| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.3 LAccepted-AOC | L1 | Accepted-AOC Ok | |
| 2 | L2₹14.3 L+₹35,849 (2.58%)Rejected-AOC | L2 | Rejected-AOC Ok |
Tender Value
₹14.5 L
EMD Value
₹28,960
Closing Date
30 Mar 2020, 6:00 pmClosed
GE Palampur
Holta Camp Palampur kangra
SPECIAL REPAIR TO BLDG NO T-22 BHOJPUR LINE AT PALAMPUR MIL STN
2020_MES_330478_1
GEP-66(Token)/2019-20
Open Tender
Civil Works
Item Rate
180 days
Palampur
As per tender documents
8 documents required · 8 mandatory
₹500
Yes
GE Palampur
₹28,960
Yes
29 Jun 2020
2 Mar 2020
1 Apr 2020
2 Mar 2020
30 Mar 2020
16 Mar 2020
Amount
SCHEDULE 'A' PART-I: Taking down chowkats or frames with shutters (without taking of shutters from the frame) n.exc 1.5 Sqm each complete
Taking down chowkats or frames with shutters (without taking of shutters from the frame) exc 1.5 but n.exc 4 Sqm each complete.
Taking down cement plaster on brick work or stone walls, etc including wall tiles, raking out joints, hacking for key, scrubbing down with water, etc.
Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level), complete all as specified.
Dismantling plain or corrugated steel sheeting any gauge thickness including Nanital or similar type pattern roof coverings
Dismantling of ceiling boards (fibre, pulp, insulation etc) or insulation boards /slabs /blankets, any thickness, including cover fillets etc complete all as specified and directed.
Dismantling unframed work timber scantlings 40 sqcm & over in section , in any position complete all as specified and directed.
Dismantling unframed work in fillets, rails, posts, rafters, purlins, scantling etc under 40 sqcm in section complete all as specified.
Demolition of stone/boulders or brick masonry built in cement mortar incl all quoins, arches, pillars, etc but excl ashler facing , dresses, stone work and precast concrete articles etc, complete all as specified.
Plain cement concrete M-10, nominal mix, type C-1, using 20mm graded mechanically crushed stone aggregate, 75mm thick as in plinth protection etc., surface finished even and smooth without using extra cement and laid to a slope of 1 in 24 in alternate panels n.exc. 1.20 Sqm each, 12mm wide and 5 cms deep joints shall be formed between the bays and shall be filled with mastic filling comprising a mixture of one part of heated blown bitumen VG-10 and two parts of heated coarse sand (by volume), all as specified & directed. Note:- The unit rate include for use of form work (straight or curved).
Plain cement concrete, M-15 type B-1 (using 20 mm graded crushed stone aggregate) as in surface channels or drains complete, all as specified.
M&L for 25mm thick PCC 1:2:4, type B-O (using 12.5mm graded crushed stone aggregate) as in floors finished rough to receive floor finishes, complete all as specified.
M&L for Non skid ceremic coloured tiles 7 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match, complete all as specified.
M&L for glazed ceramic coloured tiles 300 mm x 200 mm x 5 to 6 mm thick as in vertical surfaces such as skirting, dado etc set and jointed in neat cement slurry pointed in white or coloured cement to match over and includind 10 mm thick rendering in cement mortar 1:4 to receive tiles, complete all as specified.
S&F roof trusses (framed), trussed, purlins, crane gantries, rails and fastening and heavy brackets framing (beam, tee, angle, channel or flat sections)incl distance pieces, cleats, etc confirming to Fe-290(Grade E-165) complete all as specified .
Excavation in post holes (or similar holes) in any type of soil, n exc 0.5 cum getting out , returning , filling, in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm , complete all as specified
M&L PCC type C-2 1:3:6 (40mm graded aggregate) cement concrete in foundation, filling and mass concrete
S&F for steel work in tubular trusses including special shaped washer etc, complete using ERW or induction butt welded tubes confirming to IS 1161-1979 grade St-240, complete all as specified.
S&F for Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified, complete all as specified.
S&F for Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified, complete all as specified.
M&L for 15mm thick rendering on fair faces to brick work or stone masonry surface in CM 1:6 finished the surface even and smooth (without using extra cement on internal wall surface, complete all as specified.
M&L for 15mm thick rendering on fair faces to brick work or stone masonry surface in CM 1:4 finished the surface even and smooth (without using extra cement on external wall surface, complete all as specified.
M&L for PCC type B1, 1:2:4 (using 20mm graded stone aggregate) as in hold fasts / bed blocks / coping etc, all as specified.
S&F for aluminium anodised powder coated chowkhats frames for doors, windows, ventilators, partition with one or more rebates including joining cleat for fixing etc, complete all as specified.
5.5 mm thick ordinary quality sheet glass fixed to aluminium frame of partition etc fixed with rubber gasket & aluminium powder coated snap beading etc, complete all as specified.
S&F in repair aluminium anodised powder coated door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading screws etc, complete all as specified.
S&F in repair aluminium anodised powder coated window and ventilator shutters(sliding type) fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc, complete all as specified.
S&F in repair brass 4 Levers Mortice lock, vertical type size 100mm, complete all as specified.
M&L in repair double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed, complete all as specified.
S&F in repair aluminium (Extruded section) door closer hydraulically regulated, designation No. 3 universal type suitable for door shutter of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified.
S&F for 6mm thick E-board (Classic) false ceiling of size 610 x 610 mm fixed with aluminium snap grid frame work of same size as aluminium tee of size 25x25x1.50mm as main runner, 25x25x1.25mm thick aluminium tee as cross runner and aluminium angle of size 25x25x1.25 mm at the perimeter, including GI adjustable suspender of required length, including dismantling of old ceiling, complete all as specified.
Brickwork with subclass `B' bricks, straight or curved on plan exc 6m mean radius, built in CM 1:4 complete all as specified and directed.
Preparing of newly plastered wall surface and applying two coat oil bound distemper on newly plastered surfaces, complete all as specified
Preparation to old plastered/unplastered wall surfaces incl brooming down or steel wire brushing , scraping down, smooke soot, moulds, moss & efflorescent salts and trading oil and greasy spots etc and applying two coats of oil bound distemper complete all as specified and directed.
Preparetion of newly steel surfaces and applying two coats of synthetic enamel over a coat of red oxide primer complete all as specified and directed.
S&F 5mm thick plain colour PVC sheet in strips & channel feathered at edges for fixing on solid PVC Wall lining , Insulated PVC Wall lining, and solid PVC partitions inclusive of solvent cement and fixing at site as per specifications and drawing
SCHEDULE 'A' PART-II: Taking down carefully unserviceable Aluminium/Copper point wiring complete (light, fan socket, bell or power) with fitting such as switches, ceiling rose lamp holder, regulators, sockets, light fittings etc. and keeping in safe custody for taking credit (credit for above item should be made as per condition seperatly) and making good disturbed surfaces of walls, floor etc complete all as specified.
Taking down unservecable TPN DB with MCB's of any make/capacity complete all as specified.
Point wiring for one light point controlled by one switch 5 Amp one way using cable 1.5 sqmm for phase and neutral and 1.5 sqmm for earthing and connected to common earth duly using FRLS PVC insulated unsheathed multistrand copper conductor cable with proper colour coding with conceled fitting and incl PVC conduit 25mm dia having wall thickness not less than 2mm with sunk cast iron/ pressed steel terminal boxes made out of 1.2mm thick sheet including incl suitable modular PVC sunken box for fix switch and socket incl cover plate for required module for mounting switches socket etc making connection and making good the disturbed surfaces to match with the existing specification complete all as specified.
All as per the description of serial item No 39 here-in-before but for one fan point/Exhaust fan controlled by one, one way switch and regulator complete all as specified.
All as per the description of serial item No 39 here-in-before but for one bell point controlled by one, one bell push complete all as specified.
All as per the description of serial item No 39 here-in-before but for 3 pin socket outlet 5 amp on independent board complete all as specified.
All as per the description of serial item No 39 here-in-before but for 3 pin socket outlet 5 amp on same board complete all as specified.
All as per the description of serial item No 39 here-in-before but for 3 pin socket outlet 15 amp independent board with cable of size 2.5sqmm in point wiring and 1.5sqmm in contionous earth wire complete all as specified.
Switch modular single pole one way 6 amp complete all as specfied.
Socket modular 5 pin 6 Amp complete all as specfied.
Switch modular single pole one way 16 amp complete all as specfied.
Socket modular 3 pin, 6/16 amp complete all as specfied.
Modular Bell push single pole one way 6 amp 240 volt complete all as specfied.
S&F musical door bell AC 230 Volt single phase complete all as specified.
Modular fan step regulator fan step type 240 volt 120 watt complete all as specfied.
S&F of ceiling rose surface type 65mm x 50mm 3 terminal complete all as specified and directed
Supply and fixing LED box type tube light fitting suitable for 1x20W 4 FT complete with LED tube rod, fixed complete to wall/ceiling and PVC round/square block (02 Nos) of suitable size etc provided complete with flexible pipe of suitable size complete all as specified and directed.
Supply and fix decorative wall light fixture made up of Polycarbonate incl LED lamp 10 watt complete complete incl two core wire connection from ceiling rose to connector with flexible pipe of suitable size of all complete all as specified.
S&F Pressure die cast housing with epoxy power coated dark graphite grey colour finish prismatic polycarbonate cover with individual LED lenses. with 30 W LEDs as light source complete all as specified.
S&F street light bracket made out of 32 mm dia GI light grade tubing not less than 1.5 Mtr long bend to shape including pole clamps made out of 40 x 5 iron strip and nut bolts and washers, complete all as specified.
Taking down old unserviceable light fittings/Bulkhead fittings of any type and model complete and making good the disturbed surface complete all as specified.
Supply and fix distribution board iron clad TPN DB double door with IP-43 protection 415 V 3 Phase 50 HZ 4 Way complete with appropriate size of copper busbar and neutral link complete and including cutting chasing to wall for fixiing DB and making good the disturbed wall to match with existing surface complete all as specified.
Supply and fix MCB TPN 63 Amps 10 KA 230 volts 'C' series complete all as specified.
Supply and fix MCB SP 6 to 32 Amps 10 KA 230 volts "C" series complete all as specified and directed.
Earthing with galvanized steel earth plate electrode 60cmx60cmx6mm thick, buried directly in ground (earth pit less than 2.25 mtr deep below normal ground level) with top edge of the earth plate not less than 1.5 mtr deep below normal ground level, connected to 4mm dia galvanized iron wire as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel complete with 15mm dia light grade protection pipe, 20mm dia GI light grade watering pipe with funnel including charcoal dust, salt, PCC 1:2:4 in pit with precast RCC M-15 cover reinforced with XPM not less then 4.00 Kg per sqm including necessary earth work in any type of soil, removal of surplus soil to a distance not exc 50m, returning filling in complete as shown in electrical plate No 3 of SSR Part-I (2009), and connected to earthing test point all as specified or indicated, including testing on completion. NOTE: The rates for earthing includes the cost of earth lead and protection pipe upto 7.50m length.
Disconnecting/Taking down ceiling fan of size 1200/1400mm sweep removing and cleaning the dust properly, painting with same colour good quality synthetic enemelled paint after preparing surface for painting oiling and greasing of bearing incl refixing and making the connection and testing complete all as specified.
Taking down unservicible U/G cable after disconnecting from pole and Supply & laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sqmm 4 core complete all as specified.
Excavation in trenches n exc 1.5 m wide and n exc 1.5 mtr in depth for foundation laying of under ground cable erecting of pole stay not exc 10 sqm on plain and not exc 1.5 m depth and getting out in any type of soil complete all as specified.
Returning, filling in (soil ) including spreading, levelling, watering and well ramming in layers not exc 25 cm in any type of soil complete all as specified.
Removal of excavated material (soil) to a distance n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified.
Sand cushioning to underground cable as per clause No 19.75 of SSR Part-I laid with a layer of sand 8 cm before laying the cable and 15 cm after laying the cable. The top layer of 15cm shall be punned to 10 cm (total 18 cm) complete all as specified.
Sub class ‘B’ brick old size protection cover laid dry flat transversally along the length of cable on cushioning with width equal to the length of brick complete all as specified.
Material and labour for GI tubing (light grade) with all fitting laid in trenches or along pole/bldg or under road crossing and protection pipe or fixed alongwith wall/pole with necessary clamp nut bolt and washer bore of pipe 40mm complete all as specified.
BHARDWAJ BUILDERS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .