in proportion 1:5 with half brick thick side walls and 100mm thick C.C (1:3:6) base over one brick flat soling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified.: ii). 300mm wide and average 250mm deep with bed slope 1 in 150 with initial depth of 100mm.:
Neat cement punning
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage.
Providing surface preparation for walls, celling etc.using average 1.50 mm thick plaster of paris including clearing, rubbing with sand paper, filling gaps, depression etc. where necessary, with chalk powder and and plaster of paris paste, making the surface even and smooth complete at all levels as specified and directed
Distempering with dry distemper of approved brand and manufacture(two coats)and of required shade on new wall surface to give an even shade, over and including priming coat of white primer after throughly brushing the surface free from mortar dropings and other foreign matter and including preparing surface even and sand papered smooth.
Distempering with dry distemper of approved brand and manufacture(one coat) and of required shade on old wall surface to give an even shade,after throughly brushing the surface clean of all grease, dirt, loose pieces of scales including preparing surface even and sand papered smooth.
i). Extra over item no (f), (g) and (h) above for distempering every subsequent coat of distempering with dry distemper of approved brand and manufacture.
Supplying and installation of Root Air Blower with necessary fittings, Flow Rate 3.5 KW @ 40 M3/Hr, Motor Capacity 3 HP. (Branded/Certified make)
Supplying and installation of FAB Media with necessary fittings. (Branded/Certified make)
Supplying and installation of Tube Settler Media with necessary fittings. (Branded/Certified make)
Supplying and installation of Fine Bubble Diffuser with necessary fiitngs. (Branded/Certified make)
Supplying and installation of Coarse Bubble Diffuser with necessary fiitngs. (Branded/Certified make)
Supplying and installation of Sludge Transfer Pump of 10 M3/Hr. Capacity with necessary Fittings (Branded/Certified make)
Supplying and installation of Dosing Pump of Technical Specication of 0-50 LPH (Branded/Certified make)
Supplying and installation of FRP based Pressure Sand Filter of capacity 10 M3/Hr and Filter Media of fine and coarse white sand. (Branded/Certified make)
Supplying and installation of FRP based Activated Carbon Filter of capacity 10 M3/Hr and Filter Media of Activated Carbon of 900 IV. (Branded/Certified make)
Supply and installation Filter Feed Pump with Necessary Fittings . Capacity :- 1 HP, ( Branded/Certified make)
Supply and installation of sludge drying bed with necessary fittings
Supply and installation of 2 inch G.I Pipes , UPVC Pipes, Valves,Fittings as actual
Supplying and installation of Panel Board for Sludge Pump, Air Blower, Dosing Pump with necessary electrical connections (Branded/Certified make)
Buildarch Engineers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .