RMO of water treatment plant having capacity 10000 ltrs/hr i/c clear water pump sets, submersible pump set, compound and street -----Masts at Block A-2 Commercial Complex, Paschim Vihar.
2026_DDA_929688_1
14/EE (E)/ELD-10/DDA/2026-27
Open Tender
Electrical Works
Works
365 days
EE(E)/ELD-10/DDA
Please refer Tender documents.
13 documents required · 13 mandatory
₹0
₹56,482
Yes
9 Oct 2026
9 Oct 2026
17 Oct 2026
9 Oct 2026
16 Oct 2026
9 Oct 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Running, maintenance and operation of water treatment plant having capacity 10000 ltrs/hr i/c clear water booster pump set, submersible pump set and compound and street lighting raddison blue hotel at distt. Centre, Paschim Vihar maintenance & operation of I.E.I., Fans, compound lights & Sub. Pump set at Community Halls Near 208 SFS Madipur, Pkt-3 Paschim Puri, A-3 Paschim Vihar & high Masts at Block A-2 Commercial Complex, Paschim Vihar as per inventory and terms and condition attached by deploying the following staff:-
i) Pump Operator Grade-II – 2 Nos. per day i.e. from 6:00 AM to 2:00 PM and 2:00 PM to 10:00 PM
i) Khallasi – 1 No. from 10:00 PM to 6:00 PM & as and when required.
i) Wireman Gr-I – 1 No. per day from 9:00 AM to 5:00 PM & as and when required. | 12 | Month | 1,52,767 | ₹18,33,204 |
| 2 | LED Street light fixture, powder coated pressure die cast aluminum body (System lumen efficacy >105<120lm/Watt)
Supplying, replacement, installation, testing & commissioning of Street light LED fixture powder coated pressure die cast aluminum body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L, N, E as per IEC 61000-4-5, Driver efficiency >85%, THD <10% as per IEC 61000-3-2, P.F.> 0.95, IP-66, IK-10, CRI >80, under voltage and over voltage protection, EMI-EMC As per CISPR-15, lenses for beam angle as per IESNA type l/ll/lll as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) if minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IEM TM-21-11 report, CCT 3000 K/ 4000K/ 5700K/6000K/6500K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and fixture shall be relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >105<120 lm/Watt output. LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90OC).
a) 90 watt | 7 | Each | 1,679 | ₹11,753 |
| 3 | Supplying & Dosing of High TDS antiscalent dosing chemicals for operation of 10m3 / hr RO Water Treatment Plant (considering approx. 2 ltr /day which is given in Annexure-II (Considering 10 hour operation per day) complete as required. | 730 | Ltr. | 224 | ₹1,63,520 |
| 4 | Supplying of membrane washing chemical (Quantity-50 ltr) and cleaning the existing membrane (Model no. of Membrane CPA 5 LD 80-40 and No. of Membrane=10,Dia/length=8 inch X 40 inch) along with Expert service engineer staff of in RO system with the help of membrane flushing system i/c membrane decaling changes fixing again after cleaning testing commissioning etc complete as required as per direction of Engineer-in- charge (as per Annexure II). | 2 | Job | 15,665 | ₹31,330 |
| 5 | Supply and Replacement of Micron cartage filter suitable for a flow rate of 20000 LPH to achieve particle filtration of less than 5 microns and MCF shall be PP and jumbo 20’’ (considering approx. 3 filter changes/3 days) (as per Annexure II) complete as required. | 365 | Each | 450 | ₹1,64,250 |
| 6 | Supplying and replacement of membrane having specification as below:- Model No. of Membrane is CPA 5LD 80-40,membrane diameter /length: 8inchX 40 inch in all aspect. | 5 | Each | 37,091 | ₹1,85,455 |
| 7 | Supply & Dosing of multi grade media for operation of 10000 ltrs/hr RO Water Treatment Plant along with Expert service engineer staff of RO system i/c installation, commissioning, testing etc. complete as required | 300 | Kg. | 18 | ₹5,400 |
| 8 | Supply & Dosing of Activated carbon for operation of 10000 ltrs/hr RO Water Treatment Plant along with Expert service engineer staff of RO system i/c commissioning, testing etc. complete as required . | 300 | Kg. | 129 | ₹38,700 |
| 9 | Supplying, replacement, installation & commissioning of the following size Multiport valve i/c dismantling.
i) 50 mm (2”) | 2 | Each | 7,597 | ₹15,194 |
| 10 | Supplying, replacement, installation & commissioning Pressure gauge (7kg to 21kg) i/c dismantling. | 7 | Each | 546 | ₹3,822 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.57 MB
Tendernotice_2.pdf
PDF • 2.72 MB
BOQ_976970.xls
BOQ • 0.97 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .