Loading…
Loading…
Tender Value
₹1.6 L
EMD Value
₹3,240
Closing Date
3 Sept 2026, 12:00 pm
Executive Engineer, HSVP, Elect, Division, Hisar
Executive Engineer, HSVP, Elect, Division, Hisar
Providing Copper Pipe in RCC Beam and Brick Wall for installation of 1.5TR Split Air Conditioner in Gymkhana Building, Sector14 at Bhiwani Excluding GST.
2026_HBC_543327_1
Job No. 41.26
Open Tender
Electrical Works
Works
Bhiwani
Providing Copper Pipe in RCC Beam and Brick Wall for installation of 1.5TR Split Air Conditioner in Gymkhana Building, Sector14 at Bhiwani Excluding GST.
2 documents required · 2 mandatory
₹250
₹3,240
Yes
25 Aug 2026
25 Aug 2026
3 Sept 2026
25 Aug 2026
3 Sept 2026
25 Aug 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | 22.86.3
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) 25 mm nominal outer dia Pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. | 100 | Metre | 333 | ₹33,300 |
| - | 23.35.14.1
COPPER REFRIGERANT PIPING Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitableadjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : (Excluding GST) | 50 | Metre | 217 | ₹10,850 |
| - | 23.35.14.3
COPPER REFRIGERANT PIPING Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitableadjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : (Excluding GST) | 50 | Metre | 413 | ₹20,650 |
| - | Job Work
Core cutting of 100 mm dia and 300mm long in Brick Wall. (Excluding GST) | 10 | Each | 1,980 | ₹19,800 |
| - | Job Work
Core cutting of 100 mm dia and 450mm long in RCC Beam. (Excluding GST) | 10 | Each | 7,700 | ₹77,000 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.04 MB
BOQ_622846.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].