| 1 | L1₹38.4 LAccepted-AOC | L1 | Accepted-AOC Being a lowest | |
| 2 | L2₹41.7 L+₹2.3 L (5.79%)Rejected-Finance | L2 | Rejected-Finance Not a lowest tender | |
| 3 | L3₹46.8 L+₹7.4 L (18.7%)Rejected-Finance | L3 | Rejected-Finance Not a lowest tender |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
29 May 2023, 6:00 pmClosed
GE AF TA Gwalior
GE AF TA Gwalior 474020
REPAIR/MAINT OF PLINTH PROTECTION, HARD STANDING, JOINERY, PLASTERING, INTERNAL WIRING AND FLAME PROOF LIGHTING FOR WSA AND OTHER OTM BLDGS IN TECH AREA AT AF STN GWALIOR
2023_MES_590980_1
8900/1460/GWL/E8
Open Tender
Civil Works
Item Rate
330 days
AF STN Gwalior
As per tender documents
8 documents required · 8 mandatory
₹500
GE AF TA Gwalior
₹90,000
Yes
22 Jun 2023
24 Apr 2023
6 Jun 2023
24 Apr 2023
29 May 2023
15 May 2023
Amount
Demolition of cement concrete ( unreinforced) including floor tiles, screed bed at ground floors and pavings n. exc 15 cm thick below or above ground level and removing the demolished material to a distance exc 500 m but not exceeding 1.5 km and depositing where directed, complete all as specified and directed .
M&L for 75 mm thick plain cement concrete (1:3:6) type C2, using 20 mm graded stone aggregate as in Plinth protection and finishing the surface even & fair complete all as specified and directed.
M&L for 100 mm thick plain cement concrete (1:2:4) type B2, using 40 mm graded stone aggregate as in pavings/hard standings and finishing cement concrete surface even & fair,laid in alternate panels complete all as specified and directed.
M&L for 75mm thick plain cement concrete (1:3:6) type C2, using 40mm graded stone aggregate as in sub base complete all as specified and directed.
Demolition stone slabs , tiles , paver of any description or thickness in floors, walls laid bedded and pointed in any mortar complete all as specified and directed.
M&L for machine pressed precast concrete interlocking paver block Glossy finish any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade with grey cement with pigment complete all as specified and directed.(Make:- ISI Marked as approved by GE)
M&L sand filling under floors or in foundations including watering and consolidation all as specified and directed.
M & L for 25 mm thick cement concrete 1:2:4 type B-0 ( using 12.5mm graded stone aggregate) as in sub base complete all as specified and directed.
M&L for 15 mm thick screed bed or bedding in layer of cement mortar for 1:4 for laying floor finishes complete all as specified and directed.
M&L for 10 to 12mm thick Endura desiner tiles of size not exceeding 0.16 Sqm any colour and shape with grey cement and pigment set, jointed and pointed in neat cement slurry as in floors complete all as specified and as directed.(Make :- DUROTA/JOHNSON/ORIENT/SOMANY)
M&L for Vitrified Ceramic tiles 8 to 9mm thick (square / rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed
All as per item no. 11 here-in-before but as in skirting/dado including jointed in neat cement slurry and pointed in white or coloured cement to match the coloured tiles including 10mm thick cement plaster 1:4 as backing coat complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified.
M&L for joint free coloured glazed ceramic tiles in vertical surface 450x300x7mm thick etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the tiles including 10mm thick rendering cm 1:4 for back coat all as specified and as directed.
M&L for providing cement concrete (1:2:4) Type B0 (using 12.5mm & 20mm graded stone aggregate) as in kerbs, haunching coping & flooring including necessary formwork rounded or chamfered angles all as specified and directed.
S&F in repair for 2 mm thick PVC flooring, laminated plain coloured, marbled mosaic or mottled finish, laid with approved rubber based adhesive in floors including all cutting and waste and work in all position, complete all as specified and directed .
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or steel, concrete or brick surrounds, glazed with putty or fixed with beads etc complete all as specified and directed .
S&F 3mm thick sheet glass, ordinary quality and glazing with oil putty in square n exc 0.50 sqm in each pane complete all as specified and directed .
S&F 10mm thick toughned glass as in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holes required complete all as specified and directed .
Demolition of brick work or stone masonry of any description and in any position built in cement mortar including all quoins, arches pillar etc including disposal of rubbish complete all as specified and directed.
M&L brick work with sub class 'B' bricks straight or curved on plan exc 6 M mean radius built in CM (1:6) complete all as specified and directed.
Description same all as per item No 21 above but, except brick using old retrieved bricks obtained from demolition in serviceable conditions complete all as specified and directed.
Taking down cement plaster on brick surface or stone wall etc including racking out joints hacking for key, scrubbing down with water etc complete all as specified and directed .
M&L for 15mm thick rendering other than fare face of brick/stone masonry walls in CM 1:6 finished complete all as specified and directed by Engr-in-Charge
M&L for 15 mm thick rendering on fair face of brick walls in CM (1:4) surface finished even and fair complete all as specified and directed.
M&L for two coat of distemper oil emulsion to newly plastered surfaces of walls including preparation of surface over one coat of primer complete all as specified and directed.
M & L preparation of new plastered surface and applying two coat of external weather coat on external wall all as specified and directed.
Taking down chowkhat or frames with shutters (without taking off shutters from the frame) n.exc 1.5 Sqm each complete all as specified and directed.
Taking down chowkhat or frames with shutters (without taking off shutters from the frame) exc 1.5 Sqm but n.exc 4 Sqm each complete all as specified and directed.
Taking down shutters of any description exc 1 sqm but n.exc 2 sqm each complete all as specified and directed.
S&F powder coated aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc (minimum thickness of powder coating 50 micron) complete all as specified and directed by Engr-in-Charge
S&F powder coated aluminium door shutters, aluminium section weight 0.55 Kgs/m including necessary joining cleats, glazing clips, ruber neoprene packing, handle 02 Nos in each door, hinges, anodised aluminimum snap beading, screws (Thickness of powder coating not less than 50 micron) etc complete all as specified and directed.
S&F powder coated aluminium window and ventilator shutters, side hung type without sash bar, aluminium section weight 0.55 Kgs/m including necessary joining cleats, glazing clips, ruber packing, anodised aluminimum snap beading, screws (Thickness of powder coating not less than 50 micron) etc complete all as specified and directed.
S&F Aluminium grills size exc. 4mm x 4mm and aperture n exc. 80mm incl. fixing with aluminium channel, 1mm thick with steel screw and tint match with existing complete all specified and directed
S&F 4mm thick aluminium composit panel of any colour fixed to door with necessary rubber gasket and aluminium snap beadings tint match with existing complete all as specified and directed by Enge-in-Charge.
S&F 4mm thick tinted glass fixed with necessary rubber gasket and aluminium snap beadings tint match with existing complete all as specified and directed.
S&F Factory made solid PVC Moulded door shutter (with Wood free EPS), 28 to 30mm thick (stiles), with 2, 4 or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm Plain colour PVC Sheet on back face complete all as specified and directed.
S & F solid PVC moulded door frame of size 50 mm x 47 mm made out of 5 mm thick PVC sheet (shade matching with door shutter) reinforced with MS Square tube and edges will be painted to match with printed sheet complete all as specified and directed.
S&F IInd class hard wood, Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified.
S&F 30 mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed.
M&L preparation of new wooden surface and applying two coat of synthetic enamel paint over one coat of pink primer of any description not otherwise described over 10 cm width or girth complete all as specified and directed.
S&F 100 mm long powder coated Aluminium tower bolt, tint existing to match complete all as specified and directed.
S&F 150 mm long powder coated Aluminium tower bolt, tint existing to match complete all as specified and directed.
S&F 100 mm long powder coated Aluminium handles, tint existing to match complete all as specified and directed.
S&F 150 mm long Aluminium anodised, barrel tower bolts of extruded section complete all as specified and directed.
S&F 150 mm long Aluminium handles, cast type anodised, complete all as specified and directed.
S&F for 200 mm long aluminium alloy, anodised, sliding door bolt with hasp, staples(bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as directed and specified
S&F in repair for 250 mm long aluminium alloy, anodised, sliding door bolt with hasp, staples(bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as directed and specified
S&F for 300 mm long aluminium alloy, anodised, sliding door bolt with hasp, staples(bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as directed and specified
S&F 75 mm long butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type C-21 complete all as directed and specified
S&F 100 mm long butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type C21 complete all as directed and specified
S&F in repair, door closer hydraulically regulated, designation No. 1 universal type, suitable for door shutters up to 700 mm in width and of weight not more than 35 kg complete all as specified and directed.
S&F in repair double action floor spring hydaulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty including necessary cutting to floor and concrete work complete all as specified and directed.
S&F in repairs 100 mm Brass Mortice lock, 4 Levers, vertical type suitable for aluminium doors Make : (Godrej, Harrison, Link) etc
M&L for preparation of old decorated wall suraces and applying one coat of distemper oil emulsion with Roller on wall surfaces including filling the cracks and depression with putty to make the surface even & smooth complete all as specified and directed.
M&L for Preparation of old decorated plastered or unplastered surfaces of external walls and applying one coat of exterior weather proof Paint including filling cracks/depressions with wall putty to make the adjacent surface even and smooth complete all as specified and directed.
Taking down carefully existing unserviceable flame proof point wiring of any description & in any height ( 4m to 16m ) position with and including existing conduit fixed on surface with and including existing junction boxes in between the point wiring complete, including making good the disturbed surface of walls, floors, ceiling etc to match with the existing surfaces complete all as specified and directed. NOTE: (i) Old existing junction boxes obtained in serviceable condition from taking down of point wiring shall be re-used in the work. (ii) Taking down / replacement of existing fittings like switches/sockets / switch fuses / tube light fittings etc. if any, shall be measured and paid for separately under appropriate item of Schedule `A'
Taking down carefully existing unserviceable flame proof point wiring of any description & in any position , any height ( 4m to 16m ) from existing conduits fixed on surface or concealed including accessaries & fixtures etc and making good the distrubed surface of walls, floors, ceiling etc to match with the existing surface complete all as specified and directed NOTE: (i) Taking down / replacement of existing fittings like switches/sockets / switch fuses / tube light fitting etc. if any, shall be measured and paid for separately under appropriate item of Schedule `A'
Material and labour for flame proof point wiring for one light point or one socket point controlled by one switch with using 1.5 Sqmm (nominal area) stranded copper conductor, single core, FRLSH PVC insulated & unsheathed cable, 1100 volts grade in and including stove enameled black, rigid steel conduits of size not less than 20 mm dia (Medium grade) fixed on surface of walls/ceilings any height ( 4m to 16m )as directed with all accessories and using 1.5 Sqmm (nominal area) stranded copper conductor single core FRLSH, PVC insulated & unsheathed cable as in earth wire connected to common earth dolly / fittings etc. complete all as specified and directed NOTE : (i) Old junction boxes retrieved in serviceable conditions shall be re-used in the work. However, additional junction boxes, if any required, for making new point wiring other than the quantity of junction boxes retrieved from taking down of point wiring, shall be measured and paid for separately as ‘’supply only’’ under appropriate item of Schedule `A' but fixing element of any type of junction boxes new or old is deemed to be included in the rates quoted by the contractor for the above item. (ii) Wiring shall be terminated and connected to the relevant switch / controlling switch gear and relevant fittings / sockets all as directed and controlling switch / fittings shall be measured and paid for separately under appropriate item of Schedule `A'.
All as per item No 59 here-in-before but point wiring with using 2.5 Sqmm (nominal area) stranded copper conductor, single core, FRLSH PVC insulated & unsheathed cable for 16 A Flame proof Switch and socket
Material and labour for flame proof point wiring for one light point or one socket point controlled by one switch with using 1.5 Sqmm (nominal area) stranded copper conductor, single core, FRLSH PVC insulated & unsheathed cable, 1100 volts grade in existing conduit fixed on surface of walls/ceilings as directed and using 1.5 Sqmm (nominal area) stranded copper conductor single core FRLSH, PVC insulated & unsheathed cable any height ( 4m to 16m ) as in earth wire connected to common earth dolly / fittings etc. complete all as specified and directed NOTE : (i) Point wiring shall be executed with using existing conduits and junction boxes but contractor’s quoted rates for the above item is deemed to include the cost of fixing the existing conduits and junction boxes in position properly as per site requirement and as directed by the Engineer-in-Charge. (ii) Wiring shall be terminated and connected to the relevant switch / controlling switch gear and relevant fittings / sockets all as directed and controlling switch / fittings shall be measured and paid for separately under appropriate item of Schedule `A'.
All as per item above here-in-before but point wiring with using 2.5 Sqmm (nominal area) stranded copper conductor, single core, FRLSH PVC insulated & unsheathed cable for 16 A Flame proof Switch and socket complete all as specified and directed.
M&L for sub main wiring in repair concealed using Four single core PVC insulated, FRLSH, stranded copper conductor cable any height ( 4m to 16m ) of size 4 Sqmm for sub main wiring, along with one run of 4Sqmm PVC insulated, FRLSH, Stranded copper conductor cable for earth continuity conductor in steeel conduit complete all as specified and directed. Note: Four run of single core PVC cable with one run of earth wire and one run of steel conduit together shall be measured as one unit.
All as per item No. 63 here-in-before but using Two single core, 2.5 Sqmm copper conductor cable and with earth continuity conductor. Note: Two run of single core PVC cable with one run of earth wire and one run of steel conduit together shall be measured as one unit.
All as per item No. 63 here-in-before but using Two single core, 1.5 Sqmm copper conductor cable and with earth continuity conductor. Note: Two run of single core PVC cable with one run of earth wire and one run of steel conduit together shall be measured as one unit.
Disconnecting and taking down carefully flame proof, weather proof, toggle type switches and making good the disturbed surfaces complete all as specified and directed.
Disconnecting and taking down carefully flame proof DB’s of any size/way and making good the disturbed surfaces complete all as specified and directed.
Disconnecting and taking down carefully flame proof, Switch socket of any capacity and making good the disturbed surface complete all as specified and directed.
Supply & fixing flame proof push button 10 Amps in LM 6 metal enclosures, conforming to cat part No PBS / OA /1010-1A of make Sudhir or equivalent model of other make as specified complete all as specified & directed.
Supplying & fixing flame proof, switch socket & plug combined made of aluminum alloy LM-6 having 2 pole + earth suitable for 250 volts supply and current rating of 16 Amps complete all as specified & directed. (Make/model – Sudhir cat part No. SS/OA/1010 -1 or equivalent model of other make as specified).
Supplying & fixing flame proof, switch socket & plug combined made of aluminum alloy LM-6 having 4 pole + earth suitable for 500 volts supply and current rating of 32 Amps complete all as specified & directed. (Make/model – Sudhir cat part No. SS/187 or equivalent model of other make as specified).
Disconnecting & taking out existing unserviceable socket’s plug of any description and in any position and supplying & fixing new spare plug suitable for existing flame proof, weather proof, switch, socket & plug combined in LM-6 for 2 poles + earth & current rating of 16 Amps complete all as specified and directed. (Make – Sudhir or other make as specified ).
All as per item No 72 here-in-before but plug suitable for 4 pole + earth & current rating of 32 Amps (Make – Sudhir or other make as specified).
Supply & replace flameproof distribution board 8 way single pole & neutral in LM-6 metal enclosures with and including 01 No MCBs single pole and neutral 40 Amps & 06 Nos MCB single pole 16 Amps `C’ series complete all as specified and directed. (Make : Cat part no MCDB-186 of Sudhir or equivalent model of other make as specified.
Supply & replace flameproof distribution board 4 way Triple pole & neutral in LM-6 metal enclosures with and including 01 No MCBs tripple pole and neutral 63 Amps & 06 Nos MCB single pole 16 Amps `C’ series complete all as specified and directed. (Make : Cat part no MCDB-186 of Sudhir or equivalent model of other make as specified).
Supply & fixing in replacement flameproof distribution board 4 way Triple pole & neutral in LM-6 metal enclosures with and including 01 No MCCB tripple pole and neutral 100 Amps as Incoming & Out going MCB 63 Amps TPN 415 volts -01 No,MCB DP 32 Amps 240 Volts-01 No and MCB SP 16 Amps 240 Volts -03 Nos complete all as specified and directed. (Make : Cat part no MCDB-186 of Sudhir or equivalent model of other make as specified).
Supply & fixing in replacement FLP Flexible metelic Hose conduit M20/3/4ET 300 mm long complete all as specified and directed. (Make : Cat part no FH/199of Sudhir or equivalent model of other make as specified).
Supply and replce in repairs LED driver 240 V 50 Hz suitable for the existing LED flame proof lights fittings installed at any height from 3m to 18 m (Make Sudir) for the following watt :- (a) 75-90 Watt
(a) 120-180 Watt
Supply & freplace in repairs flame proof FLP Flood light 60 W LED fittings as per IS : 2148 / 1981 & 2206 (Part-I )1984, Temperature class T-4, & made of cast aluminum alloy LM-6 having inside & outside light grey powder coating shade No 631 as per IS: 5 & one No internal earthing terminal and 02 Nos external earthings of screw of M6- size with 02 Nos plain washers heat resistant glass including taking down the unserviceable fitting from any height ( 3m to 16m) complete all as specified and directed. Make : Sudhir /Baliga/CG..
Supply & fixing flame proof FLP Flood light 70 W LED fittings as per IS : 2148 / 1981 & 2206 (Part-I )1984, Temperature class T-4, & made of cast aluminum alloy LM-6 having inside & outside light grey powder coating shade No 631 as per IS: 5 & one No internal earthing terminal and 02 Nos external earthings of screw of M6- size with 02 Nos plain washers heat resistant glass ncluding taking down the unserviceable fitting from any height ( 3m to 16m) complete all as specified and directed. Make : Sudhir/Baliga/CG..
Supply & fixing flame proof FLP Flood light 90 W LED fittings as per IS : 2148 / 1981 & 2206 (Part-I )1984, Temperature class T-4, & made of cast aluminum alloy LM-6 having inside & outside light grey powder coating shade No 631 as per IS: 5 & one No internal earthing terminal and 02 Nos external earthings of screw of M6- size with 02 Nos plain washers heat resistant glass ncluding taking down the unserviceable fitting from any height ( 3m to 16m) complete all as specified and directed. Make : Sudhir Cat Part No 0151 /Baliga/CG..
Supply & fixing flame proof FLP Flood light 120 W LED fittings as per IS : 2148 / 1981 & 2206 (Part-I )1984, Temperature class T-4, & made of cast aluminum alloy LM-6 having inside & outside light grey powder coating shade No 631 as per IS: 5 & one No internal earthing terminal and 02 Nos external earthings of screw of M6- size with 02 Nos plain washers heat resistant glass ncluding taking down the unserviceable fitting from any height ( 3m to 16m) complete all as specified and directed. Make : Sudhir Cat Part No 1251 /Baliga/CG..
Supply and replace LED Tube rod 28 W T-5 suitable for existing flame proof tube light fitting installed at any height 3m to 16m complete all as specified and directed.
Supply and fixing in distribution board, single pole (SP) MCB 6 to 20 Amps, 240 volts, 50 Hz, AC made from molded self extinguishing thermostat plastic and suitable for ‘ C ‘ curve, 10 KA breaking capacity conforming to IS : 8828 of 1996 including taking down unserviceable MCB complete all as specified and directed.
Supplying and fixing flame proof junction box 3 way ¾ “ entry in LM – 6 complete all as specified and directed.
Supply and replace LED flame proof well glass fitting 70 Watt including taking down the unserviceable fitting from any height ( 3m to 16m) fith necessary driver, fittings and fixtures complete all as specified and as directed.
S&F in repair Ultra bright glass 20W LED tube light and high efficiency from any height 3 m to 16 m suited for installation in exsiting flame proof Tube light fitting (T-8) alongwith G3 lamp holders complete all as specified and directed. Make :-Havells Cat part No -CRYSTAL1213T8DSTL20WLED865SGLASS or equivalent model of make Philips/Oshram
M & L for checking & repairing flame proof tube lights/flood lights/ & other flame proof connected work as directed in tech area and repairing of flameprrof lights found unserviceable during checking or as per directed by JE/Engr-in-Charge/men on complaint cell including rectification of fault of wirng etc by deploying skilled Electrician, helper with all tools & plants, ladder, gaskets safety arrangements and including providing minor materials like insulation tap and connected material by contractor to make light serviceable complete all as specified and directed. NOTES :- (i) Rate quoted shall deemed to be included for required minor material like insulation tap,rubber gasket and packing materilas required for of junction box with lugs etc. (ii) Items like Driver for LED and other items other than mentioned above paid separately.
Supply and replce LED driver 240 V 50 Hz suitable for the existing LED flame proof lights fittings (Make Sudir) for the following watt :- (a) 75-90 Watt
(a) 120-180 Watt
Fixing only the following falme proof distribution boards complete with all necesary fittings and fixture all as specified and as directed (a) Flame proof distribution Board SPN 8 way in LM-6metal Enclosures Note: 1. Required nut and bolts T&P for fixing is deemed to be included in the quoted rate. 2. Required MCB for DB will be measured and paid seperetely.
(b) Flame proof distribution Board TPN 4 way in LM-6metal Enclosures
Taking down carefully the flame proof distribution board cover of any capacity any make, replacing the buntout wiring of any type and any size, tightning the connectors and MCB's, refixing the cover after cleaning complete all as specified and as directed.
Supply and replace MCB C Series SPN 32 Amp complete suitable for fixing inside flame proof distribution Board
Supply and replace MCB C Series TPN 40 Amp complete suitable for fixing inside flame proof distribution Board
Supply and replace MCB C Series SP 6 to 32 Amp complete suitable for fixing inside flame proof distribution Board
Arkay Instrumentation
m/s vikash Engineers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .