Loading…
Loading…
Tender Value
₹4.1 Cr
EMD Value
₹3.6 L
Closing Date
4 Mar 2026, 11:00 amClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Deposit Work
TENDER
17 conditions · 5 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or V whichever is less, where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderer shall submit requisite information as per Annexure-VIB of GCC, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
a. The tenderer must have successfully completed any of the following during last 07 [seven] years, ending last day of month previous to the one in which tender is invited: Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or One similar work each costing not less than the amount equal to 60% of advertised value of the tender.
Signal and Telecommunication: - Similar single work means carrying out "Execution of any Indoor or Outdoor signaling work (PI/RRI/EI/Automatic block signaling/IBS/IBH/BPAC/LC gate interlocking)". NOTE:- For the following equipment's after award of the contract and before supply of equipment "MoU with RDSO approved firm (if available) or in case not available, MoU with OEM who meets the RDSO specification" covering supply. installation, testing and commissioning of system shall be submitted including after sales support required during the warranty period.
For Engineering work_ Similar work means Any Civil Engineering work.
Electrical TRD_ N/A. Since The value of Electrical TRD portion of work is < 50.00 lakhs.
Electrical (G)_ N/A. Since The value of Electrical (G) portion of work is < 50.00 lakhs.
40 conditions · 9 needing a document upload
Submit your bank details i.e. Name of the Bank along with Bank Branch Code, Account Number, IFSC Code, and PAN Number
As per Correction slip "The tenderers shall submit a copy of certificate stating that all their statements/documents submitted along with bid are true and factual. Standard format of certificate to be submitted by the bidder is enclosed as Annexure-V. In addition to Annexure-V, in case of other than Company/Proprietor firm. Annexure -V(A) shall also be submitted by the each member of a Partnership Firm / Joint Venture (JV) / Hindu Undivided Family (HUH / Limited Liability Partnership (LLP) etc., as the case may be. Non submission of above certificate(s) by the bidder shall result in summarily rejection of his/their bid. It shall be mandatorily incumbent upon the tenderer to identify, state and submit the supporting documents duly self- attested/digitally signed by which they/he is qualifying the Qualifying Criteria mentioned in the Tender document. [Format available in Correction slip].
In case the Tenderer is a Partnership Firm: [i] A notarized copy Partnership deed. [ii] A notarized or registered Power of Attorney (duly registered as per prevailing law) in favour of an individual to sign the tender documents and create liability against the Firm. [iii] PAN / TAN number of Partnership firm (PAN / TAN number in the name of any of the constituent partners shall not be considered).
In case the Tender is a HUF: (i) A copy of notarized affidavit on Stamp Paper declaring that he who is submitting the tender on behalf of HUF is in the position of 'Karta' of Hindu Undivided Family (HUF) and he has the authority, power and consent given by other members to act on behalf of HUF. and (iii) All other documents in terms of explanatory notes in clause 10 of IRGCC 2022.
In case the Tender is a Sole Proprietorship Firm: (i) All other documents in terms of explanatory notes in clause 10 of IRGCC 2022
In case the Tenderer is a Company registered under Companies Act-2013:(i) The copies of MOA (Memorandum of Association) / AOA (Articles of Association) of the company. (ii) A copy of Certificate of Incorporation. (iii) A copy of Authorization/Power of Attorney issued by the Company (backed by the resolution of Board of Directors) in favour of the individual to sign the tender on behalf of the company and create liability against the company. and (iv) Copy of PAN number of the Company.
In case the Tenderer is a LLP Firm registered under LLP Act-2008 (i) a copy of LLP Agreement, (ii) a copy of Certificate of Incorporation. (iii) a copy of Power of Attorney/Authorisation issued by the LLP Firm in favour of the individual to sign the tender on behalf of the LLP Firm and create liability against the Firm. and (iv) copy of PAN number of the LLP Firm.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporation.
ploading of Proforma for Self-Certificate in regard to meeting the Minimum Local Content requirements as per Make in India Policy for Procurement Order Value less than of Rs.10 Crores [as per proforma 17].
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
If the mandatory documents asked for in the E-Tender Document are not submitted along with the tender, the tender submitted otherwise will be treated as incomplete and will not be considered.
The quantities shown in above Schedule are approximate and are as a guide to give the tenderer(s) an idea of quantum of work involved. The Railway reserves the right to increase/ decrease and/or delete or include any of the quantities given above and no extra rate will be allowed on this account.
All rates quoted in the tender shall be deemed to be inclusive of all Taxes royalties payable by the contractor s to the Government or public body or local authority and no additional amount will be paid or claim entertained on this account by the Railway.
It is responsibility of the tenderer that they ensure to see any Corrigendum of the tender to check the corrigendum on the website from time to time.
The works are required to be completed within a period of months as mentioned in website from the date of issue of acceptance letter.
The Tenderer(s) shall keep the offer open for a minimum period of 60 days from the date of opening of the Tender. It is understood that the tender documents have been sold/issued to the Tenderer(s) and the Tenderer(s), is / are permitted to tender in consideration of the stipulation on his / their part that after submitting his / their tender subject to the period being extended further, if required by mutual agreement from time to time, he will not resale from his offer or modify the terms and conditions thereof in a manner not acceptable to the DRM/S&T/Divisional Engineer of SW Railway, Should the tenderer fail to observe or comply with the foregoing stipulation, the amount deposited as Earnest Money for the due performance of the above stipulation, shall be forfeited to the Railway.
If the tender is accepted, the amount of Earnest Money will be retained and adjusted as Security Deposit for the due and faithful fulfilment of the contract. This amount of Security Deposit shall be forfeited, if the Tenderer(s)/Contractor(s) fail to execute the Agreement Bond within 7 days after receipt of notice issued by Railway that such documents are ready or to commence the work within 15 days after receipt of the order to that effect.
Rights of the Railway to Deal with Tender: The authority for the acceptance of the tender will rest with the Railway. It shall not be obligatory on the said authority to accept the lowest tender or any other tender and no Tenderer's(s) shall demand neither any explanation for the cause of rejection of his /their tender nor the Railway to assign reasons for declining to consider or reject any particular tender or tenders.
If the tenderer(s) expires after the submission of his / their tender or after the acceptance of his their tender, the Railway shall deem such tender cancelled. If a partner of a firm expires after the submission of their tender or after the acceptance of their tender, the Railway shall deem such tender as cancelled, unless the firm retains its character.
No post tender correspondence will be permitted and the tender shall be decided based on the documents uploaded with the offer only.
The Tenderer's shall not add any conditions on their own in the tender documents while submitting their offer. Any such conditions if stated and if tender conditions are in violation of the Railway s, may lead to summary rejection of the offer. Railway reserves the right to reject such tenders summarily without assigning any reasons whatsoever.
The responsibility of uploading the correct documents lies with the Tenderer's. In case, the documents uploaded are found manipulated/forged, the offers of such Tenderer's will not be considered and such Tenderer's are liable to be debarred to participate for future works duly forfeiting their Earnest Money and the tenderer/contractor shall have no claims whatsoever in this regard. Railway reserves the right to determine/rescind the contract entered into in case of such false certificates/documents at any stage of the contract treating it as default of the contractor.
Tender Opening will be done any time after the tender closing time. Tenderers are not required to be present during the opening. Railway reserves right to open the tender any time after the time of closing of tender
Before submitting a tender, the tenderer will be deemed to have satisfied himself by actual inspection of the site and locality of the works, that all conditions liable to be encountered during the execution of the works are taken into account and that the rates he enters in the tender forms are adequate and all-inclusive to accord with the provisions in Clause-37 of the Standard General Conditions of Contract for the completion of works to the entire satisfaction of the Engineer.
Railways, being principal employer are required to ensure that the contractors are complying with the provisions of the contract labour (R&A) Act, 1970 and Minimum wages Act, 1948 strictly and arranging prescribed minimum wages to the contractor labourers vide Railway Board letter No. 2016/E(LL)/AT/MW/1Dt. 05.06.2017.
The Tenderer(s) shall quote his / their rates as a percentage above or below the Schedule of Rates of South Western Railway as applicable to Mysore Division except where he/they are required to quote item rates and must tender for all the items shown in the Schedule of approximate quantities attached. The quantities shown in the attached Schedule are given as a guide and are approximate only and are subject to variation according to the needs of the Railway. The Railway does not guarantee work under each item of the Schedule.
Tender cost is not transferable and the amount once paid is non refundable.
Composite Tender of 4 Department works_ 1. S&T work + 2. Electl (TRD) +3. ELectl (G) + 4. Engineering works.
Interlocking of 4 Nos.of LCs [LC- No.4 b/w HAS-ALUR, LC No.7 b/w HAS-ALUR, LC- No.24 b/w ALUR-BLLT & LC-No.83 b/w YDM-NRJ] in Block section in HMRDC section of MYS division where TVU has exceeded 20000 at HMRDC section. (4 LCs-HAS- ALUR-2( LC-4 & LC-7), ALUR-BLLT- LC -24 & YDM-NRJ-LC-83. Composite tender of S&T work, Electrical [TRD], Electrical(G) & Engineering work.
23-SNT-MYS-2025-01
23-SNT-MYS-2025-01
Open
Works - General
9 Months
Dharwad, Karnataka
₹0
₹3.6 L
4 Mar 2026
10 Feb 2026
203 items across 6 schedules · ₹1,28,23,335.3 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| 1 | Excavation of cable trench in all kinds of soil except hard rocky areas including clearing of roots of trees, rocks, bushes etc. to a depth of 1.0 Mtrs and to a width of 0.3 Mtrs. Laying of cables is not included in this schedule. | Metre 10000.00 | — | 34.65 | 3,46,500 |
| 2 | Removing/breaking of existing RCC slabs on the Passenger Platform, trenching to a depth of 0.6m to accommodate the additional cables, replacing the slabs removed after the cables are laid and replastering with cement mortar, refilling the trench by ramming and consolidating it as per the instructions of Railway Representatives at site. Laying of cables is not included in this schedule. [Cement, river sand and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Metre 30.00 | — | 169.95 | 5,098.5 |
| 3 | Excavation of trench to a depth of 1 Mtr. for track crossing of cables, laying of DWC/ RCC pipes with collar/coupling, refilling of trench by ramming and consolidating it as per the instructions of Railway representative at site. During excavation of trench it has to be ensured that the excavated soil does not mix with the ballast available. The depth of 1m trench shall be from the bottom of sleepers for track crossings. Laying of cables is not included in this schedule. (Supply of DWC/RCC pipes with couplers/ collars is not included in this schedule). | Metre 100.00 | — | 208.35 | 20,835 |
| 4 | Excavation of trench to a depth of 1 Mtr. for road crossing of cables, laying of DWC/ RCC pipes with collar/ coupling, refilling of trench by ramming and consolidating it and resurfacing it to the original position. Laying of cables is not included in this schedule.(Supply of DWC/RCC pipes with couplers/ collars is not included in this schedule). | Metre 10.00 | — | 270.83 | 2,708.3 |
| 5 | Provision of GI pipes (50/100mm dia) for cable laying with offset at both ends and with couplings over RCC Bridges/ Drainage/ Culverts with concrete masonry supports of size 300mm x 300 mm x 300 mm at an interval of 2m. The ends of the pipes shall be closed with brick masonry work so that no cable is exposed, The work shall be carried out as per the instructions of Railway representative at site. (Supply of GI pipes with couplings and laying of cables is not included in this schedule.)[Stone jelly of size 20/25mm, bricks, sand, cement and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Metre 300.00 | — | 181.95 | 54,585 |
| 6 | Provision of GI pipes-(50/100mm dia) for cable laying with offset at both ends and with couplings over girder bridges by fixing on suitable MS Clamps at an interval of 2 Mtrs. The ends of the pipes shall be closed with brick masonry work so that no cable is exposed, The work shall be carried out as per the instructions of Railway representative at site. Supply of GI pipes with couplings and laying of cables is not included in this schedule.[MS angles, flats, bolts and nuts for manufacturing fixing clamps, bricks, river sand , cement and all other miscellaneous required for the work shall be supplied by the Contractor]. | Metre 300.00 | — | 215.25 | 64,575 |
| 7 | Provision of GI pipes (50/100mm dia) for cable laying in hard rocky area with off sets at both ends duly supported by concrete blocks of size 300mm x 300 mm x 300 mm at an interval of 2m. The ends of the pipes shall be closed with brick masonry work so that no cable is exposed, The work shall be carried out as per the instructions of Railway representative at site. Supply of GI pipes with couplings and laying of cables is not included in this schedule.[Stone jelly of size 20/25mm, bricks, sand, cement and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Metre 1000.00 | — | 168.08 | 1,68,080 |
| 8 | Laying of signaling/power/telecommunication cables as per cable plan in cable trenches, masonry ducts, RCC Pipes, DWC pipes, GI Pipes etc.(Supply of cables is not included in this schedule). | Metre 18000.00 | — | 9.83 | 1,76,940 |
| 9 | Refilling of cable trench 1m depth by 0.3m width throughout, with earth after laying of cables, and consolidating the trench by ramming and leveling. | Metre 10000.00 | — | 8.33 | 83,300 |
| 10 | Supply of RCC cable markers as per drawing No.CSTE/CN/OFC/1. The lettering on the cable marker shall be "SIG" / "TELE" / "OFC" as per the instructions of Railway representative at site. | Numbers 400.00 | — | 166.29 | 66,516 |
| 11 | Digging of pit to a depth of 800mm of size 300mmX300mm, casting of concrete foundation of size 300mmX300mmX300mm and Placing of RCC cable markers on top of the foundation and refilling the pit and consolidating it by ramming. The cable markers shall be provided at an interval of 20 Mtrs. within station limits and 50 Mtrs. outside station limits throughout the cable route, diversions and also at every track/road/crossing. | Numbers 400.00 | — | 121.43 | 48,572 |
| 12 | Excavation of cable coil pit to a size of 1.5mx1.5m and depth as instructed Railway representative at site, for coiling the cables in rear of relay rooms/ AFTC huts, apparatus cases etc. The work includes coiling the underground cables, and placing closely one layer of country bricks of size approx. 220mm x 100mm x 60mm breadth wise above the cables to cover all the cables in the cable pit, closing and consolidating the pit by ramming and leveling.[Country bricks of size 220mmx100mmx60mm (app) shall be supplied by the Contractor]. | cum 40.00 | — | 513 | 20,520 |
| 13 | Supply of Double walled corrugated pipe - 103.5mm inner dia & 120mm outer dia conforming to specification No. IS 14930(Part 2): 2001 with one coupler for every 6m of pipe as specified in Vol.II of the Tender document. | Metre 300.00 | — | 263.2 | 78,960 |
| 14 | Supply of GI pipes - 50mm dia -3.65mm thick as specified in Vol.II of the Tender document. | Metre 900.00 | — | 343.2 | 3,08,880 |
| 15 | Supply of GI pipes - 100mm dia-4.5mm thick as specified in Vol.II of the Tender document | Metre 100.00 | — | 838.8 | 83,880 |
| 16 | Excavation of pit, casting concrete foundation and erection of apparatus case full size as per Drg. No.SG/CN/02/6 and fixing of 2 Nos. of 'E' type locks, one for the front door and another for the back door, fixing of one hard wood shelf plank 37mm thick and painting the apparatus case inside and outside with one coat of red-oxide and two coats of aluminium paints.(Supply of apparatus case is not included in this schedule).[Foundation bolts & nuts, 'E' type locks, cement, river sand, stone jelly of size 20/25 mm, hardwood plank of 37mm thick, paints, varnish, fixing bolts & nuts and all other miscellaneous materials required for the work shall be supplied by the Contractor.] | Numbers 3.00 | — | 9,875.3 | 29,625.9 |
| 17 | Excavation of pit, casting concrete foundation and erection of apparatus case half size as per Drg, No.SG/CN/02/7, fixing one 'E' type lock for the front door and latching arrangement for the back door, and fixing of one hardwood shelf plank 37mm thick and painting the apparatus case inside and outside with one coat of red-oxide and two coats of aluminium paints.(Supply of apparatus case is not included in this schedule).[Foundation bolts and nuts, cement, 'E' type locks, river sand, stone jelly of size 20/25mm, 37mm hard wood planks, latching arrangements, paints, varnish, fixing bolts & nuts and all other miscellaneous materials required for the work shall be supplied by the Contractor] | Numbers 28.00 | — | 6,966.6 | 1,95,064.8 |
| 18 | Termination of new main/tail cables on the existing terminals/ fuse blocks in apparatus cases/ battery boxes/ CT boxes/ cable termination racks as per approved circuit diagram. The terminal particulars are to be repainted /corrected on the doors of apparatus cases/ battery boxes/ cable termination boxes and FTOT index board as instructed by Railway representative at site. This work includes closing the opening created for entry of new cables in the apparatus cases with masonry brick work and sealing the bottom of the apparatus cases/ cable termination racks with cable compound. [Paints, wire PVC 3/0.75mm and 16/0.2mm copper, sealing compound, bricks, cement, river sand and all other required miscellaneous materials shall be supplied by the contractor]. | Numbers 100.00 | — | 39.78 | 3,978 |
| 19 | Termination of main, tail, Signaling and power cables and internal wiring on terminal/ fuse blocks in new apparatus cases, cable termination boxes and in gate Lodges excluding cable termination rack at relay room. The work includes fixing of all new cables by teakwood clamp on teakwood base plank, fixing of Phynolic synthetic industrial fibre base fine weave cotton fibre board 6mm thick for terminal board to suit each apparatus case, varnishing all teakwood items, fixing of terminals/ fuse blocks on the terminal board, drilling of necessary holes, termination of cables, wiring, identification of cables using aluminium tags with letters punched neatly, as per approved circuit diagram and cable plan, painting of particulars on sleeves and also on the inner side of the doors of apparatus cases. After terminations are over, the side openings of apparatus case foundation shall be closed with brick work, cement plastered, the inter-space filled with river sand up to base level and the bottom surface shall be sealed with sealing compound. (Supply of PBT terminals and Fuse blocks is not covered in this schedule).[Cement, teakwood cable clamp 50mm x 50mm, base planks 100mm x 25mm, Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, PVC/Nylon sleeves, varnish, paints, bolts, nuts and washers, Non-deteriorating type of fuses of various capacities, Aluminium cable tags, sealing compound, country bricks 220mm x 100mm x 60mm, copper bus bars, brass screw, river sand, wire PVC3/0.75mm copper and other miscellaneous materials shall be supplied by the Contractor]. a. Termination on 25/60mm PBT terminals (new location) (Phynolic sheet) | Numbers 800.00 | — | 93.16 | 74,528 |
| 20 | Termination of main, tail, Signaling and power cables and internal wiring on terminal/ fuse blocks in new apparatus cases, cable termination boxes and in gate Lodges excluding cable termination rack at relay room. The work includes fixing of all new cables by teakwood clamp on teakwood base plank, fixing of Phynolic synthetic industrial fibre base fine weave cotton fibre board 6mm thick for terminal board to suit each apparatus case, varnishing all teakwood items, fixing of terminals/ fuse blocks on the terminal board, drilling of necessary holes, termination of cables, wiring, identification of cables using aluminium tags with letters punched neatly, as per approved circuit diagram and cable plan, painting of particulars on sleeves and also on the inner side of the doors of apparatus cases. After terminations are over, the side openings of apparatus case foundation shall be closed with brick work, cement plastered, the inter-space filled with river sand up to base level and the bottom surface shall be sealed with sealing compound. (Supply of PBT terminals and Fuse blocks is not covered in this schedule).[Cement, teakwood cable clamp 50mm x 50mm, base planks 100mm x 25mm, Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, PVC/Nylon sleeves, varnish, paints, bolts, nuts and washers, Non-deteriorating type of fuses of various capacities, Aluminium cable tags, sealing compound, country bricks 220mm x 100mm x 60mm, copper bus bars, brass screw, river sand, wire PVC3/0.75mm copper and other miscellaneous materials shall be supplied by the Contractor]. a. Termination on 25/60mm PBT terminals (new location) (Phynolic sheet) b. Termination on PBT fuse block (new location) (Phynolic sheet) | Numbers 100.00 | — | 113.56 | 11,356 |
| 21 | Termination of main, tail, Signaling and power cables and internal wiring by fixing additional terminals/ fuse blocks on the existing terminal boards of apparatus cases, cable termination boxes etc. The work includes fixing of all new cables by teakwood clamp on teakwood base plank, varnishing all teakwood items, fixing of terminals/ fuse blocks, on the existing terminal boards, drilling of necessary holes, termination of cables, wiring, identification of cables using aluminium tags with letters punched neatly, as per approved circuit diagram and cable plan, painting of particulars on sleeves and also on the inner side of the doors of apparatus cases. After terminations are over, the side openings of apparatus case foundation shall be closed with brick work, cement plastered, the inter-space filled with river sand up to base level and the bottom surface shall be sealed with sealing compound. (Supply of PBT terminals and Fuse blocks is not covered in this schedule).[Cement, teakwood cable clamp 50mm x 50mm, base planks 100mm x 25mm, PVC/Nylon sleeves, varnish, paints, bolts, nuts and washers, Non-deteriorating type of fuses of various capacities, Aluminium cable tags, sealing compound, country bricks 220mm x 100mm x 60mm, copper bus bars, brass screw, river sand, wire PVC3/0.75mm copper and other miscellaneous materials shall be supplied by the Contractor]. a. Termination of cables on 25/60mm PBT terminals (existing location) | Numbers 50.00 | — | 81.68 | 4,084 |
| 22 | Termination of main, tail, Signaling and power cables and internal wiring by fixing additional terminals/ fuse blocks on the existing terminal boards of apparatus cases, cable termination boxes etc. The work includes fixing of all new cables by teakwood clamp on teakwood base plank, varnishing all teakwood items, fixing of terminals/ fuse blocks, on the existing terminal boards, drilling of necessary holes, termination of cables, wiring, identification of cables using aluminium tags with letters punched neatly, as per approved circuit diagram and cable plan, painting of particulars on sleeves and also on the inner side of the doors of apparatus cases. After terminations are over, the side openings of apparatus case foundation shall be closed with brick work, cement plastered, the inter-space filled with river sand up to base level and the bottom surface shall be sealed with sealing compound. (Supply of PBT terminals and Fuse blocks is not covered in this schedule).[Cement, teakwood cable clamp 50mm x 50mm, base planks 100mm x 25mm, PVC/Nylon sleeves, varnish, paints, bolts, nuts and washers, Non-deteriorating type of fuses of various capacities, Aluminium cable tags, sealing compound, country bricks 220mm x 100mm x 60mm, copper bus bars, brass screw, river sand, wire PVC3/0.75mm copper and other miscellaneous materials shall be supplied by the Contractor]. b. Termination of cables on PBT fuse block (existing location) | Numbers 10.00 | — | 102.08 | 1,020.8 |
| 23 | Manufacture a n d s u p p l y of M.S. relay frames of suitable size to hold up to 4/ 8/ 12/ 20 relays as required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit and Point control circuits, fixing of plug boards, relays, resistors and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, wiring and termination as per approved circuit diagram and painting the particulars. (Supply of all types of relays, plug boards, connectors and retaining clips is not covered in this schedule).[Wire PVC copper, 3/0.75mm and 16/0.2mm copper, Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, for fixing resistors and condensers, MS flats 25mm x 6mm brass bolts and nuts, paints, soldering materials, resistors, condensers and all other miscellaneous materials required for the work shall be supplied by the contractor]. a. Wiring of Signal/ point/ LC control circuit (up to 4 relays) | Set 10.00 | — | 2,673.25 | 26,732.5 |
| 24 | Manufacture a n d s u p p l y of M.S. relay frames of suitable size to hold up to 4/ 8/ 12/ 20 relays as required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit and Point control circuits, fixing of plug boards, relays, resistors and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, wiring and termination as per approved circuit diagram and painting the particulars. (Supply of all types of relays, plug boards, connectors and retaining clips is not covered in this schedule).[Wire PVC copper, 3/0.75mm and 16/0.2mm copper, Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, for fixing resistors and condensers, MS flats 25mm x 6mm brass bolts and nuts, paints, soldering materials, resistors, condensers and all other miscellaneous materials required for the work shall be supplied by the contractor b. Wiring of Signal/ Point/ LC control circuit (up to 8 relays) | Set 1.00 | — | 4,739.6 | 4,739.6 |
| 25 | Manufacture a n d s u p p l y of M.S. relay frames of suitable size to hold up to 4/ 8/ 12/ 20 relays as required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit and Point control circuits, fixing of plug boards, relays, resistors and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, wiring and termination as per approved circuit diagram and painting the particulars. (Supply of all types of relays, plug boards, connectors and retaining clips is not covered in this schedule).[Wire PVC copper, 3/0.75mm and 16/0.2mm copper, Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, for fixing resistors and condensers, MS flats 25mm x 6mm brass bolts and nuts, paints, soldering materials, resistors, condensers and all other miscellaneous materials required for the work shall be supplied by the contractor]. c. Wiring of Signal/ Point/ LC control circuit (up to 12 relays) | Set 2.00 | — | 6,137.85 | 12,275.7 |
| 26 | Painting of existing apparatus cases without disturbing the terminations and equipments inside. The work involves scraping of old paint, applying one coat of Red oxide and two coats of Aluminium paint on the inside and outside the apparatus cases, and painting of termination and equipment particulars on the doors of the apparatus cases, as instructed by Railway representative at site. [Aluminium paint, red-oxide and all other miscellaneous materials required for the work shall be supplied by the Contractor]. a. Painting of existing apparatus case - Full size | Numbers 2.00 | — | 1,278.75 | 2,557.5 |
| 27 | Painting of existing apparatus cases without disturbing the terminations and equipments inside. The work involves scraping of old paint, applying one coat of Red oxide and two coats of Aluminium paint on the inside and outside the apparatus cases, and painting of termination and equipment particulars on the doors of the apparatus cases, as instructed by Railway representative at site. [Aluminium paint, red-oxide and all other miscellaneous materials required for the work shall be supplied by the C o n tra c to r ] . b. Painting of existing apparatus case - Half size | Numbers 2.00 | — | 1,223.25 | 2,446.5 |
| 28 | Painting of existing colour light Signals as per standard practice. The work involves scraping of old paint, applying one coat of Red oxide and two coats of Aluminium/ enamel paint on the Signals - complete as instructed by Railway representative at site.[Aluminium paint, red-oxide and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Numbers 2.00 | — | 1,320 | 2,640 |
| 29 | . Alterations to painted termination/ wiring particulars of functions in the existing apparatus cases, cable termination boxes, etc., on the PVC/ nylon sleeves and painting of new nomenclature on the existing signaling gadgets. This work includes carrying out alterations of particulars on the inner side of the doors of apparatus cases, re-numbering of apparatus cases and cable termination boxes.[Paints and all other miscellaneous materials required for the work shall be supplied by the Contractor]. a. Alteration to painting particulars (apparatus case - Full size) | Numbers 2.00 | — | 884.85 | 1,769.7 |
| 30 | Alterations to painted termination/ wiring particulars of functions in the existing apparatus cases, cable termination boxes, etc., on the PVC/ nylon sleeves and painting of new nomenclature on the existing signaling gadgets. This work includes carrying out alterations of particulars on the inner side of the doors of apparatus cases, re-numbering of apparatus cases and cable termination boxes.[Paints and all other miscellaneous materials required for the work shall be supplied by the Contractor]. b. Alteration to painting particulars (apparatus case - half size) | Numbers 2.00 | — | 464.1 | 928.2 |
| 31 | Alterations to painted termination/ wiring particulars of functions in the existing apparatus cases, cable termination boxes, etc., on the PVC/ nylon sleeves and painting of new nomenclature on the existing signaling gadgets. This work includes carrying out alterations of particulars on the inner side of the doors of apparatus cases, re-numbering of apparatus cases and cable termination boxes.[Paints and all other miscellaneous materials required for the work shall be supplied by the Contractor]. c. Alteration to painting particulars (apparatus case- quarter size/ CT box) | Numbers 1.00 | — | 337.45 | 337.45 |
| 32 | Filling earth around location boxes/signal foundations for a width of 0.5m on all sides, up to a level 150mm below the foundation top. This work includes consolidation of earth by watering and ramming. The earth shall be taken from Railway premises as instructed by Railway representative at site. | cum 100.00 | — | 125.02 | 12,502 |
| 33 | Excavation of pit, casting concrete foundation as per Drg.No.SG/CN/02/9 using metallic templates, for erection of colour light signals up to 4 aspects. [Foundation bolts, cement, river sand, stone jelly of size 20/25mm dia and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Numbers 24.00 | — | 5,008.2 | 1,20,196.8 |
| 34 | Erection of surface base, signal pole, mounting of colour light signal up to 4 aspects complete on Signal pole/ Off-set bracket, (for LED/ filament bulbs) with lenses, triple pole lamp holder, filament switching units, CLS transformer, current regulators (whichever is applicable), fixing of ladder with platform complete and concreting of ladder shoe, fixing of number plates, marker board, lens guard, termination of tail cables, wiring of signal unit with PVC wire 3/0.75mm copper, provision of EWS locks, and painting of one coat of red oxide and two coats of aluminium/ enamel paints. When the aspect is fixed on Offset bracket using 'U' bolts and nuts, a through bolt shall be provided by drilling a hole in the signal pole to prevent the offset bracket from sliding down.(Supply of surface base, Offset bracket, CLS pole, CLS aspects complete, ladder with shoes and platform, LED aspects, current regulators, lamp holders, lamps, filament switching unit and CLS transformer is not covered in this schedule).['U' bolts and nuts, through bolts and nuts, cement, stone jelly 20/25mm dia, river sand, Signal Collar Rings, wire PVC 3/0.75mm copper, lens- guard, all fixing bolts and nuts, lead wool, paints PVC/Nylon sleeves, enameled number plates. enameled marker boards, EWS locks, and all other miscellaneous materials for the work shall be supplied by the Contractor]. | Numbers 24.00 | — | 5,501.2 | 1,32,028.8 |
| 35 | Removal of existing CLS units, fixing of new CLS units with LED aspects/ lamps, holders etc., up to four aspects, directly or using off set brackets duly drilling holes on the signal poles, provision of EWS locks wherever necessary, termination of tail cables and wiring using wire PVC3/0.75mm copper and painting of aspect. The new tail cables shall be taken through the signal poles and the unwanted cables duly released.(Supply of CLS unit with LED aspects/ lamps holders, CLS transformers is not included in this schedule.)[EWS locks, Wire PVC 3/0.75mm copper lenses guard, wire netting arrangements, paints and all other miscellaneous materials shall be supplied by the Contractor]. | Numbers 1.00 | — | 5,999.25 | 5,999.25 |
| 36 | Manufacture and supply of Enameled Number plates as per drawing No.TY/08/2008 with fixing arrangements and fixing them on the existing Signals as per the instructions of Railway representative at site.[Enameled number plates with fixing arrangements with bolts and nuts shall be supplied by the Contractor]. | Numbers 40.00 | — | 339 | 13,560 |
| 37 | Supply and provision of Screening arrangement for Signals in RE area as per standard practice. The work comprises of providing MS angle frame and wire mesh in order to avoid close proximity of OHE wires. The work also includes provision of earthing wire using 4 SWG GI wires from the screening arrangement up to surface base as per the instructions of Railway representative at site.[All materials required for this work shall be supplied by the Contractor]. | Numbers 1.00 | — | 1,016.6 | 1,016.6 |
| 38 | Provision of DC Single/ Double rail track circuit to suit RE/ Non-RE areas as per approved signaling plan using Plug-in type track relays. This work includes provision of double bonding, and parallel jumpers, provision of bond wire clips, provision of track lead connections using 2c X 2.5 sq.mm cable, provision of TLD boxes 2 Nos. at Relay end, 2 Nos. at Feed end and 2 No's for parallel jumpers as necessary to suit layouts, for each Track Circuit, and termination of jumpers and tail cables in track lead junction boxes, installation of relays, track feed battery chargers to charge up to 4 cells, track feed resistance, 'B' type choke' and secondary cells - 80 AH capacity in apparatus cases and wiring with wire PVC 3/0.75mm copper. The work also includes painting of track Circuit No. with Feed end/ Relay end details on the TLD boxes. The work also includes provision of insulations for gauge tie plates and nose crossing plates wherever required. (Provision of rail joint insulation is not covered in this schedule. (Uninsulated gauge type plate and nose crossing plate will be supplied by Railways. Supply of track feed battery charger, 'B' type choke, track relays, un- charged secondary cells (2V - 80AH), TLD boxes with stumps, 2cX2.5 sq.mm cable, is not covered in this schedule).[track feed resistance, Gauge tie plate and nose crossing plate insulations, PVC/Nylon bushes for TLD boxes, PVC sleeves, all types of fixing bolts and nuts with spring and flat washers, teakwood stand for fixing track feed resistance, GI bond wire 8 SWG, Channel bond pins, bond wire clips, paints and all other miscellaneous materials shall be supplied by the contractor. Secondary cells-80 AH capacity shall be charged by the contractor through reputed charging agencies]. b. Provision of track circuit in (other than point zone) | Numbers 4.00 | — | 3,862.4 | 15,449.6 |
| 39 | Provision of earth electrodes as per drawing No.SG/SN/02/13 and earthing of metallic sheath and armour of all cables in all apparatus cases, relay room, equipment room, SM's room for block and control, and earthing of all equipments in apparatus cases, power room, relay rack, cable termination rack, control panel, signals, lever frames with MS flat 35mm X 6mm/19c cable (MS flat for closure by areas and MS flat/19c cable combination for farther areas) as per the instructions of Railway representative at site. The work includes painting of earth resistance value on the earth pit. Supply of 19C cable is not covered in the scope of this schedule.[MS flat for earthing 35mm X 6mm, cement, GI earth electrodes, common salt, charcoal, country bricks, river sand, soldering materials and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Numbers 60.00 | — | 1,799 | 1,07,940 |
| 40 | Supply of Colour light Signal pole 140mm dia, 4.6m/ 3.6m tall with necessary inspection as per specification/ drawing/ description enclosed in this document. a. Supply of colour light Signal pole (4.6m) | Numbers 5.00 | — | 3,318 | 16,590 |
| 41 | Supply of Colour light Signal pole 140mm dia, 4.6m/ 3.6m tall with necessary inspection as per specification/ drawing/ description enclosed in this document. b. Supply of colour light Signal pole (3.6m) | Numbers 20.00 | — | 2,974 | 59,480 |
| 42 | Supply of surface base to suit CLS Signal pole 140mm dia with necessary inspection as per specification/ drawing/ description enclosed in this document. | Numbers 25.00 | — | 4,118 | 1,02,950 |
| 43 | Supply of ladder with platform and shoes to suit CLS pole 4.6m/ 3.6m tall, with necessary inspection as per specification/ drawing/ description enclosed in this d o c u m e n t . a. Supply of ladder with platform and shoes for 4.6m CLS pole | Numbers 5.00 | — | 3,203 | 16,015 |
| 44 | Supply of ladder with platform and shoes to suit CLS pole 4.6m/ 3.6m tall, with necessary inspection as per specification/ drawing/ description enclosed in this document. b. Supply of ladder with platform and shoes for 3.6m CLS pole | Numbers 20.00 | — | 3,089 | 61,780 |
| 45 | Supply of Colour Light Signal Multi Unit type - complete for 4/ 3/ 2 aspect with mounting socket, with necessary inspection as per specification/ drawing/ description enclosed in this document. a. Supply of colour light Signal unit - 4 aspect | Numbers 1.00 | — | 12,584 | 12,584 |
| 46 | Supply of Colour Light Signal Multi Unit type - complete for 4/ 3/ 2 aspect with mounting socket, with necessary inspection as per specification/ drawing/ description enclosed in this document b. Supply of colour light Signal unit - 3 aspect | Numbers 8.00 | — | 10,296 | 82,368 |
| 47 | Supply of Colour Light Signal Multi Unit type - complete for 4/ 3/ 2 aspect with mounting socket, with necessary inspection as per specification/ drawing/ description enclosed in this document. c. Supply of colour light Signal unit - 2 aspect | Numbers 16.00 | — | 8,580 | 1,37,280 |
| 48 | Supply of PBT terminals 25mm/ 60mm centre and PBT Fuse blocks with necessary inspection as per specification/ drawing/ description enclosed in this document. a. Supply of PBT terminal - 25mm centre | Numbers 1000.00 | — | 44 | 44,000 |
| 49 | Supply of PBT terminals 25mm/ 60mm centre and PBT Fuse blocks with necessary inspection as per specification/ drawing/ description enclosed in this document. b. Supply of PBT terminal - 60mm centre | Numbers 500.00 | — | 60 | 30,000 |
| 50 | Supply of PBT terminals 25mm/ 60mm centre and PBT Fuse blocks with necessary inspection as per specification/ drawing/ description enclosed in this document. c. Supply of PBT fuse block (without ND fuse) | Numbers 200.00 | — | 82 | 16,400 |
| 51 | Supply of Low maintenance secondary cells of the following capacities with necessary inspection as per specification/ drawing/ description enclosed in this document. b. Supply of secondary cells- 2V-80AH capacity | Numbers 12.00 | — | 2,077 | 24,924 |
| 52 | Supply of apparatus cases (full/ half/ quarter size) to suit Southern Railway standard with necessary inspection as per specification/ drawing/ description enclosed in this document: a. Supply of apparatus case - Full size | Numbers 3.00 | — | 12,012 | 36,036 |
| 53 | Supply of apparatus cases (full/ half/ quarter size) to suit Southern Railway standard with necessary inspection as per specification/ drawing/ description enclosed in this document: a. Supply of apparatus case - Full size b. Supply of apparatus case - Half size | Numbers 32.00 | — | 8,580 | 2,74,560 |
| 54 | Supply of QTA2 - track relays with plug boards, connectors and retaining clips with necessary inspection as per specification/ drawing/ description enclosed in this document. | Numbers 5.00 | — | 2,524 | 12,620 |
| 55 | Supply of QSPA1 type relays with plug boards, connectors and retaining clips with necessary inspection as per specification/ drawing/ description enclosed in this document. | Numbers 5.00 | — | 3,897 | 19,485 |
| 56 | Supply of Electric key transmitter - rotary type of required ward Nos. with keys, with necessary inspection as per specification/ drawing/ description enclosed in this document. | Numbers 16.00 | — | 4,279 | 68,464 |
| 57 | Supply of 'A' type foundation made of cast iron as per Drg No.CWM.00902, and as per specification/ drawing/ description enclosed in this document, with necessary inspection. | Numbers 8.00 | — | 5,491 | 43,928 |
| 58 | Supply of track feed battery charger as per specification/ description enclosed in this document. | Numbers 5.00 | — | 2,460 | 12,300 |
| 59 | Supply of 'B type choke as per specification/ description enclosed in this document. | Numbers 5.00 | — | 2,076 | 10,380 |
| 60 | Fixing of plug boards, 50 way terminal blocks with 2BA terminals, and wiring of relays as per the approved circuit diagram using wire PVC 16/0.2mm copper. Suitable wire supporting tray with cover made of PVC shall be provided horizontally and vertically in the relay racks. While running the wires on the aluminium ladder proper care shall be taken to provide smooth materials like rubber beading in the openings on Phynolic sheets, to avoid damage to wires. The work also includes wiring of contacts for data logger and terminating them in tag blocks, provision of relay index board(Supply of relay, plug board, connector and retaining clip is not covered in this schedule).[Wire PVC 16/0.2mm copper, tag blocks, 2BA terminals, hard wood plank of size 600mmx 900mmx25mm with decolum finish, MS angles of size 25mmX25mmX6mm, relay fixing bolts and nuts, teakwood plank 25mm thick for fixing resistor and condenser, phynolic sheet 6mm thick of size 1200mmX1800mm with aluminium grooved channel frame for relay index board, paints, soldering materials, bunching thread, wire wound resistance, condenser, wire supporting tray with cover of suitable size made of PVC, paint, varnish and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Per 150.00 Relay | — | 565.27 | 84,790.5 |
| 61 | Fixing of additional plug boards, 50 ways terminal blocks and wiring of additional relays as per the approved circuit diagram using wire PVC 16/0.2mm copper. Additional wire supporting tray with cover made of PVC shall be provided wherever required. Alterations to Relay particulars shall be incorporated in the relay Index board.(Supply of relays, plug boards, connectors and retaining clips and 50 way terminal boards is not covered in this schedule).[Wire PVC 16/0.2mm copper, 2 BA terminals, teakwood plank 25mm thick for fixing resistors and condensers, soldering materials, bunching thread, wire wound resistance, condenser, wire supporting tray with cover of suitable size made of PVC, paint, varnish and all other miscellaneous materials required for the work shall be supplied by the Contractor | Per 2.00 Relay | — | 392.7 | 785.4 |
| 62 | Carrying out alterations to the existing relays in the relay racks/apparatus cases as per the approved circuit diagram using wire PVC 16/0.2mm copper. The work includes releasing the unwanted wires carefully without disturbing the existing wiring.[Wire PVC 16/0.2mm copper, soldering materials, bunching threads, condensers, resistances and teakwood plank for fixing them and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Per 30.00 Relay | — | 376.04 | 11,281.2 |
| 63 | Charging and installation of secondary cells of the following capacities, on existing battery stand/ RCC slabs in the battery room. The work involves charging of secondary cells, fixing and connecting the batteries with strips, manufacture and fixing of teakwood terminal box, termination of cables, wiring with suitable wire PVC 7/1.40mm and 3/0.75mm copper through suitable PVC pipes/ casing properly clamped, provision of battery particulars board made of phynolic sheet 6mm thick of size 900mm x 1200mm with Aluminium grooved channel frame in the relay room. The particulars shall be digitally using good quality laminated gum sheet, provision of hydrometer -1 No. on a stand and battery tester-1 No. Charging of secondary cells shall be done by the contractor through reputed agencies(Supply of secondary cells is not covered in this schedule).[Teakwood plank 25mm thick for manufacturing termination box with locking facility, wire PVC 7/1.4mm and 3/0.75mm copper, anti- corrosive paint, varnish, PVC pipes/ casing, and all other miscellaneous materials required for this work shall be supplied by the contractor]. d. Installation of 2V- 40/80AH on existing stand/slabs | Numbers 15.00 | — | 382.58 | 5,738.7 |
| 64 | Supply and provision of Rubber mat of not less than 6mm thick and with an insulation to withstand 650VAC, on the floor of relay room etc at places as indicated by railway representative at site. | Square 500.00 Foot | — | 78.3 | 39,150 |
| 65 | Excavation of pit, concreting 'A' type foundation and fixing ground lever frames single/double as per Drg.No.SG/CN/02/11 complete with ground connection. The work includes concreting of 'A' type foundations and fixing of HP lock and connecting the ground lever frame with the HP lock using MS rod as instructed by Railway representative at site. (Supply of ground lever frames, hand plunger locks and 'A' type foundations is not covered in this schedule). [Cement, river sand, stone jelly of size 20/25mm, fixing bolts and nuts with washers and all other miscellaneous materials shall be supplied by the Contractor]. | Numbers 8.00 | — | 4,531.35 | 36,250.8 |
| 66 | Interlocking of level crossing gate with Lifting Barrier: This work consists cutting of notches on the drum of the winch, , fixing and levelling of trestles, rod roller assembly, levelling and concreting of 'A' type foundations, fixing of rod diversion cranks, vertical cranks, running of rods (app. 30mtrs.) and connecting them to lever tail at one end and boom locking arrangement at the other end, and painting as per standard practice. The work also includes fixing of wiring of one limit switch for each boom as per the instructions of Railway representative at site. (Supply of HP locks, rods, 'A' type foundations, trestles, segments, rod roller assembly complete and cranks is not covered in this schedule). [cement, river sand, stone jelly of size 20/25mm dia, coal bengal, paints, all types of bolts & nuts and all other miscellaneous materials shall be suuplied by the Contractor]. | Numbers 4.00 | — | 12,370.05 | 49,480.2 |
| 67 | Testing and commissioning the entire signalling installations jointly with the Railway representative at site at the stations/ LC gates covered under various schedules of the Contract, and ensuring that all the signalling gears are installed and adjusted as per the existing rules. The work also involves supply of required number of bound registers with good quality papers with all updated details of cable meggering, relays, batteries, block joints, route cancellation, relay room key entries, block instrument key, earth resistance etc., and handing over to Railways. (Supply of 'As mades' is not covered in this schedule). c. Testing and commissioning of LC gates | LC Gate 4.00 | — | 8,128.5 | 32,514 |
| 68 | Supply and provision of E type lock with key for fixing the same in LC/HP/FP Locks/SM slides and painting as per standard practice and instructions of Railway representative at site. (Supply of E type Locks, Keys, Paints, all types of screws, bolts & Nuts and all other miscellaneous materials shall be supplied by the Contractor). | Numbers 4.00 | — | 1,266 | 5,064 |
| 69 | Releasing of existing apparatus cases (Full/ Half/ Quarter size) without damage after releasing t h e shelf planks, Terminal blocks, Fuse B l o c k s , Te r m i n a l Boards, Relays of all types EKTs, Secondary Cells, power equipments, 'E' type locks, etc., and breaking the concrete foundation. After releasing, the resultant pits are to be closed and consolidated by ramming and levelling. The released materials shall be accounted and stacked at a place as instructed by Railway representative at site. | Numbers 2.00 | — | 1,625.25 | 3,250.5 |
| 70 | DISmantling and releasing of existing Colour light Signals complete (upto 4 aspects) with or without Route Indicators, calling on signals, shunt signals etc., carefully without any damage to the gadgets, accounting and stacking them neatly at a place as instructed by Railway representative at site. The w ork includes breaking the concrete foundation, closing t h e resultant p i t and resurfacing it by ramming and levelling. Dismantling and releasing of existing Colour light Signals complete (upto 4 aspects) with or without Route Indicators, calling on signals, shunt signals etc., carefully without any damage to the gadgets, accounting and stacking them neatly at a place as instructed by Railway representative at site. The work includes breaking the concrete foundation, closing the resultant pit and resurfacing it by ramming and levelling. Dismantling and releasing of existing Colour light Signals complete (upto 4 aspects) with or without Route Indicators, calling on signals, shunt signals etc., carefully without any damage to the gadgets, accounting and stacking them neatly at a place as instructed by Railway representative at site. The work includes breaking the concrete foundation, closing the resultant pit and resurfacing it by ramming and levelling. Dismantling and releasing of existing Colour light Signals complete (upto 4 aspects) with or without Route Indicators, calling on signals, shunt sign | Numbers 1.00 | — | 1,666.5 | 1,666.5 |
| 71 | Transportation of Signalling materials by road as per the instructions of Railway representative at site. The work also includes loading and unloading of the materials. a. Transportation upto 100 Kms. | MT-Km 10000.00 | — | 12.3 | 1,23,000 |
| 72 | Transportation of Signalling materials by road as per the instructions of Railway representative at site. The work also includes loading and unloading of the materials. b. Transportation more than 100 Kms. | MT-Km 20000.00 | — | 7.52 | 1,50,400 |
| Schedule total | ₹39,38,243.3 | ||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
InspectionofSafety-CriticalSignallingItemsbyRDSOdt260925.pdf
JPO_Digging.pdf
LETTERTOZONESclarificationNDKR1_RDKR1CKT15.07.2025.pdf
Chapter_4B_TechnicalGuidelines1.pdf
ConservancyChargesdt07092021.pdf
ProformDetails.pdf
Localcontents_lessthan10crores1.pdf
GCC_April-2022.pdf
ACS1to10_compressed.pdf
IPS-LCgate-4LC.pdf
TB-TRDHMRDC4LCs.pdf
TBforComposittender4NoofLCunderHMRDCsection1.pdf
TenderBook_Engineering_4LCs.pdf
NSitemapprovalBorewell.pdf
GADandSoilinvestigationapproval_Engg_1.pdf
specialconditions_Engg.pdf
similarnatureofworklatestdt21122020_Engineeing.pdf
TANonEarthingBondingSurgeandLightningprotection1.pdf
TechnicalSpecificationSAndT_4LCs.pdf
TBook_4LCsHMRDC_SAndT_2.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .